Series GLET Accessory for dataloggers series GL in modular enclosure

Similar documents
KMT - Kraus Messtechnik GmbH

KMT - Kraus Messtechnik GmbH

Calibration and Testing

User Manual CTP4/8/16

GSV-2MSD-DI IP43. Highlights

Module Input type Ranges TEDS Filters (LP = lowpass, HP = highpass) Piezoresistive bridge ±0.5 to mv/ma 1 ma exc

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

CSG110 Strain Gauge Universal Amplifier

Telemetrie-Messtechnik Schnorrenberg

Isolation (ISO), Special Overvoltage functions protection (OP) Voltage measurement PAD-V8-P 8 Voltage, up to ±50 V BW: 6 Hz ISO: 350 V DC

Signal Conditioning Amplifier

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

Model 140 Inline Amplifier

Torque Sensor Accessories and Services

Telemetrie-Messtechnik Schnorrenberg

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

4-20mA, 0-10V and general process measuring bargraph displays

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

Antenna ANTA ANTA PCB Printed

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

Signal Conditioning Amplifier

Dx: Digital Multi-Channel Telemetry System

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

IAA100/IAA200 Analog Amplifiers Voltage/Current

MECE 3320 Measurements & Instrumentation. Data Acquisition

Analog Isolation Amplifiers

TSC. Transtech Signal Conditioners. Galvanic Isolation as Standard Full Input Range Field Adjustable 0.1% Accuracy Dual Rail Mounting.

Kistler LabAmp for DynoWare

MX1615. Data sheet. Bridge/strain gauge amplifier

Absolute Process Instruments

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

ni.com Sensor Measurement Fundamentals Series

ISOLATED 4-20 ma TRANSMITTERS

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Modular Smart Interfaces

Installation, Operation and Maintenance Manual

INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

EDS-400A COMPACT RECORDER. New KYOWA ELECTRONIC INSTRUMENTS CO., LTD.

Portable Multi-Channel Recorder Model DAS240-BAT

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

Transducer for Measurement Bridges SCM90, SIGS15

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

Tel: (949) Fax: (949) IAA100 Product Manual

Analog Isolation Amplifiers

DP2000 ORDERING GUIDE To Order MODEL NO.

SEFRAM DAS Sefram. Sefram. A new family of paperless recorders 6 to 72 channels, to cover all your applications

ICPU2-8 for imc CRONOSflex (CRFX/ICPU2-8)

KMT - Kraus Messtechnik GmbH

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Load Cell Accessories and Services

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

12/4/ X3 Bridge Amplifier. Resistive bridge amplifier with integrated excitation and power conditioning. Logos Electromechanical

Function Modules GL7- DISP GL7 - SSD GL7 - DCO. Datasheet. Function Modules. Voltage Output Module

MX1616B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

12. ELECTRONICS & INSTRUMENTATION FOR TEMPERATURE

LKAT2 Portable. High Current, Portable, Multi-size Head AC / DC Current Measurement System. Application Examples. Key Features

Oscilloscope Probes and Accessories

MCTS II Multi Channel Current Transducer System. Installation Manual

MX1615B. Strain gauge bridge amplifier. Special features. Data sheet. Block diagram

DRG-SC Series Signal Conditioners

LVDT. Inductive Position Transducer. SL Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

MX1615B-R. Ultra-rugged Bridge Amplifier. Special features. Data sheet. Block diagram

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

RMC S ENSOR TELEMETRY. A Sensortelemetrie M MANNER. FGP Sensors & Instrumentation

Multifunction Calibrator - Model 8080

Correlation of Voltage and Temperature Measurement

CANHEAD. Data Sheet. Special features. Distributed measurement acquisition. B en

Telemetrie-Messtechnik Schnorrenberg

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

The Art of Measuring. Interface Technology Product Overview. ProLine

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

KMT - Kraus Messtechnik GmbH

Analog Signal Conditioning Accessories

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

COMPACT MOLECULAR-ELECTRONIC SEISMIC SENSORS

Pressure Transmitter SIL

Trip amplifier, 1 channel

Acceleration sensors With relay output for limit monitoring Analog / CANopen

AUDIO2-4 for imc CRONOSflex (CRFX/AUDIO2-4)

Our Mailing and Shipping Address:

611 Strain gauge transducer amplifier ELECTRONICS

Multipoint measuring units UPM100 and Centipede100

ASK Cards. Features Analog signal isolation Digital signal isolation. Applications

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

4830B accelerometer simulator Product overview

MTP-NT INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

Model Channels Input type Sample rate Resolution

MX1615B. Data sheet. Bridge/strain gauge amplifier

Transcription:

PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER Series GLET Accessory for dataloggers series GL in modular enclosure Models: GLET-IU-BNC-BA4 passive, conversion 4... 20 ma to 1... 5 V GLET-B513-KA-BA4 passive, trigger / logic input, alarm output GLET-B513-KA-BA4-REL active, trigger / logic input, alarm output GLET-SG2K-BNC-BI5 active, with 2-channel-strain-gauge-amplifier GLET-8B4K-BNC-BI5 active, with base rack for up to 4x 8B amplifiers GLET-IU-BNC-BA4 Passive modular enclosure for conversion of 4... 20 ma to 1... 5 V signal input via integrated 4 mm banana jacks Connection to datalogger via BNC Passive modular enclosure for conversion of up to 4 signals 0(4)... 20 ma to a precise signal 0(1)... 5 V, e. g. for acquisition with a datalogger type GL900 - input signal: I IN = 0... 20 ma or 4... 20 ma (U MAX = 30 V) - output signal: U OUT = 0... 5 V or 1... 5 V - high-precision resistances 250 Ohm (0.1 %) - electrical connections measuring signal: 4 mm banana jacks - electrical connections datalogger: BNC socket KA-BNC-iso-sw-0.5m (4 pcs.) GLET-Series_en, ALTHEN GmbH 02/2010, version 1.03 Page 1/5

GLET-B513-KA-BA4 Passive modular enclosure for trigger inputs, logic inputs and alarm outputs for dataloggers GL800 and GL900 wiring via 4 mm banana jacks Passive modular enclosure for trigger inputs, logic inputs and alarm outputs of dataloggers GL800 and GL900 - alarm outputs: open collector (see datalogger specification) - integrated 4 mm banana jack - connection to datalogger: cable B-513 GLET-B513-KA-BA4-REL Active modular enclosure for 1 trigger input, 2 logic inputs and 3 alarm outputs for dataloggers GL800 and GL900 alarm output via relay contacts wiring via integrated jack Active modular enclosure for 1 trigger input, 2 logic inputs and 3 alarm outputs of dataloggers GL800 and GL900 - alarm output via relay contacts (2x closing contact, 1x opening contact) - relay contact rating: max. 30 V, 0.5 A - integrated 4 mm banana jack - connection to datalogger: cable B-513 GLET-Series_en, ALTHEN GmbH 02/2010, version 1.03 Page 2/5

GLET-SG2K-BNC-BI5 Active modular enclosure with 2 channel strain gauge amplifier connection via BNC transducer connection via Binder connector Active modular enclosure for connection of 1 or 2 strain gauge amplifiers with galvanic isolation between supply voltage and analog output - no. of channels: 2 - sensitivity: 2 mv/v or 3 mv/v - strain gauge supply: 5 V DC, max. 15 ma per channel - analog output: 5 V or 7,5 V (max. 1 ma) - frequency response: 1 khz (-3 db) - signal output to datalogger via 2 x BNC - strain gauge transducer connection via 5-pin Binder connector KA-BNC-iso-sw-0.5m (2 pcs.) GLET-8B4K-BNC-BI5 Active modular enclosure with base rack for up to 4 8B-module amplifiers connection via BNC transducer connection via Binder connector dimensions approx. 74 x 115 x 175 mm Active modular enclosure with base rack for up to 4 8B-module amplifiers - connection transducer side: 5-pin Binder connector (supplied with mating connector) - connection to datalogger: 4 x BNC - dimensions without connections (WxHxD): approx. 74 x 115 x 175 mm GLET-Series_en, ALTHEN GmbH 02/2010, version 1.03 Page 3/5

KA-BNC-iso-sw-0.5m (4 pcs.) 8B-module amplifiers Please see detailed specification for the 8B-module amplifiers in their respective datasheets. General specification: 1500 Vrms isolation 240 Vrms input protection -40... +85 C operating temperature range DI-8B-32 / DI-8B-42 Current input modules The amplifier modules DI-8B-32/-42 convert commonly used 4 20 ma current signals to a proportional analog output voltage signal of 1... 5 V or 2... 10 V. Additionally, an isolated 15 V loop supply voltage (DI-8B42 only) is provided for transmitter excitation. A highprecision resistance for plugging into the board is supplied with the module. The galvanic isolation reduces noises and the effect of ground loops, which is barely avoidable in large and complex measuring setups. DI-8B-32 / DI-8B-42 overview: input 4... 20 ma sensor excitation 15 VDC (DI-8B-42 only) output +1... +5 V or +2...+10 V linearity ±0.02 % bandwidth 100 Hz DI-8B-34 Linearized 2- or 3-wire RTD modules The amplifier modules DI-8B-34 are designed for Pt100 sensor excitation and signal conditioning. The Pt100 resistance value varies with the temperature, i. e. the module with Pt100 sensor provides an output voltage of 0... 5 V proportional to the temperature. Since the resistance gradient over temperature is not a linear line, the signal is linearized by the module. DI-8B-34 overview: PT100 sensor input 2-,.3-wire linearity ±0.02 % bandwidth 3 Hz input resistance <30 Ohm DI-8B-35 Linearized 4-wire RTD modules The amplifier modules DI-8B-35 are designed for Pt100 sensor excitation and signal conditioning. The Pt100 resistance value varies with the temperature, i. e. the module with Pt100 sensor provides an output voltage of 0... 5 V proportional to the temperature. Since the resistance gradient over temperature is not a linear line, the signal is linearized by the module. DI-8B-35 overview: interface to 100 Ohm platinum resistance thermometer, 4-wire accuracy ±0.20 C bandwidth 4 Hz GLET-Series_en, ALTHEN GmbH 02/2010, version 1.03 Page 4/5

DI-8B-36 Potentiometer input module The module amplifier DI-8B-36 (potentiometer input module) filters, isolates, amplifies a single potentiometer input and provides an analog output signal (0... 5 V). This voltage output is controlled by a TTL logic input. The DI-8B-36 modules are designed with a completely isolated output circuit. The potentiometer excitation is provided by using two matched current sources. When using a 3-wire potentiometer, this method allows canceling the effects of lead resistances. The excitation currents are small which minimizes the self-heating of the potentiometer. DI-8B-36 overview: interface to potentiometers up to 10000 Ohm linearity 0.02 % bandwidth 3 Hz supply voltage ±5 V DI-8B-38 Strain gauge input module Each module amplifier DI-8B-38 (stain gauge input module) is a single input channel, which is filtered, isolated, amplified and converted to an analog output signal (0...5 V or ±5V). These modules can interface to full- or half-bridge strain gauges with a resistance of 100... 10000 Ohm or 300... 10000 Ohm. The bridge excitation is provided from the module with a stable 3.33 V or 10 V voltage source. DI-8B-38 overview: interface to full or half bridges bridge excitation 3.33 V or 10.00 V bridge resistance 100... 20000 Ohm or 300... 20000 Ohm output ±5 V isolation 1500 Vrms input protection 240 Vrms linearity 0.02 % bandwidth 3 khz DI-8B-45 Frequency input module Each frequency input module DI-8B-45 converts the applied input frequency (0... 500 Hz to 0... 100 khz) to a galvanic isolated output voltage of 0... 5 V. The frequency input signal can be a TTL signal or a signal with zero-crossing, but these input signals have to be connected in different ways. The galvanic isolation reduces noises and the effect of ground loops, which is barely avoidable in large and complex measuring setups. DI-8B-45 overview: input 0... 500 Hz to 0... 100 khz accuracy ±0.10 % linearity ±0.05 % Preview further GLET Accesory: GLET-B514-KA-bat: Additional battery block for a longer power-supply-independent operation (GL2/8/900) GLET-S3L-BA2/B514-BI5: Interface and excitation box for active sensors (GL200 and GL800) GLET-S3L-BNC/B514-BI5: Interface and excitation box for active sensors (GL900) GLET-TCmini-TMEBx-KA: Interfacebox with mini connector for thermoelements (GL200/800/900) Our policy is to improve specification of our products continuously, so technical and production details can be changed without any notice. GLET-Series_en, ALTHEN GmbH 02/2010, version 1.03 Page 5/5