-Vivaldi. Innovative strip centre measurement in high temperature ranges

Similar documents
IMH2. Inductive strip centre sensing in the high temperature range. precise up to 1100 C maintenance-free

VKI3. Inductive strip edge position control for rolling mills. single-side robust maintenance-free

SMI. Strip Measurement Inductive. maintenance-free self regulating reliable

EMG SOLID Oil layer measurement. Two technologies from one source: Infrared spectroscopy Laser-induced fluorescence spectroscopy

hotcam Camber and position measurement at the hot strip reduced camber higher operational safety improved strip quality

EVK/EVM. Optical strip edge and centre guiding system. high-precision reliable easy to maintain

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Inductive Analog-Sensors

Flexibility and efficiency on high accuracy machining

Design and Development of Tapered Slot Vivaldi Antenna for Ultra Wideband Applications

PS 1000 X-Scan Tips & Tricks. Quick Guide

Technical Article. Inductive Versus Capacitive Position Sensors. C = A d

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

X-Shape Precise flatness measurement and control

WARP Terahertz systems. A new age of product measurement

Measuring Technology for Soft Magnetic Materials

Digimax 210. Programmable Thermostat. User Guide

Inductive Voltage Transformers. Types VEOT and VEOS

ProGap Microwave barrier

Laird Engineered Thermal Systems Application Note. Active Cooling of Optical Transceivers

COUPLED SECTORIAL LOOP ANTENNA (CSLA) FOR ULTRA-WIDEBAND APPLICATIONS *

Broadband Circular Polarized Antenna Loaded with AMC Structure

Making Industries Smarter

In-line measurements of rolling stock macro-geometry

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

2-channel speed sensor GEL 248 Compact sensor with HTL-/TTL-output signals

OMNI-DIRECTIONAL WIDEBAND ANTENNA MODEL EM GHz - 18 GHz

Quad-Band Circularly Polarized Patch Antenna for UWB/5G Applications

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

W7070A2000 ZAPP WIRELESS RECEIVER

Sensors & Applications Glass Industry. More Precision

A NOVEL ANALYSIS OF ULTRA-WIDEBAND PLANAR DIPOLE ARRAY ANTENNA

How to understand MAGNETEC s Datasheet

The producers of galvanised steel strip, like all areas

1) The diagrams in the section Assembly notes were provided by Rittal GmbH Co. KG, Herborn and by Invensys Systems GmbH EUROTHERM, Limburg/ Lahn.

Optimized for perfection.

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

MRI SYSTEM COMPONENTS Module One

BATAILG TAIL GAS ANALYZER. Rev. 1.1

Design Study. Reducing Core Volume in Matrix Transformers

Wind Transmitter First Class

PLANT DESIGN RUNNING IN OUR VEINS The architect of your visions

Design of Rectangular-Cut Circular Disc UWB Antenna with Band-Notched Characteristics

SodiumStar 20/2 High Power cw Tunable Guide Star Laser

EMC filters. Mounting instructions. Date: January 2006

Electronic Circuit Breaker ESS20-0..

Wind Transmitter First Class / 141 / / 141 / 161

DIELECTRIC HEATING IN INSULATING MATERIALS AT HIGH DC AND AC VOLTAGES SUPERIMPOSED BY HIGH FREQUENCY HIGH VOLTAGES

Who We Are. Antennas Space Terahertz

Revolutionizing 2D measurement. Maximizing longevity. Challenging expectations. R2100 Multi-Ray LED Scanner

Signal converter for electromagnetic flowmeters

Bandwidth of Planar Antennas for UWB (6GHz - 8,5GHz)

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

PHOENIX CONTACT

RCS Reduction of Patch Array Antenna by Complementary Split-Ring Resonators Structure

Chapter 2. Literature Review

EC6011-ELECTROMAGNETICINTERFERENCEANDCOMPATIBILITY

Bandwidth Enhancement of a Microstrip Line-Fed Rotated Slot Antenna with a Parasitic Center Patch

JTR Guided Wave Radar Level Transmitter.

(TE) Dielectric Resonators & Materials

Methods for Evaluating the Shielding Effectiveness of Textiles

Types MCM and MIN SMT Clad RF Capacitors

TechNote. T001 // Precise non-contact displacement sensors. Introduction

Non-Contact AC Voltage Probe SP3000, AC Voltage Probe SP9001

Sensor and Simulation Notes. Note 505. December Development of the Impulse Slot Antenna (ISA) and Related Designs

Repeatability. ± 0.2 µm ( '') Centrally focused / 639 nm / <1 mw. Temperature range 10 C - 50 C

Zettlex. Precision in the Extreme

Humidity Temperature Sensor TFG80 Duct version with Polyga measuring element

Use of fibre sensors for temperature measurement in subsea infrastructure to monitor flow-loop cooldown

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

DESIGNING A PATCH ANTENNA FOR DOPPLER SYSTEMS

6 Electromagnetic Field Distribution Measurements using an Optically Scanning Probe System

L-BAND COPLANAR SLOT LOOP ANTENNA FOR INET APPLICATIONS

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

Power Commander. Power Commander Plus. Electronic Line Voltage Regulators. 15 kva 150 kva SINGLE PHASE 15 kva 450 kva THREE PHASE SERIES 900

1SC0450V2Ax-45 and 1SC0450V2Ax-65 Target Datasheet

A Printed Vivaldi Antenna with Improved Radiation Patterns by Using Two Pairs of Eye-Shaped Slots for UWB Applications

Electronic Circuit Breaker with reset input ESS20-1..

PERFORMANCE STUDIES OF RADIAL LINE SLOT ARRAY (RLSA) ANTENNA AT 5.8 GHz ON DIFFERENT MATERIALS Omar Abdul Aziz Tharek Abdul Rahman

Parametric Analysis of Multiple U Slot Microstrip Patch Antenna for Wireless Applications

Aboveground Monitoring - Casings Long Range Electromagnetic Wave (EMW) Inspection

TECHNICAL REPORT: CVEL Parasitic Inductance Cancellation for Filtering to Chassis Ground Using Surface Mount Capacitors

Solution of EMI Problems from Operation of Variable-Frequency Drives

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Feasibility Study on OFDM Signal Transmission with UWB 2D Communication Tile

Checklist for electromechanical and electronic active energy meters in accordance with the MID Directive (2004/22/EC)

Setting up High Gain Detector Electronics for TCSPC

R. Zhang, G. Fu, Z.-Y. Zhang, and Q.-X. Wang Key Laboratory of Antennas and Microwave Technology Xidian University, Xi an, Shaanxi , China

Small Planar Antenna for WLAN Applications

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

SATELLITE RECEIVING SYSTEM (IF)

Capacitive voltage transformers

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

Planar Radiators 1.1 INTRODUCTION

VSD cables in. Working with. industrial & automation applications

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Combined Instrument Transformers. Types IVOKT and TMC

Design of UWB Monopole Antenna for Oil Pipeline Imaging

Measurement technology for inline quality inspection in plastics production. More Precision

Transcription:

-Vivaldi Innovative strip centre measurement in high temperature ranges measuring through gas-tight furnace wall higher accuracy and operating security maintenance-free / no installations inside the furnace

EMG-Vivaldi measuring through gas-tight fu Challenges and operating principle: Determining the strip centre position is the most important goal for all strip guiding solutions. Traditionally, this is achieved via optical, capacitive, or inductive sensors. A particular challenge is to measure the strip centre in extreme environments, such as in annealing furnaces. EMG has many years of experience with inductive strip centre measuring systems in furnaces with temperatures of up to 1100 C. Nevertheless there has been the request, however, to determine the strip centre position in furnaces without having any active or interfering sensor elements inside the furnace itself. This is reminiscent of the childhood dream of being able to see through walls! This dream has finally become a reality thanks to EMG- Vivaldi ; the limits of inductive sensor technology now belong to the past! The EMG-Vivaldi sensor is located outside the furnace and conducts its measurements through the gas-tight enclosed furnace wall. The sensor system, which is mounted externally on the furnace wall, focuses electromagnetic waves onto the edge of thin metal strips through the non-conductive insulation of the furnace. As a result, cooling systems for the sensors within the furnace are no longer required. As the furnace wall is completely enclosed, the strip is not able to damage the sensor itself. The system is calibrated via simple reference measurements. The EMG-Vivaldi technology can replace other systems. Functional principle of EMG-Vivaldi Exterior view of the EMG-Vivaldi sensor EMG Automation GmbH specialises in the automation of continuous production processes in the metal, paper and plastics industries as well as in the foil and tyre industries. The company, which was established in 1946, is a leading provider of electro hydraulic control systems. Furthermore, EMG provides quality assurance systems for the manufacturing industry. Based on the combination of more than 60 years of experience, the quality of our products and complete solutions as well as our advisory skills, our customer, by his trust, makes us the market leader. By working in close co-operation with our customers, research facilities and universities we are continuously searching for innovative solutions to promote our new and enhanced products and therefore to actively shape the market as a leader in innovation. Features of EMG-Vivaldi : the measurement is performed through the furnace insulation and through an enclosed, gas-tight plate on the furnace wall only one sensor type for all kinds of strips (sensor is independent of strip width, temperature and material grade) no special cooling is required for temperatures up to +70 C on the outer furnace wall and for ambient temperatures up to +50 C (air or water cooling is optionally available for higher temperatures) low space requirement outside the furnace

rnace wall higher accuracy and operating security The Vivaldi technology: In contrast to other radar-based measuring systems, EMG- Vivaldi relies on the principle of so-called Vivaldi antennas. The EMG-Vivaldi system consists of two pairs of antennas, each of which is positioned on one side wall of the furnace. One antenna serves as a transmitter, while the other functions as a receiver in this setup. The antennas transmit and receive linearly polarised electromagnetic waves (EMW). These waves are reflected by the strip edge and transmit the edge position by means of an optimized digital runtime measurement. Evaluation of the data, and thus the determination of the strip centre position, is conducted within the control cabinet via an RPU (Radar Processing Unit) and an IPC. The furnace wall is covered in a non-metallic insulating material, which exhibits a low absorption rate of electromagnetic waves in the Vivaldi frequency range of 0.8 to 4 GHz. No sensor element extends into the interior of the furnace and both the electronics and the antennas on the outside of the furnace wall can be cooled with air (or water) if required. Only the radar windows (metal flanges with a special cover that are penetrated by the electromagnetic wave) are installed in the furnace wall with a particularly high quality, thermal heat insulation. An additional advantage is that the actual sensor can be removed from the furnace without having to open the furnace itself, which enables the furnace wall to retain its gas-tight seal. This feature significantly simplifies the process of replacing an antenna or the sensor electronics, as the furnace does not have to be cooled down beforehand. An unforeseen strip crack cannot damage the sensor therefore additional strip deflectors in the furnace are not necessary. Electronics and connection Copper layer on both sides Vivaldi antenna structure Interior view of the EMG-Vivaldi sensor housing Features of Vivaldi antennas: Ultra-wideband slot antenna (UWB) or Vivaldi antenna transmits and receives a linearly polarized electromagnetic wave co-planar parallel structure on a double-sided metallized dielectric substrate operating frequency 0.8 4 GHz enables measurement through the insulation material large electromagnetic range and thus stable measuring signals as well as higher measuring resolution simple electrical connection simple replacement of the antennas in the housing Customer benefits: no sensor parts inside the furnace measurement from outside through the furnace wall, which consists of furnace insulation and enclosed gas-tight plate no direct contact between the antenna housing and the interior of the furnace no installation in the furnace necessary no deformation of the antennas possible no damage to the sensor caused by the strip possible no contamination of the furnace interior or the antenna housing no cleaning of the antennas necessary

maintenance-free / no installations inside the furnace Customer benefits (continuance): no need for cooling systems for sensors inside the furnace the antennas or sensor electronics can be replaced without stopping the line low total costs of ownership (TCO) calibration via simple reference measurements only one type of sensor for all kinds of strips (sensor is independent of the strip width, temperature and material grade) EMG-Vivaldi can replace other systems particularly high quality, thermal furnace wall insulation on the sensor Particularly high quality thermal furnace wall insulation Schematic view of the required clearances to metallic parts inside the furnace Technical data: Strip thickness Strip temperature Strip position sample rate Centre position accuracy Cooling Installation position Sensor cable min. 0.1 mm independent 50 Hz / 20 ms up to ± 1 mm no cooling is required for temperatures up to +70 C on the outer furnace wall and for ambient temperatures up to +50 C (optional air or water cooling) observe the required clearances to metallic parts in the furnace; the exact dimensions depend on the individual line conditions (especially furnace width and minimum strip width) fibre optic cable (max. 30 m) between antenna boxes and control cabinet

System architecture: The sensor electronics and the antennas on the outside of the furnace wall can be cooled with air or water if required. They are connected to the control cabinet via fibre optics, which exhibit a maximum length of 30 m. The other electronics, which provide the control signals for the electric servo cylinder (ESZ) to regulate the guiding frame, are accommodated in the conditioned control cabinet.

Automation GmbH Industriestraße 1 57482 Wenden Germany Phone: +49 2762 612-0 Fax: +49 2762 612-384 automation@emg-automation.com www.emg-automation.com Group.moving ahead. EMG / P-A / EMG-Vivaldi / EN / Revision 01 / 12.2014 / Printed in Germany / Subject to modification