Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Similar documents
REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY

A NOVEL HIGH SPEED, HIGH RESOLUTION, ULTRASOUND IMAGING SYSTEM

APPLICATIONS FOR TELECENTRIC LIGHTING

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

USING A SQUIRTER TO PERFORM PULSE-ECHO ULTRASONIC INSPECTIONS OF GAS TURBINE ENGINE COMPONENTS: THE PROS AND CONS. David A. Stubbs

MICROWAVE THICKNESS MEASUREMENTS OF MAGNETIC COATINGS. D.D. Palmer and V.R. Ditton

Digital Radiography for the Inspection of Small Defects

Characterization of Flip Chip Interconnect Failure Modes Using High Frequency Acoustic Micro Imaging With Correlative Analysis

HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY

SECTION 2. VISUAL INSPECTION

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING

LASER-BASED NDT OF TITANIUM AIRCRAFT ENGINE COMPONENTS J. Doyle Jr and M. J. Brinkman Laser Techniques Company, LLC, Bellevue, USA

Amorphous Selenium Direct Radiography for Industrial Imaging

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

SATECH INC. The Solutions Provider!

Frequency Considerations in Air-Coupled Ultrasonic Inspection.

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE

EVALUATION OF MICROWAVE METHODS FOR THICKNESS MEASUREMENTS OF UQUID SHIM MATERIAL

Digital Radiography : Flat Panel

Module 4 Design for Assembly IIT BOMBAY

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

ON THE WAY TO DIGITAL RADIOGRAPHY

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

RADAR INSPECTION OF CONCRETE, BRICK AND MASONRY STRUCTURES

AUTOMATED EDDY CURRENT DETECTION OF FLAWS IN SHOT-PEENED

Radiographic testing: Increased detection sensitivity using optimum source to object distance

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

ULTRASONIC METHODS FOR DETECTION OF MICRO POROSITY IN COMPOSITE MATERIALS

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Engineering Policy & Procedure

Advanced Digital Radiography for Field NDT

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

redefining the limits of ultrasound

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

DEFECT CHARACTERIZATION IN THICK COMPOSITES BY ULTRASOUND. David K. Hsu and Ali Minachi Center for NDE Iowa State University Ames, IA 50011

v tome x m microfocus CT

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

Quality Assurance Through Nondestructive Screening of Barrel Plating hm'3 Repared 5: Mr. James H. Brim, FeinFocus USA, Inc.

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

tas&m, INC., 107 Research Drive, Hampton, VA 23666

L.D. Favro, H.I. Jin, T.Ahmed, X.Wang, P.K. Kuo and R.L. Thomas

DETECTION OF SUB LAYER FATIGUE CRACKS UNDER AIRFRAME RIVETS

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

ARTICLE 28 VISUAL EXAMINATION STANDARDS

PRACTICAL APPLICATION OF STATE-OF-THE-ART NDE TECHNIQUES: EVALUATION OF GRAPHITE-EPOXY COMPOSITE WING COVERS. Patrick H. Johnston and Doron Kishoni

ACOUSTIC MICROSCOPY INSPECTION OF GLASS REPAIR TECHNIQUES

Examination of Pipe Welds by Image Plate Based Computed Radiography System

Film Replacement in Radiographic Weld Inspection The New ISO Standard

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Hardware for High Energy Applications 30 October 2009

Australian Journal of Basic and Applied Sciences

ELECTRONIC HOLOGRAPHY AND SHEAROGRAPHY NDE FOR INSPECTION

Digital Radiography and X-ray Computed Tomography Slice Inspection of an Aluminum Truss Section

The HOIS recommended practice for in-service computed radiography of pipes

Synchronized electronic shutter system (SESS) for thermal nondestructive evaluation Joseph N. Zalameda

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

Hiding In Plain Sight. How Ultrasonics Can Help You Find the Smallest Bonded Wafer and Device Defects. A Sonix White Paper

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

ULTRASONIC SIGNAL CHARACTERIZATIONS OF FLAT-BOTTOM HOLES IN

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

MIL-STD-883H METHOD ULTRASONIC INSPECTION OF DIE ATTACH

APPLICATION OF ULTRASONIC GUIDED WAVES FOR INVESTIGATION OF COMPOSITE CONSTRUCTIONAL COMPONENTS OF TIDAL POWER PLANTS

CHARACTERIZATION OF FLIP CHIP BUMP FAILURE MODES USING HIGH FREQUENCY ACOUSTIC MICRO IMAGING

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Curved arrays for improved horizontal sizing in small pipe welds

A New Lamb-Wave Based NDT System for Detection and Identification of Defects in Composites

Contrast. Contrast: the difference in density on adjacent areas of a radiograph or other image receptor. Subjective. Long Scale (Low Contrast)

MICROWAVE FIELD MEASUREMENT OF DELAMINATIONS IN CFRP CONCRETE MEMBERS IN A BRIDGE

1. Introduction. 2. Mobile Ultrasonic Inspection System MUSE

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

Using UT to characterize defects in composites detected with Digital Shearography

Computed Radiography

FATIGUE CRACK DETECTION IN METALLIC MEMBERS USING SPECTRAL

AUTOMATED INTERPRETATION OF EXTERNAL TANK WELD RADIOGRAPHS

Migrating from traditional to Digital Radiography in Aerospace

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

Guided Wave Travel Time Tomography for Bends

CHARACTERIZATION OF THE INTERNAL MICROSTRUCTURES OF GRANULAR MATERIALS USING COMPUTERIZED TOMOGRAPHY

Pulsed Thermography and Laser Shearography for Damage Growth Monitoring

RapidScan II Application Note General Composite Scanning

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Nature Protocols: doi: /nprot

Extending Acoustic Microscopy for Comprehensive Failure Analysis Applications

William B. Green, Danika Jensen, and Amy Culver California Institute of Technology Jet Propulsion Laboratory Pasadena, CA 91109

Precision Folding Technology

Principles and Applications of Air-Coupled Ultrasonics. Joe Buckley, Sonatest Plc

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

Fig.2: Scanner VistaScan for image plates

Evaluating Commercial Scanners for Astronomical Images. The underlying technology of the scanners: Pixel sizes:

FAST PHOTOTHERMAL INSPECTION OF PLASMA-SPRAYED COATINGS OF PRIMARY CIRCULATION SEAL RINGS OF A NUCLEAR REACTOR. PART TWO: AFTER THE TRIAL RUN

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

Transcription:

REAL TIME X-RAY MICROFOCUS INSPECTION OF HONEYCOMB E. M. Siwek and J. N. Gray Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010 INTRODUCTION Honeycomb structures are often used because they are light in weight, yet able to bear large pressure loads. Because weight is such a major consideration in the aerospace industry, honeycomb is used in many non-load bearing structures such as control surfaces, access doors, floors, and speed brakes. As may be expected in a complicated structure, there are many possibilities for defects or damage to be induced into these parts, both during the fabrication process and while the part is in service. The presence of these defects necessitate that honeycomb structures be inspected. Film radiography is often used as the primary inspection technique for honeycomb. Alternatively, real time imaging is a filmless radiographic inspection technique which has speed and arbitrary orientation of the sample as its primary advantage. This technique has not been widely used, primarily because of poor image quality. The first point is poor spatial resolution, and the second is poor contrast sensitivity, as compared to film. When a microfocus x-ray source is used in conjunction with a real time system, the result is a marked improvement of the image resolution. The use of image processing can significantly improve the contrast sensitivity. The result is a real time system with resolution equivalent to the present film inspection techniques thus allowing for quicker and less costly inspections, so long a the sensitivity requirements are not too stringent. Benefits Of Microfocus The microfocus technique, developed for the rapid inspection of turbine blades, has been described in the literature(l,2,3) and, as such, we will give only a brief review of the technique. Typical x-ray sources have a focal spot on the target with a diameter of a few millimeters, however, microfocus sources with a focal spot of about 5-10 microns and as such better simulate a point source. An effect directly related to the size of the source is the geometric unsharpness (Ug), or penumbra of the shadow and is given by Ug- ad/d, where a is the focal spot size, d is the object to sample distance, and D is the source to object distance. It should be noted that the Ug factor decreases as the source to object distance decreases. Previous studies (4) have shown that for standard spot sizes, and experimental configuration yielding, a magnification of 2X causes a drop in the contrast of small flaw signals by half. Magnification with a microfocus source with present spot sizes is essentially limited only by the source to detector distance available and the limits of sufficient flux. Review of Progress in Quantitative Nondestructive Evaluation, Vol. 9 Edited by D.O. Thompson and D.E. Chimenti Plenum Press, New York, 1990 1549

The usefulness of inspections using both radiographic film and real time imaging was studied with particular attention on the effects of the magnification and image processing capabilities of the microfocus real time system. Several samples were tested, which were different combinations of aluminum or Nomex honeycomb with either aluminum or graphite/epoxy composite face sheets. There were a variety of flaws in these samples, ranging from fabricated inclusions to impact and fatigue damage. The samples also ranged in thickness from 1 to 4 inches. Of the many possible types of damage, the following conditions were observed in this study: crushed core, condensed core, cut core, foreign material damage, blown core, adhesive porosity. Crushed core is localized buckling of the cell walls, and may result from impact damage. Condensed core pertains to rows of core which are pushed together and are not their full size. Cut core and foreign object damage may occur during the manufacturing process as a result of handling. Blown core usually results from heating trapped volatiles, which expand the cell walls. Bondline porosity is sometimes created during fabrication, and can cause delamination of the face sheet if too much exists. Incomplete core splices may also exist, which is characterized by lack of bonding filler between the core sections. Many other conditions not observed in this study may exist, such as distorted core, missing core, cracks, and crazings. Magnification To quantify the benefits of the microfocus source of the system, the samples were inspected at different levels of magnification, using both film and real time imaging for detection. Intensity of the source was varied using the different voltage and current settings to present the best contrast for each image. Samples were set on an automated rotation stage and x-y positioner. As expected, without magnification, it was much easier to see flaws in the film because of the high spatial resolution. Magnifications for X-1,2,3 were recorded, and higher magnifications observed. For the film, lx generally gives a good enough picture to distinguish major flaws in a sample, but it takes a trained eye to see damage such as core crush. Core crush is difficult to determine because of its subtle doubling effect of the cell walls. It would be easier to distinguish this type of flaw if the contrast between cell and cell wall were clearer, something easily done with magnification. At 3X and higher magnification, core crush becomes even more distinguished making inspection easier, more reliable, and faster (figures la and lb). The use of magnification for the real time inspection of honeycomb is critical. It is very difficult to distinguish damage without magnification. As magnification increases, the detectability of damage in the sections also increases. Our observations show that most damage can be distinguished with the present imaging system at approximately 3X. Thickness And Orientation Effects in Real Time Inspections Intuitively, one would think that magnification of a radiographic image would help show the flaws in all cases; however, this is not true in the case of very thick samples. Because there is a difference in the distances of the front and rear of the sample with respect to the source, one side of the part is magnified more than the other. This, in conjunction with the effect of the radial divergence of the beam, produces a very distorted picture, with only a small portion of the radiograph acceptable for interpretation. Although this distortion is apparent in this particular case, a system with a larger source to detector distance would not have as great of an effect. Indeed, in industrial inspections large source to film distances are used to minimize the effects of the radial divergence of the beam. However, the positioning of parts with respect to film is very tedious with thick 1550

(la) (lb) Fig. 1. Real time x-ray image of aluminum core, a luminum skin honeycomb with impact damage indicated by narrow dark l ead marker. Note the cell layover due to the close source to sample distance and the lack of any indication of cell wall crushing in la. The damage is easily seen in lb. This image is a 3x magnification with the crushe d walls showing up as a split line. Bubbles in the skin - honeycomb adhesive are easily seen in lb. 1551

honeycomb parts. Lining up the part so that the beam is going through the cell is difficult, because the slightest angle on a thick part will cause a lay over effect, resulting in a hopelessly complicated image. This use of large distances to minimize the effect of cell layover has a consequence of making the cells very small, thus making the inspection more difficult. This overlap difficulty is avoided with a real time system, in that parts can easily be positioned in a mode that maintains the large size of the cells before capturing an image. The part can be scanned in its entirety with far greater ease and speed than the corresponding film inspection. A further example of a difficulty due to orientation problems is that of detecting crack-like flaws. The angular orientation requirements of any inspections needed to locate node separation or cracks make them easily missed. Samples can not be moved at all during a film exposure, and would need to be reoriented several times before the proper angle was found to locate a crack or orient for thickness, an expensive procedure to say the least. With real time imaging and it continuous rotation capability, the likelihood of finding this type of flaw greatly enhanced. The orientation dependence of flaws, and cracks in particular, is not the only factor in their detection. As mentioned earlier, the second major influence is the contrast sensitivity. The greater the contrast sensitivity of the inspection system, the more reliable the flaw detection. It is in this area that image enhancement of the real time images yields an increase in the contrast. Figure of Merit for Image Processing Real time image enhancement can be a very beneficial tool, when used correctly. Unfortunately, image processing is not always the cure for a difficult to interpret image. As in the case of the honeycomb inspection, some of the filters and routines actually produced deceiving results. Sections of the image which were darkened due to effects of the set-up, were emphasized instead of the desired damaged portion. This is an example of an artifact introduced by the enhancement routine and is one element that makes the effectiveness of an image enhancement procedure is difficult to assess. The second area that is difficult to measure visually is the amount of improvement for equal quantities of computer processing time. This is a critical issue in that the real time image processing must be done in real time. We developed a method to evaluate the effectiveness of image processing routines both for the introduction of artifacts and the value of the enhancement. To do this we make use of a simulation of the image formation process(4,5,6). There are several important features of this approach including the fact that the process noise is modeled and as such it can be turned on or off at will. Secondly, the exact knowledge of the flaw shape and size is known. The procedure is to turn off the noise and run the simulation. This gives an ideal image which would be obtained if one had ideal detectors and no process noise. An image with identical setup parameters is generated with the process noise on. A comparison to the ideal image gives a quantitative measure of the loss in contrast and the reduction of the geometric extent of the size of the flaw. This represents the maximum amount that good image processing could recover. We now have a standard to compare the effectiveness of image processing routines. Figures 2a,2b,2c, and 2d illustrates the result on a simple part, namely a flat plate with a conical shaped void. It should be pointed out that the simulation is not limited to simple shapes, but is able to handle most any part and flaw shape. The normal process noise can cause a factor of two under sizing of the flaw, especially if the thickness of the flaw is close to the sensitivity limit of the system. Some of the most effective real time processing routines proved to be the simplest. 1552

(2a) (2b)... : ~. r. Fig. 2. (2c) (2d) Figure 2a is the simulated image of a conical axial in a flat plate with no process noise and figure 2b represents the same flaw with the normal noise processes. Figures 2c and 2d represent the result of simple image processing, specifically background subtraction and grey level stretching. Note that the sizing of the processed image (2d) compared to the perfect image (2a) are very close. 1553

Figure 2a 2b 2c 2d Image Image with no noise Image with noise Processed image with background substracted Processed image with additional constant substracted *Artifact for quantitative sizing Table I. Spatial Extent 100% 67% 77% 99% Contrast 100% 84% 131%* 220%* 1.0 0.9..., 0 0.7 2,_0.6 ~ 0. 5 - ~ 0.4...,..., i3 0.3 Q) ~ ' = 0.2 <..._..._ Image Intensifier without processing ~ f } f limage e l " ' Intensifier with processing Geeeo Film 0.1 0.0 ~ o n ~ r n ~ r n ~ r n o r r n o r r n o r r n o r r n o r r n o r 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 Percenl Thickness Sensilivily Fig. 3. The detectability of the same flaw based on experimental measurements using film and an image intensifier with and without image processing. The thickness sensitivity of the image intensifier without processing falls off rapidly at about 4% as compared to improcessed fiber and processed real time images which fall off at 2%. A simple background subtraction and subsequent grey scale stretch yields an impressive improvement of flaw sizing. The artifact that is easily apparent is the huge increase over the actual contrast. This would, if used, result in an over sizing of the thickness of the flaw. For quantitative measure, see Table I. Figure 3 shows the summary of the results of image enhancement comparing an image intensifier with and without real time image enhancement to film. As can be seen the thickness sensitivity of the real time system with image enhancement compares with those obtained from unprocessed film. Of course, when a film radiograph is digitized and processed, the results will be better than those of an image intensifier. CONCLUSIONS As noted, there are some drawbacks of real time inspection systems, the first being spatial resolution, the second being poor thickness 1554

sensitivity. The solution of the problem of poor resolution is to use geometric magnification. Magnification with the microfocus system is relatively easy to do, and increases resolution by approximately the magnification factor. This increases the ability to interpret the image, and locate flaws, thus compensating for the initial poor spatial resolution. The solution to the lack of thickness sensitivity is the proper application of real time image enhancement. Unlike the improvements in resolution, improvements that are readily seen with a resolution gage, the improvements of a particular image enhancement routine remain unclear. The development of a quantitative figure of merit to measure the improvement in the spatial sizing, the detectability of the indication, and the artifacts introduced give a way to evaluate the best image enhancement procedure. The evaluation of the optimum procedures is particularly important in real time inspection where the enhancement must be effective to recover lost sensitivity without loosing the flexibility of the real time inspection. The use of the magnification capabilities of a microfocus x-ray source in conjunction with a real time imaging system provides an effective way to inspect honeycomb structures. The most obvious asset is the speed at which an image can be produced, which is quite a bit faster than the time necessary to process film. Another advantage is that the orientation of the object can be adjusted using positioners in real time while viewing the image. Also, the digital image created allows for immediate image processing, which may or may not help the image. ACKNOWLEDGEMEN'l' This work was sponsored by the Center for Nondestructive Evaluation at Iowa State University and was performed at the Ames Laboratory. Ames Laboratory is operated for the U.S. Department of Energy by Iowa State University under Contract No. W-7405-ENG-82. REFERENCES 1. R.W. Parish and D.A.J.Cason, NDT International, 1Q,#4,pl81-5 (1977) 2. R.W.Parish 'Microfocus X-Ray Technology- A review of Development and Application', Review of Progress in Quantitative Nondestructive Evaluation, vol. SA, ed. by D.O.Thompson and D.E. Chimenti, Plenum Publishing Co.,(l988) p.l-20 3. Halmshaw, R., Non-destructive Testing, Edward Arnold, Great Britain, 1987. 4. J.N. Gray, 'Three Dimensional Modeling of Projection Radiography', Review of Progress in Quantitative Nondestructive Evaluation, vol. 7A, ed. by D.O.Thompson and D.E. Chimenti, Plenum Publishing Co.,(l988) p.343-348 5. J.N. Gray, F.Inanc, and B.. E.Shull 'Three Dimensional Modeling of Projection Radiography', Review of Progress in Quantitative Nondestructive Evaluation, vol. 8A, ed. by D.O.Thompson and D.E. Chimenti, Plenum Publishing (1989) 6. F.Inanc and J.N. Gray 'Three Dimensional Modeling of Projection Radiography', Review of Progress in Quantitative Nondestructive Evaluation, vol. BA, ed. by D.O.Thompson and D.E. Chimenti, Plenum Publishing (1989) 1555