CZT Technology: Fundamentals and Applications

Similar documents
CHAPTER 8 GENERIC PERFORMANCE MEASURES

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

NM Module Section 2 6 th Edition Christian, Ch. 3

GE Healthcare. Vivid S5. Cardiovascular ultrasound system

LaBr 3 :Ce, the latest crystal for nuclear medicine

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

GE Healthcare. Senographe Crystal The choice is crystal clear

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Electronic Instrumentation for Radiation Detection Systems

Industry Breakthrough

Industry Breakthrough

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Ergo TM Imaging System

Scintillation Counters

Photomultiplier Tube

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

Future directions in Nuclear Medicine Instrumentation

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

GE Healthcare. Senographe Crystal The choice is crystal clear

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

GE Healthcare. Essential for life. Senographe Essential Full-Field Digital Mammography system

GE Healthcare. 9100c. Familiar. Reliable. Affordable.

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Gamma Spectrometer Initial Project Proposal

Pinhole collimator design for nuclear survey system

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

Changing the Shape of Nuclear Medicine

COMPUTED TOMOGRAPHY 1

Performance characterization of a novel thin position-sensitive avalanche photodiode-based detector for high resolution PET

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy

ORTEC Experiment 3. Gamma-Ray Spectroscopy Using NaI(Tl) Equipment Required. Purpose. Gamma Emission

The Light Amplifier Concept

Vivid S5. Cardiovascular ultrasound system. GE Healthcare. Davis Medical

New Technology in Nuclear Medicine

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

Primer on molecular imaging technology

2010 Philips BrightView XCT SPECT/CT

First Applications of the YAPPET Small Animal Scanner

XRF Instrumentation. Introduction to spectrometer

Simulation and evaluation of a cost-effective high-performance brain PET scanner.

High collection efficiency MCPs for photon counting detectors

From the beginning of radionuclide imaging, there has. Recent Advances in SPECT Imaging. RECENT ADVANCES IN SPECT IMAGING Madsen 661. Mark T.

PMT Calibration in the XENON 1T Demonstrator. Abstract

How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram?

Parameters Affecting on Intrinsic Uniformity Test For MEDISO

Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET

Charge Loss Between Contacts Of CdZnTe Pixel Detectors

Journal of Radiation Protection and Research

A new operative gamma camera for Sentinel Lymph Node procedure

A high energy gamma camera using a multiple hole collimator

5. Scintillation counters

5. Scintillation counters

Data. microcat +SPECT

Spectrophotometer. An instrument used to make absorbance, transmittance or emission measurements is known as a spectrophotometer :

Lunar Technology Advantages

Advanced Materials Research Vol

Compact design. Clinical versatility.

Chemical Engineering 412

Robert Pagnanelli BSRT(R)(N), CNMT, NCT, FASNC Chief Technologist, Nuclear Imaging Duke University Medical Center. Thursday September 8, 2011

Development of an innovative LSO-SiPM detector module for high-performance Positron Emission Tomography

2/14/2019. Nuclear Medicine Artifacts. Symmetric energy windows

Atomic and Nuclear Physics

GE Healthcare. Performa. High-performance breast imaging

COMPTON SCATTERING. Purpose. Introduction. Fundamentals of Experiment

Performance evaluation of two CZT gamma ray imaging systems

PD233: Design of Biomedical Devices and Systems

(12) Patent Application Publication (10) Pub. No.: US 2004/ A1

CHAPTER 7 MEDICINE IMAGING DEVICES

GE Healthcare. Senographe 2000D Full-field digital mammography system

Intrinsic and Tomographic Evaluation of Siemens e.cam SPECT System at the Korle-Bu Teaching Hospital (Ghana)

CARING DESIGN. PRACTICAL TECHNOLOGY.

Charge Sharing Effect on 600 µm Pitch Pixelated CZT Detector for Imaging Applications *

Components of Optical Instruments

X-rays in medical diagnostics

Advancement in development of photomultipliers dedicated to new scintillators studies.

Chapter 2 Solid-State Detectors for Small-Animal Imaging

Title detector with operating temperature.

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

Design Optimization of a Small-animal SPECT System Using LGSO Continuous Crystals and Micro Parallel-hole Collimators

Characterization of photon counting CZT detectors for medical x-ray imaging and spectroscopy

SECONDARY ELECTRON DETECTION

THE increasing interest on pinhole collimation of gamma

Investigation of Multiple Head Registration / Center of Rotation for SPECT Gamma Cameras

Photons and solid state detection

Gamma-ray spectral imaging using a single-shutter radiation camera

Explain what is meant by a photon and state one of its main properties [2]

APD Quantum Efficiency

Production of HPDs for the LHCb RICH Detectors

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

Week 9: Chap.13 Other Semiconductor Material

Chapter 2. Detectors for Small-Animal SPECT I Overview of Technologies. 1. Introduction. Harrison H. Barrett and William C. J.

Initial Certification

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Dynamic Range. Can I look at bright and faint things at the same time?

TOWARDS SIMULTANEOUS SINGLE EMISSION MICROSCOPY AND MAGNETIC RESONANCE IMAGING LIANG CAI DISSERTATION. Urbana, Illinois

Exprerimental Evaluation of a Dedicated Pinhole SPECT System for Small Animal Imaging and Scintimammography

Inveon. No Limits on Discovery.

Transcription:

GE Healthcare CZT Technology: Fundamentals and Applications White Paper

Abstract Nuclear Medicine traces its technology roots to the 1950 s, and while it has continued to evolve since the invention of the Anger camera, the underlying principle of operation of the detector has not changed during this time, and this has set limits on the performance that can be obtained with a gamma camera. The commercial availability of CZT (Cadmium Zinc Telluride) detectors has allowed gamma camera designers to challenge many of the traditional design constraints, and the result is a new generation of Nuclear Medicine equipment with previously unheard-of performance and clinical utility. What is CZT CZT is shorthand for Cadmium Zinc Telluride a direct conversion semiconductor with a density of~5.8 g/cm 3. Its density and high effective atomic number (Z eff ~50) give it high stopping power for typical energies of interest in SPECT with a linear attenuation coefficient greater than that of NaI, for example. The zinc content varies from supplier to supplier, but a typical composition is Cd (1-x) Zn x Te with x around 0.1. It often contains trace amounts of other elements (dopants) that are used to improve the electrical properties. CZT is grown as a single crystal at a temperature of around 1100C in a hermetically sealed container to prevent chemical contamination. The crystal (known as boule ) is cut into wafers, polished, and metal contacts are deposited on the surface to extract the electrical signals from the detector. Finally it is bonded to electronics, and becomes a complete miniature detector. Comparison of stopping power 1000 Comparison with Anger camera In a typical scintillator-based gamma camera, incident gamma rays deposit their energy in the scintillator where it is converted into visible (or near-uv) light photons. The number of photons generated varies with scintillator, but for NaI:Tl (thallium-doped sodium iodide, the standard scintillator for Anger cameras) the conversion rate is typically 38 photons/kev; thus, the 140 kev emission from 99m Tc produces about 5300 photons. Two-thirds of these photons reach the photocathode of a photomultiplier (PMT), where about 25% of them are converted to photoelectrons. These photoelectrons are amplified by the PMT and turned into an electrical pulse with amplitude proportional to the deposited energy. The amplitude of the electrical signal observed for the same energy deposited is affected by many factors: variation in number of photons generated, variation in number of photons transported to the photocathode (depends on depth of interaction), variations in conversion efficiency of the photocathode, variations in the amplification properties of the PMT dynodes, and statistical fluctuations (Poisson noise); the latter is probably the most significant. By contrast, in a direct conversion detector like a CZT attenuation (/cm) 100 10 1 CZT Nal the radiation deposits energy at some point in the crystal lattice where it results in the generation of pairs of charge carriers. By application of an electric field the charge carriers get swept to the cathode and anode of the device where they induce a current pulse that can be detected. The energy resolution for either detector is ultimately limited by Poisson statistics: the FWHM energy resolution can be no better than 2.355/sqrt(N), which sets a limit of 7% FWHM on NaI at 140 0.1 10 100 1000 energy (kev) kev (with about 1000 UV photons detected) but less than 1.5% FWHM for CZT (with over 30,000 electric charges detected). Linear attenuation coefficient of NaI and CZT showing that the latter has greater stopping power at these energies

collimator detector electronics shielding collimator scintillator lightguide PMTS electronics shielding dead space By comparison, in CZT a compact charge cloud is detected by a segmented anode that is only millimeters away and an improvement in resolution can be obtained simply by making the anode pixels smaller and increasing the number of electronic channels. The practical limit on resolution, then, is given by the limits on the density of the electronics, and the associated power dissipation and cost; but detectors have already been successfully produced with 0.6 mm pixels for certain astrophysical experiments, showing that the practical limit on resolution is still some ways off. System tradeoffs In practice the resolution obtained with NaI detectors is a little closer to the theoretical value (10% vs 7%) than for CZT (6% vs 1.5%). This reflects the many years of technical evolution of NaI detectors which has brought their performance close to the theoretical best; while for CZT detectors, there is still room for further improvement. Dead space One of the most striking things about the CZT detector is its size. Specifically, in an Anger camera it is difficult to resolve the position of events beyond the center of the last (edge) PMT. This results in a significant dead space all around the detector; the CZT detector, being direct-conversion based, has no such dead space. A CZT-based detector is also much thinner than an Anger camera since it contains no light guide or photomultiplier. The consequence of this is that the volume that needs to be shielded is much smaller for a CZT-based detector, which in turn means that the final assembly will be much lighter. Intrinsic spatial resolution The spatial resolution of today s CZT detectors is 2.5 mm independent of energy a lot better than the 4.0 mm typically achieved with NaI at 99m Tc energies (140 kev), and much better again than the resolution obtained with 201 Tl (5 6 mm). The reason is that the photons in a NaI crystal are diffused over a considerable distance before being detected, and the triangulation to their origin is done with PMTs that are several centimeters away from the location of radiation interaction. The detector of a gamma camera is often considered separate from the collimator, yet the one cannot function without the other. For example, intrinsic resolution of a detector is an almost meaningless parameter unless considered in conjunction with the corresponding resolution in the collimator; similarly, sensitivity of a collimator does not matter unless the stopping power of the detector is taken into account. With this in mind, it is helpful to consider what is needed from a gamma camera system, and then work back to the detector requirements. Ultimately, the goal of the gamma camera is to create an accurate representation of activity distribution in a body. Given the physics of nuclear medicine, this can be broken down into five fundamental requirements: Sensitivity: get lots of counts Resolution: where did they come from? Field of view: am I looking at the right part of the patient? Scatter & photopeak crosstalk rejection/correction: are these events what I think they are? Attenuation correction: what am I missing? The first three of these requirements are subject to system trade-offs; the last two are patient dependent. The best-known of these trade-offs is between sensitivity and resolution: a high-resolution collimator views a very narrow column of activity from the patient, and therefore provides excellent spatial resolution at the expense of sensitivity. A high sensitivity collimator by contrast accepts radiation from a wider range of angles; this increases the sensitivity at the expense of resolution.

Figure 1a:- Resolution Sensitivity High resolution, low sensitivity Low resolution, high sensitivity It is also possible to get more sensitivity by sacrificing field of view Resolution and sensitivity are important, but they are not the only things that matter. The fourth requirement addresses the question of scatter rejection and the rejection of photopeak crosstalk for multi-isotope imaging. These are achieved with good energy resolution in the detector. For an isotope with a single photopeak, like 99m Tc, it has been shown that image quality improves until energy resolution of the detector reaches about 5%. At this resolution, image quality is improved without the need for scatter correction. Patient distance Figure 1b:- Detector surface Sensitivity or by increasing the total detector area, as is shown in the diagram. Detector All other things being equal, a high-resolution collimator (LEHR) will have lower sensitivity than a general-purpose collimator (LEGP). However, image quality obtained with a LEGP collimator may well be better than the quality obtained with a LEHR collimator in the case where the latter is further from the patient. The following graphs demonstrate that the resolution of the system depends on the intrinsic resolution when the object is close to the collimator, but is dominated by the collimator at source distances greater than a few centimeters. For intrinsic resolution we compare typical values for intrinsic resolution of 4 mm (general purpose NaI based camera) and 2 mm (CZT). 16 14 12 Parallel hole SPECT Detector Resolution (mm) 10 8 6 4 2 LEGP LEHR LEGP-2mm 0 0 50 100 150 Distance (mm) 200 250 System resolution degrades with object distance more so for high sensitivity collimators. Intrinsic detector resolution hardly affects resolution at larger distance. Figure 1c:- Field of View Two smaller detectors Sensitivity In the figure we plot system resolution as a function of object distance for three cases: LEGP (Low Energy General Purpose) collimator with 4 mm detector resolution; the same collimator with 2 mm detector resolution; and a LEHR (Low Energy High Resolution) collimator with a 4 mm resolution detector.

It can be seen that a high sensitivity collimator can outperform a high-resolution collimator when it is closer to the patient. The same is true even when the intrinsic resolution of one system is higher than that of another system: imaging performance comes about as a result of the interaction of all these factors, and imaging performance can be optimized only by taking a system approach. NaI At this point it is worth mentioning that recent advances in image reconstruction techniques using PSF (point spread function) modeling allow the reconstruction of images with higher resolution than is suggested by these curves; but even with these algorithms there is no free lunch and for equal count statistics the image quality obtained with higher resolution collimators will be superior. Energy Resolution The primary reason for wanting good energy resolution in a gamma camera is that it gives the camera the ability to distinguish scattered from unscattered radiation. The better the energy resolution, the narrower the acceptance window can be, and thus the smaller the fraction of scattered events that is accepted into the imaging window. The additional image quality benefit that can be obtained once energy resolution drops below 5% FWHM is small. However, when more than one photopeak is imaged at the same time whether because the isotope has multiple emission peaks or because the patient is being imaged simultaneously with multiple isotopes energy resolution improvements below 5% are still worthwhile as the degree of crosstalk diminishes linearly with window width. This is an exciting area of ongoing research for CZT-based gamma cameras. CZT As was mentioned above, dual isotope imaging is one of the most promising applications of CZT technology. We reproduce here the spectrum obtained with a conventional gamma camera viewing a mixture of 99m Tc and 123 I, and a second spectrum of the same mixture obtained with a CZT detector. It is clear that in the CZT spectrum there is much less down-scatter from the 159 kev peak into the 140 kev window. Because there is less overlap between the peaks with the CZT detector, the correction that has to be applied to remove the downscatter is quite small; this in turn means that this correction will add little noise, and that the bias in the final image will be small. Overlay of 99m Tc and 123 I spectra, showing greater crosstalk between the two peaks for the NaI detector with its poorer energy resolution and wider energy window. Application of CZT in GE systems At this point GE sells four different imaging systems based on CZT technology, while a fifth system is in the research phase. A quick look at these designs highlights some of the strengths of the CZT material as a gamma ray detector.

Pre-clinical SPECT The first two systems are our preclinical SPECT imagers the explore speczt and Triumph X-SPECT. The explore speczt consists of a ring of 40 CZT detectors that are tightly packed all around the object of interest. The detectors are fixed but a set of slit-slat or pinhole collimators on a cylinder can rotate to give multiple views of the object. This system design follows all the principles outlined above: it leverages the high intrinsic resolution of the CZT in order to get excellent spatial resolution in the system, and takes advantage of the low dead space in order to maximize the amount of detector coverage all around the subject. The result is a system with high sensitivity over a large field of view this is particularly useful for dynamic whole-body imaging in small animals. Alcyone Technology The third and fourth GE systems to use CZT detectors are the Discovery NM 530c and Discovery NM/CT 570c with Alcyone Technology dedicated cardiac cameras. The principle here is to get many detectors as close to the heart as possible in order to be able to image the heart without detector motion. Once again, the key characteristics of CZT that make this possible are the excellent intrinsic resolution (which permits the use of pinholes in the minifying configuration) and low dead space, which allows close packing of detectors. The energy resolution of the detectors is also good enough for the potential of simultaneous imaging of 123 I and 99m Tc labeled agents which can be expected to lead to the development of more efficient imaging protocols and greater diagnostic accuracy. Configuration of the detectors in the Alcyone system, showing how multiple detectors view the heart at the same time from different angles for high system sensitivity. Molecular Breast Imaging: MBI Diagram of preclinical SPECT scanner showing tight arrangement of detector modules and slit-slat (left) or multi-pinhole (right) collimator The fifth and final example of the use of CZT involves a research effort into a system that could be capable of doing Molecular Breast Imaging. For breast imaging, spatial resolution and dead space are the key factors. With the compact form factor and minimal dead space of the CZT detector it is possible to make a gamma camera that can be positioned close to the patient, with potential for both Cranio-caudal and Mediolateral-oblique views. At the same time, the smaller size could make the camera less intimidating for the patient. Further, since the detector can get so close to the breast, the collimator can be kept short, resulting in high

sensitivity without sacrificing resolution. While more clinical evidence is needed, initial work with prototypes has shown great promise for providing additional diagnostic information especially for women with dense breasts. Conclusions CZT detectors have reached a level of maturity that permits their use in specific applications that take advantage of their unique properties: high spatial resolution, low dead space, and excellent energy resolution. Over the next few years further developments in detector technology can be expected to lead to additional improvements in performance. CZT technology will lead to a major transformation in the practice of Nuclear Medicine.

2010 General Electric Company All rights reserved. GE, GE Monogram and Discovery are trademarks of General Electric Company. GE Healthcare, a division of General Electric Company. General Electric Company reserves the right to make changes in specification and features shown herein, or discontinue the product described at any time without notice or obligation. About GE Healthcare GE Healthcare provides transformational medical technologies and services that are shaping a new age of patient care. Our broad expertise in medical imaging and information technologies, medical diagnostics, patient monitoring systems, drug discovery, biopharmaceutical manufacturing technologies, performance improvement and performance solutions services help our customers to deliver better care to more people around the world at a lower cost. In addition, we partner with healthcare leaders, striving to leverage the global policy change necessary to implement a successful shift to sustainable healthcare systems. Our healthymagination vision for the future invites the world to join us on our journey as we continuously develop innovations focused on reducing costs, increasing access and improving quality and efficiency around the world. Headquartered in the United Kingdom, GE Healthcare is a $16 billion unit of General Electric Company (NYSE: GE). Worldwide, GE Healthcare employs more than 46,000 people committed to serving healthcare professionals and their patients in more than 100 countries. For more information about GE Healthcare, visit our website at www.gehealthcare.com. GE Healthcare 3000 North Grandview Blvd Waukesha, WI 53188 U.S.A. www.gehealthcare.com NU-0185-12.09-EN-US