Specification DataFile

Similar documents
ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

ULTRA TWIN INSTRUCTION MANUAL

ULTRA 5 INSTRUCTION MANUAL

LST400 Ultrasonic level / open channel flow transmitter

LST100 Ultrasonic level transmitter for upstream oil and gas

ULTRASONIC LEVEL INDICATOR

Conductivity Analyzer

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

Multi-electrode Conductivity Analyzers

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Sultan Liquid- Acoustic Wave Technology

Sarasota CM200 Sarasota HME900 Density Converter Electronics

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Instruction Manual for Measurement Transmitter NivuMaster Ultra Series

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

SITRANS L Level instruments

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

ChuteMaster Microwave-blocked chute detection and point level instrument

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

Model Sono-Trak Transit Time

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Improve asset protection and utilization

Electromagnetic Flowmeter Hygienic/Sanitary

Advanced, accurate and intelligent monitoring for your transformer

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

Ultrasonic level transmitter, non-contact

Level Measurement Continuous level measurement Radar transmitters

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Ultrasonic Liquid Level Transmitters

U Series Non-Contact Ultrasonic Transmitter

KOBOLD EchoKing NEO-5003 Series Ultrasonic Level Transmitter User Instructions KOB

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

ABB Instrumentation. Flowmeter. Specification DataFile

Level Measurement Continuous level measurement Radar transmitters

2-wire level transmitter

Sultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.

Various Technics of Liquids and Solids Level Measurements (Part 4)

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

Submersible pressure sensor For water and wastewater Model LW-1

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

prosonic T FMU230, FMU231

Temperature transmitter itemp PCP DIN rail TMT 121

Ultrasonic Level Transmitter.

LPU-2127 User Manual

SITRANS LR 300: High Performance Radar for Level Measurement

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

High Performance Process & Temperature Controllers

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Electro-Magnetic Flowmeters COPA-XE

WHITE PAPER HOW TO SELECT A CONTINUOUS LEVEL SENSOR BINVENTORY. Jenny Christensen Todd Peterson. BinMaster

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Instruction Manual Ultrasonic Level Meter Model: NUS

Submersible pressure sensor For oils and fuels Model LF-1

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

Electromagnetic Flowmeter

02/11/2015

MK372/Ultrasonic Sensor System. Installation & Setting up Instructions. Comprising. MK372 Indicator/Controller Ultrasonic Transmitter

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

FlowCERT INSTRUCTION MANUAL

Sultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.

SAPLING WIRELESS SYSTEM

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Electromagnetic flowmeters and switches DWM 1000/2000

Excellent low-cost Process & Temperature Controllers

Rosemount 3101, 3102, and 3105

02/11/2015

Process display RIA 261

Connecting Mains Electrical Power

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Two-Wire Programmable Transmitter for:

Signet 9950 Dual Channel Transmitter

Level Measurement silometer FMX 570

Mobrey open channel flow measurement systems

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

CONTENTS Page 1 INTRODUCTION SUPPLEMENTARY INSTRUCTIONS TO BOOK 3 ELECTRICAL INSTALLATION Section Page 1 INTRODUCTION The cable supplied with your Mag

B850 Boiler House Energy Monitor

UTM10 Series Ultrasonic Transit-time Flowmeters

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Non-Submersible Industrial Pressure Transducer

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

Transcription:

DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming obstructions in your tank pre-programmed tank shapes easy to configure for volumetric level, menu driven Isolated analog output and five alarm relays extras built-in as standard High accuracy and resolution measurement accuracy 6mm (. in.) or.5% of measurement range with resolution to mm (.8 in.) or.% of measured range Wall-mounted, IP65 enclosure ideal for wet and hose-down areas Configurable via a PC RS port for connection to PC Configurator DATUM U the only ultrasonic level system you will need Temperature compensation as standard for improved accuracy with varying temperatures Auxiliary analog input additional input for alternative measurement device

Datum U Ultrasonic Level System The DATUM U system provides non-contacting, maintenance-free level control and indication in liquids, slurry and solids. The DATUM U is the most versatile ultrasonic level measurement system available. It can be used in the diverse level measurement applications found in food, chemical, pharmaceutical, quarrying, power generation and many more industries. The unit has been designed for 'fit and forget' performance in advanced measurement and control routines (which include volume conversion with preprogrammed tank shapes). Pre-programmed Tank Shapes -point Custom Linearizer Multiple Alarm Functions Fill and Empty Control DATUM Ultrasonic Sensor Safe Area Zones and (U) Zone (U) Backlit LCD 6-digit + Text Bargraph Alarm Indication Configuration Flag x 5A Control Relays U 5 x 5A Control Relays U Auxillary Input -wire Transmitter to ma Isolated Retransmission RS PC Configuration Infrared Remote Configurator

Sensor Choice to Suit Application Any transducer from the DATUM range can be connected to the DATUM U System to meet the needs of diverse applications in different industries. The level controller,which must be mounted in a safe area, is available with transducers suitable for mounting in flammable atmospheres: DATUM U is suitable for Zone and Zone (EEX m); DATUM U extends the capability to Zone (EEx ia). Display A high-clarity back-lit l.c.d. is fitted as standard. This has a 6-digit level indicator, a -character text display and a bargraph with direction indicators. The clarity of the display makes reading the level easy and setup from the front of the unit is very simple using the integral keyboard. High Accuracy A small blocking distance of only mm (.8 in.) and a narrow beam angle of, give an overall accuracy of:.5% of measured range or 6mm (. in.), whichever is the greater and a resolution of:.% of measured range or mm (.8 in.), whichever is the greater Volumetric Conversion Conversion of level measurements into volumes is achieved using one of pre-programmed standard tank shapes or a user-defined shape created with the in-built -point custom linearizer. If you have different tanks on site you still only need to keep one unit as a spare. Configuration The DATUM U can be configured in one of three ways: the front panel via the integral keypad an external infrared communicator via a PC using the RS port All settings are password protected to prevent tampering. Isolated Outputs The DATUM U/U is fitted as standard with an analog output (either to ma or to ma) and a full duplex RS digital output for PC configuration. The U has and the U has 5 form 'C' (SPDT) volt-free contacts rated 5A at V a.c. Echo Processing The DATUM U utilizes in-built 'DATEM' technology (Digital Adaptive Tracking and Echo Mapping). This technology has been developed to give the DATUM range the advantage when identifying the 'true target level' where there are obstructions in whatever vessel you are measuring. Hot Keys There are 'Hot Keys' on the keypad which are used to view parameters (e.g. pump usage, signal strength) quickly whilst in the run mode. This also enables an operator or engineer to display the level in different units. ma Echo confidence/echo strength/average noise/ peak noise Instantaneous ma output Space/level/distance/rate of change of level Alarm Functions A number of standard alarm functions are included to simplify control of your plant and tell you when a problem has occurred. High or Low level In or Out of band Rate of Filling or Emptying High or Low Temperature System Failed Fill and Empty control (initiation and switch off) Auxiliary Input A second analog input is available for connection to other external to ma devices, enabling the DATUM U/U to work with other -wire level transmitters. Built to Last The wall-mounting version, protected to IP65 (NEMA) as standard, is housed in a tough, polycarbonate, flame resistant case making it ideally suitable for use in harsh industrial environments. Temperature Compensation As the temperature of surrounding air varies, its density also changes. Once a system is calibrated, any variation in air density also affects its accuracy. The transducer, with integral temperature compensation, takes these changes into account and modifies the calibration automatically. Power Supply The unit can be supplied suitable for either a 5V or V a.c. 5/6Hz power supply. As standard, a battery back-up facility is built-in to allow the unit to continue to operate in the event of a mains supply failure.

Applications to ma Tank Volume Hi Alarm Lo Alarm Rate Alarm The measurement of level in a tank can be one of the simplest applications (e.g. water in a vertical tank) or one of the most difficult (e.g. granules in a tank with cross struts). These applications are found in diverse industries such as solids manufacturing, pharmaceuticals and food & beverage. The DATUM U has been designed to work in any of these applications and can be used for simple indication of tank level or volume. The in-built conversion software with standard tank shapes makes setup quick and easy for almost any application. A -point linearizer for complex tank shapes is also included. Five alarm relays are provided as standard to advise the operator of any problems with the process, together with a retransmission signal for connection to a supervisory system. Application Tank Level to ma Output Pump Hi Alarm Hi Hi Alarm In all types of industry, from pharmaceutical to agriculture, measurement of solids (e.g. pellets or grain) in storage silos is necessary. With these types of application, the accuracy and repeatability of the measurement can be affected by dust in the atmosphere. Furthermore, the surface of the material is not normally level. The narrow beam angle and optional beam aiming kit enable the DATUM U to target an average point in the vessel and measure this point with excellent repeatability. Application Solids Measurement in Storage Silo

Applications Zone Hazardous Area Safe Area Zone to ma IS Application Pump Pump Pump The DATUM U & U are designed for use in hazardous areas; U in Zone / Zone (EEX m) and U in Zone (EEx ia). As standard, the sensors are certified and there is no need for external barriers just order the control unit relevant to your safe area. This makes the DATUM U/U ideal for use in Pharmaceutical and Chemical plants. No special cables are required (a standard twin-screened cable can be used) thereby reducing installation costs. Application IS Application to ma Output Pump Pump Hi Alarm In many applications, the use of stirrers is very common when mixing product in batches. These stirrers can cause ordinary ultrasonic units to give false readings. The DATUM U incorporates the 'DATEM' software which can map the profile of the tank and blank out any false echoes created by the stirrer or other pipework. Even the noise created by the filling process can be blanked-out, ensuring the operation of the DATUM U is not affected. Application Mixing 5

Applications to 5 = Level & Volume Breakpoints to 5 Max. Span & Max.Volume 5 % Span (Full) 8% Span Max. Volume 5 Volume 6% Span % Span 5% Span % Span (Empty) Level The level measurement is converted to volume using one of the pre-programmed standard shapes. However, in some industries, different tanks have been designed for specific applications and these tanks are not included in the standard shapes. To overcome this problem, the DATUM U has a -point linearizer which allows the profile of the tank to be entered so that the volume of the tank can still be calculated. No matter what your requirements, the DATUM has the solution. Application 5 Non-standard Tank Shapes Specification Performance Accuracy.5% of measured range or 6mm (. in.), whichever is greater Resolution.% of measured range or mm (.8 in.), whichever is greater Max. range 6m (9.5 ft) (db6 transducers), m (.5 ft) (db transducer), 5m (8.75 ft) (db5 transducers) Min. range Dependent on transducer Reading response Fully adjustable Echo Processing 'DATEM' (digital adaptive tracking of echo movement) Outputs Analog output Isolated output of to ma or to ma into 5Ω (user programmable and adjustable).% resolution Digital output Full duplex RS Volt-free contacts Number U 5 form 'C' (SPDT) U form 'C' (SPDT) Rating 5A at V a.c. Display 6 digits plus -character text, plus bargraph with direction indicators, remote communication identifier and program/run/test mode indicators Analog Input to or to ma for pressure sensor, velocity sensor 6

Specification Programming Remote By optional infrared communicator On-board By integral keypad (Wall- or Fascia-mounting) PC programming Via RS port Programming security Via password (user-selectable and adjustable) Programmed data integrity Via non-volatile RAM, plus backup Power supply 8 to 6V d.c. included as standard with either 5V a.c. +5%, %, 5/6Hz or V a.c. +5%, %, 5/6Hz Physical Overall dimensions (wall-mounting version) x 85 x mm (9.5 x 7. x.7 in.) Weight Nominal kg (. lb) Overall Dimensions Case material/description Polycarbonate, frame resistant to UL9 (Wall-mounting) Transducer cable requirements Standard version: Twin-screened IS Version: -core screened Maximum separation 5m Cable entry detail Standard version Cable entry 'knock-outs', x PG, x PG9, x M underside, x PG at rear IS Version cable entry 'knock-outs', x PG, x PG9, x.5 underside, 5 x PG at rear Environmental IP rating (wall-mounting version) IP65 Max. & min. temperature (electronics) to 6 C ( to F) Flammable atmosphere approval Safe area: compatible with approved db transducers (see Transducer specification sheet, SS/USONIC) CE approval EMC approval to BS EN 58-:99 for emissions BS EN58-:995 for immunity BS EN6-:99 for low-voltage directive Dimensions in mm (in.) (.7) (9.5) Dimensions in mm (in.) 6 (6.) HP [5 (.97)] 85 (7.8) U [8.5 (5.6)] 8 units to a standard 9-inch rack Wall-mounting Version Rack-mounting Version Dimensions in mm (in.) Dimensions in mm (in.) 76 (6.9) 7 (.8) 5 (.59) 7 (.8) 6 (.6) (7.87) (5.67) (.) Panel-mounting Version Fascia-mounting Version 7

Ordering Information Transducer Code see SS/USONIC for further information DATUM UX Series Ultrasonic Level System Build Standard Version I.S. Version Mounting* None Wall-mounting Panel-mounting Rack-mounting Fascia-mounting Case Style Rack IP65 (Wall-mounting only) Standard (Panel-mounting only) IP65 (Panel-mounting only) IP6 (Fascia-mounting only) Keypad None Yes (Wall-/Fascia-mounting only) Power Supply V, 5/6Hz 5V, 5/6Hz Accessories None Communicator Infrared Remote Control * Note. The U is only available in a Wall-mounting format. UF/ P U X X X X X X The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB Printed in UK (.) SS/U Issue ABB Automation Ltd Oldends Lane, Stonehouse Gloucestershire, GL TA UK Tel: + ()5-86-66 Fax: + ()5-87-856 ABB Automation Inc 5 E. County Line Road Warminster, PA 897 USA Tel: + 5-67-6 Fax: + 5-67-78 ABB has Sales & Customer Support expertise in over countries worldwide www.abb.com/automation 8