Power Quality For The Digital Age 21ST CENTURY PROTECTION. An Environmental Potentials White Paper

Similar documents
22.0 Harmonics in Industrial Power Systems

Common Mode Susceptibility of Computers

Distribution Transformer Random Transient Suppression using Diode Bridge T-type LC Reactor

POWER QUALITY A N D Y O U R B U S I N E S S THE CENTRE FOR ENERGY ADVANCEMENT THROUGH TECHNOLOGICAL I NNOVATION

Power Quality Basics. Presented by. Scott Peele PE

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

NJWA - Harmonics and Drives Proper System Design

Application Note. Applicable Product: AC Drives

Low Pass Harmonic Filters

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Harmonics White Paper

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

What are Transients & How to eliminate them from Power System?

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

ULTRA-K Series 600K - he

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

Harmonic Filters for Single Phase Equipment

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

Active Elimination of Low-Frequency Harmonics of Traction Current-Source Active Rectifier

Use of Advanced Unipolar SPWM Technique for Higher Efficiency High Power Applications

Minimizing Input Filter Requirements In Military Power Supply Designs

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

World Academy of Science, Engineering and Technology International Journal of Electrical and Computer Engineering Vol:7, No:6, 2013

1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)

Speed Control of Induction Motor using Multilevel Inverter

Figure 1 Typical Inverter Block Diagram

AC Drives and Soft Starter Application Guide

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

An Active Interphase Transformer for 12-Pulse Rectifier System to Get the Performance Like 24- Pulse Rectifier System

3 PHASE INVERTER WITH 180 AND 120 CONDUCTION MODE

Power Factor Pre-regulator Using Constant Tolerance Band Control Scheme

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Understanding Input Harmonics and Techniques to Mitigate Them

Harmonic Analysis to Improve Power Quality

CSX RAILROAD NASHVILLE YARD RAIL WELDING MACHINE POST INSTALL SURGE SUPPRESSION POWER QUALITY STUDY

Chapter 1: Introduction

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

Economical Solutions to Meet Harmonic Distortion Limits[4]

Design and Simulation of Synchronous Buck Converter for Microprocessor Applications

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Reduce Load Capacitance in Noise-Sensitive, High-Transient Applications, through Implementation of Active Filtering

Active Harmonic Filter (AF3)

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

Introduction to Harmonics and Power Quality

Power Quality enhancement of a distribution line with DSTATCOM

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

5000 series Signal Isolation

Electromagnetic Harmonic Filters Technical Guide

Harmonic mitigating transformers. Energy savings through harmonic mitigation

TS RES - OUTSTANDING ISSUES

High Performance ZVS Buck Regulator Removes Barriers To Increased Power Throughput In Wide Input Range Point-Of-Load Applications

Understanding Harmonics

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI)

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

UNIT-3. Electronic Measurements & Instrumentation

Lecture 19 - Single-phase square-wave inverter

An Oscillator Puzzle, An Experiment in Community Authoring

All Servos are NOT Created Equal

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Technical Brief: Flow Direction of Harmonics and High- order Harmonics

Caution - leakage currents! Leakage currents in fault-current protected environments

Harmonic Solutions. Clean Power Drive Solution to Harmonic Distortion

An Oscillator is a circuit which produces a periodic waveform at its output with only the dc supply voltage at the input. The output voltage can be

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

Advanced Topics in EMC Design. Issue 1: The ground plane to split or not to split?

A New Concept of Power Quality Monitoring

Power Protection and Conditioning

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

EMC of Power Converters

CHAPTER 5 CONTROL SYSTEM DESIGN FOR UPFC

POWER FACTOR CORRECTION AND HARMONIC CURRENT REDUCTION IN DUAL FEEDBACK PWM CONTROLLED AC/DC DRIVES.

THREE-PHASE converters are used to handle large powers

A Novel Automatic Power Factor Regulator

VSWR MEASUREMENT APPLICATION NOTE ANV004.

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

Pulse Width Modulated Motor Drive Fault Detection Using Electrical Signature Analysis

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

Achopper drive which uses the inductance of the motor

Power Quality Solutions

LINEATOR. Advanced Universal Harmonic Filter

Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses

Although shunt capacitors

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Voltage and Current Waveforms Enhancement using Harmonic Filters

POWER QUALITY AND SAFETY

UNDERSTANDING POWER QUALITY

Exclusive Technology Feature. Integrated Driver Shrinks Class D Audio Amplifiers. Audio Driver Features. ISSUE: November 2009

Analysis of Harmonic Distortion in Non-linear Loads

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

1C.4.1 Harmonic Distortion

Coupling modes. Véronique Beauvois, Ir Copyright 2015 Véronique Beauvois, ULg

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Fundamentals of Power Quality

PHYS 235: Homework Problems

Differential-Mode Emissions

Transcription:

Power Quality For The Digital Age 21ST CENTURY PROTECTION An Environmental Potentials White Paper www.ep2000.com 800.500.7436

Situation The modern facility has undergone radical changes in the past 50 years, the biggest change is to equipment. Modern equipment is computerized, digital and electronic. This equipment is nonlinear in nature. Nonlinear loads are designed with fast acting switching devices such as diodes, IGBT s. Switching devices result in non-sinusoidal currents and frequency noise. This frequency noise is also called switching frequency noise (since it s the result of switching devices). Switching frequency noise is neither constant in magnitude nor constant in time intervals. This type of noise is indoor power pollution and constitutes 85% of the total power disturbances threatening a facility. 20th Century Solutions For the past 50 years design engineers have been comfortable using legacy devices. The most common devices are known as SPD s (surge protective devices), TVSS (transient voltage surge suppressors), isolation transformers and harmonic filters. All of these technologies function similarly and none of these products solve the 21st century problem of indoor power pollution. SPD s and TVSS have limited, if any, filtering capability and merely provide high energy events with a path to ground. This is very harmful to computerized, electronic and digital equipment that reference ground for proper operation. This will result in ground currents circulating throughout the facility. Legacy filters like harmonic filters, use capacitors which create switching noise in the system. Isolation transformers used in the facility add ground loops to the system while amplifying the electrical noise on phases. This high frequency noise is detrimental the sinusoidal nature of the waveform. The 21st Century Problem: Internal Power Pollution While the biggest threats to the electrical system in the 20th century may have been extreme events such as lightning, the biggest threat to the electrical system in the 21st century is internal power pollution. Electrical noise and ground loops are examples of internal power pollution. Internal power pollution constitutes approximately 85% of the total power disturbances. Nonlinear loads generate non-sinusoidal current, full of harmonics and frequency noise. Ground loops are generated when there is mismatch in the electrical configurations of load and supply. While many facilities suffer from ground loops, all facilities have nonlinear loads. Internal power pollution is responsible for equipment malfunction, electrical losses, decreased equipment life cycles, downtime and increased maintenance costs.

All of the available filters in the market today use ground as their termination point for electrical noise. Ground is connected to the other parts of the system such as system casings and motor chassis. Unwanted noise or transients diverted to ground will cause currents to circulate throughout the facility and this can cause equipment malfunctions and shortened equipment lifecycles. This means the filters which are supposed to be protecting facilities are actually responsible for creating ground loops. Environmental Potentials patented waveform correction technology does not divert energy to the ground instead, EP s patented technology converts internal power pollution into heat within the unit. Independent Testing Electrical Systems Analysis (ESA), an independent testing agency, tested EP s waveform correction technology and compared it with two widely used products, Cutler Hammer and Psytronics, to discover which product if any had a solution for internal power pollution. The results in figure 1 demonstrate that EP substantially lowers and expands peak voltage. This provides sufficient time to dissipate the noise within the unit. Other products in the market such as CH and PSY are not able to lower noise or expand the peak voltage to a permissible limit. The peak voltages are 648V for EP, 1000V for CH and 1350V for PSY respectively. This means CH and PSY offer no significant protection/ filtration for an A1 ring wave. The term let through voltage indicates the maximum voltage a device allows to reach your equipment after noise reduction. A low let through voltage number indicates a greater level of protection/filtration and vice versa. EP s let through voltage is 48V where as it is 388V for CH and 724V for PSY. Figure 1: 5uS voltage rise time with 100 khz ring, a 2kV peak voltage under open circuit, and supplying 70 A under short circuit conditions. This test represents a disturbance waveform that is representative of waveforms generated by non-linear loads and switching.

Compare the let through voltage numbers in figure 2. EP clearly outperforms the competition. CH s let through voltage is approximately 8 times that of EP, while PSY s let through voltage is more than 10 times that of EP. Cutler Hammer EP2000 Psytronics Phase Baseline Peak Let Through Baseline Peak Let Through Baseline Peak Let Through Figure 2 90 degrees 590 996 406 604 668 64 580 1304 724 576 996 420 592 668 76 580 1328 748 580 984 404 580 632 52 568 1320 752 588 980 392 604 656 52 576 1328 752 580 984 404 604 668 64 576 1328 752 180 degrees 32 432 400 28 76 48 0 1272 1272 44 444 400 4 64 60-56 1272 1328-44 344 388 28 112 84-48 1272 1320 56 444 388-56 4 60 16 1272 1256 44 432 388-4 76 80-56 1272 1328 270 degrees -632-212 420-628 -544 84-648 1184 1832-620 -212 408-628 -544 84-648 1168 1816-596 -204 392-628 -560 68-632 1168 1800-620 -212 408-628 -544 84-632 1160 1792-620 -212 408-620 -544 76-632 1168 1800 Noise between 1-100kHz EP focuses on removing electrical noise in the 1-100kHz range. This noise range is the most damaging to computer, digital and electronic loads. The noise generated in this region was used to represent noise reflected into the facility power distribution system by facility loads such as AC adjustable frequency drives, DC drives, rectifiers, electronic ballast, switching power supplies and arcing contactors. ESA tested the ability of all three products to remove this noise. Figure 3: Uniform noise generated from 1kHz to 90 khz Figure 3 shows the 1 khz to 90 khz uniform random noise spectrum when no device is connected. This noise was superimposed on a 60 Hz fundamental waveform.

Figure 4: Response of CH for 1-90 khz uniform noise on sinusoidal wave Figure 4 shows the response of the CH device. It has a broad resonant peak centering around 48kHz. At its peak, it amplifies the signal about 2 times. The CH device is not performing any filtering action in this range of frequency (typical drive switching frequency and switching frequency harmonics), as there is no drop of the noise significantly below -75dB, or the level of the noise alone with no device connected. Figure 5: Response of PSY for 1-90 khz uniform noise on sinusoidal wave Figure 5 demonstrates that the Psytronics unit offers no filtering and appears as an open circuit in the 1 khz to 90 khz range.

Figure 6: Response of EP for 1-90 khz uniform noise on sinusoidal wave EP clearly shows a frequency filtering response. It has a resonant peak centered at about 24kHz, which is much narrower and will cause less amplification of a broad range of frequencies. EP also shows significant filtering as the noise spectrum drops well below the -77 db point. At 70 khz EP is 19 db lower than 77dB and this is nearly a 10 times reduction of noise. The 21st Century Solution EP s patented technology is a two part circuit, one being a high frequency low pass filter and the other being a powerful rugged protector in the event of catastrophic events. The protector offers complete protection from catastrophic events. The low pass filter operates 24 hours a day, seven days a week filtering internal power pollution. This is an understated, yet industry changing leap in technology. EP s protection circuit is completely protected by the filtration circuit which makes the unit durable for all noisy environments. The EP system is the most robust, functional electrical distribution system overlay ever designed. Environmental Potentials bridges the gap between high voltage AC distribution and low voltage DC loads. It is the answer for the damaging, residual footprint that each switching cycle leaves behind. Environmental Potentials patented waveform correction technology is the only solution for internal power pollution. www.ep2000.com 800.500.7436

1-800-996-3762 info@ep2000.com www.ep2000.com 800.500.7436 www.ep2000.com 1802 N. Carson Street, Suite 108-2987 Carson City, NV 89701