Digital Indicator DS 96/24

Similar documents
Digital Indicator DS 96/48 PK

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

MODEL: 47LV. Digital Panel Meters 47 Series

Adjustable Digital Process Instrument MDK480

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

TZIF 4. Current-to-Pulse Converter 10/ EN

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

TS05 Input Functional description Output Deviation 0.15 % Electrical isolation Programming of the measuring range via push-button

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

DIGEM f 96 x 48 EK. Applications. Description

Rail mounted Temperature Transmitter TH102/TH102-Ex

Process displays For standard signals, temperature, resistance measurement

Head mounted Temperature Transmitter TF02/TF02-Ex

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

ChuteMaster Microwave-blocked chute detection and point level instrument

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Three-phase monitoring relay CM-PVE

ControlMaster CM15 Universal process indicator 1 /8 DIN Custom configuration sheet

Three-phase monitoring relays CM-PFE and CM-PFE.2

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

LINAX 4000L Continuous-line recorder

FieldIT Temperature Transmitter, head mounted TH02/TH02-Ex

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

[3] MOUNTING DIRECTION

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

Digital indicator for panel mounting With multi-function input Model DI25

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

FieldIT Temperature Transmitter, field mounted TH202/TH202-Ex

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Power supply CP-D 12/2.1

Position Transmitter TGS 40 (RAM)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Model 264IB. ABB 2600T Series Engineered solutions for all applications

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

METRATESTER 5+ Tester for DIN VDE /6.15

Power supply CP-T 48/20.0 Primary switch mode power supply

MODEL: W2TS. Mini-MW Series

Light-strip indicator

Technical Description. Wireless Proximity Switches Antenna WAT100

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

MODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Three-phase monitoring relay

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Electronic Products and Relays Selection Table Measuring and Monitoring Relays CM-Range

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Power supply CP-T 24/20.0 Primary switch mode power supply

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Digital panelmeter with microprocessor based technology 5 digit. 4 free scalable setpoints/hysteresis/delay time (option)

Pluggable interface relays CR-U Universal relays

Three-phase monitoring relays CM-PVS.81

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

CONTA-ELECTRONICS. Converter Units

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX / EURAX 2I1 Passive DC signal isolator

Multimeter 500CVD21 RTU500 series

Electronic timer CT-SDS.22

Technical Description. Wireless Automation Input/Output Module WDIO100

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Liquid level monitoring relay CM-ENS.2x

SINEAX TI 807 Passive DC signal isolator

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

MODEL: M2VF MODEL: M2VF [1][2] [3][4]

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-T 48/5.0 Primary switch mode power supply

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

VariTrans P V. Safe and Sound.

Electronic Thermostat TE-1 Version according to EN

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

JUMO dtrans T02 LCD programmable transmitter. B Operating Instructions 10.00/

Three-phase monitoring relay CM-PFS

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors for Cellpack separable connectors

LST100 Ultrasonic level transmitter for upstream oil and gas

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

48x48. Digital panel meter 3½-digit DV3, DT3. Without setpoints. Analog output

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

Coupling Relays and Converters

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

JUMO di 32 / di 08. Brief description. Block structure

Transcription:

Data Sheet 10/33-2.11-EN Digital Indicator DS 96/24 This indicator is suitable for measuring direct voltage or direct current. By using potentiometers, the digital display can be assigned to any input signal. The main application is therefore the display of process variables produced as transmitter signal.

DS 96/24 Digital indicator 10 /33-2.11 EN Technical data Description The indicator can be built into any conventional grid system. Alter removing the front mask, the entire range of the numerical final value and the initial numerical value within the ± 25 % range can be changed from the front. The initial signal 0...20 ma to 4...20 ma and vice versa can also be changed over from the front by using a solder jumper. Readout Display LED, 10 mm high, colour red Maximum reading ± 1999 digits Minimum reading 200 digit Deviation (23 C) 0.05 % of measured value ± 1 digit Temperature coefficient 0.01 % / of final value / C Overflow indication -1 Segment test Retrace display blanking Display storage Input Measuring method Dual slope, measuring sequence 2.5 /s Limits of measuring range Direct voltage ± 2 V min.; ± 40 V max. Direct current ± 1 ma min.; ± 50 ma max. Input resistance > 1 MΩ at 2 V; 100 Ω at 20 ma Overload rating 100 V at > 2 V; 5 V at 2 V Suppression of parasitic voltage SMR > 40 db (50 Hz) CMR > 100 db (0...50 Hz) Modification of the display range using potentiometer Initial value Z-17535 EN Power supply Direct voltage 24 V (18...32 V) with electrical isolation Ripple 1 V max. (peak-to-peak) Alternating voltage 24 V ± 10 % Frequency range 48...62 Hz Power consumption Approx. 2.8 W at 24 V DC Approx. 2.8 W at 24 V AC General and safety data Test voltage As per DIN VDE 0411/IEC 384 Insulation group C, acc. to DIN VDE 0110 Environmental capabilities Category KWF acc. to DIN 40040 Operating temperature 0...50 C Transportation and storage temperature -40...+75 C Relative humidity 75 % on annual average, no condensation Case and mounting Dimensions See dimensional drawing Mounting Panel or grid (H&B unibloc, Kreutzenbeck, Mauell, Subklev, Siemens) Close-packed assembly is not permitted without external ventilation Material Plastic Colour of bezel black Type of protection Case IP 50; terminals IP 20 Weight Approx. 0.25 kg Final value coarse fine Adjustment limits Initial value: ± 25 % End value: ±1999 digits Example: Readout Setting range Start 400 C 300...500 C End 1200 C ±1999 C Page 2 of 4

DS 96/24 Digital indicator 10 /33-2.11 EN Connection diagram, dimensional drawing Connection diagram Dimensional drawing (dimensions in mm) Panel cutout 10 9 8 7 6 5 4 3 2 1 95,4 90 +0, 8 Power supply L1(AC) / +(DC) 23,4 18 +0, 3 Power supply N(AC) / -(DC) Input (+) Input (-) Segment test Display blanking 114 109 61 90 Display storage Reference to 7-9 control via potential-free contact) Z-13403 EN Z-13384 EN 04.02 Page 3 of 4

DS 96/24 Digital indicator 10 /33-2.11 EN Ordering information Catalog No. Code EUR Deliv. time Digital indicator DS 96/24 V33142A- 1 0 0 3 wks. Measuring input 0...20 ma resolderable to 4...20 ma 1 153,00 ** 4...20 ma resolderable to 0...20 ma 2 153,00 ** 0...2 V 3 153,00 ** 0...20 V 4 153,00 ** other (Code No. 326) 0 153,00 ** specify readout range using Code No. 361 Decimal point position.000 1-0.00 2-00.0 3 - without 4 - externally adjustable 9 - Power supply 24 V DC 1 67,00 ** 24 V AC 3 96,00 ** Display control without 0 - Display storage 1 17,00 ** Retrace blanking display 2 21,00 ** additional permanent zero behind 3 28,00 ** Specialities other measuring range (consider alarm data) (clear text) 326 33,00 ** Display range other than measuring range (clear text) 361 23,00 ** Dimension according to table (clear text) 368 - Dimension as required (max. 5 characters) (clear text) 369 17,00 ** reduced measuring rate (1...10 s) (clear text) 533 49,00 ** special lettering (max. 10 characters) (clear text) 566 25,00 ** Bezel grey RAL 7037 568 17,00 ** Rack mounting H&B Unibloc 571 - Mauell 572 - Kreutzenbeck 573 - Subklew 574 - Siemens 575 - Operating Manual 1) German Z1D 5,00 English Z1E 5,00 1) 1 copy in German included in the basic supply; no specification required; extra Operating Manuals must be paid (please specify number) Dimensional labelling Code Code Code Code Code Code Code none 400 kw 406 A 412 MN 418 m 3 424 N 430 ppm 436 V 401 MW 407 ma 413 % 419 g 425 bar 431 K 437 mv 402 Ω 408 µa 414 420 kg 426 m/min 432 l/h 438 kv 403 mω 409 C 415 cm 421 t 427 U/min 433 t/h 439 mw 404 kω 410 416 mm 422 m 3 /h 428 δ 434 Hz 440 W 405 MΩ 411 kn 417 m 423 ph 429 mbar 435 ABB Automation Products GmbH Hoeseler Platz 2 42579 Heiligenhaus, GERMANY Phone +49 2056 12-5181 Fax +49 2056 12-5081 http://www.abb.com Technische Änderungen vorbehalten. Printed in the Fed. Rep. of Germany 10/33-2.11 EN 04.02

Contact us ABB Ltd. Process Automation Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Phone: +44 (0)1480 475321 Fax: +44 (0)1480 217948 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 18974 USA Phone: +1 215 674 6000 Fax: +1 215 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2011 ABB All rights reserved 3KXJ300001R1001 10/33-2.11-EN 01.2011 ABB Automation Products GmbH Process Automation Borsigstr. 2 63755 Alzenau Germany Phone: +49 551 905-534 Fax: +49 551 905-555 www.abb.com