SafeLine VA4. Operating instructions

Similar documents
CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1

alternating relays catalog a of products com

OHIO SEMITRONICS, INC. DIGITAL AC POWER MONITOR OSI SPECIFICATIONS

TA-Slider 160. Actuators Digitally confi gurable proportional push actuator 160/200 N

System Power Amplifier (SPA)

A Super trainer with advanced hardware and software features only found in very expensive equipment.

Spectrum & Power Measurements Using the E6474A Wireless Network Optimization Platform Application Note By Richard Komar

E A M P R O F I B U S

SINEAX TV809, 1 channel Programmable Isolating Amplifier

TECHNICAL NOTES MT-4 Radio Systems TN182 Battery Level Reporting and Remote P25 Test Tone

Signet 2610 Process Optical Dissolved Oxygen Sensor

* * Signet 2610 Process Optical Dissolved Oxygen Sensor. Operator's Manual. Introduction. English. System Description.

MULTIFUNCTION GRAPHICAL UNIT MGU 800

Appendix G: IFR 8800 Test Procedures MAINTENANCE GUIDE.

MODEL: M2EXT. Super-mini Signal Conditioners with Display Mini-M M2E Series

Traffic Lights/ Signal Beacons - 890/895/897/894/ families

EBI7904CAx-DA-IF Incremental FixPitch Sensor Module

OEM PRODUCTS WIRELESS WORLD LOCAL SOLUTION

USER MANUAL SATEL i-link I/O-converter Version 1.6

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

VX-3000 Series Voice Alarm and Public Address System

> Product category: > Function: > User profi le: > Frequency band: 100 KHz to 6 GHz. > Related standard: ECC/REC/(02)04, EN > Related software:

DataSheet. Tinytag Radio System

ILLUSIONS MOBILE CASE GOODS

MODEL: M1EXT. with Display M1E Series

HD 48V01T... HD 4977T...

Digital Room Sensor Technical Guide

SINEAX V604s Programmable multifunctional transmitter

Series HD 2A, 60Vdc, True Output Status Feedback, Short-Circuit Protected DC Solid-State Relay

Universal dimmer 6.3.1

Modicon Momentum automation platform 0

Wire Mesh Cable Tray System for Channeling of Cable Wiring

KINAX WT 717 Programmable Transmitter for Angular Position

QUAD NON-PROGRAMMABLE PCM CODEC

Agilent ESA-E Series Spectrum Analyzer

Solutions ADVANCED SOLUTIONS FOR SMART COMMUNICATIONS. RADIO DISPATCHER FLEET PHONE APP BRIDGE

ROBERTS RD-25. Sound for Generations. MW/FM RDS/DAB Digital Portable Radio. Please read this manual before use

DSTS-5A/2C User's Manual

IX Series 2. Description. IX Series 2 System Features

XYZscan User Manual ENG. XYZscan User Manual P 1

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

EBI7903CAx-DA-IF Incremental Sensor Module

Advanced Test Equipment Rentals ATEC (2832) Contents

... yet still led out of the terminal quickly and safely in an emergency.

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Compact Signal Calibrator

TECHNICAL NOTES Technical Notes for Tuning, Installing, Maintaining and Servicing MT-3 and MT-4 Radio Systems

ALPTEC POWER FACTOR CONTROLLER

Table of Contents 1 ESD PRECAUTIONS WEAVEFUTURE INTERNET CAFÉ KIOSK BOARD...3

EASIVOICE SYSTEM SECTION 2 (REV.A) Download from: Technical Manuals area BASIC DIAGRAMS EASIVOICE SYSTEM EASIVOICE. sec.

ROBERTS WM-202. Sound for Generations. with Enhanced User Interface. DAB+/FM WiFi Internet Radio with MP3/WMA Media Streaming

Functions module / Gateways Application Description Product Page KNX-GW-DMX-xxx DMX Gateway. KNX-GW-DMX Product Group 1

C-Bus DSI Gateway. 5508DSIP Series. Installation Instructions

PIM USER GUIDE

MAGNETIC-LATCHING DC-8 GHz TO-5 RELAYS 4PST

Operating Instructions

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

MIT ATHLETICS. LOGO STANDARD GUIDELINES

KINAX 2W2 Programmable Transmitter for Angular Position

Guardian and DL3282 Modem Interface Technical Service Application Note

A balance between cost and benefits without compromising maximum quality. Ideal, both for industry and commercial buildings.

TIY Programmable, Isolated Thermocouple Transmitter combines

My Nextel. User Guide

ANI-F. Multi-Format ANI Encoder. Manual Revision: Covers Software Revisions: ANI-F: 1.2 and higher

TRBOnet Mobile. User Guide. for ios. Version 1.8. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

Digital Multifunctional RC-Soundmodule TBS Mini V2

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

TRBOnet Mobile. User Guide. for Android. Version 2.0. Internet. US Office Neocom Software Jog Road, Suite 202 Delray Beach, FL 33446, USA

INSTRUCTION MANUAL. Version: /440 MHz FM DUAL BANDER TM-D710GA. 144/430 MHz FM DUAL BANDER TM-D710GE

INSTRUCTION MANUAL. Version: /440 MHz FM DUAL BANDER TM-D710GA. 144/430 MHz FM DUAL BANDER TM-D710GE

VENUE Full Isolation D.I.

TEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.

802.16s SOFTWARE PLATFORM

INSTRUCTION MANUAL. Octave 1/3 Octave Real-time Analysis Program NX-42RT

THZ DH & WL. Features. Smart HART and WirelessHART Temperature Solutions

INSTRUCTION MANUAL. Octave 1/3 Octave Real-time Analysis Program NX-42RT

Ness M1RF Wireless Receiver

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

ENG. XYZscan User Manual P 1

REHAU PROFILA BENCH TRUNKING A CABLE MANAGEMENT SYSTEM WITH MULTIPLE ALTERNATIVES. Construction Automotive Industry

PKT-23 INSTRUCTION MANUAL UHF FM TRANSCEIVER B5A (E, T)

BTD-2. BTD-2 MOD-1272 Addendum

Challenging Communication Boundaries. 950 Radio. Management System Series II

Indica 2.4 GHz Chip Antenna Part No. A10381 giganova Product Specification

Installation Guide Multi Position Servo Controller E1100-MP and E1100-MP-HC

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

DVDO Air3C-PRO TM Quick-Reference Guide. Version 1.0

1 ImageBrowser Software User Guide 5.1

Personal & Area Monitors

Series CD. 2A, 60Vdc Optically Isolated, Short-Circuit Protected DC Solid-State Relay ELECTRICAL SPECIFICATIONS

MBC10P31 Series. Programmable Pulse Generator. User s Guide. 910 East Orangefair Lane, Anaheim, CA

T 1000 PLUS Secondary Injection Relay Test Set

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

Welcome. Manual version V (for FW 4.45 and higher) RUKRA Europe B.V. Koperslager SJ NIJKERK The Netherlands

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

POWER CLAMP-ON METER ENGLISH. User Manual

Programmable Active Crystal Filters Catalog

Transcription:

SafeLine VA4 Operating instructions

SafeLine VA4 Operating instructions safeline.eu

Table of contents Safety and general information Introduction 4 Installation & Testing Configuration 5 Configure with SafeLine Pro 6 Measurements 7 Connections 7

SPEAKER PROG Safety and general information INTRODUCTION 1 2 9 3 4 POWER STATUS ACTIVE 24VDC 8 7 6 5 1. Rs232 PC connection For fi rmware update and programming. 2. Terminal for speaker Recommended: Broad band speaker 4-16 Ohm, min 0.5 W. 3. Volume Increase or decrease volume of the speaker. 4. Terminal for power supply Connect 20-30 VDC power supply to the terminal. 6. Rec LED Red LED, fl ashes during communication with a PC. 7. Status LED Yellow LED, fl ashes when a message/music is played. 8. Power LED Green LED, fl ashes when the unit is powered. 9. Terminal for inputs and trigg signal. 5. Jumper for active 0 inputs. Place the link on the jumper for active 0 inputs. 2010 SafeLine and all the SafeLine products and accessories are copyrighted by law. 4

CONFIGURATION VA4 can be programmed in SafeLine Pro Version 2.23 or later (V3.30 recommended). Reconfi guration and changes to previously recorded messages can easily be made. SafeLine Pro can be downloaded for free on our web site: www.safeline.eu. Downloading new voice messages: If the prerecorded messages need to be changed or if new messages have to be added we can send the fi les to you by e-mail and you can easily download them in VA4. When recording and downloading own sounds. A sound fi le name can be no longer than 59 characters. The sound have to be in wav-format, mono with 16-bits resolution and 8 or 16 khz sample frequency PCM. VA4 is normally delivered with 2048 KB Flash-memory this is enough for 240 sec of recording at 8 khz or 120 sec in 16 khz. Both 8 and 16 khz sampled *.wav-fi les can be downloaded in the same VA4. If you have recordings in any other resolutions or format they have to be converted fi rst. Inputs: Standard confi guration at delivery is: Input 1-4, are Binary inputs 1,2,4,8. Input 5-8 are fi xed messages that are used for all fl oors like Doors are closing, Lift is overloaded, Fire alarm etc. Configuration: The inputs can be confi gured with SafeLine Pro: Binary / Decimal / Gray code inputs for maximum 1-32 fl oors. Fixed messages 1-8 can be selected. Trigg signal: Floor message can be played when a trig input is activated, or when one of the inputs status are changed. All changes and downloading of new messages have to be made from SafeLine Pro. Polarity and voltage: The input voltage can be between +20-30 VDC. If Active 0 input is activated a 0 VDC signal activates the input. Supply voltage must be 20-30 VDC. 5 2010 SafeLine and all the SafeLine products and accessories are copyrighted by law.

Installation & testing CONFIGURE WITH SAFELINE PRO Nr (floor nr): Double click to get the *.wav-fi le for each fl oor (1-32). Floor messages: Shows *.wav-fi le for selected fl oor. Double click to select your fi les. Time: Displays duration in seconds on each *.wav fi le. Memory usage: Displays remaining memory. Input type: Choose how the inputs should be confi gured. Input type can be Binary, Gray code or Decimal. Number of floors: Choose how many fl oors to be used. Inputs on card: Select input format and confi gure how to use the input signals. Input format can be Binary, Gray code, or Decimal. Input 9 is always used as trigg Trigg on change / trigg on signal: Choose how to start playing the sound messages. Fixed messages: Shows *.wavfi les for fi xed messages. If trigg on change is selected, VA4 will play the fl oor message when the input status is changed. Play selected sound: Play all stored sounds: Read config: Erase and Write: Read Sounds: Clear Config: Open File: Save To File: Show Product: Play selected *.wav-fi le. Play all *.wav-fi les. Read confi guration from a programmed VA4 (sound headers+confi g). Write changes to VA4. Reads the *.wav-fi les that is programmed in the VA4. Erase all fi elds, and changes all settings to default. Open a saved *.VA3. Saves all parameters and sounds in a fi le with the extension *.VA3. Show a picture of VA4. 2010 SafeLine and all the SafeLine products and accessories are copyrighted by law. 6

SPEAKER PROG MEASUREMENTS VOLUME 50 mm POWER STATUS ACTIVE 72 mm 24VDC CONNECTIONS Trigg signal Input 8 Input 7 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Input 1-8: Connections from controller. Trigg: Connection from trigg signal. Positive/Negative input signals: The VA4 can be set for either positive or negative input signals. It is set for positive signals as default. To chose negative input signals, mount the jumper over ACTIVE 0 INPUT. Active 0 input 24VDC Power supply 20-30 VDC Broad band speaker 4-16 Ohm, min 0,5 W. 7 2010 SafeLine and all the SafeLine products and accessories are copyrighted by law.

safeline.eu SafeLine is a registered trademark developed by: SAFELINE EUROPE Blvd de la Woluwelaan 42, 1200 Brussel BELGIUM Phone: +32 (0)2 762 98 10 Fax: +32 (0)2 762 97 10 E-mail: info@safeline.eu Support: www.safeline.eu/support