Copyright June Nexans

Similar documents
SHIPLINK TM to support your performance: cable solutions and services for safety and reliability

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Complete, innovative cables range for shipbuilding industry

NETWORK CONNECTIVITY SYSTEMS

Information technology. Generic cabling systems, General requirements

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Product information. Marine, Oil & Gas.

COPPER + LWL RAW CABLES

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

CIR (Crush & Impact Resistant) VFD Power Cable

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Installation Recommendations

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

MULTIMEDIA & DATA TRANSMISSION

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

GEXOL WORLD CLASS OIL & GAS CABLES

Marine Cables General Catalogue

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

MULTIMEDIA CABLE H6091ZHB

Cables for data transmission in industrial automation

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Detailed Specifications & Technical Data

UNIRAIL D RS485 and BUS cables

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Armoured Instrumentation Cables to BS6883

CUSTOM DESIGN COAXIAL CABLES BY SICAB

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

Install & Go Cat.8 STP Trunk Cable Assembly Description

Detailed Specifications & Technical Data

Armoured Power and Control Cables to BS7917

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

SUPERIOR MARINE CABLE SOLUTIONS

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Category 6 UTP EuroClass C ca Cables

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

DNVGL-CP-0400 Edition December 2015

Nexans Industrial Solutions PRODUCT CATALOG

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

CAT 5e UTP Cable: NETSET BOX [305m], indoor

Armoured Power and Control Cables Fire Resistant

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

Data sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m

SUBMERSIBLE PUMP CABLES

Communication, Control, and Industrial Cable

Armoured Power and Control Cables to BS6883

Railway products. Edition 2014

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

To keep your family safe and protected V-Guard Wires & Cables

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

UTP Cat 5e cable (200 MHz) (PVC sheath)

CABLE.

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Category 6 A F/FTP Euroclass C ca Cables

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

15 years of experience

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

Contents. Category7 SSTP Solid Indoor Cable - Page 03

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Detailed Specifications & Technical Data

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

MarineLine YOZp 0,6/1 kv

kv: medium voltage reeling cable with fibreoptics

EXCELLENT ELECTRICAL PERFORMANCES

Speedflex. Halogen free coaxial cables.

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Power Cables and their Application

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Medium Voltage Power Cables

Data sheet Patch cord Cat.6 A AWG m yellow

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Detailed Specifications & Technical Data

T E C H N I C A L D A T A for

Copper and Fiber Optic Cables

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Amphenol Cable. Features Allows for mass termination Up to 64 conductors

DataTwist 5 ScTP Cable

Selection table for flat & ribbon cables

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

ACR (Attenuation to Crosstalk Ratio) ACR-F. Alien Crosstalk. Attenuation (signal attenuation, conductor attenuation)

Transcription:

Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical fiber cable solutions to the infrastructure, industry and building markets. Its cables and systems can be found in every area of people s lives, from telecommunications and energy networks, to handling, buildings, aeronautics, aerospace, shipbuilding, automobiles, medical applications, railways, petrochemicals, etc. Nexans is listed on the Paris Stock Exchange. Industry Activity 170, avenue Jean Jaurès - 69353 Lyon Cedex 07 - France Phone: 33 (0)4 72 72 24 24 - Fax: 33 (0)4 72 72 95 74 - Web: www.nexans.shipbuilding.com Copyright June 2005 - Nexans

Marine Edition 2005

Symbols Temperature Admissible ambient temperature for continuous duty operation Weather Resistance to severe weather conditions Impacts Cable mechanical resistance to impacts Chemical attacks Resistance to chemicals. Fire Performances Fire performance according to: «Flame retardant» IEC 60332-1 «Fire retardant» IEC 60332-3 Category A, B or C «Fire resistant» IEC 60331 Smoke-Corrosivity-Toxicity Smoke density, gases corrosivity and toxicity Flexibility Bending Radius R R = n x outer diameter Copyright June 2005 - Nexans Halogen free Electro Magnetic Interference Cl Br Fl EMI 1

Shipboard cables Generalities 1 - Applications 4 2 - Insulation and sheathing materials 4 3 - Certifications 4 4 - Fire performance 6 Page Shipboard cables 5 - Cables Voltage Temperature Page Instrumentation, control and communication cables TX (C) mp - mt* 150/250 (300) V 90 C 8 TX (C) 331 mp - mt* 150/250 (300) V 90 C 10 TX (I) mp - mt* 150/250 (300) V 90 C 12 TX (I) 331mp - mt* 150/250 (300) V 90 C 14 TCX (C) mp - mt* 150/250 (300) V 90 C 16 TCX (C) 331 mp - mt* 150/250 (300) V 90 C 18 TCX (I) mp - mt* 150/250 (300) V 90 C 20 TCX (I) 331mp - mt* 150/250 (300) V 90 C 22 COAXIAL 80 C 24 Profibus 85 C 26 Local Area Network (LAN) FTP cables 60 C (Cat. 5)/40 (Cat.6) 28 Local Area Network (LAN) S-FTP cables 70 C 30 MX 250 V - 0.6/1 kv 90 C 32 FLAMEX Wiring cables 750 V 150 C 34 Multicore 0.6/1 kv 105 C 36 MPRX 150/250 (300) V - 0.6/1 (1.2) kv 90 C 38 MPRX -FLEX 0.6/1(1.2 kv 90 C 42 MPRX 331 0.6/1 (1.2) kv 90 C 44 MPRX -F 0.6/1 (1.2) kv 90 C 46 MPRXCX 150/250 (300) V - 0.6/1 (1.2) kv 90 C 48 MPRXCX -FLEX 0.6/1 (1.2) kv 90 C 52 MPRXCX 331 0.6/1 (1.2) kv 90 C 54 MPRXCX 6/10 (12) kv 90 C 56 MEPRXCX 8.7/15 (17.5) kv 90 C 58 (ETI) TERMINATION 6/10 kv - 8.7/15 kv 90 C 60 Technical information Data cables Power and control cables * mp: multipairs - * mt: multitriples - : registered trade mark 6 - Installation recommendations 62 7 - Electrical data 66 Page 2

Letter coding M PR EPR C X T (C) (I) F FLEX Marine XLPE insulation EPR insulation* Bare copper braid Halogen free sheath Telecommunication Control, instrumentation Collective screen Individual screen Flat cable Flexible cable * Note 1: For cable according to IEC 60331 and cross section 0.75-1 - 1.5-2.5 and 4 mm 2, insulation compound is a special Fire Resistant Halogen Free compound. Copyright June 2005 - Nexans 3

1. Application Shipboard cables manufactured by NEXANS are designed for fixed applications on board of ships. The temperature class of insulation material should be at least 10 C higher than the ambient temperature. 2. Insulation and sheathing materials 2-1 Insulation materials NEXANS has selected HF XLPE (Cross Linked PolyEthylene) for shipboard cables insulation up to 6/10kV or HF EPR (Ethylene Propylene Rubber) for higher voltage levels. These materials have excellent mechanical, chemical and electrical characteristics and meet the requirements of IEC 60092-351 (Insulation material properties ). These materials provide very low dielectric losses, thus instrumentation and telecommunication cables have very good information transmission properties. The operating temperature of the conductor is 90 C and 250 C in short-circuit. 2-2 Sheathing materials NEXANS has selected a polyolefin compound for sheathing using thermoplastic material for SHF1 or thermosetting material for SHF2. These materials demonstrate excellent mechanical, chemical properties in both SHF1 or SHF2 versions and meet the requirements of IEC 60092-359 (Sheathing material properties).the SHF2 material is recommended for permanent oil contact. Fire performance of cables sheathed with polyolefin meets the requirements of IEC 60332-3 category A and/or IEC 60331 for «Fire Resistant cables». 3. Certifications Quality system NEXANS is certified ISO 9001 by different certification bodies including Det Norske Veritas (D.N.V.) Type approvals Shipboard cables are approved by the following certification bodies. 4

Cables designation Voltage American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale TX (C) 150/250V TX (C) 331 150/250V TX (I) 150/250V TX (I) 331 150/250V TCX (C) 150/250V TCX (C) 331 150/250V TCX (I) 150/250V TCX (I) 331 150/250V COAXIAL FLAMEX 750V MULTICORES 0.6/1kV MX 250 V 0.6/1kV 150/250V MPRX 0.6/1kV MPRX -FLEX 0.6/1kV MPRX 331 0.6/1kV MPRX -F 0.6/1kV Copyright June 2005 - Nexans 150/250V MPRXCX 0.6/1kV MPRXCX 331 0.6/1kV MPRXCX 6/10kV MEPRXCX 8.7/15kV 5

4. Fire performance NEXANS Research and Developement Department has adopted a program of constant improvement for insulation and sheathing materials. Such constant developments ensure the excellent fire performance characteristics of our cables in withstanding the requirements of IEC standards. Some extracts of which follow. 4-1 Fire retardancy (IEC 60332-3) Cables, when installed (laid vertically or horizontally, bunched on cable trays, in cable conduit, pipes or trunking) are potential vectors for fire propagation. NEXANS provides totally fire retardant shipboard cables range meeting the requirements of IEC 60332-3 category A specifications. Test category Volume of Time of flame combustible application (min) (litres/mètres) A 7 40 B 3,5 40 C 1,5 20 Fire retardant test according to the IEC 60332-3 Cat.A - Cables installed in group on a vertical ladder 4-2 Fire resistance (IEC 60331) 6 In case of fire, some security circuits must maintain the power supply for vital safety equipment (emergency ligthing, alarm systems and fire pumps...). To meet such requirements, NEXANS proposes fire resistant cables (MPRX/MPRXCX 331) with mica tape + HF XLPE insulation. These cable types meet IEC 60331 specifications (750 C - 90 minutes). More over, Nexans has developped special Fire Resistant Compound to pass IEC 60331 test at 1000 C 90 minutes. Fire resistant test according to the IEC 60331

4-3 Measurements of combustion gases (IEC 60754-1/60754-2) The secondary effects of fire often cause greater damage than the fire itself. It is for this reason that NEXANS manufactures shipboard cables with Halogen Free compounds. Smoke density, toxic and corrosive gases released during combustion must be greatly reduced (hydrochloric acid measurement lower than 0.5 %). Test results meet the requirements of IEC 60754-1/60754-2. Measurements test equipment of combustion gases according to the IEC 60754-1/60754-2 4-4 Smoke opacity (/27m 3 Chamber) In case of fire, smoke emissions evolving from cables must be very low. For this reason our shipboard cables are designed to withstand the stringent requirements of -2 and the 27m 3 chamber test developped by the London Transport Executive Research Laboratory. Copyright June 2005 - Nexans Measurement of smoke opacity - 27m 3 - Chamber 7

TX (C) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TX (C) type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. TX (C) type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Collective screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange 1 2 3 4 Marking NEXANS 205 TX (C) «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 8

TX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.5* 6.0 6.3 7.2 60 4 x 2 x 0.5 8.8 9.2 10.5 100 7 x 2 x 0.5 10.5 10.9 12.0 150 10 x 2 x 0.5 12.0 12.8 14.0 220 14 x 2 x 0.5 13.5 14.4 16.0 270 19 x 2 x 0.5 16.0 16.7 18.5 350 24 x 2 x 0.5 18.0 18.7 20.5 450 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.75* 7.0 7.3 8.2 80 4 x 2 x 0.75 10.0 10.8 12.0 140 7 x 2 x 0.75 12.5 13.1 14.5 220 10 x 2 x 0.75 15.0 15.6 17.0 310 14 x 2 x 0.75 17.0 17.7 19.5 400 19 x 2 x 0.75 19.5 20.4 22.0 520 24 x 2 x 0.75 22.0 22.7 24.5 660 2 x 3 x 0.75 10.0 10.8 12.0 150 4 x 3 x 0.75 11.5 12.1 13.5 190 7 x 3 x 0.75 14.5 15.4 17.0 310 10 x 3 x 0.75 17.0 17.9 19.5 440 TX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 1.5* 8.6 8.9 10.0 130 4 x 2 x 1.5 12.5 13.4 15.0 230 7 x 2 x 1.5 15.5 16.4 18.0 370 10 x 2 x 1.5 19.0 19.7 21.5 510 14 x 2 x 1.5 21.5 22.4 24.5 690 19 x 2 x 1.5 25.0 25.8 28.0 910 Copyright June 2005 - Nexans 2 x 3 x 1.5 12.5 13.4 15.0 240 4 x 3 x 1.5 14.5 15.0 16.5 320 Stocked products Products on request *2 pairs are assembled as a quad 9

TX (C) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Design Applications TX (C) 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. TX (C) 331 type meets 60331 fire resistant performances, withstands IEC 60332-3 category A fire test on bunched cables and peforms to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Collective screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange 2 3 4 Marking NEXANS 205 TX (C) 331 1000 C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60331-1000 C IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire resistant IEC 60331 1000 C Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 10

TX (C) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.75* 7.4 7.8 9.2 110 4 x 2 x 0.75 11.0 11.6 14.0 180 7 x 2 x 0.75 13.5 14.1 16.5 280 10 X 2 X 0.75 16.0 17.0 20.0 420 14 x 2 x 0.75 18.5 19.1 22.5 520 19 x 2 x 0.75 21.0 22.0 25.5 690 24 x 2 x 0.75 24.0 24.8 28.5 890 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 2 x 3 x 0.75 11.0 11.6 14.0 190 4 x 3 x 0.75 12.5 13.0 15.5 250 7 x 3 x 0.75 16.0 16.6 19.5 400 10 x 3 x 0.75 18.5 19.5 23.0 590 TX (C) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 1.5* 9.0 9.4 10.5 160 4 x 2 x 1.5 13.5 14.2 15.5 270 7 x 2 x 1.5 17.0 17.6 19.0 440 10 x 2 x 1.5 20.0 21.0 23.0 630 14 x 2 x 1.5 23.0 23.8 25.5 810 19 x 2 x 1.5 26.5 27.4 29.5 1 060 2 x 3 x 1.5 13.5 14.2 15.5 270 4 x 3 x 1.5 15.0 16.0 17.5 370 Stocked products Products on request *2 pairs are assembled as a quad Copyright June 2005 - Nexans 11

TX (I) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TX (I) type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. TX (I) type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange 1 2 3 4 Marking NEXANS 205 TX (I) «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 12

TX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 0.5 5.4 5.7 6.6 50 2 x 2 x 0.5 8.0 8.3 9.4 90 4 x 2 x 0.5 9.4 9.8 11.0 120 7 x 2 x 0.5 11.0 11.7 13.0 190 10 x 2 x 0.5 13.0 13.9 15.5 260 14 x 2 x 0.5 14.5 15.4 17.0 340 19 x 2 x 0.5 17.5 18.2 20.0 460 24 x 2 x 0.5 19.5 20.2 22.0 580 1 x 3 x 0.5 5.8 6.0 6.8 50 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 0.75 6.2 6.5 7.4 60 2 x 2 x 0.75 9.4 9.8 11.0 130 4 x 2 x 0.75 11.0 11.4 12.5 170 7 x 2 x 0.75 13.0 13.9 15.5 260 10 x 2 x 0.75 16.0 16.7 18.5 370 14 x 2 x 0.75 18.0 18.8 20.5 490 19 x 2 x 0.75 20.5 21.6 23.5 650 24 x 2 x 0.75 23.5 24.3 26.5 840 1 x 3 x 0.75 6.4 6.8 7.8 70 2 x 3 x 0.75 11.0 11.4 12.5 160 4 x 3 x 0.75 12.0 12.7 14.0 220 7 x 3 x 0.75 15.5 16.2 18.0 350 10 x 3 x 0.75 18.0 18.9 20.5 510 TX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) Copyright June 2005 - Nexans 1 x 2 x 1.5 7.4 7.7 8.6 90 2 x 2 x 1.5 11.5 12.0 13.5 190 4 x 2 x 1.5 13.5 14.0 15.5 270 7 x 2 x 1.5 16.5 17.3 19.0 440 10 x 2 x 1.5 19.5 20.6 22.5 610 14 x 2 x 1.5 22.5 23.4 25.5 820 19 x 2 x 1.5 26.0 27.0 29.0 1 020 1 x 3 x 1.5 7.8 8.1 9.2 100 2 x 3 x 1.5 13.5 14.0 15.5 260 4 x 3 x 1.5 15.0 15.6 17.0 350 Stocked products Products on request 13

TX (I) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Design Applications TX (I) 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. TX (I) 331 type meets IEC 60331 fire resistant performances, withstands IEC 60332-3 category A fire test on bunched cables and peforms to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange 2 3 4 Marking NEXANS 205 TX (I)331 1000 C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60331-1000 C IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire resistant IEC 60331 1000 C Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 14

TX (I) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 0.75 6.6 6.9 8.2 80 2 x 2 x 0.75 10.0 10.5 12.5 150 4 x 2 x 0.75 12.0 12.4 14.5 210 7 x 2 x 0.75 14.5 15.1 17.5 340 10 x 2 x 0.75 17.0 17.9 21.0 470 14 x 2 x 0.75 19.5 20.4 23.5 630 19 x 2 x 0.75 22.5 23.5 27.0 830 24 x 2 x 0.75 25.0 26.2 30.0 1 060 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 1 x 3 x 0.75 7.0 7.3 8.6 80 2 x 3 x 0.75 12.0 12.4 14.5 210 4 x 3 x 0.75 13.0 13.6 16.0 270 7 x 3 x 0.75 16.5 17.4 20.5 450 10 x 3 x 0.75 19.5 20.5 23.5 660 TX (I) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 1.5 7.8 8.1 9.2 100 2 x 2 x 1.5 12.0 12.7 14.0 220 4 x 2 x 1.5 14.5 15.0 16.5 310 7 x 2 x 1.5 17.5 18.3 20.0 500 10 x 2 x 1.5 21.0 22.1 24.0 700 14 x 2 x 1.5 24.0 25.0 27.0 950 19 x 2 x 1.5 28.0 28.9 31.0 1 260 1 x 3 x 1.5 8.2 8.6 9.6 110 2 x 3 x 1.5 14.5 15.0 16.5 300 4 x 3 x 1.5 16.0 16.7 18.5 410 Copyright June 2005 - Nexans Stocked products Products on request 15

TCX (C) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TCX (C) type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open decks installation, cables have to be covered against UV rays. TCX (C) type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore,this especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Separator Polyester tape 4. Armouring Bare copper braid with bare copper drain wire. 5. Outer sheath Polyolefin Colour: orange 1 2 3 4 5 Marking NEXANS 205 TCX (C)* «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60332-3 Cat. A IEC 60754-1/60754-2 * except for 1 pair and 1 triple, the cable marking is TCX(I) Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 16

TCX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 0.5 6.4 6.6 7.6 60 2 x 2 x 0.5* 6.8 7.2 8.2 90 4 x 2 x 0.5 9.6 10.1 11.5 150 7 x 2 x 0.5 11.5 12.0 13.5 210 10 x 2 x 0.5 13.5 14.4 16.0 320 14 x 2 x 0.5 15.0 15.8 17.5 380 19 x 2 x 0.5 17.5 18.3 20.0 490 24 x 2 x 0.5 19.5 20.3 22.0 600 1 x 3 x 0.5 6.6 6.9 7.8 80 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TCX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 0.75 7.0 7.4 8.4 90 2 x 2 x 0.75* 7.8 8.2 9.2 110 4 x 2 x 0.75 11.5 11.9 13.0 200 7 x 2 x 0.75 14.0 14.7 15.5 280 10 X 2 X 0.75 16.5 17.2 19.0 440 14 x 2 x 0.75 18.5 19.1 21.0 530 19 x 2 x 0.75 21.0 21.8 23.5 670 24 x 2 x 0.75 23.0 24.1 26.0 830 1 x 3 x 0.75 7.4 7.7 8.6 100 2 x 3 x 0.75 11.0 11.7 13.0 200 4 x 3 x 0.75 12.5 13.0 14.5 250 7 x 3 x 0.75 16.0 16.8 18.5 420 10 x 3 x 0.75 18.5 19.5 21.0 580 TCX (C) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 1.5 8.2 8.6 9.6 120 2 x 2 x 1.5* 9.4 9.8 11.0 170 4 x 2 x 1.5 14.5 15.0 16.5 340 7 x 2 x 1.5 17.0 18.0 19.5 490 10 x 2 x 1.5 20.0 21.1 23.0 680 14 x 2 x 1.5 23.0 23.8 25.5 850 19 x 2 x 1.5 26.0 27.2 29.5 1 100 Copyright June 2005 - Nexans 1 x 3 x 1.5 8.6 9.0 10.0 140 2 x 3 x 1.5 13.5 14.3 16.0 300 4 x 3 x 1.5 15.5 16.4 18.0 430 7 x 3 x 1.5 20.0 20.7 22.5 660 Stocked products Products on request * 2 pairs are assembled as a quad 17

TCX (C) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Applications TCX (C) 331 type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open deck installation, cables have to be covered against UV rays. TCX (C) 331 type meets IEC 60331fire resistant performances, withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Separator Polyester tape 4. Armouring Bare copper braid with bare copper drain wire. 5. Outer sheath Polyolefin Colour: orange 1 2 3 4 5 Marking NEXANS 205 TCX (C) 331 *1000 C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking * except for 1 pair and 1 triple, the cable marking is TCX(I) Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60331-1000 C IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire resistant IEC 60331 1000 C Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 18

TCX (C) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 0.75 7.4 7.8 9.2 100 2 x 2 x 0.75* 8.4 8.7 10.5 140 4 x 2 x 0.75 12.0 12.7 15.0 250 7 x 2 x 0.75 15.0 15.7 18.5 410 10 x 2 x 0.75 17.5 18.4 21.5 560 14 x 2 x 0.75 20.0 20.7 24.0 690 19 x 2 x 0.75 22.5 23.6 27.5 880 24 x 2 x 0.75 25.0 26.2 30.0 1 090 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 1 x 3 x 0.75 7.8 8.2 9.6 120 2 x 3 x 0.75 12.0 12.7 15.0 260 4 x 3 x 0.75 14.0 14.6 17.0 360 7 x 3 x 0.75 17.5 18.2 21.0 550 10 x 3 x 0.75 20.0 20.9 24.5 750 TCX (C) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 2 x 1.5 8.6 9.0 10.0 130 2 x 2 x 1.5* 9.8 10.3 11.5 190 4 x 2 x 1.5 15.0 15.8 17.5 380 7 x 2 x 1.5 18.0 19.0 20.5 560 10 x 2 x 1.5 21.5 22.6 24.5 790 14 x 2 x 1.5 24.5 25.4 27.5 990 19 x 2 x 1.5 28.0 29.0 31.0 1 280 1 x 3 x 1.5 9.2 9.5 10.5 150 2 x 3 x 1.5 15.0 15.8 17.5 390 4 x 3 x 1.5 16.5 17.5 19.0 500 7 x 3 x 1.5 21.0 22.1 24.0 770 Copyright June 2005 - Nexans Stocked products Products on request * 2 pairs are assembled as a quad 19

TCX (I) Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications TCX (I) type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open decks installation, cables have to be covered against UV rays. TCX (I) type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore,this especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Separator Polyester tape 5. Armouring Bare copper braid with bare copper drain wire 6. Outer sheath Polyolefin Colour: orange 1 2 3 4 5 6 Marking NEXANS 205 TCX (I) «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 20

TCX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.5 9.0 9.4 10.5 140 4 x 2 x 0.5 10.0 10.7 12.0 170 7 x 2 x 0.5 12.0 12.8 14.0 250 10 x 2 x 0.5 14.5 15.3 17.0 380 14 x 2 x 0.5 16.0 17.0 18.5 470 19 x 2 x 0.5 19.0 19.6 21.5 600 24 x 2 x 0.5 20.5 21.6 23.5 740 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES TCX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.75 10.0 10.7 12.0 180 4 x 2 x 0.75 12.0 12.5 14.0 230 7 x 2 x 0.75 15.0 15.5 17.0 380 10 x 2 x 0.75 17.5 18.1 20.0 520 14 x 2 x 0.75 19.5 20.4 22.0 650 19 x 2 x 0.75 22.5 23.2 25.0 830 24 x 2 x 0.75 24.5 25.7 27.5 1 020 2 x 3 x 0.75 12.0 12.5 14.0 230 4 x 3 x 0.75 13.0 13.6 15.0 290 7 x 3 x 0.75 17.0 17.6 19.5 500 10 x 3 x 0.75 19.5 20.5 22.5 700 TCX (I) 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 1.5 12.5 12.9 14.5 260 4 x 2 x 1.5 15.0 15.6 17.0 380 7 x 2 x 1.5 18.0 18.7 20.5 570 10 x 2 x 1.5 21.5 22.2 24.0 820 14 x 2 x 1.5 24.0 25.0 27.0 1 010 19 x 2 x 1.5 27.5 28.6 31.0 1 310 Copyright June 2005 - Nexans 2 x 3 x 1.5 15.0 15.6 17.0 380 4 x 3 x 1.5 16.5 17.2 19.0 490 Stocked products Products on request 21

TCX (I) 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Lloyd s Register of Shipping Design Applications TCX (I) 331 type is used on board of ships in all locations for installations complying with IEC standards 60092-352. For open decks installation, cables have to covered against UV rays. TCX (I) 331 type meets IEC 60331 fire resistant performances, withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Special Fire Resistant Halogen Free Compound 3. Individual screen Alu/Polyester tape with a tinned copper drain wire 4. Separator Polyester tape 5. Armouring Bare copper braid with bare copper drain wire 6. Outer sheath Polyolefin Colour: orange 2 3 4 5 6 Marking NEXANS 205 TCX (I) 331 1000 C «voltage» «n» x 2 «or» 3 x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Core 1: white + printed number Core 2: blue + printed number Core 3: red + printed number Standards IEC 60228 IEC 60092-350 IEC 60092-376 IEC 60331-1000 C IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire resistant IEC 60331 1000 C Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 22

TCX (I) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 0.75 11.0 11.4 13.5 220 4 x 2 x 0.75 12.5 13.3 15.5 280 7 x 2 x 0.75 16.0 16.5 19.0 470 10 x 2 X 0.75 18.5 19.5 22.5 660 14 x 2 x 0.75 21.0 21.8 25.5 800 19 x 2 x 0.75 24.0 24.9 28.5 1 030 24 x 2 x 0.75 26.5 27.8 32.0 1 300 INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES 2 x 3 x 0.75 12.5 13.3 15.5 280 4 x 3 x 0.75 15.4 15.2 17.5 400 7 x 3 x 0.75 18.0 19.0 22.0 610 10 x 3 x 0.75 21.0 22.1 25.5 850 TCX (I) 331 150/250 (300)V Cables Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 2 x 1.5 13.5 13.6 16.0 330 4 x 2 x 1.5 16.0 16.4 18.0 430 7 x 2 x 1.5 19.0 19.9 21.5 650 10 x 2 x 1.5 22.5 23.7 25.5 920 14 x 2 x 1.5 25.5 26.4 28.5 1 150 19 x 2 x 1.5 29.5 30.5 33.0 1 500 24 x 2 x 1.5 33.0 34.4 37.0 1 970 2 x 3 x 1.5 15.5 16.4 18.0 420 4 x 3 x 1.5 17.5 18.1 20.0 550 Copyright June 2005 - Nexans Stocked products Products on request 23

Coaxial Flamex RG Type Approval Certificates Bureau Veritas Applications High Frequency Data transmission (communication equipment, radar, instrumentation equipment). Video sugnal transmission Max conductor temperature: 80 C Design 1. Conductor - Stranded bare, tinned or silvered copper - Bare copper weld for RG 59 2. Dialectric Plain PE (polyethylene) 3. Fire Barriers (tapes) 4. Screen Single or double braid Braid, tinned or silvered copper 5. Outer sheath Polyolefin Colour: black or green 1 2 3 4 5 6 Marking P FLAMEX Cable Type Standards Approved Bureau Veritas MIL C 17 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 75 C EMI 24

Coaxial 50 Ω MIL C17 Cable type Stranding Conductor Diam Dielectric Diam Braid Wire Diameter Outer Diameter Weight (kg/km) Operating Voltage FLAMEX RG 58 CU 19 x 0.18 TC 0.90 2.95 ± 0.10 0.13 TC 4.95 ± 0.10 41 1400 V FLAMEX RG 174 AU 7 x 0.16 BCw 0.48 1.52 ± 0.08 0.10 TC 2.79 ± 0.13 12.5 1100 V FLAMEX RG 213 U 7 x 0.75 BC 2.25 7.24 ± 0.18 0.18 BC 10.3 ± 0.18 165 3700 V FLAMEX RG 214 U 7 x 0.75 SC 2.25 7.24 ± 0.18 2 x 0.16 SC 10.8 ± 0.18 198 3700 V Coaxial 75 Ω MIL C17 Cable type Stranding Conductor Diam Dielectric Diam Braid Wire Diameter Outer Diameter Weight (kg/km) Operating Voltage DATA CABLES FLAMEX RG 59 BU 1 x 0.57 BCw 0.57 3.71 ± 0.10 0.16 BC 6.15 ± 0.10 58 1700 V FLAMEX RG 11 AU 7 x 0.40 TC 1.21 7.24 ± 0.18 0.18 BC 10.3 ± 0.18 146 3700 V TC: Tinned copper BC: Bare copper BCw: Bare copper weld SC: Silvered copper Technical Data COAXIAL 50 Ω MIL C17 COAXIAL 75 Ω MIL C17 Capacity (pf/m) <106 <72.2 Velocity (%) 65.9 65.9 Copyright June 2005 - Nexans 25

Type Approval Certificates Certified manufacturer according to ISO 9001 Applications Profibus cables dedicated for fixed installation on board of ship in all rooms below and decks for data technical networks in control units. PROFIBUS 1 x 2 x AWG 24 100 Ω 4 pairs or 2 x 4 pairs Category 5/6 Max conductor temperature: 85 C Design 1. Conductor Standred bare copper 2. Insulation Irradiated XLPE 3. Overall Screen PETP-Alu-Foil + tinned copper braid 4. Outer sheath Halogen Free Cross linked material 1 2 3 4 Marking NEXANS RHEYHALON Series 991 Profibus 150Ω Core Identification Red-green Standards Factory Standard IEC 60332-1 IEC 60754-1 / IEC 60754-2 Cl Br Fl Flame retardant IEC 60332-1 Low smoke Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 40 C + 90 C 26

PROFIBUS - 1 x 2 x AWG 24 Electrical and Mechanical characteristics - Loop resistance max. 190Ω - Characteristics impedance 150Ω ± 10% (3 to 20 MHz) - Image attenuation constant max. 5dB/km (at 38.4 khz) max. 3dB/km (at 9.6 khz) - Mutual capacitance max. 35 nf/km (at 800 Hz) - Insulation resistance min. 16GΩ. km (at 20 C) Bending Radius DATA CABLES R - Fixed installation 10 x d - Repeatedely bending 20 x d d= cable diameter Copyright June 2005 - Nexans 27

LAN CABLING Applications Nexans Cabling Solutions has developed the LANmark Maritime Cabling System to support LAN communication onboard ships and on offshore units. It addresses the requirement of the marine industry for performing, highly reliable and ruggedised data networks. The LANmark Maritime product series benefits from advanced copper (LANmark-7 GG45 Maritime) and optical technologies (LANmark-OF) in order to support the deployment of LANs in office and control areas, in accommodation and living quarters as well as in processing and industrial areas. Nexans Cabling Solutions offers an application independent LAN platform that will support the existing as well as the forthcoming LAN technologies such as Ethernet, Gigabit Ethernet, 10Gigabit Ethernet, ATM, fibre channel It also offers the possibility to deploy neighbouring technologies such as CATV for entertainment, voice applications and VoIP. It is also designed to support industrial technologies such as Industrial Ethernet. Design 1. Cable Fully screened 1000 MHz Cat.7 Multimedia or fibre optic 2. Patchpanel 24 connectors GG45 Maritime Cat. 7 vibration proof or Fiber optic, for 19 racks 3. Outlet 2 connectors GG45 Maritime Cat. 7 or Fiber optic For data, voice and multimedia application For indoor or outdoor or industrial areas 4. Consolidation Point Connection of pre-assembled cabins equipement Standards ISO/IEC 11801:2002 EN 50173:2002 Draft ISO/IEC 24702 IEC 60603-7-7 IEC 61156-5 EN 50288-4-1 Please contact our commercial department for further information about LAN cabling systems: - Copper patchcords - Fibre optic patchcords - Pre-terminated copper and fibre optic cables - Multimedia adapters - Specific link / channel requirements Flame retardant IEC 60332-3 SHF1 Low smoke -2 SHF1 Cl Br Fl Halogen free IEC 60754-1 SHF1 No toxicity SHF1 No corrosivity IEC 60754-2 SHF1-20 C + 70 C EMI 28

LAN CABLING - Cable Cables Type Bandwidth Copper LANmark-7 Maritime(*) SHF1 LSFROH S-FTP 1000 MHz 7.9 mm 4 pairs AWG23-70 Kg/km Indoor N10m.002 Copper LANmark-7 Oil & Gas Mud Resistant S-FTP 1000 MHz 8.9 mm 4 pairs AWG23-72 Kg/km Drilling / N10g.002 exposed area Fibre LANmark-OF Tight Buffer 50/125 OM2 Various 2-4 -6-8 - 12-24 cores Indoor / Several P/N 2-4 -6-8 - 12-24 or OM3 Outdoor Single/Multimode Fiber 9/125 OS1 (*) SHF1 : Fire Performance according to IEC 60332-3-24, IEC 60754-1, IEC 60754-2, -2 LAN CABLING - Connectors and Couplers Nominal Diameter Conductors Cables Weight Application Part Number INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES Item Type Number of ports Connection Application Part Number Copper LANmark-7 GG45 maritime Connector 24 copper connectors RJ45 - GG45 19 patchpanels N42m.730 Fibre Fibre Optic Coupler 24 LC Duplex or 24 LC Duplex or 19 patchpanels Various 12SCDuplex or 12SCDuplex or 24 MTRJ or 24 ST 24 MTRJ or 24 ST DATA CABLES LAN CABLING - Outlets to be fitted with LANmark-7 Maritime or LANmark-OF connectors Outlet Type Number of ports Dimensions H x W x D Application Part Number Copper & Fibre Wall / Surface mount 50 x 50 mm Metal 2 50 x 50 x 55 mm Indoor N423.660 Copper & Fibre Industrial Water/dust tight 2 175 x 70 x 90 mm Industrial areas N42i.101 Copper & Fibre Din / Rail mount DIN-Rail 1 77.8 x 18 x 65 mm Technical cabinets N20i.001 LAN CABLING - Patchpanels to be fitted with LANmark-7 Maritime or LANmark-OF connectors Patchpanel Type Number of ports Copper Vibration Proof 24 copper connectors 1HU x 19 19 racks N52m001 Fibre Optic Metal / Sliding 24LCDuplex or 12SCDuplex or 24 MTRJ 1HU x 19 x 280 mm 19 racks N441.20 Fibre Optic Metal / Sliding 24 ST couplers 1HU x 19 x 280 mm 19 racks N441.201 LAN CABLING - Class F Link Performances (ISO / IEC 11801) Dimensions H x W x D Application Part Number Frequency MHz Attenuation db/100m NEXT db ACR db/100m PSNEXTdB 100 20.8 62.9 42.1 59.9 44.4 41.4 200 30.0 58.3 28.4 55.3 39.4 36.4 600 54.6 51.2-3.4 48.2 31.3 28.3 LAN CABLING - LANmark - 7 cable Performances (Typical at 20 C) ELFEXT db/100m PSELFEXT db/100m Copyright June 2005 - Nexans Frequency MHz Attenuation db/100m NEXT db ACR db/100m PSNEXTdB ELFEXT db/100m PSELFEXT db/100m 100 18.0 > 100 85.0 > 100 84.0 81.0 250 29.4 98.0 68.6 96.0 76.0 73.0 600 47.6 88.0 40.4 86.0 68.4 65.4 1 000 63.6 82.0 18.4 80.0 64.0 61.0 29

Local Area Network (LAN) FTP Cables Applications FTP 100 Ω cables for high rate data transmission at a maximum 155 MHz (Category 5) or 350 MHz (Category 6) frequency including: ATM 155 MBit/s, FDDI/CDDI 100 Mbits, Ethernet 100 Base TX, 100 Base VG, Token Ring 10 Base T, Gigabit Ethernet (Category 6). For use in environment with high signal/noise coefficient. 100 Ω 4 pairs or 2 x 4 pairs Category 5/6 Max conductor temperature: 60 C (Cat. 5) 40 C (Cat. 6) Design 1. Conductor Bare copper (Diam.: 0.52 mm-cat. 5) (Diam.: 0.55 mm-cat. 6) 2. Insulation Foam skin PE (polyethylene) 3. Screen Alu/Polyester tape Tinned copper drain wire 4. Outer sheath Polyolefin Colour: orange 1 2 3 4 Marking FTP «Number of pairs» LSZH LANMark CATEGORY 5/6 EC VERIFIED FF «MM/YY» + Metric Marking Core Identification Pair 1: white/blue Pair 2: white/orange Pair 3: white/green Pair 4: white/brown Standards EN 50173, 50167, 50228 ISO/IEC 11801 TIA/EIA 568A (Cat. 5), 568B (Cat. 6) IEC 60332-1 IEC 60754-1 / IEC 60754-2 Flame retardant IEC 60332-1 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -20 + 60 C Cat. 5-10 + 40 C Cat. 6 EMI 30

LOCAL AREA NETWORK (LAN) FTP Cables Dimensional data 4 pairs Cat. 5 2 x 4 pairs Cat. 5 4 pairs Cat. 6 Nominal diameter 5.90 5.90 x 13.00 6.80 LOCAL AREA NETWORK (LAN) FTP Cables Dimensional data Category 5 Frequency (MHz) Standard Attenuation (db 100m) Typical 20 9.2 8.8 31.25 11.8 11.2 62.5 17.1 16.2 100 22.0 21.0 DATA CABLES Category 6 Frequency (MHz) Attenuation (db 100m) 62.5 15.1 100 19.4 200 28.0 350 38.1 Mutual capacitance:........................................................ 56nF/km Linear Resistance:........................ 94Ω/km (Cat.5) and 80Ω/km (Cat.6) Skew:......................................................................... 0.15 ns/m Propagation Velocity:........................................................... 74% Transfer Impedance (at 10 MHz):....... 50 mω (Cat.5) and 45 mω (Cat.6) Characteristic Impedance:......................................100 Ohm ± 15Ω Copyright June 2005 - Nexans 31

Applications Local Area Network (LAN) S-FTP Cables S-FTP 100 Ω cables for high rate data transmission at a maximum 100 MHz frequency including: ATM 155 MBit/s, FDDI/CDDI 100 MBits, Ethernet 100 Base TX, 100 Base VG, Token Ring 10 Base T. For use in environment with high signal/noise coefficient 100 MHz, 100 Ω 4 pairs or 2 x 4 pairs Category 5 Max conductor temperature: 70 C Design 1. Conductor Bare copper (Diam.: 0.52 mm) 2. Insulation Foam skin PE (polyethylene) 3. Collective Screen Alu/Polyester tape Tinned copper drain wire + Tinned copper braid 4. Outer sheath Polyolefin Colour: orange 1 2 3 4 Marking S-FTP «Number of pairs» LSZH LANMark CATEGORY 5 EC VERIFIED FF «MM/YY» + Metric Marking Core Identification Pair 1: white/blue Pair 2: white/orange Pair 3: white/green Pair 4: white/brown Standards EN 50173, 50167 ISO/IEC 11801 TIA/EIA 568A IEC 60332-1 IEC 60754-1 / IEC 60754-2 Flame retardant IEC 60332-1 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -20 C + 70 C EMI 32

LOCAL AREA NETWORK (LAN) S-FTP Cables Dimensional data 4 pairs Cat. 5 2 x 4 pairs Cat.5 Nominal diameter 6.50 6.70 x 13.90 LOCAL AREA NETWORK (LAN) S-FTP Cables Electrical data Frequency (MHz) ISO/IEC, 11801 EN50173 Attenuation (db 100m) Next (db) ACR (db) Standard Typical Standard Typical Standard Typical 20 9.2 8.5 42 49 32.8 40 31.25 11.8 10.6 40 47 28.2 35 62.5 17.1 15.1 35 42 17.9 25 100 22.0 19.3 32 39 10 17 DATA CABLES Mutual capacitance:.............................. 45nF/km Linear Resistance:................................. 90Ω/km Skew:............................................... 0.15 ns/m Propagation Velocity:................................. 78% Transfer Impedance (at 10 MHz):.............. 20 mω Characteristic Impedance:............100 Ohm ± 15Ω Copyright June 2005 - Nexans 33

MX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MX type is used on board of ships installations complying with IEC standards 60092-352 and especially for electrical cabling of cabinet or switchboard. MX type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V 0.6/1(1.2) kv Max conductor temperature: 90 C Design 1. Conductor Flexible bare copper class 5 2. Insulation Polyolefin Colours: red, black, blue, white, green/yellow 1 2 Marking NEXANS 205 MX «voltage» 1 x «Section» mm 2 90C IEC 60332-3A «year» * * Standards IEC 60228 IEC 60092-350 IEC 60092-353 IEC 60092-376 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Cl Br Fl Fire retardant IEC 60332-3 Low smoke Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 to 80 C 34

MX 250V (0.75/1 mm 2 ) - 0.6/1kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 0.75 15 2.2 2.4 2.9 13 1 x 1 18 2.3 2.5 3.0 16 1 x 1.5 23 2.8 2.9 3.5 20 1 x 2.5 30 3.2 3.4 4.0 30 1 x 4 40 3.7 3.9 4.5 50 1 x 6 52 4.2 4.4 5.2 70 1 x 10 72 5.2 5.4 6.2 110 1 x 16 96 6.6 6.8 7.6 170 1 x 25 127 8.0 8.4 9.4 270 1 x 35 157 9.4 9.8 11.0 370 1 x 50 196 11.0 11.7 13.0 510 1 x 70 242 13.0 13.5 15.0 710 1 x 95 293 15.0 15.8 17.0 950 1 x 120 339 16.5 17.2 18.5 1190 Colour of stocked products - MX 250V (0.75/1 mm 2 ) - 0.6/1kV Stocked products Products on request Packaging : - Coil of 100 m for cross-section 16 mm 2 - Cut on request for cross-section 25 mm 2 Cables 1 x 0.75 1 x 1 1 x 1.5 1 x 2.5 Black Red Blue White Green/Yellow POWER AND CONTROL CABLES 1 x 4 1 x 6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 Copyright June 2005 - Nexans 1 x 70 1 x 95 1 x 120 35

Type Approval Certificates Bureau Veritas Applications Wiring cable for on-board instrumentation and control equipment. Thin wall insulations and light weight applications. FLAMEX Thin wall wiring cables 750 V Max conductor temperature: 150 C Design 1. Conductor Flexible tinned copper class 5 2. Insulation Halogen free compound 1 2 Marking EX.XX «cross section» «NFF 63-808-239 P3» - «production weeks and year» Core Identification FLAMEX 20 0.60/AWG 20: yellow FLAMEX 20 0.93/AWG18: white FLAMEX 20 1.34/AWG16: green FLAMEX 20 1.82/AWG14: yellow FLAMEX 20 2.61/AWG12: white Other colours on request. Standards IEC 60332-3 Cat. C IEC 60754-1/60754-2 Cl Br Fl Fire retardant IEC 60332-3 Low smoke Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 Chemicals Resistances -30 to 150 C 36

FLAMEX Wiring cable Cables Gauge AWG Conductor stranding n x Ø Section Min. Outer diameter Nom. Max. Weight approx. (kg/km) FLAMEX 20 0.38 22 19 x 0.16 TC 0.38 1.10 1.20 1.35 4.70 FLAMEX 20 0.60 20 19 x 0.20 TC 0.60 1.15 1.40 1.50 6.60 FLAMEX 20 0.93 18 19 x 0.25 TC 0.93 1.55 1.65 1.75 10.00 FLAMEX 20 1.00 18 19 x 0.25 TC 1.00 1.55 1.65 1.75 10.00 FLAMEX 20 1.34 16 19 x 0.30 TC 1.34 1.80 1.95 2.00 14.00 FLAMEX 20 1.50 16 37 x 0.23 TC 1.50 1.95 2.05 2.15 16.10 FLAMEX 20 1.82 14 37 x 0.25 TC 1.82 2.10 2.25 2.40 19.20 FLAMEX 20 2.50 14 37 x 0.25 TC 2.50 2.25 2.40 2.80 27.80 FLAMEX 20 2.61 12 37 x 0.30 TC 2.61 2.50 2.65 2.80 27.80 FLAMEX 20 4.32 14 61 x 0.30 TC 4.32 3.00 3.00 3.30 44.20 TC : Tinned Copper (1) FLAMEX 15: maximum operating temperature = +130 C Multicore cables on request. Copyright June 2005 - Nexans POWER AND CONTROL CABLES 37

Multicore Cable Type Approval Certificates Bureau Veritas Lloyd s Register Applications Multicore cable is used on board of ships installations complying with IEC standards 60092-3 352 and especially for shipboard industry as prefabricated cabin. Multicore cable type withstands the IEC 60332-3 category C, a fire test on bunched cables and performs to the solas requirements. All materials used to manufacture this cable are halogen free. This design ensures that non corrosive and low toxic gases are emiitted in case of fire. 0.6/1 kv Max conductor temperature: 105 C Design 1. Conductor Tinned copper 1.5 mm 2 (37 x 0,223) 2.5 mm 2 (37 x 0,30) 2. Insulation Cross Linked Halogen Free compound 3. Outer sheath Cross Linked TPE Colour: black 1 2 3 Marking FLAMEX «n» x «s» G Filotex P EDE «item reference» 0.6/1 kv 105 C + Batch Number Core Identification 3 cores: black - red - green/yellow 5 cores: black - red - blue - black - green/yellow Standards IEC 6092-350 IEC 60332-3 Cat. C IEC 60754-1/60754-2 Cl Br Fl Fire retardant IEC 60332-3 Cat. C Low smoke Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 C + 105 C 38

MULTICORE CABLE Multicore - 3 G 1.50 - Insulation diameter 2.00 mm - Outer sheath diameter 5.40 mm ± 0.30 mm Multicore - 3 G 2.50 - Insulation diameter 2.45 mm - Outer sheath diameter 6.40 mm ± 0.30 mm Copyright June 2005 - Nexans POWER AND CONTROL CABLES 39

MPRX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRX type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. MPRX type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 (Sector-shaped: 70 mm 2 3 cores) 2. Insulation XLPE (cross linked polyethylene) 3. Outer Sheath (Filler if necessary) Polyolefin Colour: black 1 2 3 Marking NEXANS 205 MPRX «voltage» «n» x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification 1 core: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow For the voltage 250 V and from 5 cores and above 0.6/1 kv: white with black printed numbers Standards IEC 60228 IEC 60092-350 IEC 60092-353 IEC 60092-376 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Cl Br Fl Fire retardant IEC 60332-3 Low smoke Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C 40

MPRX 150/250 (300) V Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 0.75 13 6.0 6.2 7.2 50 3 x 0.75 11 6.2 6.5 7.4 60 5 x 0.75 9 7.4 7.7 8.6 80 7 x 0.75 8 8.0 8.3 9.4 100 12 x 0.75 7 10.5 10.9 12.0 170 19 x 0.75 6 12.5 13.0 14.5 250 27 x 0.75 5 15.0 15.6 17.0 350 37 x 0.75 5 17.0 17.6 19.0 470 MPRX 0.6/1 (1.2)kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 5 x 1.5 14 9.8 10.5 11.5 160 7 x 1.5 12 10.5 11.4 12.5 200 12 x 1.5 10 14.0 15.3 16.5 330 19 x 1.5 9 16.5 18.0 19.0 500 24 x 1.5 8 19.5 21.2 22.5 630 27 x 1.5 8 20.0 21.7 23.0 700 37 x 1.5 7 23.0 24.6 26.0 930 5 x 2.5 18 10.5 11.6 13.0 210 7 x 2.5 16 12.0 12.8 14.0 280 12 x 2.5 13 15.5 16.9 18.5 460 19 x 2.5 11 18.5 20.0 21.5 690 24 x 2.5 10 22.0 23.8 25.5 880 27 x 2.5 10 23.0 24.5 26.5 970 37 x 2.5 9 25.5 27.6 29.5 1 300 POWER AND CONTROL CABLES Stocked products Products on request Copyright June 2005 - Nexans 41

MPRX 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 1.5 23 4.6 5.0 5.7 40 1 x 2.5 30 5.0 5.4 6.2 50 1 x 4 40 5.6 6.0 6.8 70 1 x 6 52 5.8 6.3 7.2 90 1 x 10 72 6.6 7.1 8.0 130 1 x 16 96 7.6 8.2 9.2 190 1 x 25 127 9.6 10.1 11.5 300 1 x 35 157 10.5 11.1 12.5 400 1 x 50 196 11.5 12.5 13.5 560 1 x 70 242 13.5 14.5 16.0 770 1 x 95 293 15.5 17.2 18.5 1 030 1 x 120 339 17.0 19.3 21.0 1 290 1 x 150 389 19.0 21.4 23.0 1 610 1 x 185 444 21.0 23.6 25.5 1 970 1 x 240 522 24.0 26.8 29.0 2 530 1 x 300 601 26.0 29.4 31.5 3 130 2 x 1.5 20 7.6 8.2 8.8 80 2 x 2.5 26 8.6 9.2 10.0 100 2 x 4 34 9.6 10.4 11.5 140 2 x 6 44 10.0 11.0 12.0 200 2 x 10 61 12.0 12.8 14.0 310 2 x 16 82 14.0 15.2 16.5 460 2 x 25 108 17.5 18.8 20.5 700 2 x 35 133 20.0 21.0 22.5 930 2 x 50 167 22.5 23.8 25.0 1 290 3 x 1.5/2 x 1.5 + E 16 8.0 8.7 9.2 100 3 x 2.5/2 x 2.5 + E 21 9.0 9.7 11.0 140 3 x 4 28 10.0 11.0 12.0 190 3 x 6 36 11.0 11.9 13.0 260 3 x 10 50 12.5 13.6 15.0 390 3 x 16 67 15.0 16.2 17.5 580 3 x 25 89 19.0 20.0 21.5 890 3 x 35 110 21.5 22.4 24.0 1 290 3 x 50 137 24.0 25.6 27.0 1 780 3 x 70 Sect 169 26.5 27.4 28.5 2 370 3 x 95 Sect 205 29.5 30.7 33.0 3 130 3 x 120 Sect 237 33.0 34.2 36.5 3 940 3 x 150 Sect 273 37.0 38.2 41.0 4 910 Stocked products Products on request E= green/yellow core 42

MPRX 0.6/1 (1.2)kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 4 x 1.5 16 8.8 9.2 10.5 120 4 x 2.5 21 10.0 10.4 11.5 170 4 x 4 28 11.5 12.3 13.5 250 4 x 6 36 12.0 12.8 14.0 330 4 x 10 50 14.0 15.1 16.5 500 4 x 16 67 17.0 18.0 19.5 770 4 x 25 89 21.0 22.3 24.0 1 180 4 x 35 110 24.0 25.1 27.0 1 590 4 x 50 137 26.5 27.7 30.0 2 340 Stocked products Product on request Copyright June 2005 - Nexans POWER AND CONTROL CABLES 43

MPRX -FLEX Type Approval Certificates Lloyd s Register of Shipping Applications MPRX -FLEX type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. MPRX-FLEX using is recommended for installations in narrow space. MPRX -FLEX type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Flexible bare copper class 5 2. Insulation XLPE (cross linked polyethylene) 3. Outer sheath (Filler if necessary) Polyolefin Colour: black 1 2 3 Marking NEXANS 205 MPRX-FLEX 0.6/1 kv «n» x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification 1 cores: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow 5 cores and above: white with black printed numbers Standards IEC 60228 IEC 60092-350 IEC 60092-353 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivivity IEC 60754-2 -30 + 80 C Flexible EMI 44

MPRX -FLEX 0.6/1 kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 70 242 15.0 15.5 17.0 780 1 x 95 293 17.0 17.6 19.0 1 030 1 x 120 339 18.5 19.3 21.0 1 290 1 x 150 389 21.0 21.8 23.5 1 600 1 x 185 444 22.5 23.5 25.5 1 960 1 x 240 522 26.5 27.6 29.5 2 510 3 x 50 137 26.5 27.5 29.5 1 850 3 x 70 169 30.5 31.8 34.0 2 530 3 x 95 205 35.0 36.5 39.0 3 330 3 x 120 237 38.5 40.1 43.0 4 200 Products on request Copyright June 2005 - Nexans POWER AND CONTROL CABLES 45

MPRX 331 Type Approval Certificates China Classification Society Bureau Veritas Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRX 331 type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352 and in safety circuits, where fire resistance is required. MPRX 331 type meets the IEC 60331 fire resistant performances, withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation Cross section 1.5-2.5-4 mm 2 : Special Fire Resistant Halogen Free Compound 1000 C Cross section 6mm 2 : Mica Tape + XLPE (cross linked polyethylene) (sector shaped 70mm 2 3 cores) 3. Outer Sheath (Filler if necessary) Polyolefin Colour: black 1 2 3 Marking NEXANS 205 MPRX 331* 0.6/1kV «n» x «s» 90 C IEC 60332-3A «WW/YY» * * + Metric Marking * MPRX 331 1000 C for cross section 1.5-2.5-4 mm 2 Core Identification 1 core: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blueor green/yellow From 5 cores and above: white with black printed numbers Standards IEC 60228 IEC 60092-350 IEC 60092-353 IEC 60331-1000 C IEC 60332-3 Cat. A IEC 60754-1/60754-2 Cl Br Fl Fire resistant IEC 60331 1000 C Fire retardant IEC 60332-3 Low smoke Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C 46

MPRX 331 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 25 127 10.0 10.4 12.0 310 1 x 35 157 11.0 11.4 13.0 410 1 x 50 196 12.0 12.8 14.5 560 1 x 70 242 14.0 14.8 16.5 780 1 x 95 293 16.5 17.5 19.0 1 030 1 x 120 339 19.0 19.6 21.5 1 290 2 x 1.5 20 7.6 8.0 9.0 70 2 x 2.5 26 8.6 9.2 10.5 100 2 x 4 34 9.6 10.4 11.5 140 2 x 6 44 11.5 11.9 13.5 230 2 x 10 61 13.0 13.5 15.5 330 2 x 16 82 15.0 15.9 18.0 490 2 x 25 108 18.5 19.5 21.5 750 2 x 35 133 21.0 21.7 24.0 990 2 x 50 167 23.5 24.5 27.0 1 340 3 x 1.5 16 8.2 8.5 9.4 100 3 x 2.5 21 9.4 9.7 12.0 140 3 x 4 28 10.5 11.0 12.5 200 3 x 6 36 12.0 12.6 14.5 270 3 x 10 50 14.0 14.5 16.0 400 3 x 16 67 16.0 16.9 19.0 610 3 x 25 89 20.0 20.8 23.0 920 3 x 35 110 22.5 23.1 25.5 1 330 3 x 50 137 25.5 26.3 29.0 1 830 3 x 70 (sect) 169 27.0 28.3 30.5 2 370 3 x 95 (sect) 205 30.5 31.6 34.0 3 130 3 x 120 (sect) 237 34.0 35.1 37.5 3 930 3 x 150 (sect) 273 37.5 39.1 42.0 4 890 4 x 1.5 16 9.0 9.4 10.5 130 4 x 2.5 21 10.0 10.6 12.0 180 4 x 4 28 11.5 12.3 13.5 260 4 x 6 36 13.0 13.8 15.0 350 4 x 10 50 15.0 15.9 17.5 530 4 x 16 67 18.0 18.7 21.0 800 4 x 25 89 22.5 23.1 25.5 1 230 4 x 35 110 25.0 26.1 28.0 1 650 POWER AND CONTROL CABLES 5 x 1.5 14 9.8 10.3 11.5 170 7 x 1.5 12 10.5 11.1 12.5 210 12 x 1.5 10 14.0 14.9 16.5 350 19 x 1.5 9 17.0 17.6 19.0 520 27 x 1.5 8 20.0 21.1 23.0 730 37 x 1.5 8 23.0 24.0 26.0 980 Copyright June 2005 - Nexans 5 x 2.5 18 11.0 11.6 13.0 230 7 x 2.5 16 12.0 12.8 14.0 300 12 x 2.5 13 16.0 16.8 18.5 490 19 x 2.5 11 19.0 20.0 21.5 750 27 x 2.5 10 23.5 24.5 26.5 1 060 Stocked products Products on request 47

MPRX -F Type Approval Certificates Bureau Veritas Det Norske Veritas Lloyd s Register of Shipping Registro Italiano Navale Applications MPRX -F cable type is used for lighting distribution on board of ships in all public areas complying with IEC standards 60092-352. MPRX -F type withstands the IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Insulation XLPE (cross linked polyethylene) 3. Outer sheath Polyolefin Colour: green 1 2 3 Marking NEXANS 205 MPRX F 0.6/1kV 2 x «1.5» + E mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification Black-blue-green/yellow Dimensions 11 x 5 mm permissible current rating in open air: 16 A Standards IEC 60228 IEC 60092-350 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Cl Br Fl Fire retardant IEC 60332-3 Low smoke Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C 48

Copyright June 2005 - Nexans POWER AND CONTROL CABLES 49

MPRXCX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRXCX type is used on board of ships at all levels and open decks for installations complying with IEC standards 60092-352. The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 150/250 (300) V 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 (Sector-shaped: 70 mm 2 3 cores) 2. Insulation XLPE (cross linked polyethylene) 3. Inner covering (Filler if necessary) Lapped 4. Armouring Bare copper braid 5. Outer sheath Polyolefin Colour: black 1 2 3 4 5 Marking NEXANS 205 MPRXCX «voltage» «n» x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification 1 cores: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow For the voltage 250 V and from 5 cores and above 0.6/1 kv: white with black printed numbers Standards IEC 60228 IEC 60092-350 IEC 60092-353 IEC 60092-376 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 50

MPRXCX 150/250 (300) V Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 0.75 13 6.8 7.2 8.2 80 3 x 0.75 11 7.2 7.5 8.4 90 5 x 0.75 9 8.6 8.9 10.0 130 7 x 0.75 8 9.2 9.8 11.0 150 12 x 0.75 7 11.5 12.4 13.5 230 19 x 0.75 6 14.0 14.6 16.0 320 27 x 0.75 5 16.5 17.3 19.0 460 37 x 0.75 5 18.0 19.3 20.5 590 48 x 0.75 3 20.5 21.9 23.5 740 MPRXCX 150/250 (300) V Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 2 x 1 15 7.6 7.9 8.6 90 3 x 1 13 8.0 8.3 9.0 100 5 x 1 11 9.4 9.7 10.5 150 7 x 1 9 10.0 10.4 11.5 180 12 x 1 8 12.5 13.2 14.5 270 19 x 1 7 15.0 15.9 17.0 420 27 x 1 6 17.5 18.4 20.0 560 37 x 1 5 19.5 20.7 22.5 710 48 x 1 5 22.5 23.5 25.5 900 MPRXCX 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) POWER AND CONTROL CABLES 5 x 1.5 14 10.5 11.8 13.0 230 7 x 1.5 12 11.5 12.7 14.0 270 12 x 1.5 10 15.5 17.0 18.0 460 19 x 1.5 9 18.0 19.8 21.0 650 24 x 1.5 8 21.0 23.0 24.5 760 27 x 1.5 8 21.5 23.4 24.5 870 37 x 1.5 7 24.0 26.2 27.5 1 060 48 x 1.5 6 27.5 29.8 31.5 1 340 61 x 1.5 6 30.0 32.6 34.0 1 640 Copyright June 2005 - Nexans 5 x 2.5 18 12.0 12.9 14.5 290 7 x 2.5 16 13.5 14.6 16.0 390 12 x 2.5 13 17.0 18.7 20.5 610 19 x 2.5 11 20.0 21.8 23.5 870 24 x 2.5 10 23.5 25.6 27.5 1 100 27 x 2.5 10 24.0 26.1 28.0 1 200 37 x 2.5 9 27.0 29.2 31.5 1 560 48 x 2.5 9 31.0 33.3 35.5 1 970 61 x 2.5 8 34.0 36.4 39.0 2 420 Stocked products Products on request 51

MPRXCX 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 1.5 23 5.8 6.3 7.2 70 1 x 2.5 30 6.2 6.7 7.6 80 1 x 4 40 6.6 7.3 8.2 100 1 x 6 52 7.0 7.6 8.4 120 1 x 10 72 8.0 8.6 9.6 180 1 x 16 96 9.0 9.7 11.0 250 1 x 25 127 10.5 11.6 13.0 360 1 x 35 157 11.5 12.6 14.0 470 1 x 50 196 13.5 14.4 15.5 660 1 x 70 242 15.5 16.5 18.0 880 1 x 95 293 17.0 19.2 21.0 1 160 1 x 120 339 19.0 21.3 23.0 1 430 1 x 150 389 20.5 23.4 25.0 1 760 1 x 185 444 22.5 25.6 27.5 2 140 1 x 240 522 25.5 28.8 31.0 2 720 1 x 300 601 28.0 31.4 33.5 3 340 2 x 1.5 20 8.8 9.5 10.5 130 2 x 2.5 26 9.6 10.3 11.5 160 2 x 4 34 10.5 11.7 13.0 210 2 x 6 44 11.5 12.3 13.5 280 2 x 10 61 13.5 14.6 16.0 430 2 x 16 82 16.0 17.0 18.5 600 2 x 25 108 19.0 20.6 22.5 880 2 x 35 133 21.5 22.8 24.5 1 140 2 x 50 197 23.5 25.2 27.5 1 500 3 x 1.5/2 x 1.5 + E 16 9.2 10.0 11.0 150 3 x 2.5/2 x 2.5 + E 21 10.0 10.8 12.0 190 3 x 4 28 11.5 12.3 13.5 260 3 x 6 36 12.0 13.0 14.5 330 3 x 10 50 14.0 15.3 17.0 530 3 x 16 67 16.5 17.9 19.5 770 3 x 25 89 20.5 21.8 23.5 1 140 3 x 35 110 22.5 24.1 26.0 1 490 3 x 50 137 25.5 27.1 29.0 1 980 3 x 70 Sect 169 28.0 29.4 31.5 2 580 3 x 95 Sect 205 31.5 32.7 35.0 3 360 3 x 120 Sect 237 35.5 36.6 39.0 4 280 3 x 150 Sect 273 39.0 40.6 43.5 5 280 Stocked products Products on request E: Green/Yellow core 52

MPRXCX 0.6/1 (1.2)kV Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 4 x 1.5 16 9.8 10.7 12.0 180 4 x 2.5 21 11.0 11.9 13.0 240 4 x 4 28 12.5 13.4 15.0 320 4 x 6 36 13.5 14.7 16.0 450 4 x 10 50 15.5 16.9 18.5 640 4 x 16 67 18.5 19.7 21.5 930 4 x 25 89 22.5 24.0 26.0 1 380 4 x 35 110 25.0 26.6 28.5 1 910 4 x 50 137 28.5 29.9 32.0 2 580 Stocked products Products on request Copyright June 2005 - Nexans POWER AND CONTROL CABLES 53

MPRXCX FLEX Applications MPRXCX -FLEX type is used on board of ships in all locations below the upper metallic deck for fixed installations complying with IEC standards 60092-352. MPRXCX-FLEX using is recommended for installations in narrow space. MPRXCX - FLEX type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C Design 1. Conductor Flexible bare copper class 5 2. Insulation XLPE (cross linked polyethylene) 3. Inner covering (Filler if necessary) Lapped 4. Armouring Bare copper braid 5. Outer sheath Polyolefin Colour: black 1 2 3 4 5 Marking NEXANS 205 MPRXCX-FLEX 0.6/1 kv «n» x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking Core Identification 1 cores: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow 5 cores and above : white with black printed numbers Standards IEC 60228 IEC 60092-350 IEC 60092-353 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivivity IEC 60754-2 -30 + 80 C EMI 54

MPRXCX -FLEX 0.6/1 kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 70 242 16.5 17.5 19.0 870 1 x 95 293 18.5 19.2 21.0 1 090 1 x 120 339 20.5 21.3 23.0 1 340 1 x 150 389 23.0 23.8 25.5 1 660 1 x 185 444 24.5 25.5 27.5 1 990 1 x 240 522 28.5 29.6 31.5 2 520 3 x 50 137 28.5 29.4 31.5 1 930 3 x 70 169 32.5 33.7 36.0 2 690 3 x 95 205 37.0 38.5 41.0 3 400 3 x 120 237 41.0 42.5 45.5 4 290 Products on request Copyright June 2005 - Nexans POWER AND CONTROL CABLES 55

MPRXCX 331 Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Registro Italiano Navale Design Applications MPRXCX 331 type is used on board of ships at all levels and open decks for fixed installations complying with IEC standards 60092-352 and in safety circuits, where fire resistance is required. The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX 331 type meets the IEC 60331 fire characteristics, withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 0.6/1 (1.2) kv Max conductor temperature: 90 C 1 1. Conductor Stranded bare copper class 2 2. Insulation Cross section 1.5-2.5-4 mm 2 : Special Fire Resistant Halogen Free Compound 1000 C Cross section 6mm 2 : Mica Tape + XLPE (cross linked polyethylene) (sector shaped 70mm 2 3 cores) 3. Inner covering (extruded or lapped) 4. Armouring Bare copper braid 5. Outer sheath Polyolefin Colour: black 2 3 4 5 Marking NEXANS 205 MPRXCX 331* «voltage» «n» x «s» mm 2 90C IEC 60332-3A «WW/YY» * * + Metric Marking * MPRXCX 331 1000 C for cross section 1.5-2.5-4 mm 2 Core Identification 1 core: black 2 cores: black-blue 3 cores: black-white-brown or black-blue-green/yellow 4 cores: black-white-brown-blue or green/yellow From 5 cores and above: white with black printed numbers Standards IEC 60228 IEC 60092-350 IEC 60092-353 IEC 60331-1000 C IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire resistant IEC 60331 1000 C Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 56

MPRXCX 331 0.6/1 (1.2) kv Cables Permissible current rating in open air (A) Min. Outer diameter Nom. Max. Weight approx. (kg/km) 1 x 25 127 12.0 13.0 14.5 410 1 x 35 157 13.5 14.6 16.0 550 1 x 50 196 15.0 15.8 17.0 720 1 x 70 242 17.0 17.8 19.5 960 1 x 95 293 19.5 20.7 22.5 1 250 1 x 120 339 22.0 22.8 24.5 1 540 2 x 1.5 20 10.0 10.5 12.0 180 2 x 2.5 26 11.0 11.7 13.0 230 2 x 4 34 12.5 12.9 14.5 290 2 x 6 44 14.0 14.8 16.5 400 2 x 10 61 15.5 16.6 18.0 570 2 x 16 82 18.0 19.0 20.5 770 2 x 25 108 21.5 22.8 24.5 1 130 2 x 35 133 24.0 25.0 27.0 1 420 2 x 50 167 26.5 28.0 30.0 1 860 3 x 1.5 16 10.5 11.2 12.5 210 3 x 2.5 21 11.5 12.2 13.5 260 3 x 4 28 13.0 13.5 15.0 340 3 x 6 36 15.0 15.7 17.5 480 3 x 10 50 16.5 17.7 19.5 680 3 x 16 67 19.0 20.0 22.0 930 3 x 25 89 23.0 24.1 26.0 1 380 3 x 35 110 25.5 26.4 28.5 1 770 3 x 50 137 28.5 29.6 32.0 2 350 3 x 70 (sect) 169 31.5 32.7 35.0 2 930 3 x 95 (sect) 205 35.5 36.6 40.0 3 870 3 x 120 (sect) 237 39.0 40.3 43.0 4 770 3 x 150 (sect) 273 42.5 44.3 48.0 5 830 4 x 1.5 16 11.5 12.1 13.5 250 4 x 2.5 21 12.5 12.9 14.5 300 4 x 4 28 14.5 15.2 16.5 440 4 x 6 36 16.0 17.0 18.5 570 4 x 10 50 18.0 19.1 21.0 810 4 x 16 67 21.0 22.2 24.0 1 160 4 x 25 89 25.5 26.9 29.0 1 720 4 x 35 110 28.5 29.7 32.0 2 220 POWER AND CONTROL CABLES 5 x 1.5 14 12.0 12.8 14.0 280 7 x 1.5 12 13.5 14.3 15.5 370 12 x 1.5 10 17.0 17.9 19.5 570 19 x 1.5 9 20.0 20.7 22.5 790 27 x 1.5 8 23.5 24.4 26.5 1 100 37 x 1.5 7 26.5 27.3 29.5 1 380 Copyright June 2005 - Nexans 5 x 2.5 18 14.0 14.7 16.0 400 7 x 2.5 16 15.0 15.8 17.5 480 12 x 2.5 13 19.5 20.3 22.0 780 19 x 2.5 11 22.5 23.4 25.5 1 070 27 x 2.5 10 27.0 27.9 30.0 1 500 Stocked products Products on request 57

MPRXCX Type Approval Certificates American Bureau of Shipping Bureau Veritas China Classification Society Det Norske Veritas Germanisher Lloyd Lloyd s Register of Shipping Registro Italiano Navale Applications MPRXCX type is used for fixed installations on board of ships at all levels and open decks. The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX type withstands IEC 60332-3 category A fire test on bunched cables and performs to the SOLAS requirements. All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships. 6/10 (12) kv Max conductor temperature: 90 C Design 1. Conductor Stranded bare copper class 2 2. Extruded semi-conductor 3. Insulation XLPE (cross linked polyethylene) 4. Screen Extruded semi-conductor Bare copper tape 5. Inner covering Polyolefin 6. Armouring Bare copper braid 7. Outer sheath Polyolefin Colour: red 1 2 3 4 5 6 7 Marking NEXANS 205 MPRXCX 6/10 kv «n» x «s» mm 2 90C IEC 60332-3A «WW/YY» + Metric Marking Core Identification By coloured thread: blue-white-red Standards IEC 60228 IEC 60092-350 IEC 60092-354 IEC 60332-3 Cat. A IEC 60754-1/60754-2 Fire retardant IEC 60332-3 Low smoke Cl Br Fl Halogen free IEC 60754-1 No toxicity No corrosivity IEC 60754-2 -30 + 80 C EMI 58