CENTRE OF TESTING SERVICE INTERNATIONAL

Similar documents
CENTRE OF TESTING SERVICE INTERNATIONAL

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED. Brushless Servo

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

EMI T E S T R E P O R T

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

EMI -- T E S T R E P O R T

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

D. Guarnone (verifier)

TEST REPORT Title 47-Telecommunication

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

King Pigeon Communication Co., Limited

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

EMI T E S T R E P O R T

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Superior communications. Wireless charger. Model Number: Additional Model: 06122

FCC PART 15 SUBPART C TEST REPORT FCC PART

3. MEASURING DEVICES AND TEST EQUIPMENT For Radiated Emission Measurement... 6

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of SUNVALLEYTEK INTERNATIONAL, INC. VAVA Docking Station. Model Number: VA-DK001

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

FCC REPORT. Dongguan Hele Electronics Co.,Ltd. * In the configuration tested, the EUT complied with the standards specified above.

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

TEST REPORT FCC PART Jacky Chen (File administrators) Allen Wang (Test Engineer) Tracy Qi (Manager)

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

Pass* * In the configuration tested, the EUT complied with the standards specified above.

FCC Verification TEST REPORT

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

FCC PART 15 SUBPART C TEST REPORT

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: MPE TEST REPORT

Verification of Conformity On Behalf of

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

APPLICATION FOR VERIFICATION On behalf of MATRIX LIGHTING LTD. LED spot light. Model No.: 50-45GUS 50-45EUS Serial No.: E /02 E /02

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System. Model No.: GTK-XB7 IC: 409B-GTKXB7

FCC & RSS GHz Report. for. Sunrex Technology Corp

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

FCC CERTIFICATION TEST REPORT

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

TEST REPORT. Issued for:

TRANSMITTER MODEL: KAS-2030M

TEST REPORT SZEM CR

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

EMI T E S T R E P O R T

FCC PART 15 B MEASUREMENT AND TEST REPORT

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

T E S T - R E P O R T. Test Report No (Edition 1) for RF340-R. Inductive Tag Reader

FCC Part 15 Subpart B

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System GTK-XB90 FCC ID: AK8GTKXB90

ORT. MobiWire. Brand. Product. Dakota. Model. Report No. April 22, Issue. TA Technology

EMI -- T E S T R E P O R T

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

FCC PART TEST REPORT. Weccan Industrial Limited

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

TEST REPORT To: - ABO ELECTRONICS (SHENZHEN) CO., LTD Block B3, Haocheng Industrial Park, Hexiu West Rd, Heping Village, Fuyong, Baoan, Shenzhen

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: -

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. DEI Sales Inc. dba Definitive Technology. Model Number: STUDIO SLIM SUBWOOFER

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

2004/104/EC Measurement and Test Report

FCC PART MEASUREMENT AND TEST REPORT

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

FCC REPORT. Lightcomm Technology Co., Ltd.

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Proware Technologies Co., Ltd. Wireless High Gain USB Adapter. Model No.

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

RF test report AU01+W02

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

FCC Test Report FCC ID: XN6-SB3651E6

RF EXPOSURE REPORT. Report Reference No... : TRE R/C.: Eucalyptus Ave., #120,Chino, CA 91710,USA. Address...

FCC Test Report. Report No.: PTCDQ FC01

APPLICATION FOR CERTIFICATION On Behalf of. Philips Consumer Electronics Company. Digital Audio Player

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

Transcription:

CENTRE OF TESTING SERVICE INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 FCC TEST REPORT TEST REPORT NUMBER : CGZ3150202-00097-E A101,No.65,Zhuji Highway,Tianhe District,Guangzhou, Guangdong, China

Report Reference No.... : TEST REPORT FOR FCC 47 CFR PART 15 OCT, 2014 Radio frequency devices CGZ3150202-00097-E Date of issue... : 04 February 2015 Testing Laboratory Name... : Address... : Testing location/ procedure... : Applicant s name... : A101, No.65, Zhuji Highway,Tianhe District, Guangzhou, Guangdong, China Full application of Harmonised standards Partial application of Harmonised standards Other standard testing method Adafruit Industries Address... : 150 Varick St. #3 New York, NY 10013 Test specification: Standard... : 47 CFR PART 15 OCT, 2014 Test Report Form No.... : TRF Originator... : CTSEMC-1.0 Master TRF... : Dated 2009-01 All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the CENTRE OF TESTING SERVICE CO., LTD. is acknowledged as copyright owner and source of the material. CENTRE OF TESTING SERVICE CO., LTD. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description.... Trade Mark... : Manufacturer... : Model/Type reference... : Ratings... : Result... Pro Trinket 5V Adafruit Adafruit Industries Pro Trinket 5V Battery 5V PASSED Compiled by: Supervised by: Approved by: Kate zhang / Fileadministrators Duke yang / Technique principal Vincent yao / Manager Report No.: CGZ3150202-00097-E Page 1 of 20

FCC -- T E S T R E P O R T Test Report No. : CGZ3150202-00097-E 04 February 2015 Date of issue Type / Model... EUT... Pro Trinket 5V Pro Trinket 5V Applicant... Adafruit Industries Address... 150 Varick St. #3 New York, NY 10013 Telephone... +1-760-884-7727 Fax... +1-760-887-8574 Contact... Mary Jungman Manufacturer... Adafruit Industries Address... 150 Varick St. #3 New York, NY 10013 Telephone... +1-760-884-7727 Fax... +1-760-887-8574 Contact... Mary Jungman Factory... Adafruit Industries Address... 150 Varick St. #3 New York, NY 10013 Telephone... +1-760-884-7727 Fax... +1-760-887-8574 Contact... Mary Jungman The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CGZ3150202-00097-E Page 2 of 20

TABLE OF CONTENTS Description Page 1 TEST STANDARDS...4 2 SUMMARY...4 2.1 GENERAL REMARKS...4 2.2 FINAL ASSESSMENT...4 3 EQUIPMENT UNDER TEST...5 3.1 Power supply system utilised...5 3.2 Short description of the Equipment under Test (EUT)...5 3.3 EUT operation mode...5 3.4 EUT configuration...5 4 TEST ENVIRONMENT...6 4.1 Address of the test laboratory...6 4.2 Test facility...6 4.3 Environmental conditions...6 4.4 Definitions of symbols used in this test report...6 4.5 Statement of the measurement uncertainty...6 4.6 Measurement Uncertainty...7 4.7 Test Description...7 5 TEST CONDITIONS AND RESULTS...8 5.1 Power Line Conducted Emission Test...8 5.2 Radiated disturbance (Electric field)...10 6 USED TEST EQUIPMENT...16 7 TEST PHOTOGRAPHS...17 7.1. Photo of radiated emission measurement (R.E.)...17 8 External and Internal Photos of the EUT...18 9 Normative references...20 10 Manufacturer/ Approval holder Declaration...20 Report No.: CGZ3150202-00097-E Page 3 of 20

1 TEST STANDARDS The tests were performed according to following standards: 47 CFR PART 15 OCT, 2014 ANSI C63.4-2009 2 SUMMARY 2.1 GENERAL REMARKS Date of receipt of test sample 02 February 2015 Testing commenced on 02~03 February 2015 Testing concluded on 04 February 2015 2.2 FINAL ASSESSMENT The FCC requirements pertaining to the technical standards and tested operation modes are - Fulfilled. - Not fulfilled. The equipment under test - Fulfils the FCC requirements cited on page 1. - Does not fulfil the FCC requirements cited on page 1. Report No.: CGZ3150202-00097-E Page 4 of 20

3 EQUIPMENT UNDER TEST 3.1 Power supply system utilised Power supply voltage: Battery 5V Others 3.2 Short description of the Equipment under Test (EUT) Number of tested samples: 1 Serial number: Prototype 3.3 EUT operation mode The equipment under test was operated during the measurement under the following conditions: Normal Operating Mode: Normal The equipment under test was operated during the measurement under the following conditions: Test program (customer specific) Emissions tests.: According to 47 CFR PART 15, searching for the highest disturbance. 3.4 EUT configuration (The CDF filled by the applicant can be viewed at the test laboratory.) The following peripheral devices and interface cables were connected during the measurement: Name: / M/N: / S/N: / Manufacturer: / Power Cord: / Certificate: / - unscreened power cables - customer specific cables Report No.: CGZ3150202-00097-E Page 5 of 20

4 TEST ENVIRONMENT 4.1 Address of the test laboratory A101, No.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China 4.2 Test facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L3394 has been assessed and proved to be in compliance with CNAS-CL01: 2006 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2005 General Requirements) for the Competence of Testing and Calibration Laboratories. IC-Registration No.: 8374A The 3m Alternate Test Site of has been registered by Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with Registration No. 8374A on May 22, 2014. FCC-Registration No.: 971995, EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files. Registration No.971995, July 13, 2012. 4.3 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15~35 C Humidity: 25~75 % Atmospheric pressure: 86~106 kpa 4.4 Definitions of symbols used in this test report - The black square indicates that the listed condition, standard or equipment is applicable for this report. - The empty square indicates that the listed condition, standard or equipment is not applicable for this report. 4.5 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16-4 Specification for radio disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC Measurements and is documented in the CTS quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. Report No.: CGZ3150202-00097-E Page 6 of 20

4.6 Measurement Uncertainty Test Item Frequency Range Uncertainty Note Conduction disturbance 150kHz~30MHz ±1.22dB (1) Power disturbance 30MHz~300MHz ±1.38dB (1) 30MHz~300MHz ±3.14dB (1) Radiation emission (3m) 300MHz~1000MHz ±3.18dB (1) (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. 4.7 Test Description 4.7.1 Description of Standards and Results EMISSION Description of Test Item Standard Results Conducted Emission Test Radiated Emission Test 47 CFR PART 15 OCT, 2014 ANSI C63.4-2009 47 CFR PART 15 OCT, 2014 ANSI C63.4-2009 N/A PASS Class B Report No.: CGZ3150202-00097-E Page 7 of 20

5 TEST CONDITIONS AND RESULTS 5.1 Power Line Conducted Emission Test For test instruments and accessories used see section 6 part 6.2. 5.1.1 Description of the test location Test location : Shielding Room 5.1.2 Description of the test set-up 5.1.2.1 Test procedure The EUT Power connected to the power mains through a line impedance stabilization network (L.I.S.N). This provides a 50 ohm coupling impedance for the EUT. Please refer the block diagram of the test setup and photographs. let EUT working in test mode, then test it. Both sides of AC line are checked to find out the maximum conducted emission. In order to find the maximum emission levels, the relative positions of equipment and all of the interface cables shall be changed according to FCC Part 15 on Conducted Emission Test. The frequency range from 150kHz to 30MHz is checked The EUT is normal during the test, and the results of the maximum emanation are recorded 5.1.2.2 Block Diagram of Test Setup Report No.: CGZ3150202-00097-E Page 8 of 20

5.1.3 Limits of disturbance (FCC Part 15 B Class B) Maximum RF Line Voltage Frequency Quasi-Peak Level db(μv) Average Level db(μv) 150kHz ~ 500kHz 66 ~ 56* 56 ~ 46* 500kHz ~ 5MHz 56 46 5MHz ~ 30MHz 60 50 Note: (1) The tighter limit shall apply at the edge between two frequency bands. 5.1.4 Test result The requirements are Band width Frequency range Min. limit margin Fulfilled 9kHz 0.15kHz - 30 MHz N/A Remarks: The EUT power supply by battery,not applicable. Report No.: CGZ3150202-00097-E Page 9 of 20

5.2 Radiated disturbance (Electric field) For test instruments and accessories used see section 6 part 6.1. 5.2.1 Description of the test location Test location : Semi-Anechoic chamber Test disturbance: 3 Meter 5.2.2 Description of the test set-up 5.2.2.1 Test procedure The EUT and its simulators are placed on a turn table, which is 0.8 meter high above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna, which is mounted on a antenna tower. The antenna can be moved up and down between 1 meter and 4 meters to find out the maximum emission level. Broadband antenna (calibrated bilog antenna) is used as receiving antenna. Both horizontal and vertical polarization of the antenna is set on Test. In order to find the maximum emission levels, all of the interface cables must be manipulated according to FCC Part 15 on radiated emission Test. The frequency range from 30MHz to 1000MHz and above 1GHz. is investigated. Please see the following pages. All measurements for radiated emissions within the restricted bands were performed using a Quasi- Peak detector with 120kHz RBW below 1GHz. All measurements for radiated emissions within the restricted bands were performed using a Quasi- Peak detector with 300kHz VBW below 1GHz. The EUT is normal during the test, and the results of the maximum emanation are recorded 5.2.2.2 Block Diagram of Test Setup Report No.: CGZ3150202-00097-E Page 10 of 20

5.2.3 Limits of disturbance (FCC Part 15 B Class B) Frequency Distance (Meters) (MHz) Field Strengths Limits (dbμv/m) 30 ~ 88 3 40 88 ~ 216 3 43.5 216 ~ 960 3 46 960 ~ 1000 3 54 Note: (1) The tighter limit shall apply at the edge between two frequency bands. (2) Distance refers to the distance in meters between the test instrument antenna and the closest point of any part of the E.U.T. 5.2.4 Test result The requirements are Band width Frequency range Min. limit margin Fulfilled 120kHz 30 MHz - 1000 MHz >7.69 db at 30MHz - 1000 MHz Remarks: The limits are kept. For detailed results, please see the following page(s). Report No.: CGZ3150202-00097-E Page 11 of 20

5.2.5 Test protocol Test point Operation mode Remarks: Horizontal Normal Result: - passed - not passed EUT Pro Trinket 5V Operating Condition Battery 5V Test Condition Ambient Temperature: 24 C Humidity: 56% Operator Clark MODEL NO. Pro Trinket 5V No. Frequency Factor Reading Level Limit Margin Det. (MHz) (db/m) (dbμv) (dbμv/m) (dbμv/m) (db) 1 30.0000-24.45 50.92 26.47 40.00-13.53 QP 2 75.4509-27.45 51.90 24.45 40.00-15.55 QP 3 141.4629-22.52 51.53 29.01 43.50-14.49 QP 4 191.2425-18.09 50.28 32.19 43.50-11.31 QP 5 256.1723-18.68 50.53 31.85 46.00-14.15 QP 6 295.6713-12.21 50.52 38.31 46.00-7.69 QP Report No.: CGZ3150202-00097-E Page 12 of 20

No. Frequency Factor Reading Level Limit Margin Det. (MHz) (db/m) (dbμv) (dbμv/m) (dbμv/m) (db) 1 335.0701-24.24 56.57 32.33 46.00-13.67 QP 2 486.5731-18.82 48.49 29.67 46.00-16.33 QP 3 629.6593-15.83 47.75 31.92 46.00-14.08 QP 4 768.5371-14.11 47.63 33.52 46.00-12.48 QP 5 880.7615-12.15 46.09 33.94 46.00-12.06 QP 6 914.4289-12.08 46.42 34.34 46.00-11.66 QP Report No.: CGZ3150202-00097-E Page 13 of 20

Test point Operation mode Remarks: Vertical Normal Result: - passed - not passed EUT Pro Trinket 5V Operating Condition Battery 5V Test Condition Ambient Temperature: 24 C Humidity: 56% Operator Clark MODEL NO. Pro Trinket 5V No. Frequency Factor Reading Level Limit Margin Det. (MHz) (db/m) (dbμv) (dbμv/m) (dbμv/m) (db) 1 30.5411-24.94 54.57 29.63 40.00-10.37 QP 2 75.4509-27.45 50.95 23.50 40.00-16.50 QP 3 142.0040-22.57 51.05 28.48 43.50-15.02 QP 4 189.6192-18.14 51.16 33.02 43.50-10.48 QP 5 258.3367-18.64 51.01 32.37 46.00-13.63 QP 6 297.8357-11.89 50.19 38.30 46.00-7.70 QP Report No.: CGZ3150202-00097-E Page 14 of 20

No. Frequency Factor Reading Level Limit Margin Det. (MHz) (db/m) (dbμv) (dbμv/m) (dbμv/m) (db) 1 357.5150-23.43 49.82 26.39 46.00-19.61 QP 2 479.5591-18.79 48.72 29.93 46.00-16.07 QP 3 619.8397-15.63 47.59 31.96 46.00-14.04 QP 4 764.3287-14.00 46.94 32.94 46.00-13.06 QP 5 890.5812-11.75 45.92 34.17 46.00-11.83 QP 6 922.8457-12.75 46.94 34.19 46.00-11.81 QP Note:Level=Reading+Factor. Margin= Level-Limit. Report No.: CGZ3150202-00097-E Page 15 of 20

6 USED TEST EQUIPMENT 6.1 Radiated disturbance (Electric field) Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 Signal analyzer ROHDE & SCHWARZ FSIQ26 100311 2014/03/25 2 EMI Test Receiver ROHDE & SCHWARZ ESVS 10 842885/001 2014/11/04 3 Biconical Antenna ROHDE & SCHWARZ HK116 100221 2014/03/30 4 Log per Antenna ROHDE & SCHWARZ HL223 100226 2014/03/30 5 Log per Antenna ROHDE & SCHWARZ HL050 100186 2014/03/30 6 Pre-Amplifier EMC EMC330 980113 2014/03/25 7 Pre-Amplifier EMC EMC012645 980114 2014/03/25 8 EMI Test Software Farad EZ-EMC N/A N/A 6.2 Conducted Disturbance Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 EMI Test Receiver ROHDE & SCHWARZ ESCI 100868 2014/11/04 2 Artificial Mains ROHDE & SCHWARZ ESH3-Z5 832479/025 2014/11/04 3 Artificial Mains ROHDE & SCHWARZ ESH3-Z5 100140 2014/11/04 4 Pulse Limiter ROHDE & SCHWARZ ESHS-Z2 100301 2014/11/04 5 EMI Test Software Farad EZ-EMC N/A N/A Report No.: CGZ3150202-00097-E Page 16 of 20

7 TEST PHOTOGRAPHS 7.1. Photo of radiated emission measurement (R.E.) Report No.: CGZ3150202-00097-E Page 17 of 20

8 External and Internal Photos of the EUT External view 1 External view 2 External view 3 Report No.: CGZ3150202-00097-E Page 18 of 20

External view 4 External view 5 External view 6 Report No.: CGZ3150202-00097-E Page 19 of 20

9 Normative references 1. 47 CFR PART 15 OCT, 2014 Radio Frequency Devices 2. ANSI C 63.4 : 2009 American National Standard for Methods of Measurement of Radio-Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9 khz to 40 GHz. 10 Manufacturer/ Approval holder Declaration The following identical model(s): N/A Belong to the tested device: Product description: Pro Trinket 5V Model name: Pro Trinket 5V Report No.: CGZ3150202-00097-E Page 20 of 20