Flashlink CWDM Add & Drop Module

Similar documents
DWDM-40C. User manual. 40-ch 100GHz Dense Wavelength Division Multiplexing System. Rev. A

EDFA-B-C 17dBm. User manual. SDI optimized Erbium Doped Fiber Amplifier. Rev. D

Solid State Relays Industrial, 1Phase Peak Switching Type RM1C

AME 140X. ENGLISH Actuators for modulating control AME 140X Page 5. Operating Guide. Danfoss VI.IR.A2.02 1

INSTRUCTIONS MODEL AVX-TFR-STUD TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

INSTRUCTIONS MODEL AVX-S1-P0D-MS1A PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

DF-LDL2-41X16. CCS Inc Copyright(c) 2009 CCS Inc. All rights reserved. Reproduction or photocopy without permission is prohibited.

WaveSmart Wave Division Multiplexing (WDM)

1480nm Pump Laser Diode Module Component Specifications (with Isolator, RoHS6/6)

GL480E00000F. Infrared Emitting Diode GL480E00000F. Features. Agency Approvals/Compliance. Applications

Narrow Linewidth Full Band Tunable DFB Laser Module. Component Specifications

GL100MN0MPx. Surface Mount Type, Infrared Emitting Diode. GL100MN0MPx. Agency Approvals/Compliance. Features. Model Line-up.

Distance Measuring Sensor Unit Measuring distance : 4 to 30 cm Analog output type

Analog & Digital I/O Wireless Bridge USERS MANUAL R02

Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products (SJ/T )

PT480FE0000F. Phototransistor PT480FE0000F. Features. Agency Approvals/Compliance. Applications

DEP 001. Operation Manual

PSC Power Paddle II Antenna

GL4800E0000F. Infrared Emitting Diode GL4800E0000F. Features. Agency Approvals/Compliance. Applications

Gap : 5.0mm, Slit : 0.5mm, Low voltage operation, *OPIC Output, Snap-in type Compact Transmissive Photointerrupter with connector

Gap : 1.7mm, Slit : 0.3mm Phototransistor Output, Compact Transmissive Photointerrupter

Model OT-DCM-Fxx. Dispersion Compensation Module

PSC Power Paddle Antenna

CA92009-O O Band (1260 ~ 1360 nm) Tunable Laser Source

PT480E00000F. Phototransistor PT480E00000F. Features. Agency Approvals/Compliance. Applications

2018 Liquid Solder Flux RoHS Product Certificate of Compliance

User Manual. Portable C-band 26dB-gain EDFA Instrument in compact benchtop. (EDFA-C-26G-S, version 1.0b. January 28, 2015) Fiberprime, Inc.

Mi Motion-Activated Night Light. User Manual

GP2Y0AH01K0F. High-precision Displacement Sensor Unit Measuring distance: 4.5 to 6.0 mm Analog output type GP2Y0AH01K0F

Materials Declaration

The SCX18.S provides dual high power regulators capable of supplying 3A to the connected servos from an external Li-Pol or

SatellitePlus Model OLMT. Mini L-Band Transmitter. 10-3,600 MHz OPERATING MANUAL

3M Ground Pro Ground Integrity Meter

FOM-5A, 6A Asynchronous Fiber Optic Modems

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

Chromadigm CHS/CHQ Transmitter

SANway Optoelectronics technology Corporation Tel: Fax: Website :

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

CCS Inc. 4-M3(screw hole for securing) (16) (16)

PT4800FE000F PT4800FE000F. Opaque Resin, Medium Directivity Angle, Thin Package Phototransistor. Features. Agency Approvals/Compliance.

SST-05-IR-850nm. Surface Mount Series. Infrared LED. SST-05-IR-850nm Product Datasheet. Features. Table of Contents. Applications

Data Sheet AMMC KHz 80 GHz TWA. Description. Features. Typical Performance (Vd=5V, Idsq=0.1A) Component Image.

Gap : 5.0mm Slit : 0.7mm Phototransistor Output, Compact Transmissive Photointerrupter with connector

Industrial, 2-Pole ZS Type RA2A

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

Description. Applications CATV Return-path Analog transmission. DFB-1xxx-C5-2-A-xx-x-x-xx REV 014 APPLIED OPTOELECTRONICS, INC.

USER MANUAL. MODEL 3P-MF and 3P-MF9 DB-25 and DB-9 In-Line Power Supply Adapters SALES OFFICE (301) TECHNICAL SUPPORT (301)

Gap : 5.0mm Slit : 0.5mm *OPIC Output, Snap-in type Compact Transmissive Photointerrupter with connector

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

Wave Bluetooth Music Adapter

Description. Applications CATV return path CWDM narrowcast and point-to-point applications. DFB-1XXX-BF-xx-A1-xx Laser Module REV 016

HFC. Enhance. QFHPN High Power Optical Node with AGC Installation & Operation Guide

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

Narrow Linewidth Micro- Integrable Tunable Laser Assembly u ITLA

Types MCM and MIN SMT Clad RF Capacitors

Types MCM and MIN SMT Clad RF Capacitors

Instruction Manual RT-93285SL RR-93285SL Thirty-two Channel Video Multiplexer With Two Bi-directional Data Channels

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

COTS EMI FILTER -500V

SYSTEM DEVICE UNIT ELECTRONIC COMPONENTS AND DEVICES DIVISION SHARP CORPORATION SPECIFICATION PHOTOCOUPLER PC817. Business dealing name PC817XNCSP9F

HUAI YANG CO.,LTD. Technical Data Sheet- Light Transmitting Unit DATA LINK : DLT11M1

Structure 4. Power supply 6. Way of connecting 7. Setting ATTENUATION and BOOST regulators 11. Mounting 12. Technical parameters 13

Document # Rev. C October, GEMINI EXPRESS MULTIPLEXER User s Guide

APPROVAL SHEET. Issued Date Dept. R&D R&D QM. Name JungHwan, Park Namjun, Kim Juwon, Park

BRIDGELUX BLUE POWER DIE BXCD 45 x 45

MODULATION LIGHT SOURCE FOR DWDM APPLICATIONS

Materials Declaration

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

PC3H4J00001H Series. Mini-flat Half Pitch Package, AC Input Photocoupler

REFERENCE PC817X*CSZ9F. Product name : PHOTOCOUPLER. Model No. : PC817 PC817XNCSZ9F PC817X1CSZ9F PC817X2CSZ9F PC817X3CSZ9F PC817X4CSZ9F

Case Type With Encoder Function Digital 2 Output (A Phase / B Phase) Transmissive Photointerrupter

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

Wave Division Multiplexing. Passive Mux/Demux Modules & Cables. Datasheet. Features. Overview. Typical 2-Channel Passive Mux/Demux Application

Model 608A10. Industrial ICP Accelerometer. Installation and Operating Manual

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Add/Drop Multiplexor/Demultiplexor

Optiva 18 GHz Unamplified Microwave (MW) Transport System

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

Table 1: Pb-free solder alloys of the SnAgCu family

Rosemount Wireless Dam Monitor (WDM)

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

SPLIT.CONVERTER. User's Manual. Version 2.0

SCXI MHz Quad 8x1 50 Ω Multiplexer

SANway Optoelectronics technology Corporation Tel: Fax: Website :

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

Distance Measuring Sensor Unit Digital output (150 mm) type

Model TLD356M155 TRIAXIAL ICP ACCELEROMETER. Installation and Operating Manual

Table of Contents. Stabila LD 320 1

3M Shrunk Delta Ribbon (SDR) Cable Assembly.80 mm High Speed Digital Data Transmission, 26 position 1MG26-LFW0-00C-XXX

GP2S700HCP. SMT, Detecting Distance : 3mm Phototransistor Output, Compact Reflective Photointerrupter. Description. Agency approvals/compliance

Model 333B52. Modal array, ceramic shear ICP accel, 1000 mv/g, 0.5 to 3k Hz, side. Installation and Operating Manual

NI PXI-2557 Specifications

CS Series. Compact, Cost-effective, High Reliability Switching Power Supply. TDK-Lambda Introduces CS series

ML-COAX-X-DFB-2G5-X-X-2. CWDM COAXIAL FIBER PIGTAILED DFB LASER FOR 2.5 Gb/s DFB DIGITAL APPLICATIONS

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Model 621B40. Very High Frequency ICP Accelerometer. Installation and Operating Manual

Please let us know if you have any questions.

WaveReady CWDM Add/Drop for OSP Splice Enclosure

Transcription:

Flashlink User Manual WDM-C1xxx Flashlink CWDM Add & Drop Module network-electronics.com Rev. 3

Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 E-mail: support@network-electronics.com www.network-electronics.com Service Phone: +47 90 60 99 99 Revision history Current revision of this document is the uppermost in the table below. Revision Replaces Date Change description 3 2 2007-10-30 New front page and removed old logo. 2 1 2007-10-17 AS: Added Materials Declaration and EFUP 1 0 23/01/06 RS: New WDM-C1xxx module, with new features. 0-02/01/04 RS: Initial Revision 2

Contents Revision history... 2 1 Product overview... 4 2 Specifications... 5 2.1 Optical specifications...5 2.2 Electrical specifications...5 3 Configuration... 6 3.1 Mounting the module...6 3.2 Applying signals to the module...6 4 Module status... 8 5 Application examples... 9 5.1 Single fibre CWDM add/drop multiplexer...9 5.2 CWDM add/drop multiplexers for a fibre pair...9 5.3 All-optical SDI contribution network with CWDM add-drop multiplexing...9 6 Laser safety precautions... 11 General environmental requirements for flashlink equipment... 12 Certificate of Conformity... 13 Product Warranty... 14 Materials declaration and recycling information... 15 Materials declaration... 15 Recycling information... 15 3

1 Product overview Figure 1: Block diagram of the CWDM add/drop module operation. The flashlink WDM-C1xxx is an all-optical CWDM add and drop multiplexer for a single CWDM channel. The unit is passive and there is no need for power or control. The add and drop CWDM wavelength is chosen according to ITU-T G.694.2, with wavelengths from 1270 to 1610nm. Typical applications are single channel wavelength management in an optical ring structure. The content of a single CWDM wavelength can be replaced or re-generated at the ADMnodes throughout the ring giving increased flexibility in optical network design. A typical broadcast application can be a centralised studio with fibre connection to different local production facilities, each facility being assigned a dedicated wavelength. The received content is taken through the drop-port, whereas the transmitted content is passed to the ring via the add-port. 4

2 Specifications 2.1 Optical specifications Optical centre wavelengths: Optical band pass: Channels: Transmission circuit fibre: Connector: Return loss: Insertion loss, passing wavelengths: Insertion loss, add or drop channel: 1471, 1491, 1511, 1531, 1551, 1571, 1591 or 1611nm (red band) 1271, 1291, 1311, 1331, 1351, 1371, 1391 or 1411nm (blue band). Minimum 13nm. 1 add + 1 drop. Single Mode 9/125um. SC/UPC. Better than 40dB with Single Mode fibre. < 2.5dB incl. connectors (<2dB typical). < 2.5dB incl. connectors (<2dB typical). Isolation: > 30dB (adjacent channel at drop port), > 40dB (non-adjacent channel at drop port). Isolation, add channel: > 50dB (add channel at drop port) > 40dB (drop channel at out port). Directivity: > 50dB. Polarisation dependent < 0.2dB. loss: Maximum optical power: 250mW. Operating temperature: 0 70degC. 2.2 Electrical specifications Power: Control: None. None. 5

3 Configuration The WDM-C1xxx is a self-contained module that is mounted from the back of the flashlink frame, and fixed with 4 screws. Figure 2: Configuration of the connector module, ports 5-10 are not in use. 3.1 Mounting the module This section only applies if the module is not purchased pre-mounted in a subrack. In general we refer to the user manual for the sub-rack frame FR-2RU-10-2. This manual is also available from our web site: http://www.network-electronics.com/ No preparation is needed for the module itself. The blank in the corresponding position of the flashlink frame must be removed. The factory default position for this module is position 1 in the frame (the leftmost position as seen from the front). Slide the module carefully into position, make sure that the module enters both upper and lower guiding rails. Care should be taken to preserve the EMC-shielding at the connector module for this as well as for neighbouring modules. Fix the module with the 4 off M2.5x8 stainless steel screws enclosed and apply signals to the corresponding ports as described in section 3.2. 3.2 Applying signals to the module Signals are applied on a per wavelength basis. The term wavelength, refers to the add/drop wavelength for the respective module. 6

The input and output ports shown in figure 2 are the connections to the main fibre, to maintain traffic on the other wavelengths. The add port is used to feed the wavelength onto the main fibre, whereas the drop port is used to drop the wavelength content from the common fibre. The optical interface on the module is SC/PC, SC/SPC or SC/UPC connectors. 7

4 Module status The WDM-C1xxx is an all optical module with no electrical connections; hence there will be no on-board processing or monitoring. If the module is faulty this can be monitored on the receiver end. The only possibilities for the module to fail are if either one or more fibres are broken, or the fibre connections at the rear are bad. The WDM-C1xxx is an all optical module, so there are no LED's on the module. (Text not printed on the front panel). Figure 3: The WDM-C1xxx has no LED s. 8

5 Application examples The WDM-C1xxx is the building block of all-optical photonic networks based on CWDM. We will in this chapter show some examples of how the module can be used. Since the module is all-optical; any signal format can be applied. 5.1 Single fibre CWDM add/drop multiplexer Having both add and drop functionality, the module can be used to add, drop or add and drop CWDM wavelengths on an optical fibre. This is shown in figure 4. Figure 4: Single fibre CWDM add/drop multiplexer 5.2 CWDM add/drop multiplexers for a fibre pair Dark fibre providers will normally provide a pair of fibres, in this case two modules are needed to give full add/drop functionality fibre pair. SDH/SONET traffic is bi-directional, using normally one fibre per direction. This is shown in figure 5. Figure 5: A CWDM add/drop multiplexer for a fibre pair consists of two modules 5.3 All-optical SDI contribution network with CWDM add-drop multiplexing This example describes how multiple WDM-C1xxx can be used to build a very efficient contribution network based on all-optical CWDM add-drop multiplexing. Up to 8 different sites are connected to a main studio, 3 of which are shown in figure 6. 9

Each site communicates with the main studio on a dedicated wavelength on the fibre. The site receives content from the main studio and transmits content to the main studio on the same wavelength, but in different directions on the fibre ring. The main studio has two 8-channel CWDM systems operating, one CWDM-8 to transmit e.g. SDI content to the sites, and another CWDM-8 to receive the SDI contribution signals from the different sites. On the electrical side, the control of the signals paths are taken care of by a VikinX router at each site and in the main studio (not shown in the figure). Note that the passing wavelengths will be attenuated by approx. 2.5dB through a module, so a power adjustment of the add wavelength can be necessary to avoid adjacent wavelength crosstalk. For longer signal paths, the optical transmission budget can be extended by a full 3R-regeneration performed by the MR-TR, SDI-TR or MR-TR-2,5G cards. Figure 6: Broadcast contribution network based on CWDM with add/drop multiplexing of single wavelengths throughout the network Being the building block of all-optical photonic networks, means that the WDM-C1xxx can be used in a variety of applications. 10

6 Laser safety precautions Guidelines to limit hazards from laser exposure. All the available EO units in the flashlink range include a laser. Therefore this note on laser safety should be read thoroughly. The lasers emit light at 1270 nm or 1620 nm. This means that the human eye cannot see the beam, and the blink reflex cannot protect the eye. (The human eye can see light between 400 nm to 700 nm). A laser beam can be harmful to the human eye (depending on laser power and exposure time), therefore: Note! BE CAREFUL WHEN CONNECTING / DISCONNECTING FIBRE PIGTAILS (ENDS). NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER/FIBRE. NEVER USE MICROSCOPES, MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A FIBRE END. USE LASER SAFETY GOGGLES BLOCKING LIGHT AT 1310 nm AND AT 1550 nm. Instruments exist to verify light output power: Power meters, IR-cards etc. Flashlink features: The FR-2RU-10-2 is classified as Class 1 laser product according to EN 60 825-1:94/A11:96, and CFR Ch1(1997) Part 1040.10. If the front panel is removed, the FR-2RU-10-2 is classified as Class 1 laser product according to EN 60 825-1:94/A11:96, and class IIIb according to CFR Ch1(1997) Part 1040.10. Maximum output power: 5 mw. Operating wavelengths: >1270 nm. < 5mW >1270nm 11

General environmental requirements for flashlink equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: - Operating room temperature range: 0 C to 50 C - Operating relative humidity range: < 90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: - Temperature range: -10 C to 55 C - Relative humidity range: < 95% (non-condensing) 3. Electromagnetic compatibility conditions: - Emissions: EN 55103-1 (Directive 89/336/EEC) - Immunity: EN 55103-2 (Directive 89/336/EEC) 12

Certificate of Conformity Network Electronics ASA N-3204 Sandefjord Norway Company Registration Number: NO 976 584 201 MVA Declares under sole responsibility that the product: Product Name: WDM-C1xxx Product Description: flashlink CWDM add & drop module To which this declaration relates are of Norwegian origin and are in conformity with the following standards: EN 55103-1: 1996 EN 55103-2: 1996 Generic Emissions Standard Generic Immunity Standard 13

Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Network Electronics ASA. These conditions are available on the company web site of Network Electronics ASA: www.network-electronics.com 14

Materials declaration and recycling information Materials declaration For product sold into China after 1st March 2007, we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. Toxic or hazardous substances and elements 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) WDM-C1xxx 0 O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. This is indicated by the product marking: Recycling information Network Electronics provides assistance to customers and recyclers through our web site http://www.network-electronics.com. Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Network Electronics or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labelled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices. 15