6125H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions comply with PI 609 & MSS-SP-6, ompletely assembled and tested, Ready for installation. pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications with 0% leakage. Typical applications include cooling tower bypass, primary flow change-over systems, and large air handler coil control. Jobsite Note Valve assembly should be stored in a weather protected area prior to installation. Reference the butterfly valve installation instruction for additional information. ate created, 09/06/2016 - Subject to change. elimo ircontrols (US), Inc. Technical ata 1894 Service chilled, hot water, up to 60% glycol low haracteristic modified equal percentage ontrollable low Range 90 rotation Size [mm] 5 [125] nd itting for use with NSI lass 125/150 flanges ody ductile iron STM 536 ody inish poxy powder coated Stem Packing PM (lubricated) Seat PM Shaft 416 stainless steel ushings RPT isc 304 stainless steel ody Pressure Rating [psi] NSI 125, standard class Number of olt Holes 8 Lug Threads 3/4-10 UN Media Temperature Range -22 to 250 [-30 to 120 ] (Water) lose-off Pressure 200 psi mbient Temperature Range -22 to 122 [-30 to 50 ] Rangeability 10:1 (for 30 to 0 range) Maximum Velocity 12 PS v 1022 Weight 16.5 lb [.5 kg] Leakage 0% Servicing maintenance free low Pattern % O MXIMUM LOW 100 90 80 0 60 50 40 30 20 low/v v 10 v 20 v 30 v 40 v 50 v 60 v 0 v 80 v 90 0.5 29 61 133 23 392 620 930 1022 6125H R Suitable ctuators Non-Spring R(X), SY2 8.5 [216] 2.21 [56.1] 18.5 14.66 4.48 [114] [46] [32.3] 10 0 20 10 30 50 40 60 80 0 90 100 % O VLV OPNING
6125H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc R..N4(H) 14.1 [358] 2.21 [56.1] 20.6 [523.2] 16.20 [411] 4.48 [114] ceiling SY J 13 [332] 2.21 [56.1] 22.44 [50] 18.00 [45] 4.48 [114] 30.2 [6] J ate created, 09/06/2016 - Subject to change. elimo ircontrols (US), Inc.
Modulating, lectronic ail-safe, 24 V, for 2 to 10 V or 4 to 20 m ontrol Signal ate created, 09/01/2016 - Subject to change. elimo ircontrols (US), Inc. Technical ata 9651 Power Supply 24 V ± 20%, 50/60 Hz, 24 V ± 10% Power onsumption Running 12 W Power onsumption Holding 3 W Transformer Sizing 21 V (class 2 power source) lectrical onnection terminal block Overload Protection electronic thoughout 0 to 90 rotation Operating Range Y 2 to 10 V, 4 to 20 m w/ ZG-R01 (500, 1/4 W resistor), variable (V, floating point, on/off) Input Impedance 100 k for 2 to 10 V (0.1 m), 500 for 4 to 20 m, 1500 for On/Off eedback Output U 2 to 10 V, 0.5 m max, V variable Torque 801 in-lbs [90 Nm] minimum Position Indication integrated into handle Manual Override external push button Running Time (Motor) 150 sec (default), variable (90 to 150 sec) Running Time (ail-safe) 35 sec Humidity 5 to 95% RH non condensing (N 6030-1) mbient Temperature Range -22 to 122 [-30 to 50] Storage Temperature Range -40 to 16 [-40 to 80] Housing NM 2, IP54, UL enclosure type 2 Housing Material polycarbonate Noise Level (Motor) <45 d () Noise Level (ail-safe) <50 d () Servicing maintenance free Quality Standard ISO 9001
Modulating, lectronic ail-safe, 24 V, for 2 to 10 V or 4 to 20 m ontrol Signal Wiring iagrams INSTLLTION NOTS ctuators with appliance cables are numbered. Provide overload protection and disconnect as required. 24 V Transformer 1 3 16 46 4 (1) ommon 16 46 4 ctuators may also be powered by 24 V. Only connect common to negative (-) leg of control circuits. 500 resistor (ZG-R01) converts the 4 to 20 m control signal to 2 to 10 V. or triac sink the ommon connection from the actuator must be connected to the Hot connection of the controller. Position feedback cannot be used with a triac sink controller; the actuator internal common reference is not compatible. IN4004 or IN400 diode. (IN400 supplied, elimo part number 40155). ctuators are provided with a numbered screw terminal strip instead of a cable. ctuators may be controlled in parallel. urrent draw and input impedance must be observed. Master-Slave wiring required for piggy-back applications. eedback from Master to conrol input(s) of Slave(s). Meets culus requirements without the need of an electrical ground connection.! WRNING! LIV LTRIL OMPONNTS! uring installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. ailure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Position ( ) eedback V (+) On/Off 24 V Transformer ( Only) Position ( ) eedback V (+) loating Point 24 V Transformer ontrol Signal ( ) V/m (+) Position eedback V V/m ontrol unctions Min 0% Mid 50% Max 100% Normal ontrol mode acc. to Y 1 24 V Transformer ( Only) ontrol Signal ( ) V / m (+) Override ontrol 12 500 1/4 watt Wht (3) 12 Pnk (4) a b c Org (5) 1 10 16 46 4 (1) ommon 1 3 5 16 46 4 (1) ommon lk (1) Red (2) 1 5 ommon + Hot Y Input 1 Y Input 2 U Output ate created, 09/01/2016 - Subject to change. elimo ircontrols (US), Inc.
Modulating, lectronic ail-safe, 24 V, for 2 to 10 V or 4 to 20 m ontrol Signal 24 V Transformer Master 1 5 46 4 ( ) ontrol Signal (+) lk (1) ommon Red (2) + Hot Wht (3) Y 1 Input Org Slave lk (1) Red (2) 1 ommon + Hot Wht (3) Org (5) Y 1 Input U Output Master - Slave ate created, 09/01/2016 - Subject to change. elimo ircontrols (US), Inc.