Zone Paging System. Model PCM2000. Features. Technical Specifications

Similar documents
Mute send & receive. 4 Priority levels Bus assignable Balanced, transformer-isolated

PCM Paging Control System

Telephone / Background Music Interface Model VA-TBM. Installation and Use Manual

INDUSTRIAL SCANNERS AND SYSTEMS

V-9963 DIGITAL FEEDBACK ELIMINATOR

Input Modules. Models BAL2S, BRG1R, MAX1R, MIC1S, MIC2S, MIC1X, MIC2X, SAX1R, TBL1S, TEL1S, TNG1S DESCRIPTION FEATURES

MULTI-TONE GENERATOR V

Mute send & receive. 4 Priority levels Bus assignable Balanced, transformer-isolated

Models M300, M450, and M600. M-Class Series Amplifiers Designed for Reliability, Flexibility, and Power!

5 yr. Station Level Paging Adapter. Model 300PBX-SC LINKS TELEPHONE TO SELECTONE OR PUBLIC ADDRESS SYSTEM. dedicated extension

Ambient Level Controller

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30

RIO1S. Relay / Input / Output Transformer-Balanced Module. Features

Paging Adapter Amplifier Integration Guide. Algo Support, v1.

TECHNICAL. Time and Temperature Announcer DVA-TNT. Time and Temp Announcer

Industrial Wireless - RFID Antenna

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

ARUBA 90 SERIES ACCESS POINTS

1825 Duet Plus Installation Guide

FreeSpace IZA 250-LZ / 190-HZ TECHNICAL DATA SHEET. integrated zone amplifier. Key Features. Product Overview. Product Information.

9000M2 Series Modular Digital Matrix Mixer and Mixer/Amplifiers

PagePac Plus AmpliCenter V /V /V

TECHNICAL. ZPI-4 Four Zone Paging Interface. Four Zone Paging Interface

PM1060 / 1120 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics.

Chapter 4. Multicom Administrative Communication System. Operating Instructions

Z4MK3/Z8MK3 : Zone Mixers

FREQUENCY RESPONSE CURVE

FreeSpace IZA 2120-LZ Integrated Zone Amplifier

OVERHEAD PAGE MANAGEMENT OPM-3SM Multiple Channel Page Stacker, Feedback Eliminator and Messaging System

ARUBA AP-124 AND AP-125 ACCESS POINTS

Classic Series Public Address Amplifiers C10 & C20 Models

SA 125 mixer amplifier. user manual

AUTOMATIC MIXER AX-1OOOA

Classic Series Public Address Amplifiers C10 & C20 Models

AMP SELECTOR Owner s Manual

OVERHEAD PAGE MANAGEMENT OPM-3SM Multiple Channel Page Stacker, Feedback Eliminator and Messaging System

Classic Series Amplifiers C35, C60, & C100 Models

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

VS-900 Security Intercom Systems. Architectural and Engineering Specification

Model CC4052. CC Series Amplifier. Installation and Use Manual

802.11n WLAN Access Point

TECHNICAL. Interface Your Voice Paging System with Virtually Any Telecom or IP Phone System. FXI-1 FXO / FXS / Telecom Smart Paging Interface

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!"

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

MODEL 45B. Z-Patch. A Remote-Programmable, Multi-User Telephone Interconnect

Model CC4041. CC Series Amplifier. Installation and Use Manual

PagePac Plus AmpliCenter V A/V A Installation and Use

Overview. Thank you for purchasing the Suhr Eclipse Dual Overdrive/Distortion Pedal.

MediaMatrix X-Frame 88

Series 3000 Model R-107A

Models M300, M450, and M600. M-Class Series Amplifiers Designed for Reliability, Flexibility, and Power!

PagePac 20. ZoneMate 39 Service Manual For. Voice Paging System IS SM Issue 4, Nov. 1987

PagePac Plus AmpliCenter V A - (D300A) V A - (D100A) V (D40) Installation and Use

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

Built. Demanding. To Meet The Most. User Requirements. SWM Series Wall Mount Amplifiers

W FXS LS/GS Channel Unit 600 Ohms

2.4GHZ WIRELESS SYSTEM FOR POLICE VIDEO RECORDING

1. INTEROPERABILITY GATEWAY DEVICES

PA-15. Add Paging, Loud Ringing and Background Music to Centrex, PABX, IP, or Key Systems. Features. Applications. Specifications

Interface Your Paging System with Virtually Any Telecom or IP Phone System

PagePac 20 Voice Paging System ZoneMate 9 Service Manual

Overview. Features. Technical Data Sheet 1 / 5. Power Amplifier XMV8140-D

igeacom User Guide V2.0

WEBS-MT/R Tower Installation Instructions

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

3.Avoid spilling liquids or allowing materials to enter the cabinet

Call Progress Tone and Ringing Signal Generation

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions

Guardian Telecom Inc Fisher Road S.E., Calgary, Alberta, Canada T2H 0W3 Voice Fax

ADDENDUM 1. Bid# , Radio Interoperability System for the Sheriff's Office

SYSTEM MANAGEMENT AMPLIFIER VM-2120 (120 W) VM-2240 (240 W) RM-200M RM-210 EV-200 SV-200M

SR3400 Base Station Module Configuration and Use Series-2 Cards Only

for Mass Notification Installations

WEBS-MT/R Tower Installation Instructions

MEGAPLEX-2100 MODULE VC-16A. 16-Channel PCM/ADPCM Voice Module Installation and Operation Manual. Notice

... yet still led out of the terminal quickly and safely in an emergency.

User Instructions DSI 2008 Digital System Interface ADAM, ADAM CS, and Zeus Intercoms

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

Figure FXS Front Panel. Figure FXS Front Panel

Instruction Manual. KP-1 Series 10M, 6M, 2M, 1-1/4M, 70 CM. IN-SHACK GaAsFET PRE-AMPLIFIER. MIRAGE KP-1 Pre-Amplifier

Bosch Communications Systems Get your message across, effectively.

Contents 1. FEATURES EQUIPMENT DESCRIPTION INSTALLATION OPERATION TROUBLESHOOTING SPECIFICATIONS...

TABLE OF CONTENTS. Keypad Programming Manual 1

PTR-1500 AUDIO TONE TELEPROTECTION TERMINAL FEATURES DESCRIPTION

INSTALLATION MANUAL VOICE EVACUATION SYSTEM FS-7000 SERIES

Installation and Operation Manual

AT&T SERVICE MANUAL. PagePac VS (AT&T VERSION) INSTALLATION

Part VI: Requirements for Integrated Services Digital Network Terminal Equipment

RADIO INTERCOM SYSTEM OPERATING INSTRUCTIONS MODEL 260

Mixing Power Amplifiers WA-MA120N WA-MA240N

TK-D740 TK-D740H TK-D740HV TK-D840 TK-D840H TK-D840HU

V-9927A DIGITAL MULTI-TONE GENERATOR

Qt 600. Sound Masking - Paging - Music Installation Guide. Purchase date: Install date: MAC Address

CAT-260 Repeater Controller Computer Automation Technology, Inc

Power Intercom Systems Models PI35A & SI35A

OPERATING INSTRUCTIONS NETWORK INTERCOM SYSTEM AN-8000 SERIES

TOA 900 SERIES POWER AMPLIFIER P-924A

TOA 500 SERIES MIXER POWER AMPLIFIER

PRELIMINARY AA35G/AA60G. 3-Input, 35-Watt Mixer Amplifier with Global Power Supply

Transcription:

Zone Paging System Model PCM2000 Features One-zone to 99-zones of simultaneous highpower and low-power paging Up to 32 paging zone groups Universal telephone interface designed for direct connection to loop start and ground start trunks, to PBX or KEY paging ports which supply DTMF capability, and to analog T/R lines Modular integration assures reconfiguring and expansion with minimum time and expense Optional talkback paging and time-triggered signaling events with PCMTBM module Field programmable using DTMF and DIP switches Signaling features include night ringer zone group, emergency/shift change zone group, code call zone group Emergency All-Facility Override Paging Background music assigned per zone; Local Background music sourcing capability Relay drivers and Aux contacts included Allows total system amplifier power of up to 250W Technical Specifications Registered under Part 68 of FCC Rules Ringer Equivalence: 1.0B Operating Voltage: 12V DC Operating Current (max.): 1.5A (9-zone system) Audio Power Capability: 250W/9-zone system Operating Temperature: 25 to 100 F Operating Humidity: 0 to 90% noncondensing Dimensions (single module): 1-1 /2" W x 7-1 /2" H x 4-1 /4" D Shipping Weight (single module): Approximately 2 lb. Specifications subject to change without notice. 1995 Bogen Communications, Inc. Part No. 54-7833-03C Printed in U.S.A. 0303

Description The Bogen PCM2000 is a modular telephone zone paging and control system. By integrating unique, multi-function modules, the PCM2000 offers both incredible flexibility and capability for future expansion. The Bogen PCM2000 Zone Paging System is designed for direct connection to loop start and ground start trunks, to PBX or KEY paging ports which supply DTMF capability, and to analog T/R lines.the unit allows total system amplifier power of up to 250W. The PCM2000 is a fully-integrated zone paging and signaling system with an extensive list of features: Simultaneous high- & low-power paging Zone and zone group paging (32 paging zone groups, each with up to 99 zones) Built-in talkback amplification (requires PCMTBM module) Background music assigned per zone Local BGM sourcing capability Night ringer zone group Emergency zone group with choice of built-in tones or outside tone source Emergency all-facility page override Eight daily time-triggered signaling events (requires PCMTBM module) Pattern & echo code calling Daily master clock synchronization Relay driver per zone Auxiliary contacts The PCM2000 allows for the design of a system that is specifically tailored to the requirements of the facility owner. The basic system supports up to three paging zones and consists of only three modules: PCMCPU Central processor PCMTIM Telephone interface PCMZPM Zone module (3 zones) The PCMCPU module includes a set of DIP switches to set the system ID, a Program/Run switch that allows system programming, a Power jack for 12V DC power, and audio connections for central amplifier, low-power BGM, high-power BGM, emergency/shift change trigger, and auxiliary trigger. The PCMTIM telephone interface module incorporates a universal interface so that connection to any telephone system is rapid and trouble-free. The module connects to the telephone system via a standard RJ11 plug and is programmed simply by using common DIP switches.all other connections are made to built-in terminal blocks using only a small screwdriver. Setup is also easy. Zone group programming, selection of all signaling functions, and all other parameters are set by simply dialing in with a touch-tone telephone. The telephone interface module is equipped with three RJ11 jacks for Night Ring, Tel Line, and Override. The NIGHT RINGER feature can be activated from 90V ring signal or contact closure.the TEL LINE jack can be used to program the system locally and provides 48V talk battery. The OVERRIDE feature permits all-zone override paging from a dedicated telephone, trunk, or microphone (with suitable pre-amp). The PCMZPM zone paging module can operate high-power or low-power paging systems (only one type per PCMZPM module). For high-power paging, a single amplifier can be used for paging and supplying background music (when not paging). Background music can also be continuously supplied to all zones not being paged with the addition of a second amplifier. For low-power operation, background music is always supplied to zones not being paged. Each module can also be disconnected from the background music bus and connected to a local background music source. Two additional zone modules can be added to the basic system to increase capacity to 9 zones.when more than 9 zones are required, a central processor module with power supply and up to 3 zone modules can be assembled as a satellite system.ten additional 9-zone satellite systems can be installed to bring total capacity to 99 zones. A talkback module (PCMTBM) can also be added to the system to provide hands-free talkback capability. Only one talkback module is required regardless of the number of zones or satellite systems on the PCM2000 system. Relay driver outputs are provided for each zone. Two C-form contact sets are also provided to control the activation of accessory equipment.

Architect & Engineer Specifications* The zone paging system shall be the Bogen PCM2000 Zone Paging System, designed for direct connection to loop start and ground start trunks, to PBX or KEY paging ports which supply DTMF capability, and to analog T/R lines. The unit shall allow total system amplifier power of up to 250W. The unit shall include flanges with keyhole slots for wall-mounted installation. Operation shall require a 12V (1.5A) DC power supply. A suitable power supply shall be provided (PCMPS2 power supply). The system shall consist of the appropriate modules as specified and shall be registered under Part 68 of FCC rules. Modules All modules shall be designed for wall-mounted installation. All modules shall be equipped with a ribbon cable and connector and power cable with connector to permit them to be interconnected to each other. The face plates of each module shall be finished in black, with each control/connector clearly labeled in white. Each face plate shall have knockouts to facilitate cable and wire dressing. All connections shall be made using a small regular screwdriver or common jacks (RJ11 or RCA). The following modules shall be available: PCMTIM - Telephone Interface Module. One PCMTIM module shall be provided per PCM2000 system. The module shall provide for telephone interface selection via built-in DIP switches. It shall include a volume control for tone and BGM source, and RJ11 jacks for night ringer, telephone line, and override.a connector block, using screw terminal connections, shall be provided for BGM source, and two (2) C-form relay contact sets. A power-on LED indicator shall be provided to indicate power-applied status. PCMCPU - Central Processing Module. One PCMCPU module shall be provided for the first nine (9) zones in the system. One PCMCPU module shall be needed for each satellite system. The module shall provide for satellite system identification via built-in DIP switches. It shall include a locking program/run selector switch (with program LED), satellite data link RCA jack, and 12V DC power source jack.a connector block, using screw terminal connections, shall be provided for paging amplification connection, low-power and high-power BGM connections, emergency/shift change signal activation, AUX contact closure, and 12V DC power source connection. A power-on LED indicator shall be provided to indicate power-applied status. PCMZPM - Zone Paging Module. One PCMZPM module shall be provided for each three (3) paging zones in the system. Up to three (3) PCMZPM modules may be connected to the master system, for a total zone capacity of 9 zones. Up to three (3) additional PCMZPM modules may be connected with a PCM- CPU module to form a satellite system to further increase zone capacity. The PCMZPM module shall provide built-in DIP switches to set talkback on/off for each zone. It shall include a power-on LED, low-power background music volume control, background music out/in jumper field, local BGM selection jumpers, and high-power/low-power operation selector switch.a connector block, using screw terminal connections, shall be included to connect local background music, zone wiring, and relay driver outputs. PCMTBM - Talkback Module. One PCMTBM talkback module shall be provided per system (including any satellite systems). The module shall provide for talkback operation in centrallyamplified zones (only). The module shall provide a power-on LED, talkback volume control, and talkback switching delay control. A connector block, using screw terminal connectors shall be included for paging amplification wiring. The PCM Zone Paging System shall supply the following features and functions: 1. Simultaneous high-power and low-power paging.total system high-power audio capacity of 250W. * Architect and Engineer Specifications are available on CD and online in a Word document to assist you with preparing your bids.

Architect & Engineer Specifications, cont. 2. A minimum of three paging zones and maximum zone capacity of ninety-nine (99) paging zones. The system shall be expandable in groups of three zones. 3. Up to 32 field-programmable paging zone groups, each consisting of 1 to 99 zones. 4. Field programmable Night Ringer Zone Group, consisting of from 1 to 99 zones. This feature shall be activated by highvoltage ring signal or contact closure. 5. Field programmable Emergency/Shift change Zone Group, consisting of from 1 to 99 zones. This feature shall require activation by a customer-supplied contact closure, and sound a user-selected tone. The user shall have the choice of no tone (allowing use of outside tone source), tone burst (1-7 sec. duration, user-selected), single chime, or quad beep. 6. Emergency All-Facility Page Override. This feature shall be activated through a loop start trunk or through contact closure and dry audio input. It shall override the normal paging features of the system, sound a user-defeatable alert tone in all zones, and open an audio channel for a voice page. 7. Built-in, talkback amplification of central-amplified zones. This feature shall require the addition of the PCMTBM module. 8. Background music assigned per zone and local background music sourcing capability. 9. Field programmable Code Call Zone Group, consisting of from 1 to 99 zones.the user shall have the choice of pattern or echo code calls, and repeat functions. 10. Eight daily time-triggered signaling events. This feature requires the use of the PCMTBM module. 11. Two (2) C-form relay contact sets for activating external equipment. The contacts shall change state when the unit is activated. 12. Capability of providing uninterrupted background music to all zones not being paged. 13. Non-volatile RAM shall be included to allow for retention of programming information during power interruptions 14. Screwdriver-adjustable volume control of confirmation, preannounce, error, and shift change/emergency-call tones. 50 Spring Street, Ramsey, NJ 07446 201-934-8500 FAX: 201-934-9832 www.bogen.com

BarcodesInc 200 West Monroe Street Chicago, Illinois 60606 Phone: 1-800-351-9962 Fax: 1-312-212-1800 www.barcodesinc.com About BarcodesInc BRANDS Who We Are BarcodesInc is North America's leading provider of p We Owe Our Success To You Why Choose BarcodesInc? Dedicated Account Our Account Managers will not compromise when it comes to providing you top-notch service. Your Account Manager is the primary point of contact for your business and makes it a priority to get to know you, your company and all your needs. Highly-Trained Technical Support Our technical staff has the broadest knowledge and every significant certification in the industry. One of our friendly experts is always available to suggest products and solutions for any situation. Incredible Value Our purchasing power means big savings for you. Whatever your project, our team will work hard to deliver a solution that fits your budget. Largest Inventory in the Industry and Same-Day Shipping Whatever your barcoding, mobile computing, or printing needs, we will fill your order and ship it the same Premier Access to Top Manufacturers BarcodesInc maintains strong strategic partnerships with the leading manufacturers in barcoding, mobile computing, printing and RFID. Responsive Customer Service Every phone call and email is responded to promptly, completely and accurately by our customer service Easy Returns Damaged, defective or incorrectly ordered goods may be returned without hassle. AND MORE BarcodesInc 200 West Monroe Street, Chicago, IL 60606 T: 1-800-351-9962 F: 1-312-212-1800 www.barcodesinc.com