Imaging Fourier transform spectrometer

Similar documents
The FTNIR Myths... Misinformation or Truth

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

Supplementary Materials

Historical radiometric calibration of Landsat 5

WIDE SPECTRAL RANGE IMAGING INTERFEROMETER

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Observational Astronomy

Spatial-Phase-Shift Imaging Interferometry Using Spectrally Modulated White Light Source

Chapter 7. Optical Measurement and Interferometry

1.6 Beam Wander vs. Image Jitter

Texture characterization in DIRSIG

Experimental study of colorant scattering properties when printed on transparent media

Automatic optical matched filtering an evaluation of Reflexite and Transitions lenses in an optical matched filtering role

Dario Cabib, Amir Gil, Moshe Lavi. Edinburgh April 11, 2011

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Basics of INTERFEROMETRY

Use of Computer Generated Holograms for Testing Aspheric Optics

Sub-nanometer Interferometry Aspheric Mirror Fabrication

Exercise 8: Interference and diffraction

Video Microscopy of Selective Laser Sintering. Abstract

Optical Characterization and Defect Inspection for 3D Stacked IC Technology

PhysicsAndMathsTutor.com 1

NIR SPECTROSCOPY Instruments

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

S.R.Taplin, A. Gh.Podoleanu, D.J.Webb, D.A.Jackson AB STRACT. Keywords: fibre optic sensors, white light, channeled spectra, ccd, signal processing.

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Noise reduction in digital images

DESIGNING AND IMPLEMENTING AN ADAPTIVE OPTICS SYSTEM FOR THE UH HOKU KE`A OBSERVATORY ABSTRACT

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Processing data from the SPIRE imaging Fourier transform spectrometer

Testing Aspherics Using Two-Wavelength Holography

3.0 Alignment Equipment and Diagnostic Tools:

Frequency-stepping interferometry for accurate metrology of rough components and assemblies

Interference [Hecht Ch. 9]

A MEMS Based Visible-NIR Fourier Transform Microspectrometer

Single Photon Interference Katelynn Sharma and Garrett West University of Rochester, Institute of Optics, 275 Hutchison Rd. Rochester, NY 14627

Why is There a Black Dot when Defocus = 1λ?

Department of Mechanical and Aerospace Engineering, Princeton University Department of Astrophysical Sciences, Princeton University ABSTRACT

Instructions for the Experiment

Be aware that there is no universal notation for the various quantities.

Chapter 25. Optical Instruments

PHYS 3153 Methods of Experimental Physics II O2. Applications of Interferometry

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

2 CYCLICAL SHEARING INTERFEROMETER

Detection of Partially Coherent Optical Emission Sources

Integrated into Nanowire Waveguides

Collimation Tester Instructions

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

1 Introduction Installation... 4

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

A broadband achromatic metalens for focusing and imaging in the visible

06SurfaceQuality.nb Optics James C. Wyant (2012) 1

Basics of INTERFEROMETRY

Improving the Collection Efficiency of Raman Scattering

Computer Generated Holograms for Optical Testing

Infra Red Interferometers

CONFOCAL MICROSCOPE CM-1

Spotlight 150 and 200 FT-IR Microscopy Systems

Coherence radar - new modifications of white-light interferometry for large object shape acquisition

Copyright is owned by the Author of the thesis. Permission is given for a copy to be downloaded by an individual for the purpose of research and

Basic Operator Procedure Training NewView 6300 GROWING IN A SHRINKING WORLD

BiRT-2.0 Bi-directional Reflectance and Transmittance Distribution Function Measurement System

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Simple interferometric fringe stabilization by CCD-based feedback control

Dynamic Phase-Shifting Microscopy Tracks Living Cells

Week IX: INTERFEROMETER EXPERIMENTS

Section 1: SPECTRAL PRODUCTS

Test procedures Page: 1 of 5

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Moving from biomedical to industrial applications: OCT Enables Hi-Res ND Depth Analysis

Stressed plastics by polarization

A Quantix monochrome camera with a Kodak KAF6303E CCD 2-D array was. characterized so that it could be used as a component of a multi-channel visible

Multispectral Image Capturing System Based on a Micro Mirror Device with a Diffraction Grating

R I T. Title: Wyko RST Plus. Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 05/23/06 1 SCOPE 2 REFERENCE DOCUMENTS

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

GRENOUILLE.

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

of surface microstructure

Holography as a tool for advanced learning of optics and photonics

N.N.Soboleva, S.M.Kozel, G.R.Lockshin, MA. Entin, K.V. Galichsky, P.L. Lebedinsky, P.M. Zhdanovich. Moscow Institute ofphysics and Technology

LINEARPYROMETER LP4. Technical Documentation KE November TN

17. Atmospheres and Instruments

7 WAVEMETER PROJECT #6 MODEL OEK-100. Measure the Wavelength of An Unknown laser Using 633nm and 543 nm HeNe lasers

An Imaging White Light Velocimeter

MICHELSON INTERFEROMETER & FOURIER TRANSFORM SPECTROMETRY

Contouring aspheric surfaces using two-wavelength phase-shifting interferometry

Microscope anatomy, image formation and resolution

The Design, Fabrication, and Application of Diamond Machined Null Lenses for Testing Generalized Aspheric Surfaces

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Laser Telemetric System (Metrology)

Introduction to the operating principles of the HyperFine spectrometer

The following article is a translation of parts of the original publication of Karl-Ludwig Bath in the german astronomical magazine:

From Extended Light Source to Collimated Illumination

Modeling the MTF and noise characteristics of complex image formation systems

Single Photon Interference Laboratory

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Large Field of View, High Spatial Resolution, Surface Measurements

Optical Signal Processing

Transcription:

Rochester Institute of Technology RIT Scholar Works Theses Thesis/Dissertation Collections 2001 Imaging Fourier transform spectrometer Eric Sztanko Follow this and additional works at: http://scholarworks.rit.edu/theses Recommended Citation Sztanko, Eric, "Imaging Fourier transform spectrometer" (2001). Thesis. Rochester Institute of Technology. Accessed from This Thesis is brought to you for free and open access by the Thesis/Dissertation Collections at RIT Scholar Works. It has been accepted for inclusion in Theses by an authorized administrator of RIT Scholar Works. For more information, please contact ritscholarworks@rit.edu.

Imaging Fourier Transform Spectrometer Design, Construction, and Evaluation Final Report Eric Sztanko Chester F. Carlson Center for Imaging Science Rochester Institute of Technology May 2001 Table of Contents

Imaging Fourier Transform Spectrometer Eric Sztanko Table of Contents Abstract Copyright Acknowledgement Introduction Background Design & Methods Discussion Construction Experiment # 1 - Movement Experiment # 2 - Monochromatic Source Experiment # 3 - Mercury Lamp and White Light Problems Future Work Conclusions References Appendix Title Page

Imaging Fourier Transform Spectrometer Eric Sztanko Abstract There are many applications that require spectral information from either objects or scenes. This paper will describe the design, construction, and evaluation of an imaging Fourier transform spectrometer (FTS) that will gather such spectral information. The design of the spectrometer is based on that of a Michelson interferometer. Theory, limitations, alignment, and cost will all be considered in this work. Table of Contents Copyright

Copyright 2001 Center for Imaging Science Rochester Institute of Technology Rochester, NY 14623-5604 This work is copyrighted and may not be reproduced in whole or part without permission of the Center for Imaging Science at the Rochester Institute of Technology. This report is accepted in partial fulfillment of the requirements of the course SIMG 503 Senior Research. Title: Imaging Fourier Transform Spectrometer Author: Eric N. Sztanko Project Advisor: Dr. Roger Easton Jr. SIMG 503 Instructor: Dr. Anthony Vodacek Table of Contents Acknowledgements

Imaging Fourier Transform Spectrometer Eric Sztanko Acknowledgements I would first off like to thank Dr. Roger Easton Jr. for helping me throughout the entire span of this project and having the patience to work with me. I would also like to thank Dr. John Schott, Bryce Nordgren, and the Digital Imaging and Remote Sensing (DIRS) group at RIT for giving me the opportunity to work on this project. Table of Contents Introduction

Imaging Fourier Transform Spectrometer Eric Sztanko Introduction The ability to obtain spectral information from objects or scenes is very useful in various fields including remote sensing, chemistry, astronomy, and industrial quality control. The methods of Fourier transform spectroscopy (FTS) have been used for over thirty years. As resolution of optical positioning devices and computer processing speeds increase, so does the usefulness and importance of FTS. There are many different designs of spectrometers available, but I have chosen to base this project on the Michelson interferometer. Background www.chemistry.vt.edu Figure 1: Michelson Interferometer www.3dimagery.com Figure 2: Interference Pattern The Michelson interferometer (Fig. 1) is a simple design that creates interference patterns, also known as interferograms (Fig. 2), an image of the interference of light waves. The waves combine in phase in regions of constructive interference, and add out of phase where the interference is destructive. Displacement of the moving mirror changes the optical path difference (OPD), producing interference, thus changing the interferogram. The data set is collected by scanning the moving mirror and recording the interferogram at each position (response versus position). "The interferogram is not a direct display of the spectrum although it is uniquely related to the spectrum. Through harmonic analysis of the interferogram, it can be decomposed into its component frequencies, resulting in a display of the spectrum" (1). The collection of interferograms allows calculation of the spectrum of the source by computing the discrete Fourier transform (Fig. 3).

Figure 3: Theoretical spectral calculation of a monochromatic source with an infinite OPD General Experimental Design and Methods Figure 4 is the schematic for the planned spectrometer. The system is designed to have unit magnification so that the input and output image scales are equal. All equipment will be fixed on the optical table. The planar object or source is placed in front of a collimating lens so that the wavefronts from each point are planar when they enter the beamsplitter. Approximately 50% of the energy will pass through the beamsplitter to the moving mirror and the other 50% to the fixed mirror. The moving mirror is restricted to a linear translation of 20 mm, which produces an OPD of up to 40 mm. The motion of the mirror needs to be considered because its surface must always be orthogonal to the source. Also, enough time must elapse between steps to allow mirror vibration to settle. By collecting the data on both sides of the zero path difference (ZPD), it creates a "two-sided interferogram". Doing this removes the problem of finding the location of the ZPD exactly (a time consuming procedure). Data collection time will double, but "linear phase error in wave number can be exactly eliminated" (2) and signal noise will be reduced in the process. After the light beam reflects from both mirrors and are recombined by the beamsplitter, it will be refocused directly onto a monochrome CCD video camera. The interferogram is sampled for every step of the moving mirror. The collection of interferograms are processed by a discrete Fourier transformation, returning the spectrum of the object or source. The spectrum is calculated for every pixel of the CCD to produce an image spectrogram of the input.

Figure 4: Spectrometer Concept Initial runs of the experiment were conducted with monochromatic light and lamps with prominent spectral lines, which helped in calibrating the system. Tests using illuminated color transparencies will be used to test the alignment of the system. Alignment is an important issue in an imaging spectrometer; light emerging from each single point in the object plane must converge to a specific single point in the image plane. Artifacts due to sources other than alignment will also be studied during this experiment. Some of these may be related to sampling, the motion of the mirror, optical aberrations, and the beamsplitter, all of which will affect the performance of the system. The interferograms must be imaged at sufficiently small increments of translation to ensure that the sinusoidal variations in the interferogram are not aliased. Construction

Figure 5: Constructed Spectrometer Pictured above is the actual spectrometer that was constructed. It follows the same design as specified in the layout. The light source is a HeNe laser (l = 632.8 nm) which has been collimated through use of a 40x microscope objective and a 10 mm diameter pinhole. The beamsplitter then redirects approximately half of the light to fixed mirror and the other half to the moving mirror. The light is then recombined and passes through a neutral density filter and directly onto the CCD of the monochrome digital camera. Both the motion of the mirror and image capture are automated processes controlled by the computer. A linear stepper motor controlled by the computer is used for the moving mirror. An inexpensive means for generating these very small displacements (< 100 nm) was necessary. Most of these systems cost anywhere from $8,000 to well over $15,000, but this system was found for under $3,000. The system which was purchased from SD instruments included the motorized translation device (7600 - X) for $850 and the controller (MC2000) for $1975. The specifications of the system were pushing the upper limits of what was needed, but it was the only system which fit in the budget.

Figure 6: Image on the left taken by the monochrome digital camera After collimating the light, alignment of the system with the monochromatic source was the next step. This involved reflecting the light at each of the sources (beamsplitter and the mirrors) back towards the pinhole. The interference fringes could be viewed on a piece of paper at the location of the recording camera. Above is a picture of the observed fringe pattern as taken by the digital camera. At this point the system is still only a Michelson interferometer. Experiment #1 - Movement The first experiment was performed to make sure that the translation device worked properly and that a change in the interferogram could be seen. This was performed by simply taking an initial image of the interference pattern, then displacing the stepper motor approximately 100 nm and taking another image at the new location.

Figure 7: Interference patterns before (top) and after (bottom) OPD displacement. Pictured above are interference patterns from the HeNe Laser. The second picture was taken after the optical path difference was displaced by approximately 200nm (notice the shift between the two images). The results from performing this task were that tiny displacements could be achieved and that there was a detectable change between the two images. Experiment #2 - Monochromatic Source The second experiment involved turning the Michelson interferometer into a spectrometer. The digital camera was programmed using a module in V++ so that it would take and save an image at a specified interval. The stepper motor was programmed with MVP Demo 2001, a shareware program downloaded off the Internet. The program steps the motor 5 encoder units (approximately 25 nm ) per second. The128 images in the first set of data were taken at intervals of 2.5 seconds and the images were sized down to 21 pixels by 21 pixels for a faster transfer rate. The first five images from the data set are shown below.

Figure 8: The first five images of the data set. Using IDL, the fast Fourier transform was computed for two arbitrary pixel locations (0,0) and (10,10). The data is first plotted and then the FFT is computed and graphed.

Figure 9: Data and FFT from a HeNe Laser. Results from the first experiment were very reassuring. Spikes occurred at ± 21 and at 0, the DC component. By zooming in on the data it can be seen that 6 samples were taken per cycle, thus Dx = 105.5 nm. Error = 642.7-632.8 = 9.9 nm Relative Error = 1.6 % With only 128 samples we were able to calculate the wavelength as well as possible with this discrete system. The experiment was to be run again with 512 samples and a time interval of only 0.5 seconds. As can be seen below the price of decreasing the sampling interval came at the increase of noise. This is especially true for the first few samples where there seemed to be a problem with the stepper motor.

Figure 10: Data and FFT from a HeNe Laser. The largest spikes occurred at ± 32 with the DC component removed. By zooming in on the data it can be seen that 16 samples were taken per cycle, thus Dx = 39.55 nm. Error = 632.8-632.8 = 0 nm Relative Error = 0 % By decreasing the interval time much noise was added to the system. Even though there was no error, the added noise created additional spikes surrounding ± 32, unlike the first try (128 samples - 2.5 second interval) where there were only two prominent spikes. Experiment #3 - Mercury Lamp and White Light Source The third experiment involved using a mercury lamp (prominent spectral lines) and a white light source (tungsten filament) in place of the laser. In both cases, images were collected at 512 positions with a time interval of 0.5 seconds. Both sources were not collimated due to the lack of brightness that would result. The data (shown below) was not adequate to obtain results in either case. The data looks like noise and there was not a large enough range of digital count values.

Figure 11 (above): Data and FFT from a Mercury Lamp. Figure 12 (below): Data and FFT from a White Light Source.

As this was the first attempt for both sources, modifications will be attempted to make improvements. For example, collimation may need to be obtained and by using a longer integration time for the digital camera, the signal to noise ratio would be reduced. Discussion Problems The major problems with the data were due to limitations of the stepper motor and digital camera. The requirements of this task exceed those envisioned by the manufacturer, and may be resulting in unequal step sizes and irregular motion of the stage. A final problem with the stepper motor is that there is a slight drift. The drift can be avoided by taking data quickly because the observed drift was approximately 200 nm in 3-5 minutes and 400

nm in 15 minutes. The problem with the digital camera is the software used to control it. The V++ software has a limit of around 160 images it can save, even if memory is constantly cleared. The around this was to run the program four times taking 128 images each time. While the images were being taken I would move the files into four separate folders. Future Work Future work is already in progress. The next step is to obtain the spectra of the mercury lamp and white light source. After the spectra are obtained, the daunting task of creating an 2-D image spectrogram of an input image would be attempted. Here alignment, aberrations, and effects of the beamsplitter become much more of an issue. Other future work may involve a more detailed look at the optics involved and also creating an interactive GUI software program for analyzing data. Conclusion I designed it. I built it. I tested it. Like all technical devices, it needs to be tested some more. The primary purpose of this project was to build a spectrometer that works. This has been demonstrated with use of the HeNe laser with a fairly high degree of accuracy. In the case of taking 128 samples, there was only a 1.6 % relative error, and when 512 samples were taken, the correct wavelength was found. To build an inexpensive imaging Fourier transform spectrometer is no easy task. Further testing and analysis should be able to yield the spectra for any type of light source along with a 2-D image spectrogram. I have provided a tool that is functional, now it must be studied further. Table of Contents References

Imaging Fourier Transform Spectrometer Eric Sztanko References Note: Please use the back button to return to the previous page 1. 2. 3. 4. 5. 6. 7. 8. Mertz, Lawrence. Transformations in Optics. John Wiley and Sons. New York, NY. 1965. Bell, Robert J. Introductory Fourier Transform Spectroscopy. Academic Press. New York, NY. 1972. Albergotti, J.C. "Fourier Transform Spectroscopy Using a Michelson Interferometer." American Journal of Physics. Volume 40. Pages 1070-1073. August 1972. Berkey, Donald K. "An Undergraduate Experiment in Fourier-Transform Spectrometry." American Journal of Physics. Volume 40. Pages 267-270. February 1972. Biggs, P., et al. "A Low-cost Fourier Transform Spectrometer for the Visible and Near-Infrared Regions." Source Unknown. Johnston, Sean F. Fourier Transform Infrared. Ellis Horwood Limited. Chichester, England. 1991. Lanteigne, David J. "Imaging spectrometer based on white-light interferometry." SPIE. Volume 1772. Pages 369-373. 1992. Tittel, H.O., et al. "A Fourier Spectrometer For Visible Light." Infrared Physics. Volume 24. Pages 323-328. 1984. Table of Contents Appendix

Imaging Fourier Transform Spectrometer Eric Sztanko Appendix Note: Please use the back button to return to the previous page IDL FFT Code MVP Demo 2001 Code V++ Code Table of Contents