A certified kit of cement-admixtures to achieve grouts for the injection of ducts in post-tensioning works.

Similar documents
MATERIAL SPECIFICATION FOR PACKAGED SILICA FUME DRY GROUT MIXTURE FOR POST TENSIONING

CVO/169897A OCTOBER 29, GROUT

State of the Art in Grout Mixes

Grouting. Recommendations for cementitious grout for NC-Bolt and Pc-Bolt. Rev. 04/18

1. Architectural precast concrete cladding units.

A. Extent of structural precast concrete work is shown on drawings and in schedules.

ADHEBIT Adhesion Promoters

3400 Tectura Designs Precast Concrete

RESILIENT INFRASTRUCTURE June 1 4, 2016

Self-compacting premix

COLOUR SHADES - OVERVIEW

thoroughly tried and tested! EWE Tapping Valves A single system for all types of pipes

HK I. Anchor size (carbon steel) HK6 HK6L HK8 Resistance F Rk [kn] 2,0 5,0 5,0

Development of grout containing classified fly ash and its application in repair and rehabilitation methods

SPECIFICATION FOR WATERBORNE TRAFFIC LINE PAINT

Construction. Sika Grouting Systems. Properties of Grout. Grouting Considerations


C. For cold-applied tape, the pavement temperature shall be at least 70 F.

FX-70. Epoxy Method Installation Guide Timber Pile Steel Pile Concrete Pile STRONGTIE

European Technical Assessment. ETA-14/0426 of 15 December English translation prepared by DIBt - Original version in German language

GabionSupply.com a division of BlueStone Supply LLC

Section 914. JOINT AND WATERPROOFING MATERIALS

Automotive Electrical & Injection Moulding Specialists. Listen Research Innovate Design. striptinning.com

CUPRON NEXT TECHNICAL DATA SHEET

APPLICATION Pad printing inks for printing of non-treated polypropylene (PP) for applications not requiring high resistances.

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

Customizable technologies adapted to each industry

European Technical Assessment. ETA-12/0056 of General Part. Technical Assessment Body issuing the ETA:

Our specials. 1st edition MAGIC PLANT.

Distribution Solutions WireSolutions. Product catalogue. Fencing

Sauna Barrel 2.5 M. health, beauty, peace of mind

HAVER & BOECKER. Information. Woven Wire Cloth Terminology, Types of Weave and Apertures

European Technical Assessment. ETA-14/0426 of 21 December English translation prepared by DIBt - Original version in German language

Laying and maintenance of cement tiles

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

Instruction manual. ZCO 2410 Conical mandrel tester

Securifor Polyester Coated Welded Mesh Panels

TOILET SOAP STARTER KIT PRODUCTION MANUAL SINGLE SPARK. Your business-in-a-box!

Epoxy Coal Tar. Protects Steel and Concrete in Marine and Industrial Environments.

Activating Your Ideas. In Stainless Steel Pipe

UPHO. ULTIMATE SAMPLE HOMOGENIZER cell disruption - user guide

RONDAL. The use of slugs is extremely widespread and diverse, because they are processed in various industries, such as:

STABILITY. SECURITY. INTEGRITY.

Reflective Solutions Engineered to Save Lives

Elcometer Pfund Thickness Gauge. Operating Instructions

ANCHORING TECHNOLOGY - GROUT VS INJECTION

SEA SELF DRILLING, THREADED, HOLLOW BAR / GROUT-ABLE SOIL NAILS / ANCHORS

Cooke Precast Concrete

Cooke Precast Concrete

FUJIFILM Europe DIS (Direct Injection System)

STUDENT LABORATORY WORKSHEET EXPERIMENT A: DRUG DELIVERY

HVU2 adhesive capsule Anchor design (ETAG 001) / Rods&Sleeves / Concrete

BUREAU OF INDIAN STANDARDS. Draft Indian Standard HOT APPLIED THERMOPLASTIC ROAD MARKING MATERIAL

European Technical Assessment ETA-04/0038 English translation prepared by DIBt. Page 2 of July 2016

Technical documentation. Sealoflex Color asphalt and Colorfalt V pigments

PURE. PRECISE. PERFECT

TIMBERMATE. Non-acrylic Water-based Woodfiller NON CRACKING NON SHRINKING UNLIMITED SHELF LIFE. Wood Putty. EdgeFiller.

The explosion-free demolition agent

TIMBERMATE. Non-acrylic Water-based Woodfiller NON CRACKING NON SHRINKING UNLIMITED SHELF LIFE. Wood Putty. GrainFiller. EdgeFiller.

Automotive Moisture-Resistant Nonwovens

MANUAL BEVELLING AND DEBURRING SYSTEM B15 AIR

WEGTHANE HPA 501 (HPA 501/ HPA 502/ HPA 503/ HPA 504)

Ferrocement water storage tanks

Lead free for our Environment. MONOLITE & HEUCODUR / VANADUR & Heuco FIT LR & TICO

Laboratory foamed bitumen plant WLB 10 S and twin-shaft compulsory mixer WLM 30. Preliminary testing to determine the mix quality.

SAFETY DATA SHEET VILLAS BITUMEN

Cembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent

PURE GP. Adhesives GENERAL INFORMATION SECTION CONTENTS. Epoxy Injection Adhesive Anchoring System

DICTATOR RTS Tube Door Closer

paint for coil coating

Cooke Precast Concrete

Glatt Technology Center

designed to help you Use the buttons, links and Forward/Back arrows at the top or bottom of your screen to get around your product guide.

Tube Wall Light 1m, 2006

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

Gloss Volume Solids 88 ± 2% (ISO ) VOC. Overcoating Data 10ºC 25ºC 35ºC Min. 24 hours 12 hours 8 hours Max. 72 hours 24 hours 24 hours

HSAF Era Stepped Aluminum Fluted Pole revision 10/6/15 kl_hasf_spec.pdf

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

Cooke Precast Concrete

Wind Transmitter First Class

PROJECT rigid foam & DIP PRINT decoration

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

World Wide Project minerv SUPERTOYS. 14 December 2015 Technical focus document in support of press release of 16 December 2015.

DINA GRAB BARS AND ACCESSORIES

NOTE: This product can be used externally if UV Guard is added (BY REQUEST ONLY).

INSTALLATION MANUAL GIOTTO SCREEN

State-of-the-art Report On FULL-DEPTH PRECAST CONCRETE BRIDGE DECK PANELS (SOA )

Eaves Lining Installation Guide

HUS 6 Screw anchor, Redundant fastening

Appearance grading of. chestnut. sawn timber. NF B Standard (2013) chestnut. Généreux par essence

Effect of admixtures on fresh grout and two-stage (pre-placed aggregate) concrete A. Nowek, P. Kaszubski, H. S. Abdelgader and J.

Tested and ready to use Quality from a single-source

Installation Instructions

Flash chromatography. MN Flash adsorbents a unique variety of phases. Separation efficiency and reproducibility

Excellence in Minimum Quantity Lubrication.

APS One. The only one all in one. Automated Pourer Stacker

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA

Instruction manual. ZCY 2400 Zehntner-Cylindrical mandrel tester

Section Meetings Section Material and Equipment. None Required

Transcription:

Superstresscem A certified kit of cement-admixtures to achieve grouts for the injection of ducts in post-tensioning works. European Technical Approval n ETA-07/0269.

Sommaire 3 Edito 4 What is Superstresscem? Superstresscem applications 5 What are the Superstresscem grout properties? 7 How to make the Superstresscem grout? 8 Recommendations 9 Safety instructions 10 References 2 Superstresscem EQIOM

Superstresscem EQIOM is a subsidiary of the Irish group CRH, worldwide leading supplier of construction products. The Group is present in 37 countries worldwide with more than 90 000 employees. EQIOM positions itself as a generator of innovations and solutions to meet the new challenges of sustainable development, which is at the heart of the strategy of EQIOM. This dynamic brings the innovation in our technics, our process and our solutions that meet the requirements of the sustainable construction. It is a matter of controlling a balance within the three poles, i.e. economic, social and environmental. EQIOM. Committed, together, to success. 3 Superstresscem EQIOM

Superstresscem What is Superstresscem? It is the offer of an optimized couple of cement and specific admixtures in order to guarantee an efficient grout. The ETA Superstresscem grout matches the most severe European regulations. Superstresscem applications During the construction of pre-stressed concrete engineering structures, the grouting of ducts with a cement grout ensures several functions: The coating of the pre-stressed steel bars - in order to protect corrosion effects under a high ph between steel and hydrated cement, i.e. steel passivation - ensures the highest protection The filling of empty spaces along the length of the tube allows to create a shield against corrosive agents In a long term, an uncomplete coating could involve corrosion and break off steel bars. The tubes grouting is an operation of primary importance, in terms of implementation quality and in terms of choosing the product; the engineering structure s life depends on this operation. Through this ETA, Holcim commits itself to control the quality and the consistency of the cement, the admixtures and the grout in its laboratories. Water + Superstresscem Admixtures + Superstresscem Cement = Superstresscem Grout The Superstresscem grout has been developed especially to meet these requirements. Superstresscem grout: First EN 447 special grout under European Technical Approval n ETA-07/0269 4 Superstresscem EQIOM

What are the Superstresscem grout properties? Superstresscem grout characteristics Characteristics Superstresscem results ETAG 013 criteria Cone fluidity, 5 C t 35 C (EN 445) 25 sec. at t 0 + 2 h. 25 sec. à t 0 + 30 min. Wick induced bleed test (ETAG 013 C.4.3.3.2.3) None at 3 hours None at 24 hours 0,3 % Sedimentation test (ETAG 013 C.4.3.3.2.2) 1 % 10 % Inclined tube test (ETAG 013 C.4.3.3.2.1) Grouting time Bleeding = 0 % Air void 0,01 % No crack 3 hours (temperature > 5 C) Bleeding 0,3 % Air void 0,3 % No crack - Nota: The grout is gently shaked in the low agitation vat as long as the Marsh fluidity test is performed. Its formula, wich is exempt from corrosive agents (S2-, chloride ), is controlled on a rheological scale by using a high performing admixture. The properties of formulation guarantee : A Marsh fluidity maintained during 2 hours A grout stability, ensuring absence of bleeding and white mixture Wick induced bleeding: none at 3 hours and 24 hours Marsh Cone Fluidity (EN445) Lab Test Results Temperature W/C Fluidity t 0 Fluidity t 2 hours 5 C 0,38 20 s 21 s 20 C 0,38 14 s 16,5 s 35 C 0,37 14 s 16,5 s 5 Superstresscem EQIOM

Injectability, sedimentation, bleeding water and stability of the grout are measured on-site with inclined tube tests: (diameter Ø 81 mm, length 5 m). This test reproduces the grout behaviour after injection or re-injection in a 2,50 m inclined tube and takes into account filter effects due to steel bars. Miscellaneous: Initial setting time > 3 hours Final setting time < 24 hours The Superstresscem grout stays homogeneous with no bleeding during injections performed under extreme temperatures (i.e. 5 C or 35 C). According to the best practice, no grout shall be placed if the temperature of the structure adjacent to the tendon is below 5 C, unless it is heated so as to maintain the temperature of the placed grout above 5 C for at least 48 h after the injection. No grout shall be placed in case its own temperature or the temperature of the tendon adjacent structure is exceeding 35 C. 6 Superstresscem EQIOM

How to make the Superstresscem grout? A high turbulent mixer (1500 rounds/min, 3000 rounds/ min) or a turbo-mixer is required to prepare the grout according to EN 446 standard 6.1. The Marsh cone fluidity (Ø 10 mm aperture) must be controlled in compliance with the EN 445 standard. Grout mixing proceeding: Poor in the mixer the exact quantity of water required (W/C between 0,35 and 0,39), Put (without opening them) the right number of water-soluble pre-dosed pockets of Adjuvant Superstresscem, Example 1 Example 2 Water 17,5 to 19,5 litres 35 to 39 litres Superstresscem Admixture Superstresscem Cement 2 pockets (put into mixing water) 4 pockets (put into mixing water) 2 sacks of 25 kg 4 sacks of 25 kg Nota : The quantities of water are only indicative and depend upon the mix-unit used on site and/or temperature. Switch on the mixer (at a normal speed) during 1 minute in order to allow the complete dissolution of pockets, Mix the right number of Cement Superstresscem sacks and keep on mixing during 4 minutes at least, then transfer the grout into the low agitation vat (60 rounds/min), Proceed to the Marsh fluidity test (EN 445). Adjust the water dosage to obtain the targeted t0 Marsh cone fluidity while keeping the bracket of W/C ratio from 0,35 to 0,39. The t0 Marsh fluidity should never be inferior to 12 sec. In the case of a Marsh fluidity inferior to 12 sec. the W/C must be reduced and a new batch must be mixed, Inject the Superstresscem grout. During grout time, keep the grout by low agitation. 7 Superstresscem EQIOM

Important instructions for use of Superstresscem : Specific and general recommendations In order to obtain optimal grout properties and to carry out properly the injection steps, it is important to follow the instructions here below : Use water according to the EN 1008 standard, Do not inject grouts on site with temperature lower than 5 C or higher than 35 C, Preserve the mixer vat from any risks of pollution, water evaporation during hot weather, Packing and logistics: The components are delivered from our warehouse in Homblières (02) in France as follows, on each pallet: Superstresscem Ciment 25 kg sacks on wrapped pallets of 1,40 MT Quantity per pallet: 56 sacks Dosage: 1 pocket + 1 sack Superstresscem Adjuvant Water-soluble pockets wrapped in a plastic bag and placed in a box Quantity per pallet: 56 pockets If the weather is hot, avoid to expose cement, admixture pockets and water at a temperature exceeding 30 C, Superstresscem cement must be stored in a dry area, on unopened covered pallets and used in a six months period from the packaging date indicated on each sack, The Superstresscem admixture must be used before use-by date printed on the box, Keep the Superstresscem admixture boxes in a dry and heated place. (T > 0 C). Furthermore, the grout mixing proceeding is printed on each Superstresscem Cement sack. For each project (quantity, delivery time, destination) EQIOM studies the most appropriate solution (truck, container) in order to ensure a complete customer satisfaction. 8 Superstresscem EQIOM

Safety instructions In case of grout projection in the eyes or on the skin, wash with drinking water. Glasses and gloves are advised. The Safety Data Sheet is available on our website www.eqiom.com Our specialists are at your disposal to answer any technical question. Launched on the market in 1998, this formulation has allowed all types of weather implementations with all site-equipments. It has been updated in 2007 with the aim of ever meeting your expectations. Up to now, Superstresscem grout has been protecting more than 40 000 Mtons of steel bars for pre-stressed concrete without any default to be reported. 9 Superstresscem EQIOM

Superstresscem references LNG tanks of Zeebrugge (B), Fos sur Mer (F) and isle of Grain (UK) Airplane bridge in Charles de Gaulle Airport (F) Viaduc de Millau (F) Viaduc de Verrières (F) Viaduc des Barrails (F) Viaduc de Digoin (F) Viaduc de Dordogne (F) Medway Viaduct (UK) Viaduc de la Rauze (F) Viaduc de Saint André (F) Viaduc TGV ligne Liège Köln (Herve, Batisse) (B) Viaduc of Rion Antirion (GR) Pont sur le Rhin (F) Pont-Canal de Houdeng (B) Viaduc de la Goulette in Tunis (TN) Viaduc de Meaux (F) in cover page Wind mill from in Ostende (B) 10 Superstresscem EQIOM

The information data described in this documentation are purely the expression of our knowledge and laboratory test results, carried out in a constant care of objectivity. They cannot be considered as a guarantee or a commitment in case of faulty use or a different application from those described in this document. Prior to any use, the Marsh fluidity test will help to check the direction for use and the grout making conditions. 11 Superstresscem EQIOM

EQIOM 49, avenue Georges Pompidou 92593 Levallois Perret Cedex T + 33 1 41 06 11 00 F + 33 1 41 06 11 01 www.eqiom.com Our entire product range is available on sheets and on our website www.eqiom.com 2016 - EQIOM January 2016