MY-GS CSM_MY-GS_DS_E_2_1

Similar documents
MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

CSM_G7S-_-E_DS_E_7_1

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

E3X-DRT21/SRT21/CIF11

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Alternate Operation Relay 61F-AN/-APN2

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Model Number Structure

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

E6F-CWZ5C (1000P/R) 2M

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

SPST-NO SPDT DPST-NO DPDT

Model Number Structure

Fluoro plastic housing for highest chemical and detergent resistance

Model Number Structure

Relays with Forcibly Guided Contacts G7SA

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Phase-sequence Phase-loss Relay

Switch Mode Power Supply

Classification Enclosure rating Contact form Contact material

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

General-purpose Relay

Switch Mode Power Supply

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

OMRON MK-I / -S RELAY

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

E8EB-N0C2B E8EB-N0B2B

SPST-NO SPDT DPST-NO DPDT

E6B2-C. General-purpose Encoder with External Diameter of 40 mm. Incremental 40-mm-dia. Rotary Encoder. Ordering Information

Phase-sequence Phase-loss Relay

Model Number Structure

Model Number Structure

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Details on the New G2RS

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Model Number Structure

Safety Monitoring Relays

Model Number Structure

Ordering Information. Ratchet Relay G4Q. Model Number Legend

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Contact Ag + Au-clad AgPd + Au-clad. General purpose DPDT G6AU-274P-ST-US G6AU-234P-ST-US 4PDT G6AU-474P-ST-US G6AU-434P-ST-US

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Single-phase Current Relay

For Momentary Operation

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

General-purpose Relay

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Single-phase Voltage Relay

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

20 Series Power Relays

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Sensing method Sensing distance Model

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Technical Information General Purpose Relays. Glossary. Maximum switching power [W(VA)] Switching current (A) Switching voltage (V) Contact Symbols

Model Number Structure

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN

RU Series Universal Relays

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

Single-phase Current Relay

General-purpose Relay

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Transcription:

Miniature Power Relays CSM DS_E 1 Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays Reduces wiring work by % when combined with the PYF-PU Push-In Plus Socket (according to actual OMRON measurements). Relays with AC and DC coils have different colors of operating indicators (LEDs). Printing on the coil tape indicates the operating coil specification. Mechanical operation indicators are a standard feature on all models. RoHS complaint. UL, CSA, and IEC (VDE certification). Refer to the Common Relay Precautions. Features Mechanical indicators are a standard feature on all models so that you can easily check the contact status. The color of the LED shows whether the coil voltage is AC or DC. Mechanical indicators (one on left and one on right) Contacts ON (coil energized) Contacts OFF (coil de-energized) LED operation indicator Relay with AC coil: Red Relay with DC coil: Green Model Number Structure Model Number Legend MY - -GS DC 1 3 1. Number of Poles : poles : poles. LED Operation Indicator Blank: Built-in mechanical indicators N: LED operation indicator and built-in mechanical indicators 3. Coil Surge Absorption Blank: Standard models D: Models with built-in diodes CR: Models with built-in CR circuits. Operating Coil Voltage Display Example: DC Relay with AC Coil (LED: Red) Relay with AC Coil (LED: Red) Relay with DC Coil (LED: Green) 1

Ordering Information List of Models Category Standard models Models with built-in operation indicators Models with built-in diodes and operation indicators Models with built-in CR circuits and operation indicators Contact configuration DPDT PDT DPDT PDT DPDT PDT DPDT PDT Model MY-GS MYN-GS MYN-GS MYN-D-GS MYN-D-GS MYN-CR-GS MYN-CR-GS Rated voltage (V) 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, 0 VDC 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, 0 VDC 1 VDC, VDC, 8 VDC, /1 VDC, 0 VDC /1 VAC, 1/10 VAC, 00/0 VAC, 0/0 VAC Accessories (Order Separately) Connection Sockets and Hold-down Clips Front-mounting Sockets Back-mounting Sockets Mounting DIN Track or screw mounting PCB mounting Wiring Screw connections Push-In Plus terminal blocks Soldered connections PYF08A-E PYF08A-N PYF-08-PU PY08-0 MY-GS MYN-GS PYF1A-E PYF1A-N PYF-1-PU PY1-0 MYN-GS Hold-down Clips PYC-A1 Socket combination PYC-P

Ratings and Specifications Ratings Operating Coil Item Rated current (ma) Coil resistance Rated voltage 0 Hz Hz (Ω) AC DC 0 3.6,39 36.3.9 Approx. 0.8 Note: 1. The rated current and coil resistance are measured at a coil temperature of 3 C with tolerances of +1%/ 0% for the AC rated current and +1% for the DC coil resistance.. The AC coil resistance and inductance values are reference values only (at Hz). 3. Operating characteristics were measured at a coil temperature of 3 C.. The values in parentheses for the rated currents and coil voltages of DC coils are for models with LED operation indicators.. The maximum voltage capacity was measured at an ambient temperature of 3 C. *1. There is variation between products, but actual values are % max. The Relay will operate if % or higher of the rated voltage is applied. However, to achieve the specified characteristics, apply the rated voltage to the coil. *. There is variation between products, but actual values are 30% minimum for AC and % minimum for DC. To ensure release, use a value that is lower than the specified value. Contacts Coil inductance (H) Armature OFF 1 6. 91 6 0.17 0.33 3.8 6 1 0.69 1.3 8.7 1.1 788 3..66 /1 11.7/1.9.0/11.0 3,70 1..6 1/10 9.9/.8 8./9.,30 19. 3.1 00/0 6./6.8.3/.8 1,90.7 9.07 0/0./6..3/.0 1,90 83. 136. 6 16 (11) 1.0 (39.8) 0.17 0.33 1 7.7 (7) 16 (1) 0.73 1.37 36.3 (37.7) 66 (636) 3..7 8 17.6 (18.8),7 (,).6 1.0 /1 8.7 (9.0)/9.6 (9.9) 11,0 (11,).6 86. Armature ON Must-operate voltage % max. *1 Must-release voltage Percentage of rated voltage 30% min. * % min. * Maximum voltage Power consumption (VA, W) Minimum load 1 ma at VDC (reference values)* * These values are guides for the switchable limits for minute load levels, such as in electronic circuits. Actual characteristics may be different. These values will depend on the switching frequency, atmosphere, and expected reliability level. Confirm applicability in the actual system under actual application conditions. 1% poles poles Resistive load Inductive load (cos φ = 0., L/R = 7 ms) Resistive load Contact configuration DPDT PDT Contact structure Single Contact material Ag Rated load A at 0 VAC A at VDC A at 0 VAC A at VDC 3 A at 0 VAC 3 A at VDC Rated carry current A 3 A Maximum contact voltage 0 VAC, 0 VDC 0 VAC, 0 VDC Maximum contact current A 3 A Maximum switching capacity 1, VA 10 W 0 VA 8 W 6 VA 7 W Approx. 0.9 to 1.3 (at Hz) Approx. 0.9 Inductive load (cos φ = 0., L/R = 7 ms) 0.8 A at 0 VAC 1. A at VDC 176 VA 36 W 3

Characteristics Contact resistance *1 Operation time * Release time * Maximum Mechanical operating frequency Rated load Insulation resistance *3 Between coil and contacts Dielectric strength Vibration resistance Between contacts of different polarity Between contacts of the same polarity Destruction Malfunction Weight Approx. 3 g Note: The above values are initial values. *1. Measurement conditions: 1 A at VDC using the voltage drop method. *. Measurement conditions: With rated operating power applied, not including contact bounce time. *3. Measurement conditions: For 00 VDC applied to the same location as for dielectric strength measurement. *. Ambient temperature condition: 3 C Duty ratio: 33% Certified Ratings for Models Certified for Safety Standards The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. UL-certified Models: UL08 mω max. 0 ms max. 0 ms max. 18, 000 operations/h,00 operations/h 1,000 MΩ min.,000 VAC at 0/ Hz for 1 min.,000 VAC at 0/ Hz for 1 min. 1,000 VAC at 0/ Hz for 1 min. poles poles to to Hz, Double amplitude: 1.0 mm to to Hz, Double amplitude: 1.0 mm Shock resistance Destruction 1,000 m/s (approx. G) Malfunction 00 m/s (Approx. 0 G) Mechanical 0,000,000 operations (switching frequency: 18,000 operations/h) Endurance Electrical * 00,000 operations (switching frequency:,00 operations/h) 00,000 operations (switching frequency:,00 operations/h) Ambient operating temperature Standard models: to 70 C (with no icing or condensation) Models with LED operation indicators: 0 to 70 C (with no icing or condensation) Ambient humidity % to 8% Number of poles Coil ratings Contact ratings Certified number of operations 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, or 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, or 0 VDC A, 30 VDC (General Use) A, 0 VAC (General Use) 6,000 operations 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, or 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, or 0 VDC 3 A, 30 VDC (General Use) 3 A, 0 VAC (General Use) 6,000 operations CSA-certified Models: CSA C. No.1 Number of poles Coil ratings Contact ratings Certified number of operations 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, or 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, or 0 VDC A, 30 VDC (General Use) A, 0 VAC (General Use) 6,000 operations 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, or 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, or 0 VDC 3 A, 30 VDC (General Use) 3 A, 0 VAC (General Use) 6,000 operations VDE-certified Models: EN 618-1 Number of poles Coil ratings Contact ratings Certified number of operations 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, or 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, or 0 VDC A, 30 VDC (L/R = 1) A, 0 VAC (cosφ = 1),000 operations 1 VAC, VAC, 8 VAC, /1 VAC, 1/10 VAC, 00/0 VAC, or 0/0 VAC 6 VDC, 1 VDC, VDC, 8 VDC, /1 VDC, or 0 VDC 3 A, 30 VDC (L/R = 1) 3 A, 0 VAC (cosφ = 1),000 operations

Engineering Data Reference Data Maximum Switching Capacity MY-GS Contact current (A) DC resistive load 1 AC resistive load AC inductive load cosø = 0. Contact current (A) 1 AC resistive load AC inductive load cosø = 0. 0. DC inductive load L/R = 7 ms 0. DC resistive load 0.1 0.1 DC inductive load L/R = 7 ms 0 00 0 00 Contact voltage (V) Contact voltage (V) Endurance Curve MY-GS (Resistive Load) MY-GS (Inductive Load) Number of operations ( 3 operations),000 1,000 VDC resistive load 0 VAC resistive load Number of operations ( 3 operations),000 1,000 VDC inductive load 0 VAC inductive load 0 1 3 Contact current (A) (Resistive Load) 0 0. 1 1. Contact current (A) (Inductive Load) Number of operations ( 3 operations),000 1,000 VDC resistive load 0 VAC resistive load Number of operations ( 3 operations),000 1,000 0 VAC inductive load VDC inductive load 0 0. 1 1.. 3 Contact current (A) Note: 1. Number of operations: AC load, 0 Hz, %. Switching condition: NO or NC 0 0. 1 1. Contact current (A)

Ambient Temperature vs. Must-operate and Must-release Voltage MY-GS AC Models MY-GS Must-operate/must-release voltage (%) 0 Number of Relays: (average value) Must-operate voltage Must-release voltage Must-operate/must-release voltage (%) 0 Number of Relays: (average value) Must-operate voltage Must-release voltage 0 0 0 30 0 30 90 AC Models Must-operate/must-release voltage (%) 0 0 Number of Relays: (average value) Must-operate voltage Must-release voltage 0 30 0 30 90 Must-operate/must-release voltage (%) 0 0 Number of Relays: (average value) Must-operate voltage Must-release voltage 0 30 0 30 90 Ambient Temperature vs. Coil Temperature Rise MY-GS AC Models, 0 Hz Temperature rise ( C) 10 1 90 70 A contact current circuits. A contact current 0 circuits 0 30 No contact current 0 When rated voltage is applied Limit to operating temperature (E-class insulation (10 C)) 0 0 30 0 0 70 AC Models, 0 Hz Temperature rise ( C) 10 1 90 70 0 0 30 0 3 A contact current circuits No contact current When rated voltage is applied Limit to operating temperature E-class insulation (10 C) 1. A contact current circuits 0 30 0 30 90 MY-GS Temperature rise ( C) 10 1 90 70 0 0 30 0 A contact current circuits No contact current 0 0 30 0 0 70 Temperature rise ( C) 10 1 90 0 When rated voltage is applied Limit to operating temperature (E-class insulation (10 C)). A contact current circuits When rated voltage is applied 70 0 3 A contact current circuits 0 1. A contact current circuits 30 No contact current Limit to operating temperature (E-class insulation (10 C)) 0 0 30 0 0 70 0 0 30 0 0 70 6

Dimensions Relays (Unit: mm) MY-GS and MYN-GS.6 Eight, 1.-dia.. oval holes 0. 8 max. MY-GS MYN-GS MYN-D-GS MYN-CR-GS Standard Models 36 max. 6. AC Models 1. max. Internal Connections (Bottom View) (except 0 VDC) (for 0 VDC) (except 0 VDC) (for 0 VDC) AC Models (The coil has no polarity.) (The coil has no polarity.) Note: 1. An AC model has coil disconnection self-diagnosis.. For the DC models, check the coil polarity 3. The indicator is red for AC and green for DC.. The LED operation indicators indicate the energization of the coil and do not necessarily represent contact operation. (The coil has no polarity.) and MYN-GS.6 Fourteen, 1.-dia.. oval holes 0. 8 max. 36 max. 6. 1. max. Internal Connections(Bottom View) MYN-GS MYN-D-GS MYN-CR-GS Standard Models AC Models (except 0 VDC) (for 0 VDC) (except 0 VDC) (for 0 VDC) AC Models (The coil has no polarity.) (The coil has no polarity.) (The coil has no polarity.) Note: 1. An AC model has coil disconnection self-diagnosis.. For the DC models, check the coil polarity 3. The indicator is red for AC and green for DC.. The LED operation indicators indicate the energization of the coil and do not necessarily represent contact operation. 7

Options (Order Separately) Refer to Common Socket and DIN Track Products for details on Connection Sockets and DIN Track products (sold separately). Refer to PYF-@@-PU/PRF-@@-PU for details on A Push-In Plus Terminal Block Socket. Connection Sockets Front-mounting Sockets PYF08A-E Two, mounting holes 6 +0. 0.1 3. 8-M3 8 Internal Connections (Top View) 8 1 Mounting Hole Dimensions (Top View) Two, M3, M or.-dia. holes 7 max. 3. 9±0.3 1 1 13 9 3 max. 6 16. 31 max. 1±0. Note: Mounts to DIN Track. PYF1A-E Two, mounting holes 6 +0. 0.1 1-M3 8 3. Internal Connections (Top View) 3 8 7 6 1 Mounting Hole Dimensions (Top View) Two, M3, M or.-dia. holes 7 max. 3. 1 11 1 13 9 9±0.3 9. max. 6 16. 31 max. ±0. Note: Mounts to DIN Track. PYF08A-N Internal Connections (Top View) Mounting Hole Dimensions (Top View) 8 1 1 1 67 max. 1 1 1 8 18.7 3-dia. hole M3 or 3.-dia. hole PYF-08A-N 73 1 11 1 9 A A A1 1 1 13 max. 30 max. 1 9 1 11 1 1 13 A A A1 Note: Mounts to DIN Track. PYF1A-N 3 3 1 1 Internal Connections (Top View) Mounting Hole Dimensions (Top View) 8 7 6 3 1 67 max. 3 1 3 1 3 1 8 7 6 Two, M or.-dia. holes PYF-1A-N 1 31 1 1 11 A A 1 1 11 9 A1 13 73 6 Note: Mounts to DIN Track. 9. max. 30 max. 1 11 9 1 31 1 11 1 1 13 A A A1 8

PYF-08-PU 71. max..1 Internal Connection Diagram (TOP VIEW) 30.8 8.1 7.6 67. (.) A1 (13) A (1) Mounting Hole Dimensions Two M screw holes or two -dia. holes 3. Release lever 90 max. 1 (1) () 1 () (8) 8 7. 11 1 (9) (1) 3.9 7.6 36.3 31 max. (.) Note: The numbers in parentheses are traditionally used terminal numbers. Note: Pull out the hooks to mount the Relay with screws. PYF-1-PU 71. max. Internal Connection Diagram (TOP VIEW).1 A1 (13) A (1) 30.8 8.1 7.6 67. (.) Mounting Hole Dimensions 3. Release lever 90 max. 1 3 (1) () (3) () 1 3 () (6) (7) (8) Two M screw holes or two -dia. holes 8 7. 11 1 31 1 (9) () (11) (1) 3.9 7.6 36.3 31 max. (.) Note: The numbers in Note: Pull out the hooks to mount parentheses are the Relay with screws. traditionally used terminal numbers. Back-mounting Sockets PY08-0 0.3 1.0 Internal Connections (Bottom View). max. 9. max. 1 PCB Processing Dimensions 13..7.3 16. max. max. 8 9 1 13 1.8 6..1 1.6 6.3. Eight, 1.3-dia. holes PY1-0 0.3 1.0. max. 9. max. Internal Connections (Bottom View) 1 3 PCB Processing Dimensions 13...7.3 16. max. max. 6 7 8 9 11 1 13 1.8 6..1 1.6 6.3. Fourteen, 1.3-dia. holes 9

Accessories Hold-down Clips Relay model Socket model PYC-A1 Set of clips PYF08A-E PYF1A-E PYF08A-N PYF1A-N PYC-P PY08-0 PY1-0 MY-GS MYN-GS MYN-GS max. 36.3 9 max. Approx. 3 38.. 1.. Mounting Heights with Sockets (Unit: mm) Front-mounting Sockets MY 70 66 PYF A-E PYF A-N Back-mounting Sockets MY 8 PY -0

Safety Precautions Refer to the Common Relay Precautions for precautions that apply to all Relays. Precautions for Correct Use Handling For models with built-in LED operation indicators, check the coil polarity (DC operation). Installation There is no specifically required installation orientation, but make sure that the Relays are installed so that the contacts are not subjected to vibration or shock in their movement direction. Using Relays with Microloads with Infrequent Operation If standard MYGS Relays are used to infrequently switch microloads, the contacts may become unstable and eventually result in poor contact. In this case, we recommend using the MYZ-CBG Series, which has high contact reliability for microloads Relay Replacement To replace the Relay, turn OFF the power supply to the load and Relay coil sides to prevent unintended operation and possible electrical shock. Applicable Sockets Use only combinations of OMRON Relays and Sockets. 11

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 016.7 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 016 All Right Reserved.