Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

Similar documents
Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Assembly. Front view. Power Rail

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Level Measurement. Applications. Special features. Description

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Note The module converts unipolar and bipolar input signals

Electronic Circuit Breaker ESS1 for System SVS1

P5201 Universal Programmable Transmitters with Galvanic Isolation

Type CP-S, CP-C & CP-A Switch mode

MINI MCR-SL-UI-f(-SP)

Connection. Composition

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Technical Information itemp TMT180

Connection. Thermocouple. Output (4 ma ma) Power supply Power Rail. Composition

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Operating Instruction

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Coupling Relays and Converters

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic Circuit Breaker ESS1 for System SVS1

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Trip amplifier, 1 channel

Moeller Electric Corporation

Differential pressure sensors

QUINT-PS-24DC/24DC/10

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Isolating Repeater Input Series 9163

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Installation / Monitoring Technique

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Temperature Transmitter itemp RTD DIN rail TMT 127

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

CONTA-ELECTRONICS. Converter Units

Accessories Power Amplifiers

Isolators A3/1.

MODEL: MRP6. Final Control Elements

XUA1 - AC Voltage and phase balance relay

MINI MCR-SL-UI-I-LP-NC

Temperature Input Module for Zone 1 Series 9482/32

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Analog Modules AS-i IP20

PHOENIX CONTACT

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Valve amplifier for proportional valves with electrical position feedback

Monitoring Relay MR 50

Valve amplifier for proportional pressure valves

Drive electronics pq11

Proportional amplifier type EV22K5

TZIF 4. Current-to-Pulse Converter 10/ EN

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Electronic timers CT-S range Selection and ordering details

Analog signal converters CC range

Universal Controller

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Zelio Control Measurement Relays

Advantages. Applications

Technical Information RMA42

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

For Immediate Delivery call KMParts.com at (866)

Liquid level monitors and controls

Phase sequence and phase failure monitor

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Signal converters Index

Electronic Thermostat TE-1 Version according to EN

Drive Electronics pq11

Electromagnetic flowmeters and switches DWM 1000/2000

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Protection and safety SQZ3 phase and sequence relay

Magnetically Actuated Linear Position Sensor WIM100-Q25L-LIU5X2-H1141

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

SINEAX U 553 Transducer for AC Voltage

Engineer s Guide. Section 9. Practical Solutions. Switches and NAMUR Sensors

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

Transcription:

Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches and potentiometer Terminal blocks with test sockets Function This signal conditioner provides the galvanic isolation beetween field circuits and control circuits. The device is a trip amplifier with two trip points. s, hysteresis and mode of operation can be set independently for both relay outputs. 0/4mA...20mA-, 0/1V...5V- or 0/2V...10V signals can be connected at the input. The device actuates the relay output when it reaches the adjusted trip points. The device is easily configured by the use of DIP switches and potentiometers. Front view DIP switch LED yellow: Relay output 1 LED yellow: Relay output 2 Potentiometer Hysteresis relay 1 Potentiometer Hysteresis relay 2 1 2 3 4 5 6 OUT1 OUT2 PWR 0% 1 60% 0% 2 60% T1 T2 7 8 9 10 11 12 13 14 15 Removable terminals green LED green: Power supply Potentiometer T1 relay 1 Potentiometer T2 relay 2 Removable terminals green Connection V ma 1+ 2+ 3- Power Rail 24 V DC 7 8 9 10 11 12 6+ 5+ 4+ 14+ 15- I II III V 24 V DC 1

General specifications Signal type Analog input Supply Connection Power Rail or terminals 14+, 15- Rated voltage U n 20... 3 DC Rated current I n 75 ma Power loss 1 W Power consumption 2.25 W (typ. 1.68 W) Input Measurement range terminals 1+, 3-: voltage 0/1... 5 V, load 50 kω or voltage 0/2... 1, load 100 kω terminals 2+, 3-: current 0/4... 20 ma ; load 50 Ω I, II terminals 7, 8, 9; 10, 11, 12 Contact loading 25 AC / 5 A / 125A; 125 V DC / 5 A / 150 W III device configuration : terminals 4, 5, 6 Transfer characteristics Deviation 0.5 % Influence of ambient temperature 0.01 % / K of adjusted trip value Input delay 100 ms Electrical isolation Input/ safe isolation acc. to DIN VDE 0106, rated insulation voltage 253 V eff Input/power supply functional insulation acc. to DIN EN 50178, rated insulation voltage 5 eff /power supply safe isolation acc. to DIN VDE 0106, rated insulation voltage 253 V eff Directive conformity Electromagnetic compatibility Directive 89/336/EEC EN 50081-2, EN 50082-2 Conformity Insulation coordination EN 50178 Electrical isolation EN 50178 Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Ambient conditions Ambient temperature -20... 60 C (-4... 140 F) Mechanical specifications Degree of protection IP20 Mass approx. 120 g Dimensions 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 in), housing type B2 Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001 General information Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. 2

Function Internal signal voltage The device converts the input signals at terminals 1, 2, and 3 into a proportional internal voltage U int between 0Vand10V. This conversion allows reaction-free verification of the input signal. The voltage is output at terminals 4+ and 3-. Internal voltage U int 1 5 V 0 ma 10 ma 5 V 2.5 V 20 ma 1 5 V s The potentiometers T1 and T2 convert the set trip points into a proportional switching voltage U pot between and 1. The voltage range corresponds to a range of 0%to100%. This voltage can be measured at terminals 3, 5, and 6. Relay output 1: Terminals 5+, 3- Relay output 2: Terminals 6+, 3- The trip point, hysteresis, mode of operation and type of alarm (high or low alarm) can be selected for each relay. High alarm means that the switching state of the relay changes when the set trip point is exceeded. This state comes to an end if the value falls below a lower limit. The difference between these two values corresponds to the hysteresis, which can be set on the front panel. With a low alarm, the alarm signal is output at values below the trip point. High alarm/relay energized S2/S3 = ON S4/S5 = ON High alarm/relay de-energized S2/S3 = ON S4/S5 = OFF Low alarm/relay energized Low alarm/relay de-energized S2/S3 = OFF S4/S5 = ON S2/S3 = OFF S4/S5 = OFF 3

Configuration DIP switch function Set the DIP switch according to the required function. S6 S5 S4 S3 S2 S1 I II Pos. I: trip point 1 responds to both relay Mode of operation High/low alarm Input range Switch Position Function S6 I 1 addresses both relay II Relay I independent of relay II S5 I Relay II energized in case of alarm II Relay II de-energized in case of alarm S4 I Relay I energized in case of alarm II Relay I de-energized in case of alarm S3 I High alarm relay II II Low alarm relay II S2 I High alarm relay I II Low alarm relay I S1 I Input ranges 0/1Vto5V or 0/4mAto20mA II Input ranges 0/2Vto10V or 0/4mAto20mA Setting the trip points with no input signal The trip points can be set using the potentiometers T1 and T2 and the proportional switching voltage U pot at terminals 5+, 3- (relay 1) and terminals 6+, 3- (relay 2). This is done using a voltage meter (measuring range 1). There must be no input signal at this point. Select the trip points in the unit of the input signal or in %. in ma, trip point TP in ma 1 I s = TP = I e = U pot = Starting point End point Proportional switching voltage U pot I s TP I e U pot = 1 x (TP - I s )/(I e - I s ) TP: 13 ma I s : 4mA I e : 20mA U pot = 1 x (13 ma - 4 ma)/(20 ma - 4 ma) = 5.6 V in ma, trip point TP in % U pot = 1 V/2 ma x (TP/100 x (I e - I s ) + I s ) TP: 75 % I s : 4mA I e : 20mA U pot = 1 V/2 ma x (75 %/100 % x (20 ma - 4 ma) + 4 ma) = 8 V 4

in V, trip point TP in V 1 U s = TP = U e = U pot = Starting point End point Proportional switching voltage U pot U s TP U e U pot = 1 x (TP - U s )/(U e - U s ) TP: 7 V U s : 2V U e : 10V U pot = 1 x (7 V - 2 V)/(1-2 V) = 6.25 V in V, trip point TP in % U pot = TP/100 x (U e - U s ) + U s TP: 45 % U s : 2V U e : 10V U pot = 45%/100% x (10V- 2V) + 2V = 5.6V Setting the trip points with an input signal The trip points can be adjusted to the input signal using potentiometers T1 and T2. No measuring device is required. For low alarm: 1. Turn the potentiometer counterclockwise as far as it will go to the left (15 turns). 2. Turn the potentiometer clockwise until the output is tripped. Each turn changes the trip point by about 7 %. 3. Set the hysteresis. This does not change the trip point. For high alarm: 1. Turn the potentiometer clockwise as far as it will go to the right (15 turns) 2. Turn the potentiometer counterclockwise until the output is tripped. Each turn changes the trip point by around 7 %. 3. Set the hysteresis. This does not change the trip point. 5

Accessories Power feed module KFD2-EB2 The power feed module is used to supply the devices with 24 V DC via the Power Rail. The fuse-protected power feed module can supply up to 150 individual devices depending on the power consumption of the devices. Collective error messages received from the Power Rail activate a galvanically-isolated mechanical contact. Power Rail UPR-03 The Power Rail UPR-03 is a complete unit consisting of the electrical insert and an aluminium profile rail 35 mm x 15 mm. To make electrical contact, the devices are simply engaged. Profile Rail K-DUCT with Power Rail The profile rail K-DUCT is an aluminum profile rail with Power Rail insert and two integral cable ducts for system and field cables. Due to this assembly no additional cable guides are necessary. Power Rail and Profile Rail must not be fed via the device terminals of the individual devices! 6