Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

Similar documents
IDM 98-III & IDM 99-III Digital Multimeters

IDM 503 & 505 Digital Multimeters

Instruction Manual IDM 66RT Digital Multimeter

Safety Information. WARNING Identifies hazardous conditions and actions that could cause BODILY HARM or DEATH

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

Instruction Manual IDM 503 & IDM 505 Digital Multimeters IDM 505

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

Data sheet IDM 98III Digital Multimeter

Data sheet IDM 99III Digital Multimeter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

ENGLISH. Datasheet Stock No RS PRO IDM 98III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

ENGLISH. Datasheet Stock No RS PRO IDM 99III Digital Multimeter. Feature: 6000 count digital display with 62 segment bar graph

IDM 61/62T Instruction Digital Multimeter Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

# Digital Multimeter

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

KMD-S04 Multímetro de bolsillo

Electrical Multimeter

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

Electrical Multimeter

Instruction Manual IPM φ/1φ Power Clampmeter EN FR IT DE ES

ICM 136R Operating Instruction Electrical Clamp-Multimeter

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

Digital Clamp Meter Model: &

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

UT207A/208A/209A Operating Manual. Table of Contents

400Amp True RMS AC/DC Clamp Meter Model EX613

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

AMM-1022 Digital Multimeter USER`S MANUAL

True RMS Digital Multimeter Model:

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

BENNING. CM7 Electrical Tester. Service Information

CONTENTS MS2033A. 1.Introduction Safety Information...01

DM-45 Digital Multimeter

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Model : OPERATING MANUAL Table of Contents (1)

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

79/26 Series III Multimeter

Model UT10A: OPERATING MANUAL Table of Contents (1)

Pen-type DIGITAL MULTITESTER

312, 316, 318. Clamp Meter. Users Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

OPERATOR S INSTRUCTION MANUAL

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Instruction Manual IDM 103N/105N/106N Digital Multimeter EN FR IT

Analog Technologies. Multimeter 115C and 117C

AC/DC CLAMP METER USER S MANUAL

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

User Manual Digital Clamp Multimeter. model no.: MSR-C600

DMM8900 SERIES USERS MANUAL

1507/1503. Insulation Testers. Users Manual

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

1.General instructions Specifications Description...7

USER'S MANUAL DMR-6700

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User Manual Digital Multimeter

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

Mini Clamp Meter Model:

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Table of Contents Title Page

AM-520 AM-530. Users Manual. HVAC Multimeter. True-rms Electrical Contractor Multimeter

Digital Multimeter, Pen Type

DVM1190 DIGITAL MULTIMETER

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

MS2030 CAT III 600 V A V AUTO RS232

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MODEL: D03128 CLAMP METER

Model 77 Series IV. Digital Multimeter. Users Manual

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

114, 115, and 117. True-rms Multimeters. Users Manual

Accuracy 1.2 PERCENT AC VOLTAGE, 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT DC CURRENT, 1 PERCENT RESISTANCE, 2.5 PERCENT TEMPERATURE Battery Type

APPA 300 Series. The Most User-Friendly High Performance Multimeter

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Sales: Technical: Fax:

DIGIT & POINTER MULTIMETER

Model UT201/202: OPERATING MANUAL. Table of Contents

Dawson DDM190. Digital Multimeter User s Manual

DIGITAL MULTIMETER AUTORANGING

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

User Manual Digital Multimeter. model no.: MSR-U1000

Autoranging Multimeter Extech EX503

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Transcription:

Africa 1 & 2 Indianapolis Street Kyalami Business Park Kyalami, Midrand, South Africa Asia 460 Alexandra Road, #15-01A PSA Building Singapore 119963 Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters Europe PO Box 99 Corby Northamptonshire NN17 9RS United Kingdom Japan West Tower (12th Floor) Yokohama Business Park 134 Godocho, Hodogaya Yokohama, Kanagawa 240-0005 Japan USA 7410 Pebble Drive Fort Worth Texas 76118-6961 Canada 1701 Woodward Drive Ste 108 Ottawa Ontario K2C 0R4, Canada South America Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile IDM 99-III

SECTION 1 SAFETY INFORMATION Safety Information Understand and follow operating instructions carefully. Use the instrument only as specified in this manual; otherwise, the protection provided by the instrument may be impaired. WARNING Identifies hazardous conditions and actions that could cause BODILY HARM or DEATH CAUTION Identifies conditions and actions that could DAMAGE the instrument or equipment under test CAUTION Disconnect the test leads from the test points before changing the position of the function rotary switch. Never connect a source of voltage with the function rotary switch in the Ω,, C, ma, or A position. Do not expose the instrument to extremes in temperature or high humidity. Never set the instrument in the Ω,, C, ma, or A position to measure the voltage of a circuit, this could result in damage the instrument and the equipment under test. If possible, do not work alone, so assistance can be given if required WARNING The following symbols may appear on the instrument and this instruction manual: Examine the instrument and probes before use. Do not use the instrument if it is wet or damaged When using test leads or probes, keep your fingers behind the finger guards. Risk of electric shock Remove the test lead from the instrument before opening the battery cover or instrument case. See instruction manual Always use the correct terminals, switch position and range for measurements. DC measurement Never attempt a voltage measurement with the test leads inserted into the A input terminals. Equipment protected by double or reinforced Insulation Verify the instrument is operating correctly by measuring a known voltage before use. If in doubt, have the instrument serviced. Battery Do not apply more than the rated voltage, as marked on the instrument, between terminals or between any terminal and earth Fuse ground. Do not attempt a current measurement when the open-circuit voltage Earth is above the fuse protection rating. Only replace a fuse with the correct type and rating as specified in this AC measurement instruction manual. Use caution when measuring voltages above 30 Vac rms, 42 Vac Conforms to EU directives peak or 60 Vdc. These voltages pose a shock hazard. Dispose of in accordance with local regulations. To avoid false readings that can lead to electric shock, replace the battery as soon as the low battery indicator appears in the display. Disconnect the circuit power and discharge all high-voltage capacitors Unsafe Voltage before making resistance, current, continuity, diode or capacitance To alert you to the presence of a potentially hazardous voltage, when the measurements. instrument detects a voltage 30 V or a voltage overload (OL) in V, mv. Do not use the instrument in a hazardous area or around explosive The symbol is displayed. gasses or vapours. Wear suitable personal protective equipment when working around or Maintenance near hazardous live conductors which could be accessible. Do not attempt to repair this instrument. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. This instrument should be calibrated yearly, or more frequently if used in harsh conditions or if it is suspected of being inaccurate. 2 3

Cleaning Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents. SECTION 2 - METER DESCRIPTION Instrument Description Front Panel Illustration 1. LCD display : 6000 counts 2. Push-buttons. 3. Rotary switch for turn the Power On / Off and select the function. 4. Input terminal for A (current measurement) 5. Input terminal for V, Ω,, Hz, and C functions. 6. Common (ground reference) input terminal. 7. Input terminal for ma current measurement. Features 6000 count digital display. 62 segment bar graph. Extra large scale white backlit display True RMS 0.08% basic DCV accuracy Automatic AC/DC Voltage detect with low impedance (Auto-V LoZ) VoltSense (Non-contact voltage detection) Smart Data Hold Peak Hold (1ms) (IDM99-III only) Min/ Max function AC+DC function Frequency counter on AC mode Capacitance measurement Temperature measurement (IDM99-III only) Low battery indicator with segments Auto Power Off (20 minutes) Shock proof from 4 feet drop CAT IV 600V/CAT III 1000V Safety standard Unpacking and Inspection Upon removing the instrument from its packaging you should have the following items. 1. IDM98-III or IDM99-III digital multimeter. 2. Test leads set (one black, one red) 3. Temperature probe (IDM99-III only) 4. User manual 5. Protective holster 6. Battery (installed) SECTION 3 MEASUREMENTS Preparation and caution before measurement Observe all warnings and cautions When connecting the test leads to the device under test connect the common test lead before connecting the live test lead ; when removing the test leads remove the test live lead before removing the common test lead. The figures on the following pages show how to make basic measurements. 4 5

Measuring AC / DC Voltage Measuring Frequency Rotate the switch and press the Function button to select the measuring function. See Using the Function Buttons Rotate the switch and press the Function button to select the measuring function. See Using the Function Buttons Measuring Resistance/Capacitance Measuring AC/DC Current Rotate the switch and press the Function button to select the measuring function. See Using the Function Buttons Rotate the switch and press the Function button to select the measuring function. See Using the Function Buttons 6 7

Measuring Continuity / Diode Measuring Temperature C / F (for IDM99-III only) Rotate the switch and press the Function button to select the measuring function. See Using the Function Buttons ( C / F) Rotate the switch and press the Function button to select the measuring function. See Using the Function Buttons 8 9

Using The Function Buttons MIN/MAX Button Function Button The MAX/MIN mode records the min. and max. input values. When the input goes below the recorded min. value or above the recorded max. value, the meter records the new value. Press HOLD button to pause the recording. Peak HOLD (for IDM99-III only) Press the Function button to change the function on the same switch position. RANGE Button Auto Range Mode Manual Range Mode In the Peak HOLD function, the meter records the peak min. value and the peak max. value; when the inputs goes below the recorded peak min. value or above the recorded peak max. value,the meter records the new value. Press HOLD button to pause the recording. 10 11

Smart HOLD Backlight The meter will beep continuously and the display will flash if the measured signal is larger than the display reading by 50 counts. Smart Hold will not be activated if the hold value is not scrolled over 50 counts when measuring AC or DC Voltage /Current with Auto-V(LoZ) Range. VoltSense Press the Backlight button to turn the backlight on/off. Disable Auto Power Off Reactivate the instrument by rotating the switch or by pressing any button. Press and hold down the VoltSense button down to activate the VoltSense function. CAUTION The number of dashes displayed indicates the electric field strength. Be aware, if no indication, voltage could still be present 12 13

Auto Power Off Disable SECTION 4 BATTERY AND FUSE REPLACEMENT CAUTION The following safety information must be observed to ensure maximum personal safety during the operation of this instrument. 1. To avoid electric shock, disconnect the test leads before replacing the instrument fuses or batteries. 2. When replacing the instrument batteries, do not mix batteries of different types or old and new batteries. 3. Check the battery polarity carefully when inserting the batteries. 4. Do not short-circuit used batteries, disassemble them, or throw them in a fire. Doing so may cause the batteries to explode. 5. Dispose of the used batteries in accordance with local regulations. Fuse Replacement Rotate the switch to the OFF position, Press and hold down the Function button and turn the instrument on. Testing the LCD Display Caution Use only fuses with the following fuse rating: Rotate the switch to the OFF position, Press and hold down the Smart- HOLD button and turn the instrument on. 440mA,1000V IR 10KA Fast acting fuse (size 35 x 10mm) DMM-B-44/100 10,000A, 1000 VAC, unity power factor and 10,000A, 1000 VDC with time constant of 2.2ms 11A, 1000V IR 20KA Fast acting fuse (size 38 x 10mm) DMM-B-11A 20,000A, 1000 VAC, power factor 0.2; 20,000A, 1000 VDC, time constant 10ms. (size 38 x 10mm) 14 15

Low battery and Battery Replacement Replace the battery as soon as the low battery indicator appears to avoid false reading. Refer to the following figure to replace the batteries Measurement Category I II III IV Application Measurements on circuits not directly connected to mains. Examples include: Measurements on battery powered equipment and specially protected (internal) mains-derived circuits. Measurements on circuits directly connected to the low voltage installation. Examples include: Household appliances, portable tools and similar equipment. Measurements performed in the building installation. Examples include measurements on distribution boards, junction boxes, socket-outlets and wiring and cables in the fixed installation. Measurements performed at the source of the lowvoltage installation. Examples include measurements on primary overcurrent protection devices and electricity Instruments SECTION 5 - SPECIFICATIONS General Specifications Maximum voltage applied to any terminal : 1000 Vac rms or 1000 Vdc. rms Display : 6000 counts. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : OL Batteries Life : 150hours alkaline battery (No backlight) Low Batteries Indication : Voltage drops below operating voltage, will flash. Power Requirement : PP3 9V battery Auto Power Off : 20 minutes. Operating Temperature : -10 ~10 C 10 C ~ 30 C ( 80% RH), 30 C ~ 40 C ( 75% RH), 40 C ~ 50 C ( 45%RH) Storage Temperature : -20 C to 60 C, 0 to 80% R.H. (batteries not fitted) Temperature Coefficient : 0.15 x (Spec.Accy) / C, < 18 C or > 28 C. Measure : Samples 3 times per second. Altitude : 6561.7 ft (2000m) Safety : Complies with EN61010-1, UL61010-1,IEC 61010-1, CAT IV 600V, CAT III 1000V Weight : 460g (including battery) Dimensions (W x H x D) : 94mm x190mm x 48mm with holster. Pollution degree : 2 EMC : EN 61326-1 Shock vibration : Sinusoidal vibration per MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.) Drop Protection : 4 feet drop to hardwood on concrete floor. Indoor use only. 16 17

Electrical Specifications (2) Auto-V Accuracy is ±(% reading + number of digits) at 23 C ± 5 C < 80%RH. (1) Voltage 60.00mV DC 0.01mV ± (0.08% + 10d) 600.0mV DC 0.1mV ± (0.1% + 2d) ± (0.08% + 2d) 6.000V DC 0.001V ± (0.09% + 2d) ± (0.08% + 2d) 60.00V DC 0.01V ± (0.09% + 2d) ± (0.08% + 2d) 600.0V DC 0.1V ± (0.09% + 2d) ± (0.08% + 2d) 1000V DC 1V ± (0.09% + 2d) ± (0.08% + 2d) 60.00mV AC 0.01mV ± (1.20% + 5d) 600.0mV AC 0.1mV ± (1.5% + 5d) ± (1.20% + 5d) 6.000V AC 0.001V ± (1.0% + 3d) ± (0.80% + 5d) 60.00V AC 0.01V ± (1.0% + 3d) ± (0.80% + 5d) 600.0V AC 0.1V ± (1.0% + 3d) ± (0.80% + 5d) 1000V AC 1V ± (1.0% + 3d) ± (0.80% + 5d) Input Protection : 1000V DC or 1000V AC rms AC Frequency Response : 50Hz ~ 1KHz Input Impedance : Approx. 3kΩ. AC Conversion Type : Conversion type and additional specification are same as voltage function. (3) Current 600.0V DC 0.1V 1000V DC 1V 600.0V AC 0.1V 1000V AC 1V ± (1.0% + 3d) ± (0.80% + 3d) 60.00mA DC 0.01mA ± (1.0% + 3d) ± (0.8% + 3d) 600.0mA DC 0.1mA ± (1.0% + 3d) ± (0.8% + 3d) 6.000A DC 0.001A ± (1.0% + 3d) ± (0.8% + 3d) Input Protection : 1000VDC or 1000VAC rms AC Frequency Response : 50Hz ~ 1KHz Input Impedance : 10MΩ, <100pF AC Conversion Type : AC conversions are ac-coupled, true rms responding, calibrated to the sine wave input. For non-sine wave add the following Crest Factor corrections: For Crest Factor of 1.4 to 2.0, add 1.0% to accuracy. For Crest Factor of 2.0 to 2.5, add 2.5% to accuracy. For Crest Factor of 2.5 to 3.0, add 4.0% to accuracy. 10.00A DC 0.01A ± (1.0% + 3d) ± (0.8% + 3d) 60.00mA AC 0.01mA ± (1.5% + 3d) ± (1.2% + 3d) 600.0mA AC 0.1mA ± (1.5% + 3d) ± (1.2% + 3d) 6.000A AC 0.001A ± (1.5% + 3d) ± (1.2% + 3d) 10.00A AC 0.01A ± (1.5% + 3d) ± (1.2% + 3d) Input Protection : Protected by high energy fuses. 440mA, 1000V AC/DC 10KA Fast acting fuse for ma input. 11A, 1000V AC/DC 20KA Fast acting fuse for A input Max. Measuring Time : 3 minutes for A input, 10 minutes for ma input. Rest time 20 minutes min. AC Conversion Type : Conversion type and additional specification are same as voltage function. AC Frequency Response : 50Hz ~ 1KHz 18 19

(4) Peak HOLD (For IDM99-III only) Specified accuracy ±150d. (5) Resistance Range Resolution Accuracy 600.0Ω 0.1Ω ± (0.8% + 5d) 6.000KΩ 60.00KΩ 600.0KΩ 6.000MΩ 0.001KΩ 0.01KΩ 0.1KΩ 0.001MΩ ± (0.8% + 2d) 40.00MΩ* 0.01MΩ ± (1.0% + 5d) (7) Diode Test Input Protection : 1000V DC or 1000V AC rms Max. Open Circuit Voltage : Approximately. 2.5V Max.Test Current : Approximately 0.4mA (8) Capacitance Range Resolution Accuracy 2.000V 1mV ± (1.5% + 2d) Range Resolution Accuracy Input Protection : 1000VDC or 1000VAC rms Max. Open Circuit Voltage : Approx. 2.5V for 600Ω & 6kΩ Range. Approx. 0.6V for others. Max. Test Current : Approximately 0.1mA. * There is a little rolling less than ±50 digits when measuring > 10.00MΩ. 1.000µF 10.00µF 100.0µF 1.000mF 0.001µF 0.01µF 0.1µF 0.001mF ± (1.2% + 2d) (6) Continuity Check 10.00mF 0.01mF Range Resolution Accuracy 600.0Ω 0.1Ω ± (0.8% + 5d) Input Protection : 1000VDC or 1000VAC rms Max. Open Circuit Voltage : Approx. 2.5V Max. Test Current : Approx. 0.1mA Continuity Threshold : <30Ω Beep On. >100Ω Beep OFF. Continuity Indicator : 2.7kHz Tone Buzzer Input Protection : 1000V DC or 1000V AC rms Max. Measuring Time : 0.7 sec for 1nF~1mF 3 sec for 1mF~10mF (9) Frequency Counter Range Resolution Accuracy 100.00Hz 1000.0Hz 10.000KHz 0.01Hz 0.1Hz 0.001KHz ± (0.1% + 2d) 100.00KHz 0.01KHz Input Protection : 1000V DC or 1000V AC rms Min. Frequency : 1Hz Sensitivity : > 5.0Vp-p (for ACV 1Hz ~ 10kHz). > 10Vp-p (for ACV 10kHz ~ 100kHz). >2mAp-p (for AC ma). 20 >0.2Ap-p (for ACA). 21

(10) Temperature (For IDM99-III only) (13) AC+DC ma IDM99-III Range Resolution Accuracy -40.0 C ~ 400 C 0.1 C ± (1.0% + 10d) -40.0 F ~ 752 F 0.1 F ± (1.0% + 18d) 60.00mA 0.01mA ± (2.5% + 5d) ± (2% + 10d) 600.0mA 0.1mA Input Protection : 1000V DC or 1000V AC rms * Does not include accuracy of the thermocouple probe. * Accuracy specification assumes surrounding temperature stable to ± 1 C. For surrounding temperature changes of ± 5 C, rated accuracy applies after 2 hours. (11) AC+DC Voltage Additional specification are same as voltage function. (14) AC+DC A Note: When measuring AC+DC, the AC signal may contain a DC level, the AC+DC True RMS value might not be accurate if the peak voltage of AC+DC value is over full scale. 6.000A 0.001A 10.00A 0.01A ± (2.5% + 5d) ± (2% + 5d) Additional specification are same as voltage function. 6.000V 0.001V 60.00V 0.01V 600.0V 0.1V ± (2.5% + 5d) ± (2% + 5d) 1000V 1V Additional specification are same as voltage function. (12) AC+DC mv 60.00mV 0.01mV 600.0mV 0.1mV ± (2.5% + 5d) ± (2% + 10d) Additional specification are same as voltage function. 22 23