TrendWall Floor-To-Ceiling Panels Installation Instruction

Similar documents
Assembly Instructions

Figure A. Figure B. Figure C. Figure D

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

compile system INSTALLATION GUIDE Updated January 2019

Assembly Instructions

Two Panel Frameless Bypass Door

PORTA-FAB Cleanroom Wall Systems

SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 90º PANEL

OXYGEN INSTALLATION. Revision date

Installation Instructions - Model V4JSD 1

INSTALLATION AND CARE INSTRUCTIONS

Assembly Instructions

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

NX7 SERIES 5-1/2 HANDRAIL

Workbench Instructions for Assembly

Octagon Vinyl Gazebo Assembly Instructions For 10 & 12 Models

Dublin Stalls Installation Instructions

Assembly Instructions 10 X 10 Aluminum Frame Building

Privacy Wall Glass Selections - Polished Edge Slider Door

Oxford Stalls Installation Instructions

IMPORTANT: One Corner Entry Shower Door requires two cartons.

MX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Dura-Lock Roof System

FIG. #1 - ASD-90 & USD-90 Shower Door Assembly

INSTALLATION INSTRUCTIONS

Installation Instructions

Steel Solutions USA 602 E. Walnut Street Watseka, IL p: (888) f: (815)

BioPrism Solid Surface

Angled Side Flush with Panel Face

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Series----SP3600A SHOWER DOOR

3/16 OR 1/4 FRAMELESS SWING DOOR WITH SINGLE INLINE PANEL OR TWO INLINE PANELS

3/8-16 x 3/4 cap screw. 3/8-16 hex nut for above screws. 1/4-20 x 3/4 socket cap screw. 3/16 short arm hex key (not to scale)

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

INSTALLATION INSTRUCTIONS

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

Lightline Movable Wall Installation Manual. Preliminary Draft #

4-lite Patio Door. Installation Instructions

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5232

Office Installation Guidelines

Melamine Plastic Laminate. Toilet Partition Installation Manual

AWNING / PATIO COVER INSTALLATION INSTRUCTIONS

Installation And Care Instructions. Vertical Honeycomb Shades

Low Headroom Rear Mount TorqueMaster

Qwik-Fence Installation Instructions

Installation Instructions

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space

INSTALLATION INSTRUCTIONS

Installation Manual for Metal Toilet Partitions Standard Series

INSTALLATION INSTRUCTIONS FOR PLASCORE F5075 FRAME WALL

ZAPF PANEL SYSTEM ASSEMBLY INSTRUCTIONS. It is recommended that the components be installed in the sequence of this assembly manual.

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)


Spring Loaded All Season Roll-Up Doors

Installation Manual for Metal Toilet Partitions Elite & Elite Plus Series

Revision Date: April 01, Paramount Enclosure

C-Series & S-Series Classic Frame with Transom (Single or Pair)

Mach Wall Installation Instructions

Shetland Stalls Installation Instructions

INOVO 2-LITE SLIDING PATIO DOOR

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

UNIT No FRAMELESS PIVOT SHOWER DOOR

Display Shelving Installation Instructions

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05

UNIT No. 1415NP / 1715NP / 1815NP INFINITY FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE WITH NO INLINE POST

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

Installation Instructions

F l a t S c r e e n A R M S I n s t a l l a t i o n

Interra Installation Manual

Unit No. 1413NP, 1713NP, 1813NP Infinity Continuous Hinge Frameless Door & Inline Panel with No Post Shower Enclosure

Sliding Glass Door Assembly and Installation Guide

INSTALLATION AND CARE INSTRUCTIONS


Linear Hook- on Worksurfaces

INSTALLATION INSTRUCTIONS. UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE

Model 6100 Illustrated Installation Instructions Contractors Wardrobe

Figure #1 - VSNEO Shower Door Assembly

Revised

AFCO-Rail Post INSTALLATION INSTRUCTIONS AFCO-RAIL POST

TIP FOR GETTING STARTED

FACTORY STRETCH INSTALLATION INSTRUCTIONS

STAKS. Crossover Casegoods ASSEMBLY INSTRUCTIONS

southpaw enterprises, inc.

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

Installation Instructions. Oakmont Folding Doors

Frameless Inline Door With Return QCI5263

Closet Carousel Installation Instructions. Models TKA 5 Through TKA 14 Equipped with Footswitch Controls

Model 5400H / 7000H Illustrated Installation Instructions

Installation Instructions

Transcription:

TrendWall Floor-To-Ceiling Panels Installation Instruction TrendWall Components Covered by this Instruction: Crown (and accessories) Floor Plate Solid Panel Filler Panel Wall Channel Door Section Pilaster Vinyl Base For instructions on installing Trendwall components not listed above, refer to the Installation Instructions provided with that component. Recommended Installation Tools Nylon Mallet Rubber Mallet Hammer Electric Screwdriver Drill Bit Set Phillips Head Screw Bits #2 and #3 Ladder Pliers Plumb Bob Level Steel Tape Rule Safety Glasses 1/4" (.250") Cement Drill Sabre Saw Hacksaw (Electric preferable) Utility Knife Putty Knife Tin Snips INSTALLATION SEQUENCE 1. Read through all instructions and familiarize yourself with all aspects of a TrendWall installation. 2. Note the names of common elements used in TrendWall panels. (FIG. 1) CAUTION: To avoid damage DO NOT lay flat on floor. 3. Stage TrendWall panels by height, width, surface texture and color. 4. Mark layout on the ceiling. 5. Install Crown. Fig. 1 Glass Molding Leveling Plate Glass Panel Leveling Bolt Component Mounting Rail Wall Channel Crown Connector Filler Panel Crown Straight Panel Connector 13467 Quincy St. P.O. Box 9016 Carpet Gripper Base Corner Crown Corner Corner Panel Connector Grid Block Solid Panel Transom Block Corner Pilaster Pilaster Crown Alignment Plate Ceiling Brace Door Section Door Anchor Vinyl Base Floor Plate 11/10/04 Page 1 of 16

6. Mark layout on floor from ceiling layout. 7. Install floor plate. FIG. 2 C L 3" 8. Install wall channel. 9. Stand solid and glass panels and secure with connectors. 1 5/8" Crown 3" Standard Corner Condition 10. Assemble and install Double and Bi-Fold Doors. 11. Install all Filler Panels. 12. Install Trendwall Modular Electrical System or have electrician install any required electrical hardwire outlets and switches. 1 3/8" Panel 13. Install Component Mounting Rails. 14. Install Pilaster Covers. 1 1/2" Floor Plate 15. Install Vinyl Base. 16. Install Choices or Basic Choices. 24" MARKING LAYOUT All TrendWall Dimensions are based on Centerline dimensioning. (FIG. 2) 24" 24" Exception: When extended corners are specified, the dimensions are from the inside edge of the corner to the centerline of the next panel-to-panel connection. 24" 1. Use tape or baby powder to create the layout on the ceiling to indicate where panels will be placed. (FIG. 3) 2. Measure over 1 5/8" from centerline to locate the edge of the Crown. (FIG. 3) FIG. 3 1 5/8" 11/10/04 Page 2 of 16

CROWN Start crown at a pre-formed corner. If there are no corners in the layout, start installation at a wall using a Wall Channel. IMPORTANT: Crown sections must be attached only to a structurally sound surface in the ceiling. Crown must be connected to ceiling grid at least every 2' or 4' as the ceiling grid allows. FIG. 4 FIG. 5a 1. Place a crown corner, with the long legs down, on the layout lines. Mark the crown piece where the ceiling grid intersects. Remove and drill the crown piece with a 13/64" drill bit. 2. Place the crown corner back on the layout lines and mark the ceiling grid using the holes in the crown as a template. Remove the crown. FIG. 5b 3. If the ceiling grid is recessed in the ceiling tile, place Ceiling Grid Blocks at each hole in the crown. Drill 1/4" dia. holes in block using the crown as a template or cut a notch in the block that extends past the centerline of the block. (FIG. 4) 4. Determine from layout where any T- conditions are located. Mark the centerline location on the crown. (FIG. 5a) 5. Cut a 3" wide notch (1 1/2" on each side of centerline) (FIG. 5b) in the crown on the side of the T-condition before installing it. (FIG. 5c) 6. Hold the crown against the ceiling and attach with #10x1" pan head screws. (FIG. 6) FIG. 5c FIG. 6 1 1/2 3 11/10/04 Page 3 of 16

7. Repeat with the rest of the crown needed for the layout. FIG. 7 8. To connect adjacent crown sections, insert crown alignment plates into slots of adjoining crown pieces before mounting the second crown section to the ceiling. Fasten the crown connector between crown sections with two #8x1/2" drill-point screws. (FIG. 7) Crown Connector Crown Alignment Plate 9. If it is necessary to cut a crown section, use a metal cutting power saw (do not use a fiber blade) to carefully make a straight cut. (FIG. 8) FIG.8 1st Cut 2nd Cut 3rd Cut 11/10/04 Page 4 of 16

LOCATING FLOOR PLATE Start locating the Floor Plate at the same location the crown was started. 1. Use a plumb bob or laser to locate a mark on a length of tape as shown in Figure 10. FIG. 10 Crown 2. From the mark, measure 1/8 to locate the edge of the floor plate. (FIG. 10) 3. Mark the locations for all door sections. Determine the locations by starting at a corner and add all the Panel Widths between the corner and the door section ("PW"). Then add 8 1/2" if the side panel is on the same side as the panels added or 1 3/8" if the side panel is on the opposite side. For example: a. (Vertical run in FIG. 11) "PW" is 48" (two 24" panels) and the side panel of the door section is on the same side as the two 24" panels so add 8 1/2" and 48" to get 56 1/2" from the centerline of the corner for standard corners or add 1 3/8 on extended corners, see Figure 2, to the edge of the door section cutout. b. (Horizontal run in FIG. 11) "PW" is 36" (one 36" panel) and the side panel of the door section is on the opposite side of the 36" panel so add 1 3/8" and 36" to get 37 3/8" from the centerline of the corner for standard corners or add 1 3/8 on extedned corners, see Figure 2, to the edge of the door section cutout. 4. Determine the width of the door section cutout Door Width ("DW") by measuring the width of the transom from hinge side of door frame and adding 2 1/8". For example, if the transom is 36" wide, the door section cutout ("DW") is 38 1/8". (FIG. 11) FIG. 11 Door Section 1/8 "DW" Standard Corner Door Section 24" Panel 24" Panel 1 3/8 36" Panel "PW" Center Line of Floor Plate Tape 8 1/2 "DW" (Door Width) Door Side "PW" (Panel Width) Extended Corner INSTALLING FLOOR PLATE 1. If necessary, cut the floor plate to length by cutting the side flanges with a tin snip and bending 4-5 times until the piece snaps off. (FIG. 12) CARPET CONDITION 2. Peel off backing on nylon carpet gripper. 11/10/04 Page 5 of 16

Apply carpet gripper to each floor plate. (FIG. 13 A) FIG. 12 Cut 3. Evenly space up to five (5) carpet grippers per section of floor plate. Once all carpet grippers are applied, press section of the floor plate to the floor along the layout line that is plumb to the crown. (FIG. 13 B) IMPORTANT: Carpet Grippers should always be applied as near to each end as possible and spaced uniformly along the floor plae layout line. Generally two (2) Carpet Grippers are provided per each panel ordered, independent of panel width. Each standard 12' (144") floor plate length when ordered separatelly, is provided with five (5) Carpet grippers based on a nominal 3' (36") recommended spacing betwen grippers. Each standard 6' (72") floor plate length, when ordered separately, is provided with three (3) Carpet Grippers. FIG 13 (A) Cut Bend Line (B) Floor Plate NON CARPET CONDITION 4. Place two strips of double-face tape (upon request) on the bottom of each floor plate. Remove the protective paper backing from the tape. Press sections of the floor plate to the floor along the layout line that is plumb to the ceiling crown. (FIG. 14) FIG. 14 5. Where the floor plate is installed at a corner, place one floor plate at least 1/2" back from edge and butt the floor plate from the other direction against the first piece of floor plate. (FIG. 15) 6. Where the floor plate is installed in a T- condition, simply butt the floor plate of the leg of the "T" against the straight run of floor plate. (FIG. 16) FIG. 15 7. Continue this procedure until all floor plates are attached to the floor. INSTALLING WALL CHANNEL 1. Determine from layout the location of all wall channels. 2. The wall channel is to be 3" above the floor. Use the crown as a guide by placing the wall channel on the floor and marking it where it comes to the bottom of the FIG. 16 1/2" 11/10/04 Page 6 of 16

crown. If there is no room to stand the wall channel next to the crown, measure the distance from the bottom of the crown to the top of the floor plate. (FIG. 17) FIG. 17 3. Cut wall channel as described for floor plate in "INSTALLING FLOOR PLATE, Step No. 1. 4. Slide the wall channel into the crown, make sure it is plumb, and attach to the wall with an appropriate fastener for the type of wall it is attached to. Use at least four fasteners to secure the wall channel to the wall. (FIG. 18) FIG. 18 SOLID & GLASS PANELS IMPORTANT: Before installing panels that will support a Component Mounting Rail, install a 1/2" nut on the leveling bolt. The leveling bolt must be removed, the 1/2" nut placed on the leveling bolt, and the leveling bolt reinstalled on the panel. After the panels are installed and leveled and plumbed, tighten the 1/2" nut against the panel. (FIG. 19) 1. Extend leveling bolts of panel to a length of 3 1/4" (3.25"). 2. Start installation of the panels in a preformed corner where panels will have better stability. (If a corner is not used in the layout, start attachment at the wall. See PANEL TO WALL CHANNEL. ) Install panel by first sliding the panel into the crown, then setting the leveling bolts onto the floor plate. (FIG. 20) 3. Plumb and level the panel by adjusting the leveling bolts. (FIG. 21) FIG. 19 1/2" Nut Leveling Bolt 4. Set the second panel adjacent to the first and connect it with the bottom panel connector only. (Use extended corner connectors in extended corner conditions.) Lock connector by putting ends into panel slots then turning with pliers to lock it FIG. 20 1 2 11/10/04 Page 7 of 16

into place. (FIG. 22) CAUTION: Do not bend or misalign clips. This can change the dimensions between panels and adversely affect pilaster installation. FIG.21 5. Level and plumb the second panel to the first panel by adjusting leveling bolts. Install the remaining panel connectors. Twist connectors with pliers to lock into place. 6. Continue adding panels, leveling and plumbing, and connecting in the same manner as above. FIG.22 IMPORTANT: All the panel connectors must be facing the same direction to allow electrical cabling to run between the panels. Straight Connector T-CONDITION PANELS AND EXTENDED T-CONDITIONS 1. In T-conditions, always install the panels in the following order: A. Ensure the first panel is in position and level. B. Install the next panel at 90 degrees from the first. Regular Corner Connector Panel Slots Enhanced Vinyl Base Standard Oustide Corner Pilaster Enhanced Inside Corner Pilaster Extended Corner Connector Panel Slots Enhanced Vinyl Base Enhanced Oustide Corner Pilaster 11/10/04 Page 8 of 16

C. Install the final panel in line with the first panel to complete the T-condition. (FIG. 23) FIG. 23 2. Level and plumb the panels as described in the section "SOLID & GLASS PAN- ELS." (Refer to page 7.) 3. Install all the corner connectors for the first panel connection, then install corner connectors on top of the first set to complete the T-condition. 4. Place straight connectors into vertical rail windows to ensure proper spacing of inline panels in a T-condition. (This step does not apply to extended corner conditions.) PANEL-TO-WALL PLATE ATTACHMENT 1. Locate panel in the frame of the wall channel so that the edge of the panel face is 1 3/8" less than the nominal panel width from the wall. (FIG. 24) 2. Insert the panel to the wall channel. Corner Connector Straight Connector Extended Corner Connection 3. Install the next panel in the run as described in the section "SOLID & GLASS PANELS." FILLER PANEL-TO-WALL CHANNEL ATTACHMENT The filler panel should be installed as the last panel section in the run. FIG. 24 2 3/4" 1. To determine the width of the filler panel, measure the distance from the end of the Panel Width "W" - 1 3/8" 11/10/04 Page 9 of 16

standard panel to the wall and subtract 3". (FIG. 25) Panel connectors will clear 1" conduit 2. Score fabric 1/8" from cutting line and remove to prevent it from pulling when the filler is cut. Mask fabric to prevent penetration of gypsum dust. (FIG. 26) If the panel is vinyl on both sides, scoring is not necessary. FIG. 25 1 3/8" A B 2" Between Side Rail A = Width of Opening B = Width of A Minus 3" Use a sabre saw to cut the filler panel to width. FIG 26 3. Using a putty knife, spread legs of wall channel and slide end of filler panel with no side rail into the wall channel. (FIG. 27) 4. Install leveling plate under filler panel. 5. Raise leveling bolt of the panel so its connector openings are level with the openings in the adjoining panel. 1/8" 6. Connect the adjoining panels by inserting panel connectors. Cut Line PROTRUDING WALL FILLER PANEL CONDITION 7. Cut Wall Channel to fit the contour of the wall. FIG. 27 8. Cut out back of Wall Channel to allow for overlap with the adjacent Wall Channel. (FIG. 28) Wall Plate Side Rail Straight Connector Filler Panel Leveling Plate 11/10/04 Page 10 of 16

9. Ensure there is at least 1/2" to 1" overlap on channel. (FIG. 28) 10. Then anchor Wall Channels to permanent wall. FIG. 28 Wall Channel 1/2" - 1" Wall Channel Over Lap RECESS WALL FILLER PANEL CONDITION 11. Cut Wall Channel to fit the contour of the wall. 12. Cut out back of Wall Channel to allow for overlap with the adjacent Wall Channel. (FIG. 29) Filler Panel 13. Ensure there is a least 1/2" to 1" overlap on channel. (FIG. 29) 14. Anchor Wall Channels to permanent wall. SINGLE-DOOR SECTION Do not cut the tape holding the door closed until the door is standing. Wall 1. Place the anchor bases at both ends of the cut-out in the floor plate. Drill through the floor plates and into the floor with a 5/32 (.156 ) dia. carbide tip masonry bit x FIG. 29 Wall Channel 1/2" - 1" Wall Channel Over Lap Filler Panel Wall 11/10/04 Page 11 of 16

1 3/4 min. deep hole. Fasten anchor bases to the floor with 2 1/4 long concrete screws. (FIG. 30) 2. Temporarily lower leveling bolts 1 1/2" then lift pre-assembled door section into the crown, and set the door jambs against ends of floor plates. Connect the door side panel to the adjacent panels. 3. Tilt the "T" head of the jamb anchor and fit it inside the corresponding space of the door jamb. Hand-tighten 1/2"-long bolts and washers into the jamb anchor. (FIG. 30) 4. Adjust the door jambs so they are plumb and square with the leveling bolts. Then tighten the jamb anchor bolts with a socket wrench. STABILIZER BRACKET Recommended Installation Tools: Electric Screwdriver Phillips Head Screw Bits Stabilizer Bracket (SITSB) is used to stabilize door sections and panels to the ceiling crown. 1. With the pilaster cover removed, position stabilizer bracket up and into the crown. (FIG. 31) Make sure the top of the bracket fits snugly in the crown and the lower portion is pushed completely onto the side rail so the screws can be driven into the side rail. 2. Secure the stabilizer bracket to the side rail using four (4) #7 x 7/16" long Drill Point screws. DOOR HANDSET INSTALLATION All doors and door units are shipped with door handsets disassembled and packaged. 5. Before mounting handset to door: 1. Check the latch bolt hub location. It must be centered in the handset hole. (FIG. 32) 2. Should the hub require repositioning, grasp the hub between the thumb and forefinger and slide to the correct back set position on the latch bolt body. 3. Install handset using (2) screws supplied and check the open/close and lock/unlock operation as required. 4. Refer to instructions in or on the handset carton for manufacturers recommended installation procedures. FIG. 30 FIG. 31 FIG. 32 Latch Bolt Hub Location Door Jambs Jamb Anchor Anchor Base Stabilizer Bracket Latchbolt Hub 6. Place flat blade screwdrivers between the Adjustable for 2 3/8" & 2 3/4" door frames and the crown. Hold transom backset block so pre-installed screws are toward you 11/10/04 Page 12 of 16 1 3/4 Long Concrete Screw 1/2 Long Bolt Washer

(facing away from transom). Lift block into space between crown and transom. Let block drop so it is flush with bottom of crown. Remove screwdrivers. (FIG. 33) FIG. 33 COMPONENT MOUNTING RAIL This assembly allows TrendWall panels to accept Trendway components. Crown Component mounting rail is for use with floor-to-ceiling panels only. Preinstalled Screws 1. Check the level of panels that will support components. Once the panels are level, raise the 1/2" nut that is threaded onto the leveling bolt. Tighten this nut against bottom of panel. Transom Block Transom This 1/2" nut must be installed on the leveling bolt before the panel is installed; otherwise, take the panel down to install the nut. (FIG. 34) 2. Remove pilaster from left and right sides of the panel that will support the component. FIG. 34 3. If required, cut component rail to same length as the panel side rail. Cut from top (unslotted) end. Install the first component mounting rail at the high spot of the floor. This will ensure proper installation of all component mounting rails. 4. Hold the component rail with the unslotted end up. Press the component rail into the pilaster opening. Align the bottom of the rail with the bottom of panel, place worksurface support in slotted rail and adjust the component rail so it is "X" 7/8 inches from the floor. Center the component rail in the opening then fasten with #8 x 3/4" drill-point screws through the predrilled component rail holes. (FIG. 35) FIG. 35 1/2" Nut Leveling Bolt When fastening the component mounting rail, all mounting holes must be used. 5. Hook a support bracket into the installed rail. Hook a second support bracket into the rail that is to be installed in the opposite pilaster opening. 6. Hold loose rail in the opposite pilaster opening. Place a level between the support brackets and level the loose rail. Fasten rail to panel side rails with a #8 x 3/4" drill-point screw into each mounting hole. (FIG. 36) Component Rail Component Cover 1/2" Nut 11/10/04 Page 13 of 16

7. When both component rails are attached and leveled, remove the support brackets. Use the palm of your hand or a nylon hammer to tap vinyl pilaster covers into place over component rails. FIG. 36 8. Slit vinyl pilaster so the support bracket hooks can be pushed through the pilaster to reach the slots of the component rail. (FIG. 37) COMPONENT MOUNTING RAIL WITH ELECTRICAL BOX 1. Cut 15 1/2" off the bottom (slotted) end of component mounting rail if electrical is mounted at standard height or, if the electrical box or distribution module is already installed, measure the distance from the bottom of the panel to the top of the electrical box and add 1/2" and cut the component mounting rail to this length. For example, if the electrical box is located 12" from the bottom of the panel, cut the component mounting rail 12" from the bottom. 2. Install leveling slots from previously installed rail. (FIG. 36) Install so bottom of component rail is at least 1/ 2" above electrical box or distribution module. If hardwired, a licensed electrical contractor must install all electrical components in the TrendWall system. FIG. 38 FIG. 37 1/8" (.125") Wide Cut 3. If hardwired, install electrical box (Appleton M1-250 Raco 690, Steel City GW125, or equivalent) against bottom of component rail. (FIG. 38) 4. When necessary, install an outlet or switch cover. Note: If the modular electrical punch out is provided and the switches and duplexes are Leviton Decora devices, a cover is not required. 5. Straight connector will allow for 1" conduit. Component Rail Straight Connector Component Cover Electrical Box and Hardwire Duplex Receptacle PILASTERS 1. When all panels are installed, go back and install corner pilasters into 90 conditions and straight pilasters into 180 conditions. Squeeze pilaster in between two panels at the top. Push pilaster up into the crown until it is 11/10/04 Page 14 of 16

lined up with the bottom of the panel. Be careful not to peel the vinyl or fabric from pilaster and tap into place with a nonmarring mallet or by hand. (FIG. 39) FIG. 39 2. To remove pilasters, start at the bottom and twist to remove. BASE COVER 1. Start with preformed corner and work towards wall or door section. Press the tab on the back of the base cover onto the raised lip of the floor plate. 2. If the base cover needs to be shortened, score the face of the base cover using a straight edge and a utility knife. Cut the flexible trim piece at the top and bend back to break the face. Then cut the back tab with the utility knife. 3. To determine length of base cover to be cut, measure from the adjacent base cover to the wall or the door jamb ( Dimension A ). Cut the base cover as noted above. Trim the back tab 1 1/2" from edge of base cover at the door section. (FIG. 40) Pilaster 4. To install the base end cover, place a piece of double faced tape in the notch of the end, remove the protective paper and place the end in place at the edge of the base cover and press firmly into place. (FIG. 41) FIG. 40 INSTALL GLASS IN GLAZED PANELS Glass is supplied locally, not by A 1 1/2" 11/10/04 Page 15 of 16

Trendway Corporation. CAUTION: Wear gloves when installing glass. FIG. 41 1. Press the glass into the frame against the factory installed female molding. 2. Position the bottom horizontal portion then the top of the male moldings, then position the vertical portions. Use a mallet and a wood block to tap the molding until firmly seated. (FIG. 42) 3. After molding is seated, make certain the soft vinyl seal is flat and smooth against the glass. (This can be accomplished by using an unfolded paper clip.) Base End Cover FIG. 42 Female Molding Male Molding 11/10/04 Page 16 of 16 INS138, REV L, ECN 9177 Trendway Corporation, 2004. Printed INS138 in REV USA. L