CAMAG TLC VISUALIZER 2

Similar documents
OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

The Best Choice for Densitometric Evaluation of Planar Chromatograms

The Best Choice for Densitometric Evaluation of Planar Chromatograms

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Automated Imaging Technology to Simplify Your Workflow!

INGENIUS 3 LOW COST, HIGH PERFORMANCE GEL DOCUMENTATION AND ANALYSIS

INGENIUS 3. Low cost, high performance gel documentation and analysis

Chemiluminescence- and Fluorescence-Imager Celvin S

BIO IMAGING. Choose your application of STELLA 2000 STELLA 3200 STELLA BIO Image. light source. light source. light source.

BioSpectrum Imaging System

ChemiDoc-It Imaging System

CRISATEL High Resolution Multispectral System

Imaging Photometer and Colorimeter

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Imagers- Molecular, Cell Standard Operating Procedures

Systematic Workflow via Intuitive GUI. Easy operation accomplishes your goals faster than ever.

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Instrumental Thin-Layer Chromatography

ScrappiX. Visual inspection equipment for dimensional. and surface defects control

ULS24 Frequently Asked Questions

Ordering Information & Specifications. VisionWorksLS Capabilities. Image Analysis Capabilities

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

Image Capture TOTALLAB

High Resolution BSI Scientific CMOS

BioSpectrum Imaging System

Practical work no. 3: Confocal Live Cell Microscopy

Quantitative Hyperspectral Imaging Technique for Condition Assessment and Monitoring of Historical Documents

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

BaySpec SuperGamut OEM

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps

Camera Requirements For Precision Agriculture

Improving the Collection Efficiency of Raman Scattering

CHAPTER-V SUMMARY AND CONCLUSIONS

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Upgrade to Andor s high-resolution Luca EM R EMCCD; the new price/performance benchmark.

U GENIUS. Gel imaging at a touch

GEL IMAGING AT A TOUCH

Transilluminators: UV light, White light (WE-LED), Blue Light (BE-LED) Made in Germany Made by Herolab NEW

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Achieving 100,000 : 1 contrast measurement

Innovative measurement instruments from

Camera Requirements For Precision Agriculture

Bringing Answers to the Surface

U:GENIUS S Y N G E N E. Gel imaging at a touch A DIVISION OF THE SYNOPTICS GROUP

Product data sheet Palas Fidas 200 E

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

Seishi IKAMI* Takashi KOBAYASHI** Yasutake TANAKA* and Akira YAMAGUCHI* Abstract. 2. System configuration. 1. Introduction

AIXUV's Tools for EUV-Reflectometry Rainer Lebert, Christian Wies AIXUV GmbH, Steinbachstrasse 15, D Aachen, Germany

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

A 4 Megapixel camera with 6.5μm pixels, Prime BSI captures highly. event goes undetected.

Light Microscopy. Upon completion of this lecture, the student should be able to:

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

Thomas G. Cleary Building and Fire Research Laboratory National Institute of Standards and Technology Gaithersburg, MD U.S.A.

Characterization Microscope Nikon LV150

Leica TCS SP8 Quick Start Guide

Back-illuminated scientific CMOS camera. Datasheet

Photometric Measurements in the Field. Ronald B. Gibbons Group Leader, Lighting and Infrastructure Technology

Huvitz Digital Microscope HDS-5800

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps up to :1 up to 82 % pco. low noise high resolution high speed high dynamic range

Measuring intensity in watts rather than lumens

FUSION SOLO S CHEMILUMINESCENCE & OPTIONAL FLUORESCENCE IMAGING WESTERN BLOT IMAGING

How is the Digital Image Generated? Image Acquisition Devices

G BOX. Gel Documentation and Analysis Automated imaging

CS-2000/2000A. Spectroradiometer NEW

The End of Thresholds: Subwavelength Optical Linewidth Measurement Using the Flux-Area Technique

Optotop. 3D Topography. Roughness (Ra opt, Rq opt, and Rz opt) Height Distribution. Porosity Distribution. Effective Contact Area

transmission and reflection characteristics across the spectrum. 4. Neutral density

QUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology

THE CR SPECIALISTS HD-CR CR 35 NDT

NAME SECTION PERFORMANCE TASK # 3. Part I. Qualitative Relationships

746A27 Remote Sensing and GIS

Application Note. Digital Low-Light CMOS Camera. NOCTURN Camera: Optimized for Long-Range Observation in Low Light Conditions

BIG PIXELS VS. SMALL PIXELS THE OPTICAL BOTTLENECK. Gregory Hollows Edmund Optics

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Gel imaging at a touch S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP

LED Lighting Flux and Color Measurement System (LFC)

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

Problems in Color Proofing from the Colorimetric Point of View

T:GENIUS GEL IMAGING AT A TOUCH

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Practical Flatness Tech Note

Applications for cameras with CMOS-, CCD- and InGaAssensors. Jürgen Bretschneider AVT, 2014

Advanced 3D Optical Profiler using Grasshopper3 USB3 Vision camera

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

SER: Biological Stains Visualization with Alternate Light Sources

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Vandal Proof Camera: v-cam 500 (D-WDR, 650 TVL, Sony Effio-E, 0.05 lx) Vandal Proof Camera: v-cam 500 (D-WDR, 650 TVL, Sony Effio-E, 0.

COLOR CONTRAST AND LUMINESCENCE SENSORS

Optional AR coating and wedge windows are available

Optical basics for machine vision systems. Lars Fermum Chief instructor STEMMER IMAGING GmbH

ROAD TO THE BEST ALPR IMAGES

A DIVISION OF FORENSIC TECHNOLOGY SEE MORE. SOLVE MORE. CLASS-LEADING COMPARISON MICROSCOPES FOR FORENSIC INVESTIGATIONS

Transcription:

CAMAG TLC VISUALIZER 2 Professional Imaging and Documentation System for TLC/HPTLC Chromatograms with a new Digital CCD Camera, connected by USB 3.0 WORLD LEADER IN PLANAR CHROMATOGRAPHY

Visualization, Evaluation, and Archiving The visual presentation of the complete chromatogram showing all samples and standards side by side is one of the most convincing arguments for Thin-Layer Chromatography. No other chromatographic technique can directly express the result as a color image and make it available for visual evaluation. To reproducibly acquire and preserve best quality images of TLC/ HPTLC chromatograms under different illumination modes this high-end imaging and documentation system is now available. With its new digital CCD camera a maximum resolution of 82 µm on the plate is obtained. For electronic image acquisition the camera like the human eye captures polychromatic visible light. Under white light illumination it is the light reflected from the layer background. Under long-wavelength UV light (366 nm) it is the light emitted by fluorescent substances. When short-wavelength UV light (254 nm) is used, substances absorbing UV 254 nm appear as dark zones, provided the layer contains a fluorescence indicator (fluorescence quenching). Chromatogram under white light Chromatogram under UV 366 nm Chromatogram under UV 254 nm 2

Key Features Reproducible high-quality images acquired under homogenous illumination with the selected light Easy and intuitive operation with visioncats High-dynamic-range imaging (HDRI) Side by side comparison of tracks originating from the same or different plates and/or different illumination modes Various image enhancement tools, e.g. Spot Amplification, Clean Plate Correction and Exposure Normalization Image-based profile generation from reference and sample tracks, and subsequent peak integration and calibration New digital CCD camera with a maximum resolution of 82 µm on the plate USB 3.0 for easy PC connection Meets all requirements to be used in a cgmp/cglp environment IQ/OQ qualification and 21 CFR Part 11 ready CAMAG TLC Visualizer 2 3

CAMAG TLC Visualizer 2 operated under visioncats visioncats organizes the workflow of TLC/HPTLC, controls the involved CAMAG instruments, and manages data. Professional image acquisition and documentation of TLC/HPTLC chromatograms ensuring highest reproducibility is the major purpose of the TLC Visualizer 2. For the evaluation of acquired images sophisticated enhancement tools and functions for annotation and determination of position (R F ) are required. This is where visioncats comes into play and virtually unleashes the power of TLC/HPTLC. visioncats features a powerful database at its heart, enabling an all new sample-based approach. The state-of-the-art software supports low-noise, high-dynamicrange imaging (HDRI) and includes a comprehensive set of image enhancement tools. With the Comparison Viewer, tracks originating from the same or different plates and/or different illumination modes can be compared on the same screen side by side which allows the creation of virtual plates. Detailed on-screen instructions effectively guide the user through the image acquisition process. Data View allows for visual evaluation of a plate in different illumination modes and offers a broad range of helpful tools, e.g. the R F tool displays the R F value of zones on the digital image or a rectangular zoom function. Comparison Viewer : selected tracks of images taken from different plates under UV 366 nm, UV 254 nm, and white light can be displayed side by side. 4

Image Enhancement The image enhancement tools featured in visioncats exploit the full potential of the TLC Visualizer 2. Images are automatically captured based on an optimized control of the illumination and parameters specified in the TLC/HPTLC method. Sophisticated algorithms guarantee the highest image quality for identification of even the weakest zones. HDRI is a technique used to reproduce a greater dynamic range of luminance levels. Multiple standard-dynamic range images are taken at different exposures and merged into a single HDR image. For HDR images under UV 366 nm a set of dedicated enhancement tools is available. Exposure Normalization allows the retreatment of the image by normalizing the exposure: the gain is adjusted to an equivalent of 85% detector response based on a selected area (reference track by default). The tool is used to allow visual comparison of images from different plates with virtually the same exposure settings. The Clarify tool virtually changes the illumination setting after capturing and makes very faint zones visible on an unchanged background. Localization of even the smallest fractions on the plate can be achieved with the Spot Amp tool which allows increasing or decreasing the contrast of the image. With Clean Plate Correction an image taken of a neat plate prior to sample application can be subtracted from the image of the developed plate. Thus irregularities of the TLC/HPTLC plate, particularly the structure of the fluorescence indicator, or small variations in layer thickness seen in transmission mode, are efficiently eliminated. The Clean Plate Correction is significantly improved due to the increased resolution of the new CCD camera in the TLC Visualizer 2. Exposure Normalization for visualization of weak zones (right) and original image (left) Clean Plate Correction : the corrected image (right) is of superb quality. Due to reduced noise, weaker zones become detectable. CAMAG TLC Visualizer 2 5

Comparison Viewer The Comparison Viewer allows easy side by side comparison of tracks from different TLC/HPTLC plates and different detection modes on the same screen: from different plates same and/or different plates and/or detection modes to the Comparison Viewer, e.g. plate state (clean, developed, derivatized), wavelengths, R F value, and display settings track information and reference details to a different visioncats installation Comparison Viewer : creation of virtual plates from tracks originating from different plates and detection modes 6

Image-based evaluation visioncats software enables an image-based evaluation of chromatograms obtained with the CAMAG TLC Visualizer 2. Conversion of images of TLC/HPTLC chromatograms into analogue curves based on absorption or fluorescence of separated zones Integration of chromatograms resulting in semi-quantitative peak data (area and/or height) Semi-quantitative evaluation of samples in comparison to calibration standards on the same plate Profile Comparison Display of individual chromatograms Position of peaks (R F value / migration distance) can be determined Comparison of chromatograms from the same or different plate / image 3D-image profile Evaluation Intuitive data management Several calibration modes (e.g. single level, multi-level, related substances) Re-evaluation of data at any time Substance assignment Technical specifications Dimensions and weight Width: 480 mm, depth: 537 mm, height: 596 mm Net weight: 17.0 kg Object size supported With 12 mm lens: up to 20 x 20 cm With 16 mm lens: up to 20 x 10 cm Light sources 2 x UV tube short wavelength (254 nm) direct light 2 x UV tube long wavelength (366 nm) direct light 2 x white light tube direct light 2 x white light tube transmitted light Camera type Digital CCD camera, sensor SONY Super HAD CCD, HDR Camera exposure time 2.3 ms to 10 s, up to 60 s for HDRI, min. step size 1 µs Connection USB 3.0 and RS232 Mains voltage 100 240 V, 50 / 60 Hz, 50 W Software for instrument control visioncats (2.3 or higher) on MS Windows 7 and Windows 10 CAMAG TLC Visualizer 2 7

Sole Partner in China Find out more GZ +86 20 8329 2451 SH +86 21 6351 1828 HK +852 2569 2154 BJ +86 10 6527 8522 info@nikyang.com www.nikyang.com VISUALIZER 2 CM_Visualizer2_EN_1116