Note: 1. All the students must strictly follow all the safety precautions. 2. In case of any question or concern, please contact LAB INSTRUCTOR or TA.

Similar documents
UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE

ECE215 Lecture 7 Date:

ECE 2006 University of Minnesota Duluth Lab 11. AC Circuits

VOLTAGE AND CURRENT RELATIONS AND POWER PART1: THREE PHASE VOLTAGE AND CURRENT RELATIONSHIPS

The Two-Wattmeter Method

Three Phase Transformers

ME 269 Laboratory Session #5

PHY203: General Physics III Lab page 1 of 5 PCC-Cascade. Lab: AC Circuits

EE 448 Fall Lab Experiment No. 3 04/04/2008. Transformer Experiment

EELE 354 Lab Assignment 2: Electric Heater - Power Measurements and Considerations

10Vdc. Figure 1. Schematics for verifying Kirchhoff's Laws

ECE ECE285. Electric Circuit Analysis I. Spring Nathalia Peixoto. Rev.2.0: Rev Electric Circuits I

Chapter 30 Inductance, Electromagnetic. Copyright 2009 Pearson Education, Inc.

ELECTROMGNTIC ENGERY CONVERSION LABORATORY MANUAL EE Dr. Khosrow Rad. March 2017

+ 24V 3.3K - 1.5M. figure 01

Sirindhorn International Institute of Technology Thammasat University

Pre-Laboratory Assignment

VALLIAMMAI ENGINEERING COLLEGE

University of Jordan School of Engineering Electrical Engineering Department. EE 219 Electrical Circuits Lab

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK UNIT I BASIC CIRCUITS ANALYSIS PART A (2-MARKS)

ECE 215 Lecture 8 Date:

PH213 Chapter 26 solutions

Exercise 1: The DC Ammeter

Power Circuits and Transformers

ELECTRICAL POWER TRANSMISSION TRAINER

AC CIRCUITS. Part 1: Inductance of a Coil. THEORY: If the current in a resistor R, a capacitor C, and/or an inductor L is given by:

DC Circuits, Ohm's Law and Multimeters Physics 246

Equipment and materials to be checked out from stockroom: ECE 2210 kit, optional, if available. Analog BK precision multimeter or similar.

Fundamentals of Electric Circuits Chapter 2. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

EE 210: CIRCUITS AND DEVICES

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE

Experiment 2: Simulation of DC Resistive Circuits

Instrument Usage in Circuits Lab

SIR C R REDDY COLLEGE OF ENGINEERING EEE Department, ELURU.

EECS 100/43 Lab 1 Sources and Resistive Circuits

UNIVERSITY OF TECHNOLOGY, JAMAICA School of Engineering -

BEST BMET CBET STUDY GUIDE MODULE ONE

LVSIM-EMS Help Table of Contents

The Discussion of this exercise covers the following points: Phasor diagrams related to active and reactive power

Spring 2000 EE361: MIDTERM EXAM 1

Oregon State University Lab Session #1 (Week 3)

UNIVERSITY OF TECHNOLOGY, JAMAICA SCHOOL OF ENGENEERING. Electrical Engineering Science. Laboratory Manual

OHM'S LAW AND RESISTANCE NETWORKS OBJECT

RESISTANCE & OHM S LAW (PART I

EE 221 CIRCUITS II. Chapter 12 Three-Phase Circuit

DC CIRCUITS AND OHM'S LAW

Notes on Experiment #12

AC/DC ELECTRONICS LABORATORY

TITLE: Introduction to various Basic Instruments of Electrical Science

+ A Supply B. C Load D

PHYSICS - CLUTCH CH 29: ALTERNATING CURRENT.

V (in volts) = voltage applied to the circuit, I (in amperes) = current flowing in the circuit, R (in ohms) = resistance of the circuit.

Goals. Introduction. To understand the use of root mean square (rms) voltages and currents.

Module 1. Introduction. Version 2 EE IIT, Kharagpur

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

Goals. Introduction. To understand the use of root mean square (rms) voltages and currents.

Chapter 1: DC circuit basics

ELECTRIC CIRCUITS CMPE 253 DEPARTMENT OF COMPUTER ENGINEERING LABORATORY MANUAL ISHIK UNIVERSITY

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

Lab 3 DC CIRCUITS AND OHM'S LAW

Lab 1 - Intro to DC Circuits

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

Question Paper Profile

AME140 Lab #2 INTRODUCTION TO ELECTRONIC TEST EQUIPMENT AND BASIC ELECTRONICS MEASUREMENTS

Transformer & Induction M/C

Laboratory 2. Lab 2. Instrument Familiarization and Basic Electrical Relations. Required Components: 2 1k resistors 2 1M resistors 1 2k resistor

EET140/3 ELECTRIC CIRCUIT I

Chapter 1: DC circuit basics

CHAPTER 11. Balanced Three-Phase Circuits

Jawaharlal Nehru Engineering College, Aurangabad.

EXPERIMENT FREQUENCY RESPONSE OF AC CIRCUITS. Structure. 8.1 Introduction Objectives

BASIC ELECTRICAL AND INSTRUMENTATION DESIGN TRAINING SECTOR / ENGINEERING

The sum of the currents entering a circuit junction is equal to the sum of the currents leaving the junction.

ECE 53A: Fundamentals of Electrical Engineering I

Laboratory 2 (drawn from lab text by Alciatore)

Electrical Circuits I (ENGR 2405) Chapter 2 Ohm s Law, KCL, KVL, Resistors in Series/Parallel

University of Pennsylvania Department of Electrical and Systems Engineering. ESE 206: Electrical Circuits and Systems II - Lab

REQUIRED SKILLS AND KNOWLEDGE UEENEEE104A. Topic and Description NIDA Lesson CARD #

MCQ Questions. Elements of Electrical Engineering (EEE)

NODIA AND COMPANY. Model Test Paper - I GATE Electrical & Electronic Measurement. Copyright By Publishers

Code No: RR Set No. 1

EE 233 Circuit Theory Lab 4: Second-Order Filters

EK307 Passive Filters and Steady State Frequency Response

Basic Electrical Engineering

Group: Names: Resistor Band Colors Measured Value ( ) R 1 : 1k R 2 : 1k R 3 : 2k R 4 : 1M R 5 : 1M

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

Sample VA Electrical Technology Assessments

Module 7. Transformer. Version 2 EE IIT, Kharagpur

Electronics Review 1 Cornerstone Electronics Technology and Robotics II Week 1

DEPARTMENT OF ELECTRICAL ENGINEERING

Lab 1: Basic RL and RC DC Circuits

Electronic Instrument Disadvantage of moving coil meter Low input impedance High loading error for low-voltage range voltmeter

Physics for Scientists & Engineers 2 2 = 1 LC. Review ( ) Review (2) Review (3) e! Rt. cos "t + # ( ) q = q max. Spring Semester 2005 Lecture 30 U E

For the circuit in Fig. 1, determine the current in the neutral line.

1. THREE-PHASE TRANSFORMER. SHORT CIRCUIT TEST

AC Power Instructor Notes

Notes on Experiment #3

Figure 1(a) shows a complicated circuit with five batteries and ten resistors all in a box. The

Experiment No. Experiments for First Year Electrical Engg Lab

Transcription:

UNIVERSITY OF WATERLOO ELECTRICAL & COMPUTER ENGINEERING DEPARTMENT FALL 2006 E&CE 261: Energy Systems and Components EXPERIMENT 1: THREE-PHASE SYSTEMS Contents covered in this laboratory exercise: 1. Relationship between the line voltages and phase voltages for wye-delta connected complex load. 2. Relationship between the line currents and phase currents for wye-delta connected complex load. 3. Three phase power measurement for balanced and unbalanced loads 4. Three phase power measurement using two-wattmeter method 5. Three phase power measurement using three-wattmeter method Note: 1. All the students must strictly follow all the safety precautions. 2. In case of any question or concern, please contact LAB INSTRUCTOR or TA. Safety precautions: 1. Do not touch any exposed terminals when wall panel 3- Ø breaker is ON. 2. Do not change the connections or settings without informing the lab instructor or TA. Ensure the wall panel 3- Ø breaker is OFF while changing the connections. 3. Do not operate the wye-delta switch when load is applied. 4. Current should not exceed 5A with Y-connected load. 5. Observe the ammeter reading while operating the load switches. Definitions: 1. 3-Ø Three phase. 2. Y wye connected configuration. 3. delta connected configuration. 4. Source-load-interfacing-box It is a box used to facilitate (a) To configure the load either in Y or in and (b) To have a 3-Ø three wire or a 3-Ø four wire supply system. 5. Load bank Selectable resistive load consisting of light bulbs and resistive heating elements. 6. Capacitor bank Selectable capacitive load consisting of capacitors of different values. 7. Watt-meter It is an instrument used to measure real power by sensing current passing through the load and voltage applied across the load. 8. Balanced load All three phases have the same current by having the same load impedance per phase. 9. Unbalanced load All three phases have the different current by having the different load impedance per phase. 10. V ab, V bc, V ca Line voltages

- 2-11. V a, V b, V c Phase voltages 12. I 1, I 2, I 3 Line currents 13. I 5, I 6,I 7 Phase currents 14. Neutral switch the switch used in the neutral wire to select three wire or four wire supply. 15. Y- switch the switch used to select either Y or connected load.

- 3 - Watt-meter Tutorial The Watt-meter is an instrument used to measure the real power by sensing current passing through the load and voltage applied across the load. An analog watt-meter deflects according to the average value of the product of voltage and current. The formula for the real power is V X A = (Vrms ) * (Arms) cos(ø). Figure (a) shows the picture of watt-meter depicting the terminals, selectors and scales. Figure (a) shows the picture of watt-meter The current is sensed by a current coil; designated by A on the watt-meter. The voltage is sensed by a voltage coil; designated by V on the face of the watt-meter. There are two selector knobs; 1. Current selector - to select the current range depending on the current flowing through the circuit. 2. Voltage selector - to select the voltage range based on the voltage applied to the load. Do not make the wrong selection which may result in damaging the instrument. The meter display does not show actual power. The power is to be calculated based upon the reading. It can be calculated in two ways. Method#1: There will be multiple scales based on the voltage ranges. For example; if there are 120, 240 and 480 voltage selections, there will be three scales for each voltage selection. Take the reading from the appropriate scale and then multiply with the current range (selected by current selector) to get the power in watts.

- 4 - Power = Reading X Current range Example: Suppose the voltage selection is made 240 and Current selection is made 10. If the meter reading is 50 in 240-scale, then Power = 50X10 = 500 W. Method#2: Take the reading from smallest scale irrespective of the voltage selection and calculate the multiplication factor (MF) as follows. MF = (Voltage selection X Current selection) / Full scale deflection of the smallest scale. Power = Reading X MF. Example: Suppose the voltage selection is made 240 and Current selection is made 10. There are three scales 120-scale, 240-scale and 480-scale. If the meter reading is 25 in 120-scale MF = (240X10)/120 = 20, then Power = 25X20 = 500 W. Advantage; The second method has a better accuracy and reading can be taken easily. This method is also helpful, if there is only one scale on the meter with multiple voltage ranges. Figure (b) shows the connecting diagram of watt-meter in a simple circuit. Figure (b): watt-meter connections.

- 5 - Procedure: The 3-Ø source, source-load interfacing box, 3-Ø load bank and necessary instruments have been connected. Review the schematics to identify all the components connected in the lab set-up. Also identify the scales and multiplication factors of all the instruments. Record the switch configuration in the load mapping tables after applying the load in each case. 3-Ø Power measurement using Two-Wattmeter-Method Part 1: 3-Ø three wire supply system with a Y-connected load. 1.1 (a) A balanced resistive load. Refer to the circuit as shown in Figure #1 to understand the configuration. Select the neutral switch to the open position, select the Y- switch to the Y position on the source-load-interfacing-box and select the voltage coil of the watt-meters at 240 position. Connect a balanced resistive load. Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #1. Table #1: 3-Ø three wire supply system with a balanced Y-connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = Zero MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 I 7 = 6 7 1.1 (b) Report: Find out the relationship between the measured line and phase voltages. Compare to theoretical values. Find out the relationship between the measured line and phase currents. Compare to theoretical values. Calculate the total power dissipated in the Y connected resistors from the wattmeter measurements. Calculate the total power supplied to the Y connected load from the phase current and phase voltage measurements and power factor of each phase. Compare the two powers and comment on it.

- 6 - Draw the phasor diagram of the power system. Include the line voltages, the phase voltages and the line and phase currents. Indicate numerical values of all quantities. 1.2 (a) A balanced resistive and capacitive load. Connect a balanced RC load. Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #2. Table #2: 3-Ø three wire supply system with a balanced Y-connected Resistive and Capacitive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = Zero MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 I 7 = C = µf/ph 6 7 1.2 (b) Report: Define and calculate the system measured power factor. Draw the phasor diagram of the power system. Include the line voltages, the phase voltages and the line and phase currents. Indicate numerical values of all quantities.

- 7-1.3 (a) An unbalanced resistive load. Connect an unbalanced resistive load. Record the line-to-line voltages, the phase voltages, the line currents, phase currents, the neutral current and the total power supplied to the load in Table #3. Remove the load. Table #3: 3-Ø three wire supply system with an unbalanced Y-connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = Zero MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 I 7 = 6 1.3 (b) Report: Calculate the total power dissipated in the Y connected unbalanced resistors from the wattmeter measurements. Calculate the total power supplied to the Y connected load from the phase current and phase voltage measurements and power factor of each phase. Compare the two powers and comment on it. Would it be possible to determine the system power factor? Explain. Can one calculate the power supplied to an unbalanced Y connected resistive-inductive load from a measurement of line voltages and line currents in the case of a) a three wire system, b) a four wire system? Assume the power factor of each phase is known. Explain the answers. 7 What is the advantage of the system neutral wire connected to the common point of the Y-connected load?

- 8 - Part 2: 3-Ø three wire supply system with a - connected load. Refer to the circuit as shown in Figure #2 to understand the configuration. Select Y- switch to position and neutral switch to open position. Select the voltage range of the watt-meters at 240V position. (Note: There is a chance of exceeding the readings of A 1, A 2, and A 3. If it is so, remove the load using switches and turn-off the power using the 3- Ø circuit breaker and change the meter connections to the next higher current range for ammeters and select next higher current setting for watt-meters.) 2.1 (a) A balanced resistive load. Connect the same balanced resistive load as in Part 1.1 a). Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #4. Table #4: 3-Ø three wire supply system with a balanced -connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = Zero MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 2.1 (b) Report. I 7 = 6 Find out the relationship between the measured line and phase voltages. Compare to theoretical values. Find out the relationship between the measured line and phase currents. Compare to theoretical values. What is the difference between the relationship of voltages and currents compared to part1.1 (a)? Calculate the total power dissipated in the connected resistors from the wattmeter measurements. Calculate the total power supplied to the Y connected load from the phase current and the phase voltage measurements and the power factor of each phase. Compare the two powers and comment on it. What is the difference in the powers in part1.1 (a) and part 2.1 (a). Comment. Draw the phasor diagram of the power system. Include the line voltages, the phase voltages and the line and phase currents. Indicate numerical values of all quantities. 7 The intensity of light bulb is high in this case compared to the earlier cases in part1. Explain the reason.

- 9-2.2 (a) A balanced RC load. Connect the same balanced RC load as in Part 1.2 a). Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #5. Table #5: 3-Ø three wire supply system with a balanced -connected Resistive and Capacitive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = Zero MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 2.2 (b) Report. I 7 = 6 Determine the power factor (PF) of the load and compare it with the PF calculated in Part 1.2 (a). Explain the reason(s) for any differences between the power factors of Part 1.2 (a) and 2.2 (a). 7

- 10-2.3 (a) An unbalanced resistive load. (Note: If you have changed the meter connections in 2.1(a), do not forget to revert back the connections while the circuit breaker is OFF.) Connect the same unbalanced resistive load as in Part 1.3 (a). Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #6. Table #6: 3-Ø three wire supply system with an unbalanced -connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = Zero MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 2.3 (b) Report. I 7 = 6 7 Find out the relationship between the measured line and phase voltages. Find out the relationship between the measured line and phase currents. Calculate the total power dissipated in the connected resistors from the wattmeter measurements. Calculate the total power supplied to the Y connected load from the phase current and phase voltage measurements and power factor of each phase. Compare the two powers and comment. Draw the phasor diagram of the power system. Include the line voltages, the phase voltages and the line and phase currents. Indicate numerical values of all quantities.

- 11 - Part 3: 3-Ø four wire supply system with a Y connected load. Refer to the circuit as shown in Figure#1 to understand the configuration. Select the neutral switch to the close position and select the Y- switch to the Y position on the source-load-interfacing-box. Select the voltage coil of the watt-meters at 120V position. 3.1 (a) A balanced resistive load. Connect the same balanced resistive load that was used for Part 1.1 (a). Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #7. Table #7: 3-Ø four wire supply system with a balanced Y-connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 I 7 = 6 7 3.1 (a) Report. Compare the values of measured voltages, current and power with those recorded in Part 1.1 (a).

- 12-3.2 (a) An unbalanced resistive load. Connect the same unbalanced resistive load that was used for Part 1 c). Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #8. Remove the load. Table #8: 3-Ø four wire supply system with an unbalanced Y-connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = Zero 1 V ca = I 3 = W 3 = 2 V a = I 4 = MF 1 = 3 V b = I 5 = MF 2 = Zero 4 V c = I 6 = MF 3 = 5 3.2 (b) Report. I 7 = 6 Compare the values of the voltages, currents and power with those measured in Part 1.3(a). Draw a current phasor diagram of this power system and indicate the value and show why Kirchhoff s current law for the phasors is obeyed. 7

- 13-3-Ø Power measurement using Three-Wattmeter-Method Refer to the circuit as shown in Figure#3 to understand the configuration. To change from two-watt-meter method to three-watt-meter method, the common point (i.e the common point of all the pressure coils of the watt-meters) should be shifted from Y-phase to neutral point. Ask the lab instructor or TA to verify it. Select the neutral switch to the close position, select the Y- switch to the Y position and select the voltage coil of the watt-meters at 120 position. 3.3 (a) A balanced resistive load. Connect the same balanced resistive load that was used for Part 3.1 (a). Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #9. Table #9: 3-Ø four wire supply system with a balanced Y-connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = 1 V ca = I 3 = W 3 = 2 V a = I 4 = MF 1 = 3 V b = I 5 = MF 2 = 4 V c = I 6 = MF 3 = 5 I 7 = 6 7 3.3 (b) Report. Calculate the total power dissipated in the load from the wattmeter measurements. Compare the total power obtained from 3.3(a) to the total power obtained from 3.1 (a) and comment. Compare the total power obtained from 3.3(a) to the total power obtained from 1.1 (a) and comment.

- 14-3.4 (a) An unbalanced resistive load. Connect the same unbalanced resistive load that was used for Part 3.2 (a). Record the line-to-line voltages, the phase voltages, the line currents, the phase currents, the neutral current and the wattmeter readings in Table #10. Table #10: 3-Ø four wire supply system with an unbalanced Y-connected Resistive load. V ab = I 1 = W 1 = Load Mapping Row # Red Yellow Blue V bc = I 2 = W 2 = 1 V ca = I 3 = W 3 = 2 V a = I 4 = MF 1 = 3 V b = I 5 = MF 2 = 4 V c = I 6 = MF 3 = 5 3.4 (b) Report. I 7 = 6 7 The sum of the wattmeter readings of Part 3.2 (a) is different than the sum of the wattmeter readings for Part 3.4 (a) while the values of load current remained unchanged. In which case are the wattmeter readings correct? Use the experimental data to prove your answer. Remove the load and de-energize the circuit. Congratulations! You have now completed the experimental part of the lab. Prepare a report based on the above test results and submit on or before the due date i.e. Friday, October 20 by 8:30am in hardcopy or Monday, October 23 by 8:30am in softcopy. REPORT due dates are posted on the ece261 web page. Submit all pre-lab and post-lab reports via Course Books. Ece261-LS1-pre.pdf is the filename.file_type format. Revisions up until the due time should hve a letter added i.e. ece261-ls1-pre-a.pdf. One revision allowed for each exercise type (pre-lab or post-lab)

- 15 - Figures: A A1 W1 A6 C R A5 3f 208V 60Hz B C A2 C R R C A3 W3 A7 N 3f Variable Autotransformer A4 SW Fig.#1: Wye Connected Load 1. Balanced Resistive, neutral switch open. 2. Balanced Resistive and Capacitive, neutral switch open. 3. Unbalanced Resistive, neutral switch open. 4. Balanced Resistive, neutral switch closed. 5. Unbalanced Resistive, neutral switch closed. A A1 W1 B 3-phase 208V 60Hz C A2 A6 A5 A7 N A3 W3 3-phase Variable Autotransformer Figure#2: Delta-connected Fig.#2: Delta Connected Load 1. Balanced Resistive. 2. Balanced Resistive and Capacitive. 3. Unbalanced Resistive.

- 16 - A A1 W1 A6 A5 3-phase 208V 60Hz B C A2 W2 A3 W3 A7 N 3-phase A4 SW Autotransformer Variable Figure#3: Wye-connected R Load Fig.#3: Wye Connected Load for 1. Balanced Resistive, neutral switch closed. 2. Unbalanced Resistive, neutral switch closed.

- 17 - A picture of the overall workstation is shown below. Wall panel circuit breaker Meters Wye - Delta source-load interfacing box Resistive load bank

- 18 - Wye-Delta and Neutral switches on the patch panel. Remember to take the load off and to turn the power off before changing the circuit. Wye - Delta switch Neutral switch

- 19 - The meter arrangement is shown below. A single voltmeter is also available at each workstation to measure the appropriate voltages. Phase current meters Line current meters & watt-meters

- 20-3 capacitor boxes