Large-Capacity, High-Efficiency 3-Level UPS for North America 7000HX-T3U

Similar documents
Uninterruptible Power System (UPS) 20 to 320 kva

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

TOSHIBA International Corp

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

All IGBT Type Fuji Large-capacity UPS. UPS6000F Series. Three-phase 100 to 1,000kVA. REC 82-2d

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

B9000 FXS kVA B9600 FXS kVA

Floating Output DC-DC Converter Using Single Winding Reactor and Its Applications

TECHNICAL DATA SHEET B9600FXS kva

Development of Transformerless Multi-Level Medium Voltage Inverters

Est Static Frequency Converter. SFX 10kVA - 10MVA

Simulation Technology for Power Electronics Equipment

Low Pass Harmonic Filters

Est Static Frequency Converter. SFX 10kVA - 10MVA

Development of Small-Capacity UPS "SANUPS A11G-Ni"

UPS Uninterruptible Power System

Modern Concepts of Energy Control Technology through VVVF Propulsion Drive

Technical Data Sheets

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

Power Regenerative Converter, THYFREC CV240S

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS

3rd-Gen. Critical Mode PFC Control IC FA1A00 Series

Power Meter PW3335. Ken Sakai Engineering Division 4, Engineering Department. Power Meter PW3335

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

Power Protection and Conditioning

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

Introduction to HVDC VSC HVDC

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

The new Yaskawa Varispeed G7 Inverter

SUPERCONDUCTING MAGNETIC ENERGY

All-SiC Modules Equipped with SiC Trench Gate MOSFETs

STANDBY MODE OFF MODE. POWER HiTESTER. Accurate evaluation of consumption power of electrical products. An Energy Saving Support Tool

G-NET. 1 kva-10 kva. Rack & Tower UPS

Evaluation of transformer-free UPS design vs transformer-based

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Thyristorised Automatic Power Factor

Pulse Width Modulated Motor Drive Fault Detection Using Electrical Signature Analysis

R&D TECHNICAL SPECIFI

LCE-MBP-400. User Manual. TDI Transistor Devices Inc. 85 Horsehill Road, Cedar Knolls, NJ USA Phone: Fax:

USER S MANUAL. 3KSS6050/ nd Edition

GESS Industrial UPS System. Overview

Research and Trends in Power Quality

USER S MANUAL. 1KSS60400/ ST Edition

Currency Identification Device for Global Markets FGC Series and FGB Series

6th Generation Power MOSFET Super FAP-E 3S Low Q g Series

TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION

MGETM EPSTM /625/750/800 kva. Three phase UPS

High Power IGBT Module for Three-level Inverter

ETSI EN V1.2.1 ( )

PrimePACK of 7th-Generation X Series 1,700-V IGBT Modules

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

Reliable power onboard and offshore

Orbital GFI Inverter Series

IEEE-ICIT 2010 CHILE A New Medium Voltage Drive System Based on ANPC-5L Technology

MONTRANO. Continuous monitoring system for power transformers

Modern Hardware Technology in Inverters and Servo Systems

Wide-band Models from DC to 100 MHz

DC/DC-Converters in Parallel Operation with Digital Load Distribution Control

CHAPTER 1 INTRODUCTION

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

will do its best to manufacture products in excellent quality with continuous R & D.

Modeling of Conduction EMI Noise and Technology for Noise Reduction

A Half Bridge Inverter with Ultra-Fast IGBT Module Modeling and Experimentation

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

UNINTERRUPTIBLE POWER SUPPLY SINGLE MODULE SYSTEM SPECIFICATIONS MODEL 9800AE

Part Five. High-Power ac Drives

Liebert THE NEW LEADER IN THREE-PHASE UPS PRODUCT. Npower. 30 to 130 kva. True Double Conversion. Exceptional Reliability. Unmatched Performance

Chloride. FP-50z 5 160kVA Industrial AC UPS

DC Link. Charge Controller/ DC-DC Converter. Gate Driver. Battery Cells. System Controller

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

World-Class Accuracy & Measurement Range (40 Conventional Models)

INTERNATIONAL JOURNAL OF ENHANCED RESEARCH IN SCIENCE TECHNOLOGY & ENGINEERING VOL. 2 ISSUE 2, FEB ISSN NO:

Critical Mode PFC Control IC FA1A60N and LLC Current Resonant Control IC FA6B20N for High-Efficiency Power Supplies

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Gutor PxW AC UPS Designed for North American Market

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

SHUNT ACTIVE POWER FILTER

7th-Generation X Series RC-IGBT Module Line-Up for Industrial Applications

M-Power 2A Series of Multi-chip Power Devices

COURSE NOTES Testing Compliance to Energy Efficiency Standards

TMdrive -XL Series Family Product Application Guide. solar inverters. power generation

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Switches And Antiparallel Diodes

Wide-band Models from DC to 100 MHz

STATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

(a) All-SiC 2-in-1 module

Renewable Interconnection Standard & Experimental Tests. Yahia Baghzouz UNLV Las Vegas, NV, USA

Strategies for design 600V large modular UPS for critical power applications

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

Obsolete Product(s) - Obsolete Product(s)


Transcription:

Large-Capacity, High-Efficiency 3-Level for North America 7000HX-T3U KAWASAKI, Daisuke HAMADA, Ippei SATO, Atsushi ABSTRACT Due to the development of information and communications systems in the information society in recent years, the data center market is expanding both in Japan and abroad. At the same time, there are increasing needs for uninterruptible power systems (s) to ensure stable system operation. 7000HX-T3U, which has been developed for the North American market, is a large-capacity, high-effi ciency using a 3-level power conversion circuit with a rated voltage of 480 V. By using Fuji Electric s original AT-NPC 3-level insulated gate bipolar transistor (IBT) module, the has achieved a maximum effi ciency of as high as 97%. It provides high reliability, as with the conventional models, and also supports UL and NEC standards which must be complied with in North America. issue: Power Electronics 1. Introduction Information communication systems, such as those used in communication equipment and networks, have an indispensable role in today s information-driven society. Social activities could be significantly impacted if these systems were to stop working, and stable operation is thus an absolute requirement. An uninterruptible power system () plays a major role in information communication systems, and it is an essential piece of electrical equipment needed in supplying a stable source of power in data centers 24 hours a day, 365 days a year. In recent years, the market size and growth rate of data centers, while still comparatively small in Japan, has been growing in Asia and North America, and it is expected that considerable growth will be sustained into the future. Fuji Electric has developed s for the Japanese, Asian and North American markets. This paper describes the 7000HX-T3U, a highefficiency with a high-capacity rated voltage of 480 V developed for use in the North American market (see Fig. 1). 2. Features 2.1 Compliance with North American standards When developing products for use in North America, it is strictly required that they be compliant with the product safety standards of Underwriters Laboratories Inc. (UL standards), as well as the standards related to cable laying prescribed by the National Fire Protection Association (NEC standards). In order to make the described in this paper compliant with these standards, we carried out the selection and development of new device components. 2.2 High efficiency The current model maintains the world s highest level of efficiency at 97%, being based on the exact same features as the 7000HX-T3, a previous product developed for the Japanese market. The high equipment efficiency not only decreases the power loss of the, but also reduces the power consumption of air conditioning equipment used to cool the. Since equipment in a data center adopts dual and redundant configurations to improve reliability of the system, it operates at a low load factor. Power loss is also reduced in the low load range (20% to 50%) during normal operation. Fig.1 7000HX-T3U (400 V, 500 kva) Power Electronics Business roup, Fuji Electric Co., Ltd. 2.3 High reliability In data centers, the needs to continuously supply power 24 hours a day, 365 days a year. This 17

No. 2 AC input No. 1 AC input No. 2 power generator No. 1 power generator No. 2 AC input No. 1 AC input No. 2 power generator No. 1 power g enerator No.3 No.2 No.1 Bypass circuit for maintenance Primary use No. 2 Primary use No. 1 Standby No. 2 bus switchgear No. 1 bus switchgear No. 2 AC output No. 1 AC output 3 phase, 3 wire 480 V 3 phase, 3 wire 480 V No. 2 AC output 3 phase, 3 wire 480 V No. 1 AC output 3 phase, 3 wire 480 V Fig.2 System confi guration of parallel redundant operation system (completely independent double bus system) model supports a parallel redundant operation system and a standby redundant operation system, which ensure continuous power supply during time of maintenance and equipment failure. The typical system configurations for each of these systems are shown in Fig. 2 and Fig. 3. 2.4 High performance and high functionality (1) Support for high power factor load In recent years, an improved power factor has been required by standards such as those enacted by the International Energy Star Program *1, and the number of electronic devices that adopt a PFC circuit for implementing power factor correction has been increasing. This product, therefore, supports to loads with a power factor of 1.0 (500 kw) in order to supply power to such equipment that uses the PFC circuit without reducing their power capacity. *1: The International Energy Star Program (Energy Star) is an international environmental labeling system for ensuring energy savings in electrical equipment. It is being managed under the mutual recognition of the Ministry of Economy, Trade and Industry in Japan and the United States Environmental Protection Agency. The program includes a wide range of products such as home appliances, industrial machines and computers. Fig.3 System confi guration of standby redundant operation system (2) Power walk-in function When the switches from battery based power supply (operation during power failure) to generator based power supply, the power walk-in function gradually changes the power sources. This function allows generators to prevent hunting and suppress voltage fluctuation due to sudden load changes. (3) Web/ SNMP card Connecting to a network via the Web/SNMP card, users can monitor the operating state of the from a standard web browser and receive failure information by email. Moreover, using dedicated monitoring software, they can also monitor output power trends and operating history and failure history of the. (4) MODBUS *2 card A newly developed option card supporting MODBUS makes it easy to monitor data by connecting to the networks of customer equipment. By selecting either the MODBUS card or Web/SNMP card, wide-scale compatibility can be achieved with the communication systems of customer equipment. *2: MODBUS is a trademark or registered trademark of Schneider Automation, Inc., France 18 FUJI ELECTRIC REVIEW vol.61 no.1 2015

3. Specifications Figure 4 shows the outer dimensions of the 7000HX-T3U, and Table 1 lists the specifications. By adopting a 3-level power conversion circuit, we have been able to decrease loss while also reducing the size Unit: mm (a) Front view 2,000 Intake Fig.4 Outer drawing of the 7000HX-T3U Discharges 1,900 900 Table 1 7000HX-T3U specifications (b) Side view Item Specification Feeding method Normal inverter feeding Rated output capacity 500 kva/500 kw Equipment max. efficiency 97% Power failure switching time Uninterrupted Mass 1,800 kg AC input Bypass input DC input AC output Number of phases 3 phase, 3 wire Voltage 480 V+10%, 20% Frequency 60 Hz±5% Power factor 0.99 (delay) to 1.0 Current harmonic distortion rate 3% or less Number of phases Voltage Nominal voltage 3 phase, 3 wire 480 V±10% 480 to 528 V (Equivalent to 240 to 264 lead-acid batteries) Number of phases 3 phase, 3 wire Voltage 480 V Frequency 60 Hz Load power factor 1.0 Voltage precision (at steady state) Within ±1% Transient voltage fluctuation ±3% or less (load 0 100%) Settling time 50 ms or less Voltage waveform distortion rate Frequency precision External synchronization range Overload capability 2% or less (ar load) 5% or less (non-ar load) Within ±0.01% (during internal oscillation) ±5% or less 125%: 10 min 150%: 1 min of the filter circuit. These enhancements have enabled us to achieve a reduced size and weight of equipment. 4. Circuit Configuration and Operation 4.1 Overview of main circuit configuration and operation Figure 5 shows the main circuit block diagram. This model adopts a double conversion system consisting of a rectifier to convert AC to DC and an inverter to convert DC to AC. A chopper is connected to the DC input to carry out charge/ discharge control of the storage battery. In the normal operating state, in which the AC input is within the normal range, stable power with a constant voltage and constant frequency is supplied to the load via the inverter. The rectifier carries out control so that the AC input current of the becomes a sine wave with a power factor approximately equal to 1, while the chopper charges the storage battery. If there is a power failure for the AC input, the chopper raises the voltage of the storage battery to an appropriate DC voltage, and the inverter supplies power after converting it to stable AC power. Figure 6 shows the waveform at power failure and power restoration. As a result, a continuous and stable output voltage can be supplied even during a power failure. In addition to the above mentioned operations, the chopper also performs discharge control in a mode that simultaneously supplies power to a load from both the input and the battery during overload, input voltage Bypass input AC input MCD DC input Storage battery Filter Rectifier Fig.5 Main circuit block diagram Output voltage 480 V Output current 601 A Input voltage 480 V MC1 Power failure AC switch MC4a MC4 Inverter Filter DC/DC Chopper Filter (100 ms/div) MC3 Fig.6 Waveform at power failure and restoration AC output Power restoration Load issue: Power Electronics Large-Capacity, High-Efficiency 3-Level for North America 7000HX-T3U 19

drop and restoration power walk-in. 4.2 Application of AT-NPC 3-level power conversion circuit The rectifier and inverter adopt an advanced T-type neutral-point-clamped (AT-NPC) 3-level power conversion circuit *3 as shown in Fig. 7. The semiconductor component used in the conversion circuit utilizes Fuji Electric developed AT-NPC 3-level insulated gate bipolar transistor (IBT) modules. The features of the AT-NPC 3-level power conversion circuit are indicated as follows: (a) Switching voltage is half that of a 2-level power conversion circuit, and as a result, it is possible to reduce the switching loss of the converter, improve power conversion efficiency, save energy and reduce the size of the converter. (b) Since the switching waveform is step-wise as shown in Fig. 8, it has reduced harmonic voltage compared with 2-level power conversion circuits. As a result, loss caused by filter circuit harmonics is reduced, and this reduces fixed loss (noload loss) and improves efficiency in the low load range while also making it possible to reduce the size of the reactor and capacitor. (c) Noise generated by switching can be reduced compared with 2-level power conversion circuits. 4.3 Applicable to 480 V AC rating Since the rated voltage of this model is 480 V, it needs to output a voltage higher than the typical 415 V output by converters manufactured for the Japanese market. To achieve this, it is generally necessary to change the withstand voltage of the component used in the semiconductor power converter, but this model allows the use of the same component used in products manufactured for the Japanese market by adopting a trapezoidal wave modulation system as the control system (see Fig. 9). Trapezoidal wave modulation enables the output of a voltage that is higher than sine wave modulation even when the peak of the phase voltage and the sine wave are the same. Since the withstand voltage of the semiconductor component is determined by the phase voltage, the utilization of trapezoidal wave modulation makes it possible to obtain a high voltage even when using a component with a low withstand voltage. Furthermore, since DC voltage is low, the switching loss of the semiconductor can also be reduced. 4.4 Efficiency and loss The efficiency characteristics during AC-AC op- U phase V phase W phase U phase V phase W phase Phase voltage Phase voltage P T3 T1 U-V V-W W-U U-V V-W W-U U M T4 V Line voltage Line voltage W (a) Trapezoidal wave modulation (b) Sine wave modulation N T2 Fig.9 Voltage waveform of rectifier and inverter Fig.7 AT-NPC 3-level power conversion circuit (a) 3-level power conversion system Fig.8 Comparison of switching waveforms (b) 2-level power conversion system *3: For more details on the 3-level power conversion circuit, refer to 3-Level Power Conversion on page71 [Supplemental explanation 6]. Efficiency (%) 100 99 98 97 96 95 94 93 92 91 90 0 10 20 30 40 50 60 70 80 90 100 Load factor (%) Fig.10 Effi ciency characteristics during AC-AC operation 20 FUJI ELECTRIC REVIEW vol.61 no.1 2015

eration for this model are shown in Fig. 10. When the load factor is between 20% and 100%, maximum efficiency is above 97% and minimum efficiency is above 95%. In other words, efficiency is high even when the actual operation load is low, and this, in turn, produces high energy savings. 5. Postscript In this paper, we introduced the 7000HX-T3U AT-NPC 3-level large-capacity, high-efficiency for the North American market. The model is compliant with North American standards and various power management systems, and it can be expected to be adopted for a wide range of power supply applications that require safety, high reliability and a low environmental burden. We will continue pursuing energy savings and globally-compliant features for our power supply products so that we can meet the expectations of our customers. issue: Power Electronics Large-Capacity, High-Efficiency 3-Level for North America 7000HX-T3U 21

*