RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

Similar documents
User s Guide. RP7000 Series Active Probe. Dec RIGOL Technologies, Inc.

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

2015 RIGOL TECHNOLOGIES, INC.

RIGOL Service Guide. DS4000 Series Digital Oscilloscope. Mar RIGOL Technologies, Inc.

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP016 Passive Probe

RIGOL. Quick Guide. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Jul RIGOL Technologies, Inc.

Agilent 1160 Series Miniature Passive Oscilloscope Probes. User s Guide

RIGOL. Quick Guide. DG2000 Series Function/Arbitrary Waveform Generator. Sept RIGOL Technologies, Inc.

DS1000E, DS1000D Series Digital Oscilloscope

TA MHz oscilloscope probe TA MHz oscilloscope probe

Operator s Manual. PP017 and PP018 Passive Probes

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

DS1000B Series Digital Oscilloscope

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

PHV RO High Voltage Passive Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

TT-SI MHz Active Differential Probe

TETRIS User's Guide. High Impedance Active Probe DO177-1

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

400 MHz Passive High-Voltage Probe R&S RT-ZH

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

N2790A Differential Voltage Probe

TT-SI MHz Active Differential Probe

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

PKT 512A-RO High Impedance Passive Cable Divider

RP1003C/RP1004C/RP1005C

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 2nd Edition IM E

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Keysight N2790A Differential Voltage Probe. User Guide

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Tablet Oscilloscope Safety Information

Instruction Manual Model Upconverter

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

TT-SI MHz DIFFERENTIAL PROBE

TT-SI 9001 / TT-SI MHz Active Differential Probes

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

MD 200A High voltage differential probe

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

312, 316, 318. Clamp Meter. Users Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Table of Contents. 1. General Safety Requirements Safety Terms and Symbols Quick Start... 4

AMP-13 OPERATOR S MANUAL

Instruction Manual Model Upconverter

NOTE: Fully read and understand this manual before using this Digital Multimeter.

RIGOL. Quick Guide. DS4000 Series Digital Oscilloscope. Sept RIGOL Technologies, Inc.

Model /701913/ PBA1000/2500/1500 Active Probe

200Amp AC Clamp Meter + NCV Model MA250

USER'S MANUAL DMR-6700

T5-600/T Electrical Tester

User s Guide RIGOL. PA1000 Series Power Amplifier. Publication number: UGF Mar RIGOL TECHNOLOGIES, INC. All Rights Reserved.

Dawson DDM190. Digital Multimeter User s Manual

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

1157A 2.5 GHz Active Probe

1156A 1.5 GHz Active Probe

DM-45 Digital Multimeter

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Keysight N2771B 30 kv High Voltage Probe

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

Instruction Manual CT-6 High Frequency AC Current Probe

AMM-1022 Digital Multimeter USER`S MANUAL

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

E5382B Single-ended Flying Lead Probe Set (for analyzers with 90-pin pod connectors) User Guide

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Model UT511 OPERATING MANUAL

RIGOL. User s Guide. DSA1000&DSA1000A Series Options&Accessories. Feb RIGOL Technologies, Inc.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

User s Manual. Model PBD2000 Differential Probe. IM E 1st Edition. Yokogawa Electric Corporation

KMD-S04 Multímetro de bolsillo

80i-110s AC/DC CURRENT PROBE

Model 9305 Fast Preamplifier Operating and Service Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

CIRCUIT-TEST ELECTRONICS

CLEANING CALIBRATION INTERVAL

DMM8900 SERIES USERS MANUAL

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

AMP-12 OPERATOR S MANUAL

Autoranging Multimeter Extech EX503

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

AC/DC CLAMP METER USER S MANUAL

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

BENNING. CM7 Electrical Tester. Service Information

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

80i-110s. AC/DC Current Probe Instructions. Introduction

USER'S MANUAL DMR-4350

600A Clamp Meters w/tightsight Display

Multifunction Digital

5MHz FUNCTION GENERATOR

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

5MHz FUNCTION GENERATOR

Transcription:

User s Guide RP5600 Passive Probe July 2010 RIGOL Technologies, Inc.

Guaranty and Declaration Copyright 2010 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL is a registered trademark of RIGOL Technologies, Inc. Notices RIGOL products are protected by patent law in and outside of P.R.C. RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision. Information in this publication replaces all previously corresponding material. RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing, use or performance of this manual as well as any information contained. Any part of this document is forbidden to copy or photocopy or rearrange without prior written approval of RIGOL. Product Certification RIGOL guarantees this product conforms to the national and industrial standards in China. International standard conformance certification is in progress, e.g. ISO. Contact Us If you have any problem or requirement when using our products, please contact RIGOL or your local distributors, or visit: www.rigol.com I

General Inspection When you get a new RP5600 probe, you are suggested to take the following steps to inspect the probe. 1. Inspect the shipping container for damage. If there are damages in the container or foam, keep them until the whole machine and the accessories passing the electrical and mechanical tests. If your probe has damaged during shipping, please contact your carrier and RIGOL sales office responsible for this business. 2. Inspect the probe. In case of any mechanical damage or defect, or if the probe does not operate properly or pass performance tests, notify your RIGOL Sales Representative. 3. Check the accessories. Accessories supplied with the probe are listed in the Accessories" section. If the contents are incomplete or damaged, please contact the local sales representative of RIGOL. II

Safety Terms and Symbols Terms in This Guide. These terms may appear in this manual:! WARNING: Indicate the conditions or practices that could result in injury or loss of life.! CAUTION: Indicate the conditions or practices that could result in damage to this product or other property. Terms on the Product. These terms may appear on the product: DANGER indicates an injury or hazard may immediately happen. WARNING indicates an injury or hazard may not immediately happen. CAUTION indicates that a damage to the instrument or other property might occur. Symbols on the Product. These symbols may appear on the product: Hazardous Voltage! Refer to Instructions Protective Earth Terminal Chassis Ground Test Ground III

Contents Guaranty and Declaration... I General Inspection... II Safety Terms and Symbols... III Contents... IV RP5600 Probe at a Glance... 1 Accessories... 2 To Connect to the Oscilloscope... 5 To Use the Probe... 7 Compensation Adjustments... 10 Characteristics... 12 General Care and Cleaning... 13 Warranty... 14 IV

RP5600 Probe at a Glance The RP5600 passive probe of RIGOL with the bandwidth up to 600MHz, uses modular structure allowing to replace the probe tips. The probe has compact structure and uses snap-on BNC connector which can be easily connected to the oscilloscope. Features: Analog bandwidth up to 600MHz. Precise and tenuous probe tip. Auto identification of the probe attenuation ratio (need to be supported by the oscilloscope). Firm, durable and retractable normal probe hook. Equipped with many kinds of ground lines to connect to different earth terminals. 1

Accessories The figure and table below list the standard accessories and options of RP5600. All the accessories can be ordered and purchased from RIGOL. 8 14 5 6 4 3 7 2 9 12 13 10 1 11! CAUTION: The measurement category of the combination of the probe and the accessories (used to assist the measurement) is the lower one in the combination. 2

Standard Accessories Item# Name Number Qty 1 Probe RP5600-0200101 1 2 Probe tip RP5600-0200201 2 3 Barrel Insulator (long) RP5600-0200301 1 4 Barrel Insulator (short) RP5600-0200401 1 5 General purpose retractable hook tip RP5600-0200501 1 6 Dual-lead adapter RP5600-0200601 1 7 Probe bracket RP5600-0200701 1 8 SMD clip RP5600-0200801 2 9 Spring clip RP5600-0200901 2 10 Alligator ground lead RP5600-0201001 1 11 Socketed ground lead RP5600-0201101 1 12 Screwdriver RP5600-0201201 1 13 Sign loop RP5600-0201301 8 14 BNC adapter RP5600-0201401 1 1 Probe Main body of the probe 2 Probe Tip Front Component of the probe 3,4 Barrel Insulator (long, short) When using the short one, the ground terminal is exposed in favor of using the spring clip. While using the long one, the ground terminal will be covered completely to avoid short circuit between the probe and the circuit under test. 5 General Purpose Retractable Hook Tip It is retractable. 3

6 Dual-lead Adapter Lead out a plug from the signal terminal and the ground terminal of the probe respectively. 7 Probe Bracket To lay and fix the probe during the measurement. 8 SMD Clip Lead out the pin signal of the circuit under test. 9 Spring clip Connect to the probe tip for grounding and can improve the high-frequency response. 10 Alligator Ground Lead Ground the probe reliably for safety operation and accurate signal reading. 11 Socketed Ground Lead The same usage as the alligator ground lead but use different joint (see in the figure of the standard accessory) 12 Screwdriver Be used in probe compensation adjustment. 13 Sign Loop Fix the sign loop on the probe to distinguish the probes connected to different channels. 14 BNC Adapter Use this adapter to connect the probe to a BNC terminal. Options (used in high-frequency compensation adjustment) Item# Name Number 1 50Ω feedthrough RP5600-0300101 4

To Connect to the Oscilloscope 1 Connect the probe to the channel or the external trigger input of the oscilloscope. Push it straight on until it latches firmly. 2 Connect the probe to the circuit under test. 5

3 To disconnect the probe from the oscilloscope, push the small buttons on the top and bottom of the probe connector, and then pull the connector out from the front panel of the oscilloscope.! CAUTION: Do not attempt to twist the probes on the oscilloscope's BNC connector, which might cause damage to the probe. 6

To Use the Probe! CAUTION: If users do not follow the instructions in the Guide when using the probe, the protection provided by the probe might decline or disappear.! CAUTION: Do not solder the probe tip to any surface, Or else the probe tip would be damaged.! CAUTION: If using the probe without any accessories, the probe might cause short circuit when connected to the circuit. To connect the probe to the circuit under test When using the probe to measure some hard-to-reach positions, you can spare the probe accessories. 2 1 RP5600 has two kinds of barrel insulators: long and short. The figure above uses the long one which can rotate in the direction of arrow 1 and can be taken off in the direction of arrow 2. 7

The barrel insulator can be rotated to various positions: Screw down the barrel insulator and add the spring ground to the probe tip for grounding. Unscrew the barrel insulator to cover the probe front and insulate the ground. Barrel insulator with ground accessories Ground the probe by connecting either the alligator ground, the Socketed ground lead or the spring ground which all provides a ground point. It is necessary to use the barrel insulator in conjunction with any of the ground accessories so as to avoid possible short circuit. Barrel insulator (short) with general purpose retractable hook tip Connect the ground lead to the probe and connect the hook tip buy pressing the probe hook tip towards the probe. Then, press the hook tip to expose the front conductor and connect it to the testing point. Probe bracket The probe bracket can facilitate your circuit testing. Users can place the probe on the bracket to spare their hands. As shown in the figures below, choose the proper holes to insert the probe into the bracket and connect it to the testing point, then place the whole equipment to a proper position. 8

Usage Method Placement Method WARNING: RP5600 and the oscilloscope use the same terminal ground (complies to OSHA condition) and the exposed metal surface of the probe and the oscilloscope must be grounded. In particular application using floating ground measurement, the operator has the potential danger of electric shock which could be fatal (depends on the voltage and current conditions). 9

Compensation Adjustments You are suggested to compensate the probe so as to match its characteristics with the oscilloscope. The probes can be adjusted for both low-frequency compensation and high-frequency compensation. You should make low-frequency compensation of the probe when it is connected to the oscilloscope for the first time (or adjust it at any time) while high-frequency compensation can be adjusted regularly. Low-frequency compensation Follow the steps below to make low-frequency compensation: 1 Connect the probe to the probe adjustment signal terminal at the front-panel of the oscilloscope to make compensation adjustment via the low-frequency compensation adjustment hole. 2 Press Auto at the front panel of the oscilloscope. 3 Set the low-frequency compensation adjustment on the probe using the metal plate or cross of the Screwdriver provided to get the smoothest pulse (as shown in figures below). Over compensated Low-frequency Compensation Adjustment Perfectly compensated Under compensated 10

High-frequency compensation Low-frequency compensation must be performed before executing High-frequency compensation. Follow the steps below to make high-frequency compensation: 1 Connect the 50Ω feedthrough (option) to a generator with quick edge signal. 2 Connect the BNC adapter to the 50Ω feedthrough. 3 Remove the accessories (the spring or the hook tip) at the probe front and the barrel insulator. 4 Connect the probe tip to the BNC adapter and connect the probe to the oscilloscope. 5 Output a quick edge signal less than 500 ps from the generator. 6 Press Auto at the front panel of the oscilloscope to view the waveform. 7 Use the mental plate or cross on the Screwdriver to rotate the resistance R1 and R2 of the high-frequency compensation. 8 Adjust R1 and R2 alternately in tiny increments until the waveform displays flat tops and steep rising edges. R1 R2 High-frequency Compensation Adjustment 11

Characteristics Performance Specification Bandwidth DC ~ 600MHz Attenuation Ratio 10:1 Input Impedance 10MΩ±2% Input Capacitance 12pF± 1pF Maximum Input CAT II 300VAC Compensation 6pF ~ 26pF Range General Specification Operation Temperature: 0 C ~ 50 C Environment Humidity: 0 RH ~ 80%RH Storage Temperature: -20 C ~ 60 C Environment Humidity: 0 RH ~ 90%RH Size 142± 2cm Weight Approximately 48± 2g This symbol indicates that the RP5600 probe is in compliance with European product regulations which include the EMC Directive and the Low Voltage Directive. Installation (overvoltage) Category The terminal of this product may have two Installation (overvoltage) categories: Measurement Category II (CAT II). CAT II is for measurements performed on circuits directly connected to low-voltage installation (AC Line). Measurement Category I (CAT I). CAT I is for measurements performed on circuits not directly connected to AC Line. 12

General Care and Cleaning General Care Do not store or leave the probe in places where it will be exposed to direct sunlight for long period of time.! CAUTION: To avoid damage to the probe, do not expose it to sprays, liquids, or solvents. Cleaning Clean the probe regularly according to the operation situation. Disconnect all the powers before cleaning the probe. 1. Wipe the floating dust on the exterior of the probe with a soft cloth or a wet soft cloth with neutral detergent. Make sure that the probe is completely dry before connecting it to power. 2. To avoid damage to the probe, do not use any corrosive chemical detergent.! WARNING: To avoid any short-circuit or personal injuries caused by moisture, make sure that the probe is completely dry before connecting it to power. 13

Warranty RIGOL Technologies, Inc. warrants that its products mainframe and accessories will be free from defects in materials and workmanship within the warranty period. Within the warranty period, RIGOL guarantees free replacement or repair of products which are proven defective. For detailed warranty description, please refer to RIGOL official website or the warranty card. To get repair service or a complete copy of the warranty statement, please contact with your nearest RIGOL sales and service office. RIGOL does not provide any other warranty items except the one being provided by this summary and the warranty statement. The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose. RIGOL will not take any responsibility for cases of indirect, particular and ensuing damages. 14