SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

Similar documents
6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

Product type designation. General information. Supply voltage

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

General information. Supply voltage

CPU 314C-2 PTP. Function

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

General specifications and features

Data sheet CPU 313SC (313-5BF13)

SM 1222 DIGITAL OUTPUT MODULE

2A (recommended) Power loss

Data sheet CPU 013C (013-CCF0R00)

SM 1223 DIGITAL INPUT/OUTPUT MODULE

FM HIGH-SPEED BOOLEAN PROCESSOR

FM COUNTER MODULE

FM COUNTER MODULE

Zentralbaugruppen CPU 222

PLC-K506 Series FEATURES DESCRIPTION FEATURES

FM 355 CONTROLLER MODULE

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

FM COUNTER MODULE

FM POSITIONING MODULE

em4 local - Robust Specific characteristics Part number

02/11/2015

EXM INPUT/OUTPUT EXPANSION

em4 em4 alert em4 alert 2G

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

SIMATIC S7-300 Function modules

02/11/2015

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

02/11/2015

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Custom "Compact" range with display CD20 Custom Part number

Overcurrent Protection / 7SJ45

02/11/2015

02/11/2015

General information. CiR - Configuration in RUN

This data sheet is only valid in association with the IL SYS INST UM E user manual.

02/11/2015

Lexium integrated drives

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

08/07/2015

SEN TRONIC AG. Millenium 3 Essential. Essential range: powerful but cost effective. Part numbers. Accessories

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

Order number 031-1BB BB BB BD30 Figure. SM 031, AI 2x12Bit I. Note - - Coming soon - Features. 2 inputs, Current 0(4)...

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

CP-T range Product group picture

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

QUINT-PS-24DC/24DC/10

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

05/09/2012

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Switching power supplies CP range, Linear power supplies CP-L range. Content

Type CP-S, CP-C & CP-A Switch mode

Pulse Scaler for DIN Rail Attachment

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

CP-T range Benefits and advantages

B850 Boiler House Energy Monitor

S200 I/O System Units

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

WAGO Application: Plastic Technology Center (SKZ) in Würzburg, Germany

20 General technical data XI/ON

Introduction DIN rail mounted electricity meters

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current

Industrial Modbus I/O Modules

B850 Boiler House Energy Monitor

Multifunctional counter tico 772/773/774

Totalizing Counters mini-i

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Electronic timer CT-TGD.22

PHOENIX CONTACT - 09/2009

Product Information. Release 3 4 SIMATIC ET 200S. 4DI UC V High Feature Digital Electronic Module

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

General information. CiR - Configuration in RUN

Power supply CP-T 48/5.0 Primary switch mode power supply

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Q.raxx A101-8 slimline RS / EC

C B. Models. Models 2MOPP

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

NPN PNP NPN PNP NPN PNP

Temperature Transmitters - Head Mounted

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

PFXLM4B01 D * * (1) (2) (3) (4)

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

Position Indicator with/without Limit Values

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Transcription:

6ES7212-1AD30-0XB0 Page 1 Product data sheet 6ES7212-1AD30-0XB0 SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 25 KB Product status associated programming package STEP 7 Basic V10.5 Supply voltages Rated value DC 24 V permissible range, lower limit (DC) permissible range, upper limit (DC) Short-circuit protection Load voltage L+ Rated value (DC) permissible range, lower limit (DC) permissible range, upper limit (DC) Current consumption Current consumption, max. Inrush current, max. Current output to backplane bus (DC 5 V), max. Current consumption/power loss Power loss, typ. Memory Usable memory for user data RAM integrated expandable Backup present without battery CPU/blocks 20.4 V 28.8 V 0.0000000000000000E+00 24 V 20.4 V 28.8 V 1.2 A ; 24 VDC 12 A ; 28.8 VDC 1000 ma ; 5 VDC max. for SM and CM 9 W 25 kbyte 25 kbyte No ; entire project maintenance-free in the integral EEPROM

6ES7212-1AD30-0XB0 Page 2 OB Number, max. CPU/processing times for bit operations, min. for word operations, min. for floating point arithmetic, min. Data areas and their remanence Retentive data area in total (incl. times, counters, flags), max. Flag Number, max. Address area I/O address area I/O address area, overall Inputs Outputs Process image Inputs, adjustable Outputs, adjustable Digital channels integrated channels (DI) 8 integrated channels (DO) 6 Analog channels Number of integrated channels (AI) 2 Number of integrated channels (AO) 0 Hardware config. Number of modules per system, max. Time Clock Hardware clock (real-time clock) Backup time Limited only by RAM for code 0.1 µs ; / instruction 12 µs ; / instruction 18 µs ; / instruction 2048 byte 4 kbyte ; Size of bit memory address area 1024 bytes for inputs / 1024 bytes for outputs 1024 byte 1024 byte 1 kbyte 1 kbyte 3 comm. modules, 1 signal board, 2 signal modules 240 h ; Typical Deviation per day, max. 60 s/month @ 25 C Test commissioning functions Status/control Status/control variable

6ES7212-1AD30-0XB0 Page 3 Variables Forcing Forcing Communication functions S7 communication supported as server Open IE communication TCP/IP ISO-on-TCP (RFC1006) Number of connections overall 1st interface Type of interface Physics isolated automatic detection of transmission speed Autonegotiation Product function / at the interface 1 / Autocrossover CPU/programming Configuration software Inputs/outputs, memory bits, DB, distributed I/Os, timers, counters 15 ; dynamically PROFINET Ethernet STEP 7 STEP 7 Basic V10.5 Programming language LAD FUP Cycle time monitoring adjustable Digital inputs Number of digital inputs of which, inputs usable for technological functions m/p-reading Number of simultanneously controllable inputs [nicht versorgt: TAK_ABP289_001_000] Number of simultaneously controllable inputs, up to 40 C 8 ; Integrated 4 ; HSC (High Speed Counting) 8

6ES7212-1AD30-0XB0 Page 4 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs programmable at " to "1", min. at "0" to "1", max. for interrupt inputs programmable Cable length cable length, shielded, max. Cable length unshielded, max. Digital outputs Number of digital outputs 6 of which, high-speed outputs Short-circuit protection of the output 24 V 5 VDC at 1 ma 15 VDC at 2.5 ma 1 ma 0.2, 0.4, 0.8, 1.6, 3.2, 6.4, and 12.8 ms, selectable in groups of four 0.2 ms 12.8 ms Limitation of inductive shutdown voltage to L+ (-48 V) Switching capacity of the outputs with resistive load, max. on lamp load, max. Output voltage for signal "0" (DC), max. for signal "1", min. Output current for signal "1" rated value for signal "0" residual current, max. Output delay with resistive load 500 m ; 50 m for technological functions 300 m ; For technological functions: No 2 ; 100 khz Pulse Train Output No ; to be provided externally 0.5 A 5 W 0.1 V ; with 10k ohms load 20 V 0.5 A 0.1 ma "0" to "1", max. 1 µs "1" to "0", max. 5 µs Switching frequency

6ES7212-1AD30-0XB0 Page 5 of the pulse outputs, with resistive load, max. 100 khz Cable length cable length, shielded, max. 500 m Cable length unshielded, max. 150 m Analog inputs Number of analog inputs 2 cable length, shielded, max. 100 m ; twisted and shielded Voltage Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) 100k ohms Analog value creation Integration and conversion time/resolution per channel Resolution with overload area (bit including sign), max. 10 bit Integration time, parameterizable Conversion time (per channel) 625 µs Encoder supply 24 V encoder supply 24 V permissible range: 20.4 to 28.8 V Encoder Connectable encoders 2-wire BEROS Integrated Functions Number of counters 4 Counter frequency (counter) max. 100 khz Frequency meter controlled positioning PID controller Number of alarm inputs 4 Number of pulse outputs 2 Limit frequency (pulse) 100 khz Isolation Galvanic isolation, digital inputs galvanic isolation, digital inputs 500 VAC for 1 minute between the channels, in groups of 1

6ES7212-1AD30-0XB0 Page 6 Isolation, digital outputs Galvanic isolation, digital outputs between the channels between the channels, in groups of 2 Permissible potential difference between different circuits EMC Interference immunity against discharge of static electricity Inteference immunity against discharge of static electricity to IEC 61000-4-2 Interference immunity to cable-borne interference on the supply lines to IEC 61000-4-4 Interference immunity on singnal lines to IEC 61000-4- 4 on the supply lines to IEC 61000-4-5 Interference immunity against high frequency radiation to IEC 61000-4-6 Emission of radio interferences to EN 55 011 (limit class A) Emission of radio interference to EN 55 011 (limit class B) Environmental requirements Operating termperature No 500 VDC between 24 VDC and 5 VDC ; Group 1 min. 0 C max. 55 C vertical installation, min. 0 C vertical installation, max. 45 C horizontal installation, min. 0 C horizontal installation, max. 55 C Storage/transport temperature min. -40 C max. 70 C Air pressure Operation, min. Operation, max. Storage/transport, min. 795 hpa 1080 hpa 660 hpa

6ES7212-1AD30-0XB0 Page 7 Storage/transport, max. Relative humidity Operation, max. Vibrations Vibrations Operation checked according to IEC 60068-2-6 Shock test checked according to IEC 60068-2-27 Degree of protection IP 20 Standards, approvals, certificates CE symbol C-TICK culus FM approval Dimensions and weight Dimensions and weight Width Height Depth Weight Weight, approx. 1080 hpa 95 % ; no condensation 2G panel mount, 1G DIN rail mount ; 15 G, 11 ms pulse, 6 shocks in each of 3 axes 90 mm 100 mm 75 mm 370 g Status Dec 4, 2009