BUSBAR TRUNKING SYSTEMS 25A-63A AB-E SERIES. The smartest way of power distribution.

Similar documents
ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

Multi-conductor Lighting Busbar System A

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

Use RH covers when starting with a LH feed unit or when reaching the LH board. HIGH RATING

IP68 RCP RESIN BUSBAR TRUNKING FOR POWER DISTRIBUTION POWERED BY SPECIALISTS

GLS A GLS 15

Busbar Trunking Assembly

LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range

IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK YEARS+ Established. t. +44 (0) e.

50 YEARS+ A brand of the. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

MISTRAL SYSTEM IMPACT 2

50 YEARS+ HX Range Catalogue. IBAR (EMEA) LIMITED Castle Mills Aynam Road Kendal Cumbria LA9 7DE UK

GROUP MEGABARRE IMPACT. 800A 5000A Abu Dhabi Edition

Busbar Trunking Systems

Powerlink Plus Technical

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Medium power busbar trunking

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Busway Design The Easy Way. By: IIEE-ABU DHABI CHAPTER

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

Electromagnetic Flow Transmitter

Siemens AG CD-L, BD01, BD2 Busbar Trunking Systems up to 1250 A. Catalog LV SIVACON 8PS

Busbar and Modular Wiring Systems

Totally Integrated Power SIVACON 8PS LI busbar trunking system siemens.com/li-system

LR Position Switches TECHNICAL DATASHEET

Low-Voltage Power Distribution and Electrical Installation Technology

Position switches FM series

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers

Low-Voltage Power Distribution and Electrical Installation Technology

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

K Factor Power Transformers

CABLE TRUNKING SYSTEMS

Measuring current transformers of the W, W series

SB 50 Connectors - up to 120 amps

LED Driver Linear / area fixed output

Wire Mesh Cable Tray System for Channeling of Cable Wiring

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

FM series position switches

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

SIVACON 8PS Busbar Trunking Systems

SRS SEALED ROTARY SENSORS

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

INLINE flowmeter for continuous flow measurement

Components for safety applications

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

Laser Safety Curtains Page 1 of 5

Digital flow transmitter for continuous flow measurement

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

TYPE APPROVAL CERTIFICATE

Electrical Power Distribution Low-Voltage Systems SIVACON 8PS busbar trunking systems Installing with LI system

Low-Voltage Power Distribution and Electrical Installation Technology

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Warwick PVC Perimeter Trunking Systems

Safety switches with slotted hole lever

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

Smart Power Relay E I...

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

(1,5 modules per pole)

Collection of standards in electronic format (PDF) 1. Copyright

Pole Line Hardware. Heavy-Duty Spool Rack (200 A) No. of Wires. Anti-Vibration Kit for Spool Rack. Heavy-Duty Spool Rack (400 A) No.

Digital flow ELEMENT transmitter for continuous flow measurement

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

Your passport to success TECHNICAL OVERVIEW

TRANSFORMERS FOR GIS APPLICATIONS VOLTAGE VOLTAGE TRANSFORMERS FOR GIS APPLICATIONS

LED Driver Constant voltage

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

SECTION CABLE TRAYS

Fuse Links NV/NH gg with Striker Pin Dimensions

MULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole

Technical Information itemp TMT180

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

MINI-PS AC/2X15DC/1

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

EC centrifugal fan. forward curved, dual inlet with housing (flange)

KFS. Flap-type flow meter. Design and range of application

Pow-R-Feed Systems Service Manual

Datasheet - ZQ N

Index Pipe Hangers and Straps

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Bar supports. Bar supports

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

SERIESN50, COAXIAL CONNECTORS

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

Medium-voltage transfomers

QUINT-PS-24DC/24DC/10

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Snow Scale SSG. Snow measurement system. Assembly instructions Sommer GmbH. All rights reserved.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SECULIFE SR PC Controllable Instrument for Measuring Safety-Relevant Characteristic Values of Electrical Devices /2.

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Instantaneous Overcurrent Relay

Reduction - RD. Sample Order: 2000A / 1600A, Aluminium, Bolt-on, IP 55, 4 conductors KXA B - RD17. Right Side Feeder "T" Sample Order: B

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Transcription:

BUSBAR TRUNKING SYSTEMS SERIES 25A-63A

TABLE OF CONTENTS SERIES General Information 2-4 Project Information 5-6 Fittings Straight Lengths 7-8 Elbow Modules 8-9 Dilatation Module 9 Top Feed Module 10 End Feed Module 10 Centre Feed Module 11 Tap-Off Plug 11 Tap-Off Unit 12 Flanged End 13 Hanger Kit Hanger 14-18 Technical Data Technical Data 19 Busbar Features 19 Installation Installation 20 Kit Installation 20 Quality Certificates Quality Certificates 21 Certificates 22 2 3

General Features DTM s Series Busbar Trunking System is designed to meet all lighting requirements from 25A to 63A. Technical Data Made of galvanized sheet, the enclosure of the Busbar Trunking System is roll formed for increased mechanical strength. There are 4 PVC insulated conductors: L1, L2, L3 and N+Pe. The cross section of the neutral conductor (optionally 5 conductors) is same as that of the phase conductor. The housing is used for earthing. The Busbar Trunking System is tested and designed according to the standard IEC 61439-1/6. Installation through a cable trunk is possible. Smoke, light intensity, etc. can be controlled using a PLC and a Router. The Busbar Trunking System is manufactured in compliance with the standard ISO 9000 under a certified quality assurance system. Advantages Fittings For an adaptable lighting system, fittings allow for taking optimal advantage of space and for both vertical and horizontal installation. 3-step easy and quick installation: 1. Hangers are placed for hanging the busbars. 2. For connecting two busbars, one busbar is attached to the spring retainer pin. 3. No skilled person or special tool is required for installation. Advantages of the Busbar Trunking System Easy Easy-to-design power distribution, clear network structure and easy engineering and installation Quick With minimum number of tools, quick installation and reduced installation time Flexible Easy-to-extend and modify Plug-In Points The standard distance between two tap-off points is 75 cm. Standard lengths with higher number of plug-in points are available upon request. Colored Covers The tap-off plug covers of DTM s Series Busbar Trunking System are designed in different colors so as to allow for seeing the phase supplied. Tap-Off Plugs and Tap-Off Units The tap-off plugs and tap-off units of DTM s Busbar Trunking Systems are designed with different contact sequences in order to avoid the misuse of the busbar. In order to avoid the misuse of the phase, all tap-off plugs and tap-off units are manufactured so as to allow for unidirectional connection with the busbar. Safety For safety reasons, the first and last members to contact the busbar housing are the earth conductors of the tap-off plugs and tap-off units. Conductor Option In addition to full-section phase and neutral conductors, earth conductors are available upon request. Silver Plated Contact Pins Contact resistances are minimized. 4 5

Order Code System TECHNICAL DETAILS 25 32 40 63 Number of Active Conductors n Cu 2 4 5 5 Busbar Dimensions A x B (mm) 39x57.5 39x57.5 39x57.5 39x57.5 C 12 5 T2 PS Rated Current ln (A) 25 32 40 63 Busbar Cross-Section (3P+N) S (mm 2 ) 3.09 3.09 6.11 12.5 Rated Operational Voltage Ue (V) 400 400 400 400 Rated Insulation Voltage Ui (V) 600 600 600 750 Rated Frequency f (Hz) 50/60 50/60 50/60 50/60 Rated Short-Circuit Current lcw (ka)rms 2.1 2.1 3.1 3.9 BUSBAR NAME Peak Current lpk (ka) 4 4 5 5.35 COPPER (C) Plug-In Busbar Elbow Module PS DM Max. Thermal Limit l 2 (A 2 sx10 ) 0.61 0.61 0.99 7.19 Phase Resistance R 20 (mω/m) 5.64 3.695 2.75 1.273 COPPER CURRENT BUSBAR CODE 25A 12 Plug-In Optional Length Tap-Off Plug Top Feed Module End Feed Module Centre Feed Module Flanged End PX F BM SM OM S Phase Reactance X (mω/m) 1.29 7.909 0.66 0.622 Phase Impedance Z (mω/m) 5.60 3.695 2.81 1.539 Protective Busbar Resistance R PE (mω/m) 1.02 1.02 1.02 0.72 Protective Busbar Reactance X PE (mω/m) 1.08 1.08 1.08 0.075 32A 13 40A 14 63A 16 IP 55 5 Hanger Kit Tap-Off Plug with Automatic Fuse Joint Cover U Hanger C Hanger L Hanger Wall Hanger A SF E UA CA LA DA Fault-Loop Resistance R 0 (mω/m) 6.55 6.55 3.79 2.19 Fault-Loop Reactance X 0 (mω/m) 2.35 2.45 1.92 0.711 Fault-Loop Impedance Z 0 (mω/m) 7.15 7.11 4.25 2.25 Distributed Load Voltage Drop ΔV3F = 3/2 (Rcosø + 2x sinø) 5.66 4.85 2.42 1.29 Linear Busbar Weight p (kg/m) 1.3 1.4 2.42 2.4 Ceiling Hanger TA Fire Load (kwh/m) 0.79 0.79 0.79 0.81 NUMBER OF CONDUCTORS CODE L1 L2 L3 N 1/2 EARTH CLEAN EARTH 1/2 CLEAN EARTH 3P+N+PE (4P) T1 3 3 3 3 3 3P+N+PE+FE1 (5P) T2 3 3 3 3 3 3 EARTH IP 55 55 55 55 Joule Effect Loss in Rated Current P (W/m) 6.9 10.03 13.05 19.9 Ambient Temperature min. / maks. t ( C) -5/+50-5/+50-5/+50-5/+50 6 7

Standard Length Optional Length Plug-In Busbar Standard Length PS Plug-In Busbar Optional Length PX 32 A Copper Plug-In IP55 5 Conductor C135T2PS 25 A Copper Plug-In Optional Length IP55 5 Conductor C125T2PXT Optional lengths are manufactured as 1 mt, 1.5 mt and 2 mt. OPTIONAL LENGTH ORDER CODES LENGTH MM CODE 1000 W 1500 T 2000 L 8 9

Elbow Modules Feeder Modules Elbow Modules DM End Feed Module SM 32 A Copper Horizontal Elbow IP55 5 Conductor C135T2DM 40 A Copper Feeder Module IP55 5 Conductor C145T2SM Top Feed Module BM 25 A Copper Feeder Module IP55 5 Conductor C125T2BM 10 11

Centre Feed Tap-Off Plug Tap-Off Unit With Automatic Fuse Centre Feed Module OM Tap-Off Unit with Automatic Fuse SF 63 A Copper Centre Feed IP 55 5 Conductor C165T2OM Tap-Off Plug F 25 A Copper Tap-Off Plug IP 55 5 Conductor C255T212F AMR. 10 16 25 32 TAP-OFF PLUG PHASE SEQUENCE CODE L1,N,PE 1 L2,N,PE 2 L3,N,PE 3 L1,L2,L3,N,PE 4 L1,N,PE 5 L2,N,PE 6 L3,N,PE 7 L1,L2,L3,N,PE 8 L1,N,PE 9 L2,N,PE 10 L3,N,PE 11 L1,L2,L3,N,PE 12 L1,N,PE 13 L2,N,PE 14 L3,N,PE 15 L1,L2,L3,N,PE 16 32 A Copper Tap-Off Unit IP 55 5 Conductor C325T232SF AMR. 10 16 25 32 TAP-OFF PLUG PHASE SEQUENCE KOD L1,N,PE 17 L2,N,PE 18 L3,N,PE 19 L1,L2,L3,N,PE 20 L1,N,PE 21 L2,N,PE 22 L3,N,PE 23 L1,L2,L3,N,PE 24 L1,N,PE 25 L2,N,PE 26 L3,N,PE 27 L1,L2,L3,N,PE 28 L1,N,PE 29 L2,N,PE 30 L3,N,PE 31 L1,L2,L3,N,PE 32 12 13

Flanged End Joint Covers Busbar and Fittings Hanger Flanged End S 30 mm Hanger (U) UA UA 32 A Copper Flanged End IP 55 5 Conductor 88 mm C135T2S 41 mm 1 2 3 4 Joint Cover E C5T2E 14 15

Busbar and Fittings Hanger Busbar and Fittings Hanger 50 mm Hanger (L) LA 60 mm Hanger (C) CA 118 mm LA 98 mm CA 40 mm 1 2 3 4 1 2 3 4 16 17

Hangers Hangers Wall-Type Hanger DA Hangers T 25 mm 42 mm DA T 59 mm 1 2 Expansion Bolt Extension Member FITTINGS DESCRIPTION W (mm) Code B-E 8 Rod Hanger (M8) 500 T101 B-E 8 Rod Hanger (M8) 1000 T102 (M8) Extension Member - T103 M 8 Draw-In Anchor - T104 M 8 Steel Nut - T105 Ceiling-Type Hanger TA 25 mm TA 59 mm 1 2 W Tij 42 mm 18 19

Busbar Technical Data Installation Instructions Align the pin on the joint of the 1 2 housing with the pin hole of the other housing. Insert the pin into the pin hole. AMPERE RATING 25A 39 COPPER BUSBAR DIMENSIONS AND WEIGHTS BUSBAR mm FEEDER KG 3P+N+PE (4) 3P+N+PE+FE1 (5) 57.5 1.15 1.18 32A 39 57.5 1.19 2.1 X 40A 39 57.5 1.40 1.5 63A 39 57.5 1.48 1.55 3 Jointing of the housing is completed once the pin is inserted into the pin hole. CLICK 4 Place the joint cover and screw the covers together. 5 Jointing is completed once the joint covers are screwed. 20 21

Product Group Manufacturer EC DECLARATION OF CONFORMITY Busbar Power Distribution Systems DTM Elektroteknik San. ve Tic. A.Ş Çatalmeşe Mah. Sultansuyu Cad. No:129 34794 Çekmeköy / Istanbul We hereby confirm that the above-stated product/product group manufactured in DTM s Plants is in conformity with the following standards and directives. Standard TS EN 61439-6 Low-voltage switchgear and control gear assemblies Part 6: Busbar trunking systems (busways) EC Directive (2006/95/EC) Directive relating to electrical equipment designed for use within certain voltage limits Date 15.01.2015 DTM Elektroteknik San. Tic. A.Ş. Çatalmeşe Mah. Sultansuyu Cad. No:129 34794 Çekmeköy / Istanbul Phone: +90(216) 429 51 74 BUSBAR EQUIPMENT LIST TYPE PCS. CATALOG NO COMPANY PROJECT PROJECT NO Please use this page by photocopying 22