MCR 702. T Rheometer

Similar documents
MCR 702. T Rheometer

MCR. The Modular Compact Rheometer Series. ::: Intelligence in Rheometry

TA Instruments RSA-G2 Dynamic Mechanical Analyzer

Introduction to Measurement Systems

INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE Jadavpur, Kolkata Tender No.: IACS/BC/PKD/DST/ Date:

AlphaProx inductive sensors. Measure distances accurate to a micrometer.

A Technique for Rapid Acquisition of Rheological Data, and its Application to Fast Curing Systems

Feedback Devices. By John Mazurkiewicz. Baldor Electric

5. Transducers Definition and General Concept of Transducer Classification of Transducers

AlphaProx inductive sensors. Measure distances accurate to a micrometer.

Smart Viscous Dampers utilizing Shear Thickening Fluids with Silica Nanoparticles

Product data sheet Palas Fidas 200 E

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Standard Test Method for Rubber Measurement of Unvulcanized Rheological Properties Using Rotorless Shear Rheometers 1

ED-17 Serial Output Magnetic Encoder

Generator Advanced Concepts

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Synchronous Machines Study Material

Product Information. ERN 1085 Incremental Rotary Encoder with Z1 Track

ACTUATORS AND SENSORS. Joint actuating system. Servomotors. Sensors

T A I N S T R U M E N T S

T40FH. Torque flange. Special features. Data sheet

Final Publishable Summary

NVH analysis of a 3 phase 12/8 SR motor drive for HEV applications

RoHS. High shaft load capacity. Shock / vibration resistant

Study of Vee Plate Manufacturing Method for Indexing Table

3.1.Introduction. Synchronous Machines

MEMS Optical Scanner "ECO SCAN" Application Notes. Ver.0

Sensors and Sensing Motors, Encoders and Motor Control

Top-Innovator EncoderAnalyzer. For testing encoders. Made in Germany Expect more. Winding testers

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.

MIG Encoders BEGE MIG NOVA+ Your drive, our (trans)mission. BEGE Power Transmission

MCP 200, MCP 300, MCP 500

T40B. Torque Flange. Special features. Data sheet. Overall concept

Operating Instructions

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

TETRA COMPACT - E AND FLEXI - PRO

Lab Exercise 9: Stepper and Servo Motors

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS

High-speed rotary bell atomization of Newtonian and non-newtonian fluids

BTA Rotary Actuators. Torque - mnm. 100% Duty Cycle. 25% Duty Cycle 5 50% Duty Cycle 2

CHAPTER 6 FABRICATION OF PROTOTYPE: PERFORMANCE RESULTS AND DISCUSSIONS

Flexibility and efficiency on high accuracy machining

Product Information ECN 424 S EQN 436 S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications.

Application Note 01 - The Electric Encoder

Universal. CNC Turning machine TNA400

Job Sheet 2 Servo Control

PVA Sensor Specifications

Principles of operation 5

Product Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications

QR12. Output. A = Line Driver B = Line Driver ABZ/ Open Collector UVW C = Sin/Cos/ Line Driver UVW D = Sin/Cos/Open Collector UVW

ON THE PERFORMANCE OF LINEAR AND ROTARY SERVO MOTORS IN SUB MICROMETRIC ACCURACY POSITIONING SYSTEMS

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

Electronic Systems - B1 23/04/ /04/ SisElnB DDC. Chapter 2

ELECTRONIC SYSTEMS. Introduction. B1 - Sensors and actuators. Introduction

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

CONTROLLING THE OSCILLATIONS OF A SWINGING BELL BY USING THE DRIVING INDUCTION MOTOR AS A SENSOR

Electronic Instrumentation and Measurements

absolute encoders and motors for -80 C

3. HIWIN rotary tables TMS

Course of Instrumentation. and Measurement. National School of Engineers of Tunis ENIT. Karim Bourouni. Dipl.Dr-Ing.

Product Information ECN 424 S EQN 436 S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications

As before, the speed resolution is given by the change in speed corresponding to a unity change in the count. Hence, for the pulse-counting method

Product Information. EBI 1135 Absolute Rotary Encoder, Multiturn Feature via Battery-Buffered Revolution Counter

Step vs. Servo Selecting the Best

1. Explain in detail the constructional details and working of DC motor.

General catalog. BESMAK Servo-hydraulic Medium-Capacity fatigue test System with Furnace. 1 BESMAK Material Testing Machines

MAGNETOSCAN MAGNETIC MEASURING SCANNER

discovery hybrid rheometers

Product Information. ECN 1313 ECN 1325 ERN 1387 Rotary Encoders with Plane-Surface Coupling for Elevator Servo Drive Control

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

MA3. Miniature Absolute Magnetic Shaft Encoder Page 1 of 8. Description. Order Using #MA3 starting at $36.00 per unit. Features

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Smooth rotation. An adaptive algorithm kills jerky motions in motors.

AVL X-ion. Adapts. Acquires. Inspires.

Magnetic Force Compensation Methods in Bearingless Induction Motor

Instrumentation (ch. 4 in Lecture notes)

The ZSH stepper motor convinces with its robust housing with high-strength cable gland. The motor is waterproof up to 10 m with the IP68 option.

TETRA COMPACT - E AND FLEXI - PRO THE ENHANCED SERVO BUNDLE

Fig. 1 In some areas, the highly accurate torque motors can replace hydrostatic drives

Motor Repair Electrical Engineering Maintenance

ELECTROFORCE TEST SYSTEMS

Data Sheet. AEDT-9340 Series High Temperature 115 C 1250/2500 CPR 6-Channel Commutation Encoder. Description. Features.

Product Information. ECN 413 ECN 425 ERN 487 Rotary Encoders for Elevator Drive Control (IP64 Degree of Protection)

CHAPTER 5 FAULT DIAGNOSIS OF ROTATING SHAFT WITH SHAFT MISALIGNMENT

Motion Control Glossary

ABSOLUTE MAGNETIC ROTARY ENCODER ANALOG

EC 45 flat with integrated electronics Document ID: en Operating Manual

JR12 Jam Nut Mount Optical Encoder

MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION WHEEL

SYNCHRONOUS MACHINES

Introduction. ELCT903, Sensor Technology Electronics and Electrical Engineering Department 1. Dr.-Eng. Hisham El-Sherif

Compact drives. Rotary actuators

MX460B-R. Rugged pulse and frequency measuring module. Data sheet. Special features. Block diagram

COVENANT UNIVERSITY NIGERIA TUTORIAL KIT OMEGA SEMESTER PROGRAMME: MECHANICAL ENGINEERING

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

THE STUDY OF THE SYNCHRONOUS MOTOR

Printing versus coating technology Which way Printed Electronics with solution coating will go?

1. This is an integrated product combining a bearing with a rotation sensor that detects the speed and direction of rotation.

Transcription:

MCR 702 T Rheometer

One Rheometer. Two Drives. All Possibilities. MCR 702 with T Technology

The rheometry revolution: T Anton Paar introduces a groundbreaking high-end rheometer in a class of its own: MCR 702 with T technology. For the first time ever in the history of rheometry, you can perform rheological tests with two torque transducers and drive units at once, in a single instrument: Two powerful EC motor units in a combined modular setup flexible and precise enough to deliver any result you are looking for. In short, MCR 702 with T is the first single system to cover all possible rheological applications past, present and future.

The Modes that Make it Possible The single-drive mode The single-drive test mode provides you with the vast range of application options that MCR rheometer are known for. In this mode, the lower motor is simply removed and MCR 702 is operated as a CMT (Combined Motor Transducer) rheometer. Using a single air-bearing-supported EC motor unit, you can make the most of the motor s TruStrain capability and perform classic stress-controlled tests. The option to either control the shear rate or the shear stress opens up countless applications specific to single-motor rheometers. The single-drive MCR 702 is ready for any temperature device and application-specific accessory you may require and there are more than 35 options to choose from The T modes Now anything is possible: The T modes mark a rheological testing. The counter-rotation mode In the counter-rotation mode, MCR 702 employs both airbearing-supported EC motors as drive units as well as torque transducers. The two motors are easily set to rotate in opposite directions, with the preset speed divided and shared. This counter-rotation can be used to create a fixed stagnation plane in a sample, which is then easier to investigate microscopically. This mode is also used with UXF T, for extensional tests down to minimal measured torques. Regarding speed, the counter-rotation mode simply doubles the score up to a maximum speed difference of 6000 rpm. measuring measuring driving driving measuring driving

game change in the world of rheometry, allowing you to break unprecedented new ground in The counter-oscillation mode In the counter-oscillation mode, MCR 702 also employs both motors as drive units and torque transducers while performing a counter-oscillatory movement. This means that the set strain is divided equally between both motors so that they each move at half of the set strain while maintaining the same frequency. In comparison to the single-drive mode, this movement allows you to measure at higher strains within the sample in order to characterize samples which require torques at the maximum limits of the EC motor. Furthermore, the movement allows the production of a stagnation plane in oscillation, which can be used for optical investigations. The separate motor transducer mode The Separate Motor Transducer (SMT) mode enables you to use the motors in a more synchronized fashion, making different demands on each of them. Because of the EC motors outstanding precision, one motor is easily brought to a fixed position and operated solely as a torque transducer, while the other motor is used as a drive unit only. This turns MCR 702 into the best available SMT rheometer for rotational and oscillatory tests, at the unrivaled torques and normal forces offered by Anton Paar's EC motors only. measuring measuring driving measuring driving driving

Complete Gap Control IsoLign : Nano-scale precision MCR 702 T is the first rheometer to offer nano-scale precision on several counts such as low-torque measurements down to a minimum of 1 nnm and the control of angular deflections down to 50 nrad. Now this peak precision also extends to the system s measuring gap control: The new IsoLign Piezo flange performs gap size changes as small as 10 nm. Based on a system of 3 Piezo elements in the flange of the measuring chamber reception, IsoLign is reliably employed in all test modes. Common step-motor-based systems employ a long kinematic chain to translate single motor steps into gap size changes in the micrometer range. Capable of step sizes down to 10 nanometers, IsoLign is decades more precise than any other comparable solution for gap size adjustments in rheological tests. In tests across vast temperature ranges, the measuring gap is kept constant within lower tolerances than ever before. TruGap : Consistent gap control The patented TruGap system (US Patent 6,499,336) consistently measures and precisely adjusts MCR 702 s measuring gap to the desired position independently of temperature and thermal expansion. Permanent control, documentation and traceability of the actual measuring gap are guaranteed, eliminating the need for regular zero-gap settings.

Expand Your Possibilities: Application-specific Accessories for T Modes Cone Partitioned Plate The Cone Partitioned Plate (CPP) for MCR 702 T has a special design which limits the impact of edge fracture effects when characterizing viscoelastic samples. It enables oscillatory and rotational measurements even at deformations/shear rates which would result in an incomplete filling of the active measuring zone in conventional measuring geometries. It therefore increases the analyzable range of amplitude sweeps (large amplitude oscillatory shear LAOS), step rate tests, and also flow curves in comparison to the usual parallel-plate or cone-plate geometries. SRF T: Solid Rectangular Fixture The Solid Rectangular Fixture for MCR 702 T (SRF TD) allows DMA (dynamic mechanical analysis) measurements on solid bars using both motors. This extends the frequency range for some viscoelastic samples due to the fact that the excitation is separated from the torque measurement. Furthermore, the concept offers the characterization of material properties from the glassy to the rubber state including the determination of glass transition temperatures and the onset of melting as accurately as possible.

Rheo-Microscopy for MCR 702 T Watch the video Using the rheo-microscopy setup for T opens up entirely new views. You can apply the rheometer s counter-rotation mode to produce a stagnation plane in which the observed structure is sheared but remains in a fixed position. This stagnation plane constantly keeps the focused structure in the microscope s field of view while accurate rheological data is obtained. Using the speed balance, you can also change the speed distribution between the two drives and move interesting structures back into your field of view, while keeping the shear rate constant. UXF T: Extensional Rheology Fixture The Universal Extensional Fixture (UXF) enables extensional rheological measurements with unprecedented torque and strain resolution when using MCR 702 T in its counter-rotation mode. While the established SER system is perfectly suitable for extensional tests at high torques, UXF T opens up new possibilities for measurements of low-viscosity films and fibers and allows for entirely new test procedures such as stress relaxation tests in extension. The obtained data perfectly matches the theory; in addition, the system is sensitive enough to measure the influence of sagging at long relaxation times, which can also be observed using a CCD camera. Watch the video

Flow Visualization with MCR 702 T Watch the video Most rheological calculations are based on the assumption of laminar flow, although more uncommon sample behavior like shear banding is often reported in recent experiments. The visualization of flow is therefore a highly important tool to understand these new flow effects. MCR 702 T can be used in all test modes together with a transparent concentric cylinder. This measuring system is a perfect configuration for observing your sample from all sides while sheared. The study of the onset of flow instabilities is therefore an interesting potential application when measuring with such a configuration. Dielectro-Rheological Device The Dielectro-Rheological Device (DRD) for MCR 702 T can be used in all modes, also in the single-drive mode, for combining dielectric spectroscopy and rheology. The DRD enables you to investigate the influence of mechanical deformation on samples conductivity, capacity and permittivity. This setup can be used to analyze the influence of flow and deformation forces on the dielectric spectra of your sample and to investigate material properties in a range less accessible to mechanical analysis. The DRD accessory comes with different contact options to allow for use in rotational as well as oscillatory tests.

T The Key to Accuracy

Rapid control and vast torque capabilities The air-bearing-supported synchronous EC motor is the key to MCR 702 s performance providing rapid control and vast torque capabilities from 230 mnm down to 1 nnm. The rotor of the EC motor drive is equipped with permanent magnets. In the stator, coils with opposite polarity produce magnetic poles. The magnets in the rotor and stator coils attract each other, so that a rotating flux of current in the coil windings produces a frictionless synchronous rotor movement. The torque of the motor is set and measured via the input current to the stator coils. Due to its unique design, the EC motor features a linear relation between the torque and the input current to the stator coil a great advantage for precise torque control and measurement. For increased testing flexibility, the motor is easily and reliably set to move in two respective directions. Its rapid, accurate control and its extremely wide torque range make the EC motor the ultimate torque transducer in SMT applications. The air bearing Two air bearings surround and support each motor: A radial air bearing centers and stabilizes the shaft; an axial air bearing holds the weight of the rotating parts. Specifically optimized for rigidity, drift stability and robustness, the MCR rheometers air bearing technology together with improved torque scanning enables low-torque measurements down to a minimum of 1 nnm. Measuring point durations of 1 ms The use of the most recent processor technology in MCR 702 increases the speed of data processing and enables measuring point durations of 1 ms, increasing the efficiency of transient tests. Angular deflections down to 50 nrad The normal force sensor The high sensitivity and increased sampling rate of the normal force sensor integrated in the air bearing enables normal force measurements during transient and steady-state tests as well as static normal force measurements for gap control and DMTA, tack or penetration tests. The sensor employs an electric capacity method, precisely converting extremely small deflections in the air bearing into the according normal force. Instead of enforcing additional travel, the natural movement already present in the air bearing is used to measure the normal force. The advantage of the sensor s location in the air bearing: Normal force measurements are available for all temperature devices and application-specific accessories, as well as in both motor units in all applications. TruRate The MCR series TruRate sample-adaptive controller intelligently adapts to the sample conditions at hand in rotational tests. Without prior information on the sample, the desired settings for strains and shear rates are achieved in minimum time and without overshoots. TruStrain The system s TruStrain functionality allows real-time processing of oscillatory strains. In oscillation, TruStrain employs real-time position control based on the Direct Strain Oscillation (DSO) method. This means you are able to preset and control precisely sinus-shaped strains both within the linear viscoelastic (destruction-free) range as well as in LAOS (Large Amplitude Oscillatory Shear) conditions. Full transparency about both drives in software The software for the MCR rheometers not only allows you to display all rheological data, it also provides full transparency regarding all physical parameters of both active drives. This transparency always gives you an inside look into the rheometer control. A high resolution optical encoder based on data oversampling technology enables the measurement and control of smallest speeds and angular deflections down to 50 nrad.

Build on Your Rheometer: Application-specific Accessories for the Single-drive Mode Structure Analysis Gather sample structure information by combining these optical and dielectric methods with rheology. Rheo-Microscopy (Fluorescence, Polarized, Non-Polarized) Small-angle light scattering (SALS) Small-angle X-ray scattering (SAXS) Small-angle neutron scattering (SANS) Additional Parameter Setting Employ these accessories to set additional parameters together with the temperature for rheological tests. Pressure cells UV Curing System Immobilization Cell Magneto- Rheological Device Extended Material Characterization These accessories transfer the MCR rheometer s measuring capabilities into other material characterization applications. Extensional rheology Dynamic mechanical thermal analysis (DMTA) Starch rheology Large-particle rheology

Obtain additional structure information, set additional parameters or employ the rheometer s functionality for further material characterization: This wide range of application-specific accessories is easily integrated into your MCR rheometer. MCR Application-specific Accessories for Structure Analysis Particle image velocimetry (PIV) Polarized Imaging Dielectro- Rheological Device (DRD) MCR Applicationspecific Accessories for Additional Parameter Setting Electro- Rheological Device Humidity Option for CTD 180 MCR Extended Material Characterization Interfacial rheology Tribology: Ball on three plates Pin on disk Four ball Powder Cell

New Paths for Your Applications The RheoCompass Software Your rheometer opens up a constantly growing number of measurement opportunities. This calls for a navigation tool that gives you the complete overview as well as the exact insights you require: Anton Paar s new RheoCompass software, the most innovative and up-to-date rheometer software available on the market. Designed for intuitive use, RheoCompass enables application-oriented template filtering, customized test and analysis definitions, highly simplified data retrieval and much more.

Specifications MCR 702 T Unit EC motor (brushless DC) with high resolution optical encoder and air bearing - Permanent torque (60 min), no signal drift - Controlled shear rate and shear stress - Single-drive Mode T Mode IsoLign Piezo flange - Gap size change nm 10 10 Maximum torque mnm 230 230 Minimum torque, rotation nnm 1 5 (SMT) Minimum torque, oscillation nnm 0.5 1 (SMT) Angular deflection, set value µrad 0.05 to 0.05 to Step rate, time constant ms 5 5 Step strain, time constant ms 10 10 Step rate, time to reach 99 % of set value (independent of sample) ms 30 30 Minimum angular velocity, controlled (1) rad/s 10-9 10-9 Maximum angular velocity, controlled rad/s 314 2 x 314 Minimum angular frequency (2) rad/s 10-7 (3) 10-7 (3) Maximum angular frequency rad/s 628 628 Normal force range N 0.005 to 50 0.001 to 50 Counter-rotation Counter-oscillation Toolmaster TM (US Patent 7,275,419), measuring system and measuring cell (wireless detection and transmission of measuring system and calibration parameters) QuickConnect for measuring systems, screwless - Electronic trim lock for the measuring system - TruRate TM TruStrain TM Normal force and velocity profiles, tack, squeeze - Automatic gap control/setting, AGC/AGS - Dimensions mm 753 x 444 x 586 753 x 444 x 586 Weight kg 47 56 Depending on your application and test mode, MCR 702 T can be operated with... Direct strain, amplitude controller - Direct stress, amplitude controller - Raw data (LAOS, waveform,...) - Digital Eye video option and camera - Maximum temperature range C -160 to +1000 Pressure range bar up to 1000 Structure Analysis (Microscope, SALS, SANS, Birefrigence, PIV,...) Additional Parameter Setting (UV, Magneto- and Electro-Rheological Device,...) Extended Material Characterization (DMTA, Tribology, ) - - - Connections USB, Ethernet, 4 analog interfaces, 2 auxiliary inputs, Pt 100 and thermocouple interfaces (1) Depending on measuring point duration and sampling time practically any value is achieved (2) Set frequencies below 1.0E-04 rad/s are of no practical relevance due to the measuring point duration > 1 day (3) Theoretical value (duration per cycle = 2 years) Legend: optional not available included