Downloaded from by on 02/07/18 from IP address Copyright ARRS. For personal use only; all rights reserved

Similar documents
Cardiac MR. Dr John Ridgway. Leeds Teaching Hospitals NHS Trust, UK

The SENSE Ghost: Field-of-View Restrictions for SENSE Imaging

3T Unlimited. ipat on MAGNETOM Allegra The Importance of ipat at 3T. medical

Pulse Sequence Design and Image Procedures

MRI Metal Artifact Reduction

1 Introduction. 2 The basic principles of NMR

ISSN X CODEN (USA): PCHHAX. The role of dual spin echo in increasing resolution in diffusion weighted imaging of brain

Clear delineation of optic radiation and very small vessels using phase difference enhanced imaging (PADRE)

BOLD fmri: signal source, data acquisition, and interpretation

MR Basics: Module 8 Image Quality

Works-in-Progress package Version 1.0. For the SIEMENS Magnetom. Installation and User s Guide NUMARIS/4VA21B. January 22, 2003

H 2 O and fat imaging

Magnetic Resonance Imaging Principles, Methods, and Techniques

Magnetic Resonance Imaging

Module 2. Artefacts and Imaging Optimisation for single shot methods. Content: Introduction. Phase error. Phase bandwidth. Chemical shift review

Simultaneous Multi-Slice (Slice Accelerated) Diffusion EPI

Noninvasive Blood Flow Mapping with Arterial Spin Labeling (ASL) Paul Kyu Han and Sung-Hong Park

2014 M.S. Cohen all rights reserved

MRI Summer Course Lab 2: Gradient Echo T1 & T2* Curves

Pulse Sequence Design Made Easier

HETERONUCLEAR IMAGING. Topics to be Discussed:

SIGNA Explorer Lift revives our MR

TimTX TrueShape. The parallel transmit architecture of the future. Answers for life.

Background (~EE369B)

MR Basics: Module 6 Pulse Sequences

High Field MRI: Technology, Applications, Safety, and Limitations

Passive Tracking Exploiting Local Signal Conservation: The White Marker Phenomenon

Advanced MSK MRI Protocols at 3.0T. Garry E. Gold, M.D. Associate Professor Department of Radiology Stanford University

Pulse Sequences: Rapid Gradient Echo

Liver imaging beyond expectations with Ingenia

Diffusion and Functional MRI of the Spinal Cord Methods and Clinical Applications

Image Quality/Artifacts Frequency (MHz)

Gradient Spoiling. Average balanced SSFP magnetization Reduce sensitivity to off-resonance. FFE, FISP, GRASS, GRE, FAST, Field Echo

Image quality evaluation of turbo-spin echo diffusion weighted image (TSE-DWI) : A phantom study

MR Advance Techniques. Flow Phenomena. Class II

Encoding of inductively measured k-space trajectories in MR raw data

NIH Public Access Author Manuscript Int J Cardiovasc Imaging. Author manuscript; available in PMC 2008 May 26.

Index COPYRIGHTED MATERIAL. Note: Page number followed by italics are for figures and bold are for tables, respectively.

Experience in implementing continuous arterial spin labeling on a commercial MR scanner

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

BACKGROUND. ** 78% of all MRI scanners have Image Quality problems. *** *** 25% of all Multi-Channel RF coils have at least one bad channel.

The Usefulness of Simultaneously Excited Magnetic Resonance Signals from Diffusion Tensor Image

High-Field Surface-Coil MR Imaging of Localized Anatomy

Transmit and Receive Transmission Line Arrays for 7 Tesla Parallel Imaging

Numerical Evaluation of an 8-element Phased Array Torso Coil for Magnetic Resonance Imaging

SYLLABUS. 1. Identification of Subject:

ACRIN 6686 / RTOG 0825

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Medical Images Analysis and Processing

Fast cine MRI of the orbit

PET/CT Instrumentation Basics

Ultrasound & Artifacts

Standards for Imaging Endpoints in Clinical Trials: Standardization and Optimization of Image Acquisitions: Magnetic Resonance

M R I Physics Course. Jerry Allison Ph.D., Chris Wright B.S., Tom Lavin B.S., Nathan Yanasak Ph.D. Department of Radiology Medical College of Georgia

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

The feasibility of breath-hold high-resolution 3D-MRCP obtained with 32 channel torso cardiac coil and T2-prepBTFE

functional MRI: A primer

Half-Pulse Excitation Pulse Design and the Artifact Evaluation

MRI Phase Mismapping Image Artifact Correction

Cover Page. The handle holds various files of this Leiden University dissertation

The development of the RF-pulse for the low level SAR used by the MRI.

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Improvement of the Image Quality of Black-blood Magnetic Resonance Imaging with the Subtraction Double Inversion Recovery Technique

Supplementary Figure 1

Improving high-field MRI using parallel excitation

MAGNETIC RESONANCE IMAGING

MRI Systems and Coil Technology

Principles of MRI EE225E / BIO265. Lecture 21. Instructor: Miki Lustig UC Berkeley, EECS. M. Lustig, EECS UC Berkeley

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Challenges of Field Inhomogeneities and a Method for Compensation. Angela Lynn Styczynski Snyder. Michael Garwood, Ph.D., Adviser

(N)MR Imaging. Lab Course Script. FMP PhD Autumn School. Location: C81, MRI Lab B0.03 (basement) Instructor: Leif Schröder. Date: November 3rd, 2010

k y 2k y,max k x 2k x,max

Fast Field-Cycling Magnetic Resonance Imaging (FFC-MRI)

Four-dimensional Computed Tomography (4D CT) Concepts and Preliminary Development

MRI Anatomy and Positioning Series Module 12: Fat Suppression Techniques

Low-Cost MR-Compatible Moving Heart Phantom

Ultrafast Imaging: Principles, Pitfalls, Solutions, and Applications

SNR and functional sensitivity of BOLD and perfusion-based fmri using arterial spin labeling with spiral SENSE at 3 T

System/Imaging Imperfections

Development of a 1.0 T MR microscope using a Nd-Fe-B permanent magnet

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

Receive Arrays and Circuitry

Photomultiplier Tube

Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging

Diagonal-SPRITE and Its Applications for In Vivo Imaging at High Field

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

MR in RTP. MR Data for Treatment Planning: Spatial Accuracy Issues, Protocol Optimization, and Applications (Preview of TG117 Report) Acknowledgements

Application Guide & Release Notes

MR in Tx Planning. Acknowledgements. Outline. Overview MR in RTP

SIEMENS MAGNETOM Skyra syngo MR D13

COMPUTED TOMOGRAPHY 1

Fundamental and Clinical Studies for Effectiveness of Zero-filling Interpolation on k-space for Improvement of Sharpness in Magnetic Resonance Imaging

Delivering Better Patient Care with SIGNA Architect

RAD 229: MRI Signals and Sequences

MRI SYSTEM COMPONENTS Module One

2015 Spin echoes and projection imaging

Focused RF Hyperthermia Using Ultra-High Field MRI Joshua de Bever, PhD

GE Healthcare. Discovery MR T. Simply powerful. Powerfully simple.

Artifacts. Artifacts. Causes. Imaging assumptions. Common terms used to describe US images. Common terms used to describe US images

25 CP Generalize Concepts in Abstract Multi-dimensional Image Model Component Semantics Page 1

Transcription:

Downloaded from www.ajronline.org by 46.3.192.5 on 02/07/18 from IP address 46.3.192.5. Copyright RRS. For personal use only; all rights reserved C oil sensitivity encoding (SENSE) is a new technique that considerably enhances MR imaging. This technique allows a reduction in scan time in any imaging mode through the use of multiple receiver coils [1]. We have used the technique in clinical practice, especially in body imaging, on 1000 patients for more than a year. On the basis of our initial experience, we summarize the image quality and applications of the SENSE technique for body imaging, focusing on its advantages and disadvantages. Coil Sensitivity Encoding in MR Imaging: dvantages and Disadvantages in Clinical Practice Yasuyuki Kurihara 1, Yoshiko K. Yakushiji 1, Ichiro Tani 1, Yasuo Nakajima 1, Marc Van Cauteren 2 SENSE Imaging Procedure ll studies were performed on a Gyroscan CS-NT15 scanner (Philips, est, The Netherlands) equipped with a Syncra4 SENSE research software patch (Philips). ll images were taken using a Synergy body coil (Philips), which has four individual coil elements and preamplifiers. MR imaging with the SENSE technique requires the following steps. First, for a reliable sensitivity mapping of each coil element, a reference measurement scan is obtained using the coils and related images acquired with the homogeneous quadrature body coil. In our preliminary clinical research setup, the reference scan was a fast field-echo sequence (TR/TE, 8.9/05.; flip angle, 8 ; matrix, 32 64 64; excitations, 9; scan time, 1 min 4 sec). Second, SENSE data are acquired with a reduced number of phase-encoding steps resulting in an aliased or back-folded image with a reduced field of view (Fig. 1). Scan time is reduced by decreasing the number of phase-encoding steps. This reduction is defined by the SENSE reduction factor R (the SENSE scan time equals the full scan time divided by R). Third, in the SENSE technique, unlike phased array coils, the coil elements are not used to cover separate anatomic regions to increase the signal-to-noise ratio (SNR) but are used to simultaneously measure the same region for scan-speed increase. The SENSE reconstruction algorithm separates the superimposed signals using information on the individual coil sensitivities and restores the full field-ofview image (Fig. 1). Fast Imaging Fast imaging is an essential function of the SENSE technique. reduction in scan time can minimize image quality deterioration due to respiratory motion or bowel peristalsis and therefore can improve the image quality (Fig. 2). In a dynamic study, temporal resolution is dramatically improved with the SENSE technique. If there is no need to reduce the scan time, the SENSE technique can provide improved Technical Innovation spatial resolution and an increased number of slices. In three-dimensional Fourier transformation reconstruction, phase-encoding steps are performed along the normal phase-encoding direction and also along the slice-selection direction. Therefore, the SENSE technique can be applied in both directions and can result in a further speeding up of data acquisition. The SENSE reduction factor in both directions (phase and slice) can be set to 2, resulting in an overall SENSE reduction factor of 4 (2 2). This technique is useful for gadolinium-enhanced MR angiography (Fig. 3). Improved SNR with Longer TR Ultrashort (2 4 msec) TR is frequently used for advanced gadolinium-enhanced MR angiography, providing high temporal and spatial resolution but with a decreased SNR. In this situation, a bolus injection of contrast agent is needed to achieve a high-signal level. The SENSE technique is another choice for improved SNR (Fig. 4). If there is no need to further reduce the scan time, a longer TR combined with SENSE can be chosen (e.g., using a TR twice as long and a SENSE reduction factor of 2). This procedure results in an increase of SNR (typically more than 40%) for the same scan time. There are two reasons for Received May 29, 2001; accepted after revision November 15, 2001. 1 Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-Ku, Kawasaki City, Kanagawa, 216-8511, Japan. ddress correspondence to Y. Kurihara. 2 Philips Medical Systems Corporation, Philips ldg., 13-37 Kohnan 2-chome Minato-Ku, Tokyo, 108, Japan. JR 2002;178:1087 1091 0361 803X/02/1785 1087 merican Roentgen Ray Society JR:178, May 2002 1087

Downloaded from www.ajronline.org by 46.3.192.5 on 02/07/18 from IP address 46.3.192.5. Copyright RRS. For personal use only; all rights reserved Kurihara et al. Fig. 1. Coil sensitivity encoding (SENSE) procedure in MR imaging., Conventional Fourier transformation produces fewer phase encoding steps (R factor, 2) and results in reduction of field of view, causing typical foldover or aliasing artifact., SENSE reconstruction algorithm separates superimposed signals using information on individual coil sensitivities and restores full field-of-view image. R factor = SENSE reduction factor. this increase in SNR [2, 3]. First, the acquisition bandwidth is lower, resulting in a higher SNR. Second, the longer TR causes further T1 relaxation to a higher steady-state level, again resulting in an increase in the SNR. Correction of the Heterogeneous Sensitivity of the Coils synergy coil or phased array coil is composed of multiple surface coils. This results in a difference in intensity on an image because of the heterogeneous sensitivity of each coil. The SENSE technique uses the coil sensitivity, measured with a reference scan, to make the final image intensity completely homogeneous. This technique not only provides us with a correction of the heterogeneous sensitivity of each surface coil, but also with a wider field of view without decreasing the signal intensity at the periphery of the coils (Fig. 5). Effects Due To the Decrease in EchoTrain Length SENSE may be used to reduce the length of the echo train by decreasing the number of phase-encoding steps, improving the image quality. In turbo spin-echo sequences, a decreased echo-train length or reduced turbo factor results in suppression of the strong fat intensity with J-coupling effects (Fig. 6), improvement in SNR by avoiding the sampling of weak signals in the latter part of the echo train, improvement in contrast material within soft tissue, and reduction of T2 blurring due to the diminished T2 filtering effect. In echoplanar imaging, decreased echotrain length or reduced echoplanar imaging factor causes two effects. The first effect involves a decrease in the chemical shift artifact along the phase direction that arises because of the accumulation of phase shift during sequential phase-encoding steps, of which the number is reduced in SENSE. The second effect involves a decrease in the susceptibility artifact due to reduced phase accumulation from the dephasing in field inhomogeneities [4, 5]. Decreased Specific bsorption Rate SENSE may be used to reduce the number of radiofrequency pulses or to slow the switching of gradients, resulting in a smaller specific absorption rate and reduced neurostimulation. SNR s in all images, the SNR of SENSE images is proportional to the square root of the acquisition time. Therefore, when a SENSE reduction factor of R is applied, the overall SNR of the SENSE image reduces by one divided by the square root (R). Furthermore, in Fig. 2. 49-year-old woman with ovarian cysts., T2-weighted sagittal spin-echo MR image (TR/TE, 3500/1100) shows blurred bowel tract and muscle (arrows) due to respiratory motion and bowel peristalsis. Scan time for 15 slices was 1 min 35 sec., T2-weighted sagittal spin-echo MR image (3500/1100) using coil sensitivity encoding (R factor, 2) shows anatomic structures (arrows) more clearly than because of suppression of motion artifact. Scan time for 15 slices was 53 sec. 1088 JR:178, May 2002

Downloaded from www.ajronline.org by 46.3.192.5 on 02/07/18 from IP address 46.3.192.5. Copyright RRS. For personal use only; all rights reserved Coil Sensitivity Encoding in MR Imaging C D Fig. 3. 61-year-old woman with Takayasu s arteritis. D, High-resolution contrast-enhanced MR angiography carotid images (TR/TE, 4.0/1.0) using two-dimensional coil sensitivity encoding technique (R factor, 4) provide high temporal-resolution dynamic study. Maximum-intensity-projection angiograms from three-dimensional volumes are shown acquired at 8 (), 12 (), 16 (C), and 20 sec (D) after injection of gadolinium-enhanced contrast agent. Field of view is 529 529 mm. Each maximum-intensity-projection image is reconstructed with 24 slices of source images. Fig. 4. 35-year-old man with intralobar sequestration. High-resolution pulmonary MR angiogram using two times longer TR (8 msec) and coil sensitivity encoding (R factor, 2) shows perfusion defect in left lower lobe due to intralobar sequestration. Note increased signals from lung parenchyma because of longer T1 recovery. SENSE, additional noise appears when the geometric relations of the coil sensitivities are not ideal [1]. This specific effect is quantitatively described by the local geometric factor g. The local SNR of a SENSE image is then given by JR:178, May 2002 Fig. 5. 49-year-old woman with cervical carcinoma of uterus., T2-weighted sagittal spin-echo MR image (TR/TE, 3500/1100) shows decreased signal intensity in marginal areas of field of view (arrows)., T2-weighted sagittal spin-echo MR image (3500/1100) using coil sensitivity encoding (R factor, 2) shows uniform intensity of image (arrows). SNR sense = SNR full / g R. The geometric factor describes the ability to separate pixels superimposed by aliasing with the coil configuration used. Note that g varies over the image. The g is always greater than 1 and is higher when multiple aliasing occurs. If the SENSE reduction factor is less than 2.5, the geometry factor is usually less than 1.1 and is, in practice, negligible. 1089

Kurihara et al. Downloaded from www.ajronline.org by 46.3.192.5 on 02/07/18 from IP address 46.3.192.5. Copyright RRS. For personal use only; all rights reserved Fig. 6. 27-year-old healthy male volunteer., T2-weighted axial spin-echo MR image (TR/TE, 3000/120; turbo factor, 13) results in strong fat intensity with J-coupling effects., Coil sensitivity encoding image (R factor, 2) with same TR/TE as, turbo factor of 7, and longer echo spacing shows suppression of bright fat signal. Fig. 7. 71-year-old woman with adrenal mass. bdominal gradient-echo MR image (TR/TE, 215/2.3) using coil sensitivity encoding (SENSE) (R factor, 2) shows residual bright fat signal (large arrow) and split-line artifact (small arrows), which causes jump-up intensity at mid portion. oth rare artifacts could be caused by mismatch between reference scan and SENSE data acquisition. Fig. 8. 45-year-old man with liver cirrhosis., liasing image before coil sensitivity encoding (SENSE) reconstruction algorithm shows foldover beyond midline of field of view because of small field-of-view setting., SENSE reconstructed images (TR/TE, 520/20; flip angle, 20 ; R factor, 2) shows remaining folded areas (arrows). 1090 JR:178, May 2002

Coil Sensitivity Encoding in MR Imaging Downloaded from www.ajronline.org by 46.3.192.5 on 02/07/18 from IP address 46.3.192.5. Copyright RRS. For personal use only; all rights reserved rtifacts Most of the artifacts associated with SENSE images are caused by a mismatch between the reference scan and the SENSE data acquisition (Fig. 7). These mismatches can be caused by the respiratory pattern, local susceptibility, strong fat signal, or voxel size. ctually, the artifacts are hardly visible in most practical clinical scans because of optimizing of the voxel size and breathing pattern and adjusting the reference scan so that susceptibility has a minimal influence. Erroneous Field-of-View Setting If the field-of-view setting is too small for SENSE imaging acquisition, folded areas partially persist on the mid portion of SENSE reconstructed images (Fig. 8). In SENSE, with a reduction factor of 2, foldover beyond the mid line of the field of view cannot be unfolded. This is not an artifact but a mistake in the fieldof-view setting. SENSE is a powerful and promising technique for fast MR imaging for any sequence of body imaging. dvantages of SENSE are based on not only the reduction in total scan time, but also on the increased flexibility of parameters and the improved image quality because of the reduction in echo-train length. rtifacts and decreased image quality usually result from a suboptimal reference scan and coil setup. However, these disadvantageous effects occur rarely in most daily examinations in clinical practice. References 1. Pruessmann KP, Weiger M, Scheidegger M, oesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999;42:952 962 2. Weiger M, Pruessmann KP, Kassner, et al. Contrast-enhanced 3D MR using SENSE. J Magn Reson Imaging 2000;12:671 677 3. Parker DL, Goodrich KC, lexander L, uswell HR, latter DD, Tsuruda JS. Optimized visualization of vessels in contrast enhanced intracranial MR angiography. Magn Reson Med 1998;40:873 882 4. Golay X, Prussmann KP, Weiger M, et al. PRESTO- SENSE: an ultrafast whole-brain fmri technique. Magn Reson Med 2000;43:779 786 5. Pruessmann KP, Weiger M, Muiswinkel MC, oesiger P. Sensitivity encoding for single-shot diffusion imaging. In: Proceedings of 7th annual scientific meeting of the International Society for Magnetic Resonance in Medicine. erkley, C: ISMRM, 1999(P):1815 JR:178, May 2002 1091