CS-12H D2C4 5 4 A3 ( M as t e r ) CL-12HD2C4 54 A3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a perphase basis while installing equipment into the rack/cabinet. The integral PIPS technology provides accurate measurement of current (billing-grade), voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Smart Master PDU can be connected to a Smart Link PDU to extend the network access to the redundant or secondary power feed. Ke y F e at ur e s N e t wo r k Mo ni t o r i ng Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more. T e mpe r a t ur e /Humi di t y Mo ni t o r i ng Master and Link units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications. A ut o - Fl i p C ur r e nt Di s pl a y Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in highdensity cabinets. "Smart" P e r - Inl e t P o we r S e ns i ng Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy. Br a nc h C i r c ui t P r o t e c t i o n This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses. Hi g h Re t e nt i o n Lo c ki ng Out l e t s Hi g h Re t e nt i o n Lo c ki ng Out l e t s Receptacles have high retention and are compatible with P- Lock type power cords.
I nput s Input Voltage (V): 208 Input Plug: NEMA L6-30P Input Current (A): 30 Input Current Rated (A): 24 Input Power Capacity (kw): 10.0 Out put s Connect or Rat ing (12) x IEC 60320/C19 North American Rating: 16A @208V L-L (20A Peak) Br anch Ci r cui t P r ot e ct i on UL498 Compliant 2-pole, 20A trip circuit breakers, two (2) branch, rating: 16A, 5 kaic Interrupt Rating P hys i cal Dimensions: 3.5in tall x 17.2in wide x 10.0in deep [89mm x 437mm x 254mm] Envi r onme nt al Oper at ing Envir onment : 32 F to 104 F / 0 C to 40 C 8%RH to 90%RH non-condensing 6,500ft/2km elevation S t or age Envir onment : -40 F to 185 F / -40 C to 85 C 8%RH to 90%RH non-condensing 50,000ft/15km elevation Quiescent / Unloaded Power Draw: < 10W for all configurations Communi cat i ons & Se cur i t y 10/100 Mbps Ethernet (RJ-45 connector), RS-232 serial (RJ-45 connector) Two (2) temperature/humidity sensor inputs (4P4C), Link port (RJ-12) - {also on Link PDU} Web-browser GUI and command-line interface (CLI): HTTP/HTTPS, TLSv1.2, SSHv2, Telnet, SNMPv2c and v3 (GET, SET, Traps), IPv4 and IPv6, LDAPv3/LDAPS, TACACS+, RADIUS, FTP/SFTP Ce r t i f i cat i ons Nor t h Amer ican: ctuvus Mark to UL 60950-1:2007 R10.14 CAN/CSA-C22.2 No. 60950-1-07+A1:2011+A2:2014 FCC Part 15 Subpart B Sections 15.107 and 15.109, Class A M e as ur e me nt Accur acy Input Meas ur ement Accur acy: LED Current = ± 10% at 0.1 amp (0.3-9.9 amps) and 1 amp (> 9.9 amps) resolution GUI Current = ± 1% at 0.01 amp resolution (above 0.25 amp) Voltage = ± 1% at 0.1 volt resolution (nominal ± 10%) Active Power = ± 1% at 1 watt resolution Apparent Power = ± 1% at 1 volt-amp resolution Power Factor = ± 3% at 0.01 resolution Crest Factor = ± 10% at 0.1 resolution Energy = ± 1% at 0.1 kilowatt-hour resolution
Opt i onal Acce s s or i e s EMTH-1-1 Combination Temperature/Humidity Probe, 10ft (3m) EMCU-1-1B Environmental Monitor adding: - Two (2) EMTH-1-1 temperature/humidity ports (one probe included) - One (1) EMWS-1-1 water sensor port (probe sold separately) - Four (4) dry contact (NO/NC) monitoring points - One (1) 8-bit analog-to-digital converter (0 to 5VDC) KIT-STEYE-01 or -10 provides access to key metrics through Bluetooth KIT-SUS-01 StartUp Stick for rapid configuration SPM (Sentry Power Manager): - Monitor and manage multiple PDUs from a single point - Monitor and manage alarm conditions - Create reports and trends on stored data - Analyze power usage per phase - Optional appliance or virtual version - Vmware Ready² Mounting Brackets - mounting brackets included - See the Mounting Bracket Guide for further suggestions - Custom mounting options available. Contact your local Server Technology representative Cable Retention Devices for non-locking cords - EZip - Cable Sleeve
Dr awi ng s
Addi t i onal I nf or mat i on Warrantr ant y: Server Technology offers a standard 2-year limited parts & labor warranty. Extended support is available at the time of purchase. See the Support Options on the website, or contact your local Server Technology representative for more information. Pat ent s : Information on Server Technology patents is available on the website at: www.servertech.com/products/patents HDOT, PIPS, POPS, CDU, Sentry, Server Technology, the ST Eye logo, and the globe logo are U.S. registered trademarks of Server Technology, Inc. Power Pivot, EZip, StartUp Stick and PRO2 are trademarks of Server Technology, Inc. Information in this document is current as of time of publishing. Contact your Server Technology representative for the most up-to-date information. 2018 Server Technology, Inc. 1 Cisco EnergyWise is a U.S. registered trademark of Cisco Technology, Inc. 2 VMware and VMware Ready is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. 3 Global models are typically for use in countries outside of North America. Contact your Server Technology representative for more information about which models are appropriate for your application. This datasheet was generated on: 10-Feb-2018