Wood Deck Anchor. Instructions READ CAREFULLY Garrymore Ln Missoula, MT

Similar documents
THE SCOUT WOOD-DECK ANCHOR

LEAVE THIS MANUAL WITH LIFT OWNER

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

ATLANTIS RAIL Contact Information

CYCLONE TM ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

TURBOTWISTER TM ASSEMBLY AND INSTALLATION INSTRUCTIONS

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

May 14, Installation Manual

HILGARD Part Number Spectrum Lane ~ Missoula MT ~

Model: SS660-PT-R Stainless Steel Poly-Top Floor Scale Series. Installation, Set-Up and Operation Manual

INSTITUTIONAL LIFEGUARD STAND

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

Model: SS660-OB Stainless Steel Floor Scale Series. Installation, Set-Up and Operation Manual

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

THE CASCADE & SLINGER FUNSLIDES

THE AquaBlast & RocketRide FUNSLIDES

CYCLONE ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * *

Assembly Instructions for model: VMPR1

THE ROGUE TM FUNSLIDE TM

TV WALL MOUNT ASSEMBLY GUIDE RF-TVMLPT01V2

TURBOTWISTER ASSEMBLY AND INSTALLATION INSTRUCTIONS

MTS-ACB. RENOGY Photovoltaic Module Adjustable Curved Bracket E Philadelphia St, Ontario, CA Version: 1.

LC6X4WTM Security Wall Mount with Tilt for up to 60" Flat Screens with VESA 600mm x 400mm or less

MSP-DCCPGTU Large Screen Tilt Display Mount

Side DuraRac Installation Instructions

INSTALLATION INSTRUCTIONS. PLASMA TV WALL MOUNT TILT Universal (RGTU-210) WARNINGS WARNING

MSP-DCCPGSU Large Screen Static Display Mount

MPA-9000 Universal Ceiling Projector Mount Kit

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

Installation Instruction

LC200DS2 Double Stud Dual Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

42 SENTRY LIFEGUARD STAND

MTS-ZB. RENOGY Photovoltaic Module Z-Bracket Mounting System E Philadelphia St, Ontario, CA Version: 1.

ASSEMBLY AND INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

ATLANTIS RAIL Contact Information: Atlantis Rail Systems 70 Armstrong Road 3900 Civic Center Drive Plymouth, MA North Las Vegas, NV 89030

LC200WT Security Wall Mount with Tilt for up to 32" Flat Screens

3 wide x 3 deep Video Wall Display Installation Guide

LARGE FLAT PANEL DISPLAY STATIC MOUNT PST 2000 Series

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL

SolarMount (E)volution

Rear Mount Installation Instructions

The following instructions will guide you through the installation of your new vinyl railing stair kit.

19 to 39 TV WALL MOUNT - FULL MOTION

TREX POST MOUNT DECKING AND CONCRETE

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

THE ROGUE TM GRAND RAPIDS TM ASSEMBLY AND INSTALLATION INSTRUCTIONS

TP4463. ASSeMBly INSTruCTIONS FLAT PANEL TV MOUNTING SYSTEM OPTION 1 OPTION 2 OPTION 3

Bumper Sign INSTALLATION INSTRUCTIONS

3/4 Rear DuraRac Installation Instructions

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

PHTM200 - Phantom 200 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 50 lbs with 200mm Mounting Patterns

CSS Central Mount System

Ceiling Mount - 32" to 60" - Single Installation Instructions

Side Katerack Installation Instructions

LOW PROFILE LIFEGUARD STANDS

BLACK WIDOW COMPOSITE

Heavy Duty I-Beam Trolley

PART #MSP-DCCST Flat Panel Tilt Mount

The following instructions will guide you through the installation of your new vinyl railing.

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

UPDATED REV.5 BLACK WIDOW. Detailed installation manual. Patent pending P/N: BW-S, BW-B, BW-F.

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Katerack Wagon Shelving System

INSTALLATION INSTRUCTIONS

The Festival Assembly Instructions

SILVERBACK INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Rear Katerack Installation Instructions

Assembly Instructions. Important!

Downtown Rack. Custom logo option available

Calf-Tel Pen System Assembly Instructions

Assembly Instructions. Important!

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

32 Gallon Perforated Square Receptacle

Swerve Rack CUSTOM RACKS AVAILABLE

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

owners Model No CAUTION: Read Rules for Safe Operation and Instructions Carefully Safety Assembly Operation Maintenance Parts

Oval Vinyl Gazebo. Assembly Manual

3 11/16" [94.0mm] HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY 6" [152.4mm]

INSTALLATION INSTRUCTIONS

Equilibrium Credenza

RangerWare Fiberglass Door System Installation Instructions P/N

INSTALLATION GUIDE. Version 2.0

BASEBALL FOUL POLES SURFACE MOUNTED

2009 MODEL ASSEMBLY, INSTALLATION AND MAINTENANCE INSTRUCTIONS

Assembly & Installation Instructions FOR VEHICLE MOUNT KIT USING VEHICLE CENTER MEMBER

PHTM100 - Phantom 100 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 25 lbs with 100mm or 75mm Mounting Patterns

INSTRUCTION BOOKLET #C21. For Wallbed models: KING SIZE

Full Height Ladder Safety Gate

3. Use base plate as template (see FIG. 4-1) to mark location for fasteners.

STEP 1 STEP 2 LEVELER KIT OPTION MOBILE CASTER KIT OPTION

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

Transcription:

Wood Deck Anchor 9889 Garrymore Ln Missoula, MT 59808 888-687-3552 +1-406-549-0769 www.aquacreek.com Instructions PART #: F-40220-AT1 Pro Pool Lift - Weight Capacity (450 LBS) / Max Setback (19 ) Pro Pool Lift Ext Base 23 - Weight Capacity (450 LBS) / Max Setback (23 ) Pro Pool Lift Ext Base 26 - Weight Capacity (450 LBS) / Max Setback (26 ) Pro Pool Lift Deep Draft - Weight Capacity (400 LBS) / Max Setback (17 ) Ranger Lift - Weight Capacity (350 LBS) / Max Setback (19 ) MANDATORY LEAVE THIS MANUAL WITH LIFT OWNER Read and follow all instructions. Lift safety can only be ensured if the lift is installed and operated according to these instructions. NEVER permit children to play on or around the lift Do not allow children to use the lift without adult supervision NEVER apply direct water pressure to the electronics NEVER use the lift with a dry pool READ CAREFULLY Check entire box and all packing materials for parts. Before beginning assembly, read the instructions and identify parts using the figures and parts listed in this document. It is critical that all parts be carefully inspected prior to installation. If any damage occurred in transit, Aqua Creek Products, LLC must be notified within three days of receipt of unit. Proper installation cannot be overstressed, as an improper installation voids Aqua Creek s warranty and may affect the safety of the user. 1

ADA-Compliant Instructions The AT-SERIES WOOD-DECK ANCHOR has been designed to comply with the latest ADA requirements. It has a simple design, and can be retrofitted with a nominal amount of time, tools and expense. To be ADA compliant, the fixed lift must have the required clear-deck space as shown below. The AT-SERIES WOOD-DECK ANCHOR is designed to remain in place if the lift is removed for storage. Note: the AT-SERIES WOOD-DECK ANCHOR has been designed to comply with the NEC requirements for bonding. By bonding the anchor you are also bonding the installed lift. Bond the lift according to your local requirements (ref NEC). POOL/SPA POOL WALL *SEE BELOW 10" 16" MIN. 11" CHAIRC L 51" 40" 12" ADA REQUIRED CLEAR-DECK SPACE 48" 36" 50 1 4 " Front Anchor Setback Distance Pathfinder: 14.5-16 Ranger: 14.5-19 Pro Pool: 14.5-19 Pro Pool 23 Ext Base: 19-23 Pro Pool 26 Ext Base: 23-26 Pro Pool Deep Draft: 14.5-17 Note: All setback distances are based on a straight pool wall. Setback distances will change for curved pool walls. Contact Aqua Creek for curved wall setback distances. 2

The AT-Series Wood-Deck Anchor The diagram below shows the AT-SERIES WOOD-DECK ANCHOR with the included bonding-lug and hardware. Note the bonding-lug can be attached to either the front or back of the AT-SERIES WOOD- DECK ANCHOR, and on either the top or bottom for ease of wiring. NOTE: the AT-SERIES WOOD-DECK ANCHOR should be electrically bonded to the pool/spa bonding grid using minimum 8AWG solid copper wire. Attaching the 8AWG solid copper wire to the copper bonding lug and to the bonding grid will bond the installed lift through the 1/2 mounting bolts. 10-24 X 3/4" SOCKET-HEAD CAP-SCREW (SS) AT-SERIES WOOD-DECK ANCHOR ALTERNATE MTG. HOLE FOR BONDING-LUG BONDING-LUG CAN BE ON TOP OR BOTTOM POOL GBL-4DB SOLID-COPPER BONDING-LUG 10-24 NYLOCK- NUT (SS) HOLES FOR LAG BOLTS (2) ON SIDES FIGURE 2 3

Installation Overview: Components The following diagram shows the AT-SERIES WOOD-DECK ANCHOR in a typical installation. Note the 2 x 6 x 36 reinforcing boards are installed first, under the decking, to support the entire area around the lift. The following tools and hardware will be required to complete the installation. TOOLS REQUIRED: 1] 5/8 DRILL BIT 2] CORDLESS OR ELECTRIC DRILL 3] MARKING PEN STAINLESS HARDWARE REQUIRED: 1] 1/4 X 2 LAG BOLTS (2) 2] 1/4 FLAT WASHERS (2) 3] 1/2-13 X 4 HEX BOLTS (4) 4] 1/2 FLAT WASHERS (4) FIGURE 4 1/2"-13 X 4" HEX BOLTS (4) 1/2" FLAT WASHERS (4) 1/4" X 2" LAG BOLTS (2) 1/4" FLAT WASHERS (2) 2X6 X 36" REINFORCING BOARDS AT-SERIES WOOD-DECK ANCHOR NOTE: Bolt length shown is for typical 2 thick deck boards Longer bolts may be necessary for your application We recommend 316 stainless hardware 4

Step 1: Install 2x6 Reinforcing Boards Once the location for the lift has been determined it will be necessary to install two (2) 2 x 6 x 36 long reinforcing boards underneath the location of the anchor. The AT-SERIES WOOD-DECK ANCHOR will be mounted between two floor joists, and the joists can run either towards the pool/spa or sideto-side. The following instructions show the joists running towards the pool/spa, for illustration purposes. REINFORCING BOARDS: INSTALL AGAINST FLOOR JOISTS AND FRONT PLATE (BOTTOM VIEW) NOTE: The reinforcing boards are installed from underneath, flush against the floor joists on either side, and all the way up to the front plate/hanger. Use deck screws to hold the reinforcing boards in place. 5

Step 2: Mark Location For 5/8 Holes Using the lift s baseplate as a template, mark the four holes at the desired lift location (Reference chart on page 2). Also, make sure to line the holes between the floor joists so the AT-SERIES WOOD- DECK ANCHOR fits between the joists. PLACE THE BASEPLATE AT DESIRED LOCATION MARK THE FOUR MOUNTING HOLES 6

Step 3: Drill Four (4) 5/8 Diameter Holes With the hole locations marked, drill the four mounting holes. Using a 5/8 drill bit and an electric or cordless drill, drill straight down at the four marked locations. Use a square or level to make sure you are drilling straight down, and make sure you drill at the exact center of the circles. HINT: USE A TAPE-MEASURE TO CHECK THE HOLES ARE 11 x 10 SQUARE WITH 5/8 BIT: DRILL STRAIGHT-DOWN AT 4 MARKED LOCATIONS 7

Step 4: Install The Wood-Deck Anchor With the four mounting holes drilled the AT-SERIES WOOD-DECK ANCHOR can now be installed underneath the deck and onto the reinforcing boards. Use the mounting bolts (1/2 hex) to hold the anchor in place, and install the 1/4 lag bolts as shown below. When the anchor is in place the 1/2 hex bolts can be removed and the lift can be installed. Also, bond the lift using the copper bonding lug per local electrical codes. DECKING 2X6 X 36" REINFORCING BOARDS 5/8" HOLES (ALIGN WITH ANCHOR) BONDING LUG (FRONT OR BACK) 1/4" FLAT WASHER (2) 1/4" LAG BOLT (2) AT-SERIES WOOD-DECK ANCHOR 2X6 (MIN) FLOOR JOISTS HINT: ALIGN & HOLD THE ANCHOR IN PLACE USING THE 1/2" MOUNTING BOLTS, THEN INSTALL THE 1/4" LAG BOLTS. THIS WILL MAKE SURE THE HOLES LINE UP. 8

Step 5: Install The AT-Series Lift Once the AT-SERIES WOOD-DECK ANCHOR has been installed the lift is now ready for installation. Using the 1/2 mounting bolts and flat washers, mount the lift to the deck as shown below. Use a 9/16 wrench or socket and tighten the bolts until snug. DO NOT OVERTIGHTEN THE MOUNTING BOLTS! AT-SERIES POOL LIFT 1/2" HEX BOLT (4) (STAINLESS STEEL) *NOT INCLUDED 1/2" FLAT WASHER (4) (STAINLESS STEEL) *NOT INCLUDED POOL *Length of mounting bolts will depend on thickness of deck you need to go through. 9