No. MXDP Indexer Application Software Model: 3G3MX2 CX-Drive Version QUICK START GUIDE

Similar documents
AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

Cat. No. I216E-EN-01. Model: 3G3RX CX-Drive Version:

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

EDC Quick Start Guide

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

6.9 Jump frequency - Avoiding frequency resonance

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

CSMIO/IP-A motion controller and Mach4

MTY (81)

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- ORIENTATION CONTROL / ENCODER FEEDBACK CONTROL / PULSE TRAIN INPUT FR-A5AP

Dynamo Brushless DC Motor and GreenDriveTM Manual

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

MTY (81)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

WMX2 Parameter Manual

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

HPVFP High Performance Full Function Vector Frequency Inverter

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

PG Interface Card "OPC-E1-PG"

G320X MANUAL DC BRUSH SERVO MOTOR DRIVE

OPC-E1-PG3 Specifications

PG Interface Card "OPC-E1-PG"

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

MASTER/SLAVE TENSION CONTROL

Copyright / Trademarks -This manual and its contents are copyrighted. -You may not copy this manual,in whole or part,without written consent of

General-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

VECTOR INVERTER -INSTRUCTION MANUAL- POSITION CONTROL FR-V5AP

Rotary Measurement Technology Absolute Encoders, Multiturn

CHAPTER 8 PARAMETER SUMMARY

TOSVERT VF-AS1 PID control Instruction Manual

TOSVERT TM VF-nC3 Parameter List

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

Manual Overview...1 2

General-Purpose AC Servo. Servo Amplifier Instruction Manual (Troubleshooting)

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual

Function Manual Basic Positioner SINAMICS. SINAMICS G120 Function Manual Basic Positioner. Introduction. Basic positioner. Appendix.

Troubleshooting 12. This section explains the items to check when problems occur, and troubleshooting by the use of error displays or operation state.

This section is specifically about safety matters

HB-25 Motor Controller (#29144)

SAFETY INSTRUCTIONS WARNING

Installation Servo Drive Dimensions

This section is specifically about safety matters

About this Manual: Chapter 1 provides a summary of the Servo System and all gains used for the Servo System loops.

P/N Revision: A2 Date: May 22, EMERSON Motion Control. All rights reserved.

For more information on these functions and others please refer to the PRONET-E User s Manual.

Yaskawa Electric America Unit Troubleshooting Manual Section Two: Power Checks GPD 506/P5 and GPD 515/G5 (0.4 ~ 160kW)

Chapter 8 Troubleshooting

Servo Indexer Reference Guide

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

TECHNICAL BULLETIN. Thank you for your continued support of Mitsubishi programmable logic controllers, MELSEC-A series.

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

Optical Kit Encoder Page 1 of 5. Description. Features

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

Tech Note #3: Setting up a Servo Axis For Closed Loop Position Control Application note by Tim McIntosh September 10, 2001

2HSS858H Low Voltage Digital Stepper Servo Drive Manual

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Series SGMBH/SGDH USER S MANUAL AC Servodrive (400 V, 22 to 55 kw) SGMBH Servomotor SGDH SERVOPACK

SYSMAC C200H-NC112 Position Control Unit

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

STEPPING MOTOR EMULATION

8902/RE and 8902/RR Resolver Speed Feedback Options

In the event of a failure, the inverter switches off and a fault code appears on the display.

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number :

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

Cat. No. I212E-EN-01C. Version: Torque Control with Diameter Sensor Model: 3G3RX CX-Drive Version:

Mach3 USB Motion Card (STB5100) Installation Manual

IC5 Series. LG Variable Frequency Drive 1/2-3 HP (230V) LG Industrial SystemsG. Installation, Operation and Maintenance Instruction

Inverter Drive /Vector Drive Motors & Controls

THYFREC-VT210S 400V System 37 to 315kW (C/T) 400V System 45 to 370kW (V/T) QUICK START GUIDE

FR-A8TP INSTRUCTION MANUAL

FR-A7AP INVERTER INSTRUCTION MANUAL. Orientation control Encoder feedback control Vector control. Plug-in option PRE-OPERATION INSTRUCTIONS

Safety Instructions WARNING. Do not remove the cover while power is applied or the unit is in operation.

How to Configure IFOV. Revision: 1.01

Manual. ihss57-xx. Integrate Stepper Servo Motor.

MEGA Servo setup procedure for driving PMS motor

FR-ABR-(H)0.4K to 22K

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Industrial motor controller for brushed DC motors 12 VDC

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

Bholanath. User s Manual. Precision Engineering Pvt.Ltd. BHSSD Step Servo Driver. Note:-

Optional add-on cassette Vector-option unit Instruction manual

Lab 5: Inverted Pendulum PID Control

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

Multifunction Keypad OP-KP-LCD. Multi-function Keypad with LCD & LED display for programming IMO Jaguar Inverters.

USER S MANUAL. OMNUC U SERIES MODELS R88M-U (AC Servo Motors) MODELS R88D-UT (AC Servo Drivers) AC SERVO MOTORS/DRIVERS (1 to 5 kw)

Absolute Encoders Multiturn

Operating Instructions VLT Extended Relay Card MCB 113

THYFREC-VT110S 200V 1PH System 0.4 to 2.2kW 400V 3PH System 0.75 to 2.2kW QUICK START GUIDE

Transcription:

No. MXDP-0010 Indexer Application Software CX-Drive Version. 2.8.1.07 QUICK START GUIDE

Table of Contents 1 GENERAL PRECAUTIONS... 3 1.1 Read These First!... 3 1.2 Handling of this instruction Manual... 3 1.3 Safety Instruction... 3 1.4 Related Manuals... 3 2 INTRODUCTION... 4 3 PROGRAM FUNCTIONS WITH DRIVE PROGRAMMING... 4 3.1 Home Function... 4 3.2 Jog Function... 5 3.3 Positioning Function... 5 4 DIGITAL INPUTS... 6 4.1 Parameter Settings... 6 5 DIGITAL OUTPUTS... 7 5.1 Parameter Settings... 7 6 VARIABLES/PARAMETERS... 7 7 OTHER CONSIDERATIONS... 8 7.1 Position Range... 8 7.2 Encoder disconnection Error... 8 Page 2 of 8

1 GENERAL PRECAUTIONS 1.1 Read These First! Positioning accuracy: Remember that MX2 is an open loop inverter. The positioning accuracy should be considered around +/- 10 pulses. Noise immunity: be careful with the loss of pulse by using a non-differential, non-line driver A-B 24Vdc inputs. Application program should consider the possibility of deviation of position. Relative Positioning: This program does not support wraparound (infinite relative movements). Position range from -268435455 to +268435455. Note: For more info refer to the MX2 User Manual. 1.2 Handling of this instruction Manual The contents of this Instruction Manual are subject to change without prior notice. No part of this Instruction Manual may be reproduced in any form without the publisher s permission. If you find any incorrect description, missing description or have questions concerning the contents of this Instruction Manual, please contact the publisher. 1.3 Safety Instruction Be sure to read this Instruction Manual, Inverter Instruction Manual, and appended documents thoroughly before using Indexer Application Program example and the inverter. Ensure you to understand and follow all safety information, precautions, and operating and handling instructions for the correct use of the inverter. Always use the inverter strictly within the range of specifications described in the Inverter Instruction Manual and correctly implement maintenance and inspection to prevent fault from occurring. When using the inverter together with optional products, also read the manual of those products. Note that the Instruction Manual and the manual for each optional product to be used should be delivered to the end user of the inverter. In this instruction manual you can find WARNING along the instruction WARNINGS: indicates that incorrect handling may cause hazardous situation, which may result in seiours personal injury or death. 1.4 Related Manuals The following manuals should be referenced for more details I570-E2-02A MX2 User s Manual W453-E1-19 CX-Drive Operation Manual I170E-EN-00 Drive Programming User s Manual I171E-EN-01 LCD 5 Line Digital Operator User s Manual Page 3 of 8

2 INTRODUCTION This example shows how to manage a Home and Jog functions, using the simple positioning function with simple encoder feedback input in MX2 and Drive Programming. The encoder in the example is 200ppr. Encoder wiring Check MX2 User Manual. This example is implemented with CX-Drive version 2.8.1.07. The CX-Drive file attached could not be open with a lower CX-Drive version. 3 PROGRAM FUNCTIONS WITH DRIVE PROGRAMMING To prepare the inverters for operation, the configuration tool CX-Drive is used for setting parameters and to download the Indexer Application Program. In the following chapters we will demonstrate the necessary steps to set up the inverter for a indexer application. We will use 3G3MX2. 3.1 Home Function The zero-return mode selection for the home function is High (P068 = 1:High). The homing direction implemented is reverse mode (P069 = 1:Reverse). Input Terminal [5] and terminal [6] are used for the home function. Activating the terminal [5], it starts the home function(org input). The motor starts running in reverse mode at the U(01) frequency (set to 0.9Hz on Initialize Subroutine) waiting for the limit signal/home sensor(orl input). When the limit signal is ON, the motor change to forward direction at the U(00) frequency (set to 0.2Hz on Initialize Subroutine), and then after losing the limit signal the motor stops. When the home function is finished, the terminal [11] output will set to ON during 1 second and the inverter current position data is reset to 0. After the home done signal is set to ON, the start homing signal must be set to OFF. If during Home function operation, some of the others digital input functions are activated, the motor will stop. Page 4 of 8

3.2 Jog Function Input Terminal [1] and Terminal [3] are used for the Jog function. Input Terminal [1] sets the rotation direction and Terminal[3] starts the Jog function. Setting input Terminal[1] to ON and Terminal[3] to ON, the motor starts moving in forward direction at Jog frequency setting (U(09)). On the other side, setting input Terminal[1] to OFF and Terminal [3] to ON, the motor starts moving in reverse direction at Jog frequency setting (U(09)). See table: Terminal[1] Terminal[3] (Rotation Direction) (Start Jog Function) Jog Function OFF ON Jog Reverse ON ON Jog Forward 3.3 Positioning Function This function only will be operative if homing function is done before. Input terminal [1] sets the rotation direction for positioning and terminal [2] starts the movement for positioning function. If input terminal [1] is set to ON and input Terminal[2] is set to ON, the motor starts the positioning, adding to the last current position reached, the position introduced in variable U(02). On the other hand, if input Terminal[1] is set to OFF and input terminal [2] is set to ON, the motor starts the positioning, subtracting to the last current position reached, the position introduced in variable U(03). See table: Terminal [1] Terminal [2] (Rotation Direction) (Start Positioning Function) Positioning Function OFF ON Decrease Position ON ON Increase Position The variables U(04) and U(05) correspond to the Set Speed and Creep Speed (P015 parameter) for positioning function. Take care with Set Speed and Creep Speed range. The specific error for Drive Programming E45.* will appear if the values are out of range. If other input terminal is activated during positioning, the motor will stop. If for example input terminal [2] is set to OFF before reaching the target position, when terminal[2] is being activated again, the target position will not change and the positioning will be completed. Page 5 of 8

If after executing the positioning function, the Jog forward/reverse function is executed, the next target position will consider the actual position as the starting point. The same behaviour occurs if during positioning the movement is interrupted and the Jog forward/reverse function is executed. This program does not support wraparound (infinite relative movements). Position range from -268435455 to +268435455. 4 DIGITAL INPUTS C001 - Terminal [1] function: X(00) Rotation Direction. It will change the rotation direction for Jog and Positioning functions. Setting this input to ON the rotation direction will be forward direction, and setting this input to OFF the rotation direction will be reverse direction. C002 - Terminal [2] function: X(01) Start Position function. The current position will be increased/decreased depending of the rotation direction setting. Besides, current position will be increased depending the value introduced on U(02) variable, and will be decreased depending the value instroduced on U(03) variable. Before executing a relative positioning, the Home function must be done. This program does not support wraparound (infinite relative movements). Position range from -268435455 to +268435455. C003 - Terminal [3] function: X(02) Start Jog function. C004 - Terminal [4] function: X(03) - Reset. C005 - Terminal [5] function: X(04) - Start Homming. C006 - Terminal [6] function: X(05) - Home Sensor. C007 - Terminal [7] function: EB encoder B channel (Rotation direction (C007 only)) 4.1 Parameter Settings Terminal Value Input 1 C001 = 56: X(00) Drive Programming (MI1) 2 C002 = 57: X(01) Drive Programming (MI2) 3 C003 = 58: X(02) Drive Programming (MI3) 4 C004 = 59: X(03) Drive Programming (MI4) 5 C005 = 60: X(04) Drive Programming (MI5) 6 C006 = 61: X(05) Drive Programming (MI6) 7 C007 = 85: EB (Rotation direction (C007 only) Description Rotation Direction Start Position Function Start Jog Function Reset Start Homing Home Sensor EB-Encoder B channel Page 6 of 8

5 DIGITAL OUTPUTS C021-Terminal [11] function: Y(00) - Home done. Digital Output activated to ON during 1 second by program. C022-Terminal [12] function: Y(01) - Target Position Reached. Digital Output activated to ON during 1 second by program. 5.1 Parameter Settings Terminal Output Name Description 11 C021 = 44: Y(00) Drive Programming (MO1) Home Done 12 C022 = 45: Y(01) Drive Programming (MO2) Target Position Reached 6 VARIABLES/PARAMETERS Variables Description Default value P100 Low speed zero return frequency for Homing. 0.2 Hz [P100 = 20] P101 High speed zero return frequency for Homing. 0.9 Hz [P101 = 90] P102 Relative position to increase. 1000 [P102 = 1000] P103 Relative position to decrease. 1000 [P103 = 1000] P104 Speed for Position function. 5.0 Hz [P104 = 500] P105 Creep Speed for Position function. 2.0 Hz [P105 = 200] P106 Acceleration time (U(07) x 10ms) for Position and Jog function. 100 ms [P106 = 10] P107 Deceleration time (U(08) x 10ms) for Position and Jog function. 100 ms [P107 = 10] P108 Jog Speed. 1.0Hz [P108 = 100] P110 Program Number. 10 [P110 = 10] Parameters Description P003 Encoder Feedback. P011 Encoder Pulse per revolution. P012 Simple positioning selection. P015 Creep speed setting. P031 Accel/decel time input selection (3:Drive Programming) P060 Multistage position setting 0. P068 Zero return mode selection. P069 Zero return direction selection. P070 Low speed zero return frequency. P071 High speed zero return frequency. Page 7 of 8

7 OTHER CONSIDERATIONS 7.1 Position Range For positioning range, the positioning mode selection (P075) must be set to 0, positioning with limitation. The position range, can be changed on the parameters P072 and P073, where P072 corresponds to the position range specification (forward) and the parameter P073 corrersponds to the position range specification (reverse). This program does not support wraparound (infinite relative movements). Position range from -268435455 to +268435455. 7.2 Encoder disconnection Error An E80.* error will appear for encoder disconnection error. Set the encoder disconnection timeout value on the parameter P077 in seconds. Page 8 of 8