Protection and safety SQZ3 phase and sequence relay

Similar documents
EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic relays. Monitoring. Monitoring

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Control module CP-A CM

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Technical features table for miniature circuit-breakers SH 200 Series

Three-phase monitoring relay CM-PVE

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Control module CP-A CM

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Moeller Electric Corporation

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Transformers, Power Supply Units and Socket Outlets

Three-phase monitoring relays

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents


Contactors and Contactor Assemblies

IMPULSE SWITCH, REMOTE SWITCH

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Current monitor Type C 551

Type CP-S, CP-C & CP-A Switch mode

Three-phase monitoring relay

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Zelio Control Measurement Relays

Electronic timer CT-SDD.22

Electronic timer CT-SDS.22

Installation / Monitoring Technique

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Three-phase monitoring relays Product group picture

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

XUA1 - AC Voltage and phase balance relay

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

27/04/2015

Three-phase monitoring relays CM-PFE and CM-PFE.2

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

For non-electrical quantities

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Thermistor motor protection relays

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-TGD.22

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Frequency- and voltage monitoring. Technical data G4PF21-1

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

XN2 - Mains decoupling relay. Manual XN2 (Revision C)

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Three-phase monitoring relay CM-PFS

Output of three-phase motors at 50 Hz and 400 V

XN2 - Mains decoupling relay

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

XP2-R Power and Reverse Power Relay

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Advantages. Applications

Switching power supplies CP range, Linear power supplies CP-L range. Content

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Power Supplies 3. SDN-C Compact DIN Rail Series

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Protection components

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Liquid level monitors and controls

Installation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Data sheet Functional Electronics PRO-M. Power supplies for space-saving use in automation technology

Description Basic devices with positive operation contacts

QUINT-PS/ 3AC/24DC/10

Electronic measuring and monitoring relays CM-range

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relay CM-PBE

Transcription:

SQZ3 phase and sequence relay Supply voltage [Vn] 400 V a.c. Frequency [Hz] 0/60 SQZ3 2CSC4001F0201 Contact type [A] 1 CO, 20 V, 10 A (cos =1) safety switching Minimum voltage adjustment trimmer [%] 100 to 70% of Vn Intervention delay adjustment trimmer [s] 2 to 20 (only for min. voltage) Protection degree [IP] 20 Operating temperature [ C] -10 + Power consumption [W] 1. Modules [No.] 3 SQZ3 phase and sequence relay SQZ3 relay performs the following continue monitoring functions on three-phase networks at 400 V a.c.: phase sequence phase failure minimum voltage (adjustable up to 70% of Vn). If one of the three failures is detected, the output relay (safety switching contact) intervenes with a delay adjustable from 2 to 20 seconds for minimum voltage only and controls the following: acoustic alarms motor controlling contactors circuit-breakers with coils. 801242 372004 SQZ3 2CSM111310R1331 0.300 1 System pro M compact 2CSC 400 002 D0211 /73

RH/RL maximum and minimum current/voltage relays Technical characteristics Rated voltage Un [V] a.c. 230 Contact type 1 CO, 20 V, 16 A 2CSC40013F0201 Rated frequency [Hz] 0/60 Current relay alarm thresholds [A] 2,, 10 Voltage relay alarm thresholds [V] 100, 300, 00 Adj. calibration of In and Vn% [%] 30...100 RH/RL Adjustable hysteresis value [%] 1...4 Time delay [s] 1...30 Power consumption [W] 2 Modules [No.] 3 Control relay alarm indication Power supply lighting indication red LED on = alarm green LED on = ON Alarm indication blinking green LED = alarm Maximum and minimum current/voltage relays These relays are used for monitoring current and voltage on single-phase electrical networks, to ensure perfect protection of the devices installed on the system. The range includes: maximum current (RHI) and maximum voltage (RHV) relays. The control relay remains on as long as the measured quantity stays below the preset threshold value. minimum current (RLI) and minimum voltage (RLV) relays. The control relay remains on as long as the measured quantity stays above a preset threshold value. Both types of relays have trimmers for adjusting the switch-off delay and the hysteresis (from 1 to 4%). The 100 V and A relay inputs allow indirect connection of external CTs and VTs for monitoring voltage and current values exceeding the maximum device scale Type 801242 maximum current relay 334309 RHI 2CSM121310R1321 0.300 1 maximum voltage relay 334101 RHV 2CSM111310R1321 0.300 1 minimum current relay 334200 RLI 2CSM122310R1321 0.300 1 minimum voltage relay 334002 RLV 2CSM112310R1321 0.300 1 Technical Details for RH/RL p.10/189 Frequently asked question - FAQ: Can I use RH/RL with current/voltage transformers? Yes, A and 100V inputs are made for that. /74 System pro M compact 2CSC 400 002 D0211

US 1 US 2 Rated voltage 20 V a.c. 2CDC01087S0009 Frequency Measuring supply voltage range: overload capacity Switching capacity 48-63 Hz 3N 400/230 V a.c. (terminals N-L1-L2-L3) 3N 49/26 V a.c. device in series (distance < mm): 70 VA (3 A/20 V a.c.); E 236-US 1 device not in series (distance > mm): 120 VA ( A/20 V a.c.) Rated insulation voltage 20 V a.c. (corresponds with IEC 664-1) Rated surge voltage 4 kv Tripping delay ca. 100 ms Clearence and creepage distance Mechanical service life > 6 mm (between contact and electronics) 20 x 106 operations Electrical service life at 10000 VA 2 x 10 operations 2CDC01088S0009 Max. switching rate max. 6/min (1000 VA Ohmic load); max. 60/min (100 VA Ohmic load) Ambient temperature -2 C/-13 F to + C/131 F Overvoltage category III E 236-US 2 Accuracy in setting tolerance (US 2) % non-changing repeat accuracy ±1 % environment: temperature effect 0.1 %/ C Terminals up to 4 mm 2 Specifications VDE 0110 and VDE 043 EMC tests EM 0081-1 and EN 0082-2 Displays Power loss LED green= supply voltage applied; LED yellow= relay status 1.7 W Function The green LED is lit when the supply voltage is applied. If each phase voltage exceeds 19 V (US1) or exceeds the preset threshold value (US2) with respect to the neutral including the hysteresis when switching the device on, the relay switches immediately into the working position. The yellow LED is lit. If at least one phase voltage falls below the threshold value, the relay goes back into its normal position and the yellow LED goes out. If also phase 2 fails, the green LED goes out, too. It is indispensable to connect the neutral conductor! Application - devices with 2CO contacts For the control of three-phase undervoltage (each phase to neutral) of switchgear, also for installations according to DIN VDE 0100-718 (power installations in hospitals and rooms used for medical purposes outside of hospitals) and DIN VDE 0108-100 (power installations and safety supply in buildings where many people gather). US 1: 3 phases to neutral with fixed threshold at 19 V; hysteresis fixed % US 2: 3 phases to neutral with fixed threshold at 160 240 V; hysteresis fixed % Contact 4016779 Technical Details for E236 p.10/190 2CO 11087 E 236-US 1 2CDE16000R2001 0.09 2CO 11094 E 236-US 2 2CDE16010R2001 0.09 System pro M compact 2CSC 400 002 D0211 /7

E 236 2CDC 01 234 F000 US 1.1 US 2.1 US 1.1D Supply circuit Supply voltage (= measured voltage): 3N~ 400/230 V AC (terminals N-C1-C2-C3) Overvoltage permanent: 3N~ 49/26 V AC Frequency: 48 63 Hz (AC sinus) Rated surge voltage: 4 kv Overvoltage category: III Output circuit (isolated two-way-switch) Rated voltage: 20 V AC Switiching capacity: 120 VA ( A/20 V AC) Continuous current: 120 VA ( A/20 V AC) Fuse protection: A flink Serviceable life, mechanical: 1x106 switchover cycles Serviceable life, electric: 2x10 switchover cycles at 1,000 VA resistive load Max. switching rate: max. 6/min at 1,000 VA resistive load max. 60/min at 100 VA resistive load Trip delay: ca. 200 ms Pick-up delay (US 1.1D) 0.1 10 min Accuracy under constant conditions setting accuracy (US 2.1/1.1D): repeat accuracy: % of full scale value 2 % 1 % temperature effect: Ambient temperature: 2 to + C Terminals: 1 x 0. to 2. mm² with/without connector sleeve 1 x 4 mm² without connector sleeve 2 x 0. to 1. mm² with/without connector sleeve 2 x 2. mm² without connector sleeve Pick-up torque: max. 1 Nm Mounting position: optional Vibration resistance: 10 to Hz 0.3 mm (IEC 68-2-6) Shock resistance: 1 g 11 ms (IEC 68-2-27) Standards: VDE 0110 und VDE 043 EMC tests: EN 61000-6-2 and EN 61000-6-4 Back-up fuse 16 A Displays: green LED U/t ON all 3 voltages ok green LED U/t flashes time-out indication yellow LED ON/OFF position of output relay All measured inputs have to be connected to one phase each. If no three-phase measurement should be carried out, measured inputs have to be connected to one phase to apply the required voltage to all measured inputs. If a load causes inverse voltage exceeding the threshold value Us, phase failures cannot be identified. A neutral conductor must be connected in any case! Technical Details for E236 p.10/190 /76 System pro M compact 2CSC 400 002 D0211

Devices for panel installation onto mounting rails (3 mm) according to DIN EN 6071 mounting depth: 68 mm mounting width: 17. mm = 1 module color: gray, RAL 703 E 236-US 1.1 2CDC 01 234 F000 Application - devices with 1CO contact For three-phase undervoltage monitoring (each phase connected to a neutral conductor) of switchgear. Devices with fixed threshold value (US 1.x and US 1.1 D) also for installations according to DIN VDE 0100-718 (for medical purposes) and DIN VDE 0108-100 (power installations and safety supply in installations for gathering of people). US 1.1: 3 phases to neutral conductor with fixed threshold value at 19 V; hysteresis fixed at % US 2.1: 3 phases to neutral conductor with threshold value range of 160 240 V; hysteresis fixed at % US 1.1D: 3 phases to neutral conductor with fixed threshold value at 19 V; hysteresis fixed at %, but with switch-on delay of 0.1 (6 sec.) to 10 min E 236-US 2.1 2CDC 01 236 F000 2CDC 01 23 F000 Undervoltage monitoring device with pick-up delay E 236-US 1.1D If the measurement of the voltage of all phases connected exceeds the switching threshold U s, including the hysteresis, the time delay (t) starts to run and the (green LED U/t) flashes. Upon expiry of the time delay (t), the output relay R picks up (yellow LED on, green LED U/t flashes). If the measured voltage of one of the connected phases falls below the switching threshold U s, the output relay deenergizes (yellow LED is off, green LED U/t is off). Contact 4016779 EAN Type code 1 two-way switch 61776 E 236-US 1.1 2CDE16001R2001 0.0 10 1 two-way switch 61783 E 236-US 2.1 2CDE16011R2001 0.0 10 1 two-way switch 61790 E 236-US 1.1D 2CDE16001R2011 0.0 10 kg pc. E 236-US 1.1D System pro M compact 2CSC 400 002 D0211 /77