Description of CERTO controller Standard

Similar documents
Brief description of KR 15 controllers

Commissioning and Maintenance of Power Factor Correction Systems

NX Series Inverters. HVAC Pocket Programming Guide

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

Operating Instructions

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

Electronic Circuit Breaker ECONOMY REMOTE

Orbital GFI Inverter Series

Mounting Instructions / Manual MV1171

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

USER S MANUAL. Customised to your machine Model: RX 200 V Class Three-Phase Input 0.4 to 55 kw 400 V Class Three-Phase Input 0.

ENS31 Automatic Isolation Unit Product Description

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

General-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Electronic Circuit Breaker BASIC FIX

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8

ENS26 Automatic Isolation Unit Product Description

Computer-14d - xx - 144a

Maintenance instructions

13. Before making a service call Trip information and remedies

returned to your distributor for attention. 14. Do not operate the function switch while the instrument is connected to a circuit.

Cat. No. I528-E1-2 USER S MANUAL SYSDRIVE 3G3JV. Compact Simplified Inverters

3G3JX 200 V V V

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

KNX TH65-AP. Thermo-Hygrometer. Installation and Adjustment. Item number 70184

Please enter the identity code of your device here!

Electronic Circuit Breaker BASIC SMART. - Number of available output channels: 2 / 4 / 8

Please enter the identity code of your device here!

Voltage Relays. Ensuring Reliable Protection for Electrical Systems against Voltage Faults. ISO 9001:2008 Certified.

S11 Adjustable Speed Drive Engineering Specification

QUINT-PS/ 3AC/24DC/10

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Cat. No. I559-E1-02 USER S MANUAL SYSDRIVE MX SERIES. Multi-function Compact Inverter

Operating Instructions. for. Controller SMS 150 / 151

PowerFlex 400 AC Drive Guide Specification

EIB/KNX Switch Actuators. User manual

CROSS Chassis from 160 A to 450 A

MARTINDALE INSTRUCTIONS. E-ZeTest EZ2500 LOOP TESTER ELECTRIC. Trusted by professionals. Other products from Martindale:

Troubleshooting and Maintenance

VF-nC1 Adjustable Speed Drive Engineering Specification

SYSDRIVE 3G3HV Inverter Models The following 200- and 400-V class 3G3HV Inverter models are available.

MP Series Radar Transmitter Installation & Operation Manual

ISOMETER IRDH575. Approvals

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Operating instructions Electronic level sensor LK / / 2008

1 SAFETY INSTALLATION OPERATION COMPONENTS FAULT DIAGNOSTICS FUNCTIONS TECHNICAL SPECIFICATIONS...

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

HZJF-9007 Fully Functional Partial Discharge Inspector USER MANUAL. Huazheng Electric Manufacturing(Baoding) Co.,Ltd

Digital Function Generator

Installation and Operational Instructions for ROBA -switch Type 017._00.2

POWER DISTRIBUTION INDICATOR

Industrial motor controller for brushed DC motors 12 VDC

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

Instruction Manual for Digital Grounding Resistance Meter

UR200SI / UR200WE ENGLISH

Bypass Panels FRENIC-EcoPAK. Fuji Electric Corp. of America FECA-IN-105 / Information subject to change without notice.

Instruction manual for STA 1 sectional door operator

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

LED Driver Compact dimming

S1 Minor (usually reversible) injury S2 Serious (normally irreversible) injury including death

Industrial motor controller for brushed DC motors 24 VDC

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

QUINT-PS/ 1AC/24DC/20

Overview of types. Technical data

This operation manual is intended for users with basic knowledge of electricity and electric devices.

Please enter the identity code of your device here!

Please enter the identity code of your device here!

HLV Instruction & Operations Manual

HLV-350. Instruction & Operations Manual

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

High Frequency Sinewave Guardian TM Filter

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

PHASED OUT. LED Driver Linear / area dimming. Driver LCAI 100W 350mA 900mA ECO INDUSTRY sl ECO series

Instruction manual. art Installation manual

HLV Instruction & Operations Manual. Content

Installation and Operating Instructions for Phase Demodulator Type _.2

THYFREC-VT230S 200V System 0.4 to 90kW 400V System 0.4 to 370kW INSTRUCTION MANUAL

Cat. No. I013-E1-4 USER S MANUAL SYSDRIVE 3G3EV. (Multi-function Models) Compact Low-noise Inverter

Magnetic Inductive Flow Sensor induq

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

This section is specifically about safety matters

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

MultiMeter-Pocket CAT III 1000 V

Awning control system GFM001. Installation and Operating Instructions

6.9 Jump frequency - Avoiding frequency resonance

LED Driver Compact fixed output

Always there to help you. Register your product and get support at AJB4300. Question? Contact Philips.

Challenger 400. Instruction manual

Transcription:

Description of CERTO controller Standard E N E R G Y R E C O V E R Y Page 2 Page 4 Page 6 Page 8 Page 9 Page 11 Page 13 Page 22 Page 26 Page 23 1. Functions of the controller 2. Terminal connection 3. Menu structure overview 4. Menu structure 5. Menu navigation 6. Manual mode / external control / humidity control 7. Factory-set default settings on the controller 8. Fault and error messages 9. Operating messages 10. Safety and warning notices

1. Functions of the controller The following control units are available depending on the pumping capacity: CERTO FU 750 = 750 Watt CERTO FU 1500 = 1500 Watt Special features: 2 the control units can be used worldwide we have followed all the guidelines available to us in the design of the control unit it is therefore the most up-to-date generation of control units the control unit is operated via only three keys. Results and queries are displayed on the illuminated single-line display Once the mains power has been switched on, the control unit is ready for immediate operation if it is connected Faults are shown on the display

most modern processor technology CE approved housing IP 54 short-circuit-proof output EN 55011 tested EN 61000-3 tested EN 61000-4-2 tested EN 61000-4-3 (burst) tested EN 61000-4-4 (surge) tested EN 61800-3 tested each individual module is tested detailed error messages thermal contact monitoring including function display Status message Service indicator Start-up and run-out circuit Menu-guided programming Plain text display via LCD display Three-button operation Third party control signal processing Humidity sensor input Hygiene circuit Operating hours counter Optional accessories: Control range extension Humidity sensor Menu language extension 3

Control signal Maximum relay load 250 V AC 1A 0-10 V 4-20 ma Fault message 1 2 3 4 5 6 Status message Overpressure message Maintenance message Follow-up drying run 7 8 9 10 11 12 2. Terminal connection 4 L1 N S1 S2 S3 S1 and S3 closed during operation.s2 and S3 closed in case of malfunction or power failure L1 N L1 N L1 N { Input 230 V 50 Hz 16 A max. 13 14 15 16 17 18 PE PE PE PE U V W 19 20 21 Solenoid valve supply 22 23 24 2nd level 25 26 27 3rd level 28 29 30 4th level 34 35 36 37 38 39 40 41 42 43 44 45 Regler Wiring of pump station - control unit Wiring of pump station - control unit

Water processing 31 32 33 Solenoid valve purge 46 47 48 min 4 x 1,5 X2 17 18 PE PE U V W PE PE MZ MR N N PE PE 13 14 15 16 2 4 1 4 4 P P 1 1 2 D2 D1 MZ ** 1 2 MZ * M3~ MZ * Solenoid supplypurge MR ** Solenoid valve purge Motor Terminal connections Control unit: 5: Water treatment (+) 6: Water treatment (-) 7: +10 V 8: Controller signal input (+) 9: Controller signal earth (-) 10: Earth 11: Controller enable (+) 12: Controller enable (-) 13: Low pressure switch D1 (+) 14: Low pressure switch D1 (-) 15: High pressure switch D2 (+) 16: High pressure switch D2 (-) 17: Thermal contact motor (+) 18: Thermal contact motor (-) Terminal connections Pump station: 13: Low pressure switch D1 (+) 14: Low pressure switch D1 (-) 15: High pressure switch D2 (+) 16: High pressure switch D2 (-) 17: Thermal contact motor (+) 18: Thermal contact motor (-) Pumpenstation 5

Start Stop Select up Enter Return Select down Maintenance Setting the clock Manual draining 3. Menu structure overview Manual Target Value Manual Mode Language Codeeinput Operating Mode External drive Start Point Humidity control German, French, English, Dutch Humidity target value P-Value I-Value 6

min. frequency Rinse interval Rinse duration max. frequency Frequency limit Drying Drying time Autostart Step switch Switch points 2nd, 3rd, 4th step Store Accelerate time Servicehours Service Reset Decellerate time Line pressure 7

4. Menu structure The control unit has a double-line, multi-colour illuminated display and is operated via 5 keys. Start Stop Only for on-site operation - priority The menu is accessed by pressing the keys simultaneously. Select up Enter Return Select down (Control unit reset): Attention: Error acknowledgement is also carried out via this key combination: Navigation: The left ( ) key: selects the menu item above. The right ( ) key: selects the menu item below. The middle ( ) key: input or acknowledgement. This takes you to the menu item settings that are set with the selection keys and confirmed with the ( ) key. Once the settings are made, move to the next menu item by pressing the Enter key ( ) again. Once the wiring is completed, the device version will appear on the display when the voltage is switched on: B e f e u c h t e r V : K B 5. 0 0 D E F N L 8 If the autostart function is enabled, the following message appears: A c h t u n g!!! A u t o s t a r t!!! If you access the menu during operation, the following message appears: M o t o r S t o p! R I s t f r e q. : x x H z

5. Menu navigation Pressing the three keys ( ) will take you to: S e r v i c e S t d M i T T. M M. J J 1 2 3 9 1 7. 0 6. 1 1 This sets the clock that controls the error log. Pressing, again will open the menu item Manual draining. M a n u a l d r a i n i n g + : S t a r t d r a i n i n Prior to long downtimes, the pump station can be drained via Manual draining. Pressing the left selection key ( ) will open the solenoid valve underneath the water filter. Pressing the Enter key( ), will stop the process, the following menu item appears: S p r a c h e D e u t s c h F r a n c a i s E n g l i s h N e d e r l a n d s Confirm the selection by pressing the Enter key ( ). Next appears: 9

C o d e i n p u t : 0 0 0 0 0 To access the main menu, the code 00111 must be entered. This code request protects against unauthorised access. It is therefore advisable to keep these operating instructions in a safe place. Main menu: Confirming with ( ) takes you to the menu item Operating mode for selecting the control option. O p e r a t i n g m o d e O p e r a t i n g m o d e E x t e r n a l d r i v e O p e r a t i n g m o d e M a n u a l O p e r a t i o n O p e r a t i n g m o d e M o i s t u r e c o n t r o l Depending on the on-site conditions, you can choose between external control via a control signal, manual operation and humidity control (with optional humidity sensor). The operating mode can be changed by pressing the left ( ) and right selection key ( ). After selecting the control option, the entry must be confirmed with the Enter key ( ). 10

6. Manual operation / external control / humidity control Manual operation If Manual operation has been selected, a manual target value between 3 Hz and the factory-set maximum frequency can be specified. The manual target value is set by pressing the selection keys. M a n u a l t a r g. v a l u 0-8 7 H z 2 0 H z Limits Set value This value is confirmed by pressing the Enter key. External control. If External control has been selected, the following display appears: S t a r t p o i n t 0-4 0 % 1 0 % The start point can be set from 0-40% and relates to the control signal. Example: If set at 10%, the control unit will only react to a control signal of 1 Volt. As a result, interfering voltages, which can lead to inadvertent operation of the control unit, are suppressed. 11

Humidity control If Humidity control has been selected, the following display appears: D e s i r e d h u m i t y 1 0-9 5 % 6 0 % Here, the relative humidity the humidifier can achieve is set between 10 % and 95 %. The PI-controller is activated duringhumidity control. This ensures that the set target value remains constant. The Klingenburg humidity sensor is required for this purpose. The gain factor is set here. P - g a i n 0, 2-5, 0 0 0 1, 0 Attention: The value must not be set >1.0, since this could lead to strong sub-harmonics and harmonics. I n t e g r a t o r t i m e 0, 1-1 5 0 s 0 0 1, 0 This controls the reaction time of the control. The greater the time, the slower the control. 12

7. Factory-set default settings on the control unit All factory-set default settings are now displayed, and each setting must be confirmed by pressing ENTER. No changes should be made. M i n i m a l f r e q. 3-2 0 H z 1 0 H z F r e q u e n z b e g r e n z. 2 2 - F m a x 5 0 H z A c c e l e r. t i m e 1-3 0 s e c 1 5 s W a t e r p r e s s u r e S t ö r m e l d. n. 3 0 s W a s h. t i m e 1-1 8 0 0 s 1 8 0 s D r y i n g t i m e 1 5-1 2 0 m i n 3 0 m i n S t e p s w i t c h S t e p s o n M a x i m a l f r e q. 2 2-8 7 H z 6 0 H z A u t o s t a r t f u n k t. A u t o s t a r t o n D e c e l e r. t i m e 1-3 0 s e c 1 0 s W a s h i n t e r v a l 1-9 6 h 4 8 h T r o c k n u n g s f u n k t D r y i n g o n S t e p s w i t c h S t e p s o f f S e r v i c e i n t e r v a l 1 0 0 0 S t d 13

Minimum frequency M i n i m a l f r e q. 3-2 0 H z 1 0 H z The minimum frequency is factory set. The nozzle pressure should be set at a minimum of 5 bar in any humidification situation. Changing this frequency means that humidification is not guaranteed but the humidifier is operating all the same. Controllability is also compromised This setting value is calculated at the factory and preset and checked during a trial run. Frequency range: 3-20 Hz. Changes can cause damage to the humidifier. Maximum frequency M a x i m a l f r e q. 2 2-8 7 H z 6 0 H z F r e q u e n z b e g r e n z. 2 2 - F m a x 5 0 H z 14 The maximum frequency is factory set. The humidifier is designed for a specific humidification capacity. To achieve this value, the complete humidification system is synchronised. This setting value is calculated at the factory and preset and checked during a trial run. Frequency range: 22-80 Hz. Changes can cause damage to the humidifier. Pressing the Enter key ( ) in the setting values of Maximum frequency will take you to the menu item Frequency limit. If excessive humidity occurs or the water consumption is too high, the frequency can be adjusted here. It is important to note that the maximum frequency remains unchanged.

Autostart function A u t o s t a r t f u n k t. A u t o s t a r t o n The Start and Stop button under the display screen has priority. The Autostart on function puts the control unit in Run mode, when menu navigation is completed and after a control unit reset, i.e. if approval is given and a control signal is present, the control unit starts the humidifier up again. If Autostart off is programmed, the control unit must be activated via the Start button ( ). This setting is Start useful for maintenance or during longer downtimes. Power-up time A c c e l e r. t i m e 1-3 0 s e c 1 5 s The power-up time is factory set. This is the time required to reach the designed maximum speed. This is to ensure that the components of the drive system are not put under unnecessary strain. This value is preset at 15 seconds. Years of experience have shown that this can extend the service life. Adjustment range: 1-30 s. Changes can cause damage to the humidifier. 15

Power-down time D e c e l e r. t i m e 1-3 0 s e c 1 0 s The power-down time is factory set. In contrast to the power-up time, this is the time required for the motor to get from maximum speed to zero. Again, the aim is to protect the mechanical components. This value is preset at 10 seconds. Adjustment range: 1-30 s. Changes can cause damage to the humidifier. Line pressure fault message W a t e r p r e s s u r e S t ö r m e l d. n. 3 0 s If several appliances are using the osmosis system and are running simultaneously, the line pressure can drop below 1.6 bar. This causes the humidifier to stop or switch off. In this menu item, the tripping time of the line pressure fault message can be extended (up to 30 minutes) or the fault message can even be switched off (Fault message off). This means that the humidifier is on standby for longer or all the time, when the line pressure is above 2 bar. 16

Rinse interval W a s h. i n t e r v a l 1-9 6 h 4 8 h To ensure hygienic operation of the humidifier, the control unit has an automatic rinsing cycle as standard. The rinse interval is preset at the factory for 48 hours. The value is adjustable between 1 hour and 96 hours. This is the period between two rinsing cycles. Rinsing is activated if the humidifier is enabled via terminals 11 and 12, but no humidification is provided via the control signal or the humidity sensor. Changes lead to increased water consumption and should only be made if bacterial growth due to stagnant water is found during the hygiene inspection. Purge duration W a s h. t i m e 1-1 8 0 0 s 1 8 0 s The time of the actual purge process is adjustable between 10 and 1800 seconds. The factory default setting is 180 seconds. The nozzle assemblies are rinsed for half the set time. Afterwards the solenoid valve under the filter opens and the filter is flushed. 17

Drying run T r o c k n u n g s f u n k t D r y i n g o n D r y i n g t i m e 1 5-1 2 0 m i n 3 0 m i n The control unit is equipped with a delayed shut-off control for drying the humidifier. This function allows an enforced shut-off delay of the ventilation system. During operation and after the pump has been switched off, the floating output is switched on for the set time. Adjustment range: 15-120 min. or off. Step switch For large humidifiers that use a lot of water, it may be useful to switch the nozzle assemblies in groups. In transitional periods when less humidification is required, this can be achieved with fewer nozzles and higher pressure. Depending on the frequency, the nozzle assemblies can be switched on in succession via high pressure solenoid valves. S t e p s w i t c h S t e p s o f f S t e p s w i t c h S t e p s o n 18

S t e p s w i t c h S t e p s o n Up to 3 levels can be switched. 2 n d S t a g e o n 0-8 7 H z 3 0 H z 2 n d S t a g e o f f 0-8 7 H z 2 7 H z... etc.... Reset service message r u. h o u r s : 0 0 x x x h This menu item is only available, if the Service message appears during operation and the recommended oil change intervals have been exceeded. Once the oil change has been carried out, the message can be reset by pressing the left selection key ( ) and confirming with the Enter key ( ), thus initiating a new interval cycle. Proof that the oil change has been carried out must be provided. Attention! Resetting the service message without an oil change will damage the pump and void the warranty. 19

Saving the settings S t o r e d a t a? The changes made must now be saved. This is necessary in order to start the control unit in the selected mode. S t o r e d! Pressing the Enter key ( ) saves the values. N o t s t o r e d! If the changes should not be saved, the action can be cancelled by pressing the selection keys ( ). Messages displayed for different control options during operation For external control: The display (Control signal is present, release enabled) is shown in the event of external control. S o l l f r e q u. : 6 0 H z R I s t f r e q. : 6 0 H z S o l l f r e q u. : 0 0 H z S I s t f r e q. : 0 0 H z 20 R for Run S means stopped via Stop button ( Stop ) Press the Start key ( Start ), to activate autostart.

In manual operation M a n f r e q u. : 2 0 H z R I s t f r e q. : 2 0 H z Started up via the Start button( ) in manual mode. Start Humidity control via humidity sensor F S : 6 0 % F I : 5 8 % R I s t f r e q. : 4 0 H z Humidity control is enabled. Water treatment The CERTO control unit has a relay contact for water treatment. Closing (potential-free) the control terminals 5 and 6, shuts down the water treatment contact and allows a short time in which to dispense an additive into the water of the humidifier. If you open the contact (terminal 5 and 6) the relay drops out. 21

8. Fault and error messages 8.1 Controller disabled C o n t r. b l o c k e d! R I s t f r e q. : 0 0 H z When this message appears in the display, the control unit is externally disabled via terminals 11 and 12. That is to say, the DDC has not enabled the control unit or the connection is faulty e.g. due to loose terminals etc. Generally, the message Controller disabled is not a fault, the controller has merely not been enabled because, for example, the fan was switched off. 8.2 Line pressure W a t e r p r e s s u r e? Message appears when the line pressure drops below 1.6 bar. R I s t f r e q. : 0 0 H z When this message appears on the display, the primary pressure (flow pressure) of the feedwater pipe has dropped below 1.6 bar. The pressure switch sends an enabling signal to the control unit when the pressure reaches 2 bar. If the pressure drops below the minimum limit for a maximum of 30 seconds, the message Line pressure? is displayed. If the pressure rises above 2 bar again during this time, the humidifier starts automatically. If the pressure drops below the minimum limit for more than 30 seconds, a fault message is displayed. This fault can be caused by several factors. The water supply may be switched off or restricted. The water supply pressure drops below 2 bar. The water filter is heavily contaminated. The supply pressure can also drop due to increased flow rate. 22

L e i t u n g s d r k s t ö r! R I s t f r e q. : 0 0 H z Pressing the three buttons ( Fault message after the set tripping time. ) below the display simultaneously, acknowledges the fault message. 8.3 Overpressure S o l l f r e q u. : 5 6 H z R I s t f r e q. : 5 6 H z Overpressure message is displayed! When this message appears on the display, the pressure downstream from the high pressure pump is too high. The high pressure pressure switch is triggered at a pressure of 150 bar, and reduces the speed of the motor. If the pump speed has dropped enough for the pressure switch to turn on again at 135 bar, the control unit saves this frequency and the humidifier returns to operating mode. This saved frequency is stored as the maximum frequency until the fault has been rectified or the control unit has been reset. Since the Klingenburg humidifier continues to operate and the nominal frequency is thus also shown in the display, an overpressure fault is displayed. An overpressure fault can be caused by several factors: the maximum frequency is set too high. the atmomiser nozzles may be dirty, which leads to increased flow resistance. This leads to higher pressure for the same amount of water. 23

8.4 Motor overheating M o t o r t e m p! S I s t f r e q. : 0 0 H z The motor in the pump station is protected against damage from overheating. A thermal contact inside the motor sends a signal to the control unit, causing the motor to switch off and triggering a fault message. 8.5 Service indicator S e r v i c e The Service message appears if the recommended oil change intervals have been exceeded. The first message appears after the first 50 operating hours and then every 1000 operating hours after that. Pressing the Enter key ( ) can suppress the message in order to return to the frequency display. The Service message can be reset in programming mode once the oil change has been carried out. If the Service message is not reset, it will reappear in the display. 8.3 Error codes H a r d w a r e e r r E : x x! The seven possible faults are displayed by the two-digit error code in the second line of the display. 24

01 Excessive voltage (motor / rotor blocked; short circuit between U, V, W) 05 Overload (control unit / motor overloaded) 09 Undervoltage 14 Earth fault 15 Overvoltage 21 Overheating in the final stage, ambient temperature too high; control unit overloaded 99 Software error When the control unit registers a fault, the fault message is displayed in clear text or as hardware error EXX code. In some cases, the humidifier will automatically start up again and continue to run under restricted conditions. The control unit is ready for operation again, when the fault is acknowledged either by switching off the supply voltage or by simultaneously pressing the three buttons. If the humidifier does not start, you should check the following: Line pressure Control signal Controller enable Power supply When all the conditions are met and the humidifier is still not working, please contact the customer service of Klingenburg GmbH. 25

8.7 Communication error C o m m u n i c a t i o n s e r r o r! Communication between the display circuit board and the frequency converter is via a monitored connection. If the connection is faulty, the message appears. The fault is automatically detected and another connection attempt is made. Normally, after a successful attempt at reconnection, the fault is rectified within a few seconds. If the message remains on the display for some time, you should ensure that the connectors on the display s circuit board and the frequency converter are a tight fit, while the control unit is disconnected from the mains. If the message still remains, please contact the customer service of Klingenburg GmbH. 8.8 Software update The special design of the control unit allows the software to be updated at any time. 9. Status messages By pressing the left selection key ( ), the following operating status messages can be displayed successively: 1x : I - M o t : 0 0 3, 4 A R 1 3 : 5 8 0 6. 0 6. 1 1 Motor current, time and date 2x : r u. h o u r s : x x x x x h S e r v. h o u : x x x x x h Operating hours and service hours 26

+ B - Ü - S - T + A 3x : Status display of the 10 relays + H + 2-3 - 4 - R A + in front of the letter equals: Relay output connected A - in front of the letter equals: Relay output open B Ü S T A Status message Overpressure message Maintenance message Follow-up drying run Water treatment H Main valve intake 2 2nd level 3 3rd level 4 4th level R Backflushing 4x : O v e r p r e s s u r e Most recent fault message 5x : 1 1 3 : 5 8 0 6. 0 6. 1 1 Second most recent fault message 6x : Third most recent fault message The three most recent faults are saved. To return to the normal display, press the right selection key ( ) repeatedly. 27

Control unit type CERTO-FU 750 CERTO-FU 1500 Output 0,75 kw 1,5 kw Protection 10 A delayed fuse (5 x 20 mm) internal 16 A delayed fuse required (external) Mains voltage 220-240 Volt / 50-60 Hz 1~ Weight 3500 g 8000 g Ambient temperature Humidity adjustment range (only for humidity control) from -10 C to +40 C (For temperatures below 0 C it is necessary to switch on the unit s mains voltage without running the motor, so that the control unit can warm up) 10% to 95% rel. humidity Protection class IP 54 Output frequency Frequency resolution Control signals Fault alarm relay Motor connection cable 0-80 Hz (factory set as per data sheet) 0,1 Hz 0-10 V, 0-20 ma, 4-20 ma Potential free changeover contact, load capacity 250 V AC, 1 A The connecting cable must always be shielded, for cable lengths over 50 m current limiters should be provided. Please enquire. Dimensions L=256 mm B=232 mm H=128 mm L=355 mm B=262 mm H=168 mm 28

You can enter your settings here: Manual target value Start point Humidity target value Min. frequency Max. frequency Power-up time Braking time Purge interval Purge duration Control factor Drying Level 2 on Level 2 off 29

7. Safety and precautions Before installation and initial operation of the frequency converter, please read through the product handbook carefully and observe all warnings and safety precautions. Make sure that the product manual is easily reachable in the area of the frequency converter. Definition of tips: Warning! Failure to comply with this information could cause death, severe bodily injury or significant physical damage. Caution! Failure to comply with this information could cause minor bodily injury or physical damage. General: During operation it must be ensured that the mains voltage is constantly on. Warning! This frequency converter creates dangerous electrical voltage and controls dangerous rotating parts. Failure to comply with the information in this manual could cause death, severe bodily injury or significant physical damage. The installation, initial operation and maintenance of this drive may only be performed by expert staff that are well versed in the functionality and equipment as well as the machine. The device contains intermediate circuit capacitors that also carry out switchover of dangerously high voltages on the grid side. After switching off the voltage, wait at least 15 minutes before opening the device and working on it. Please be sure that no live parts are touched. The ground fault safety serves only as protection for the frequency converter and not as personal protection. In accordance with VDE 0160 (German abbreviation for the Association for Electrical, Electronic &Information Technologies), the threephase frequency converter must not be operated on a leakage current circuit breaker, because a possible direct current component will reduce the sensitivity of the leakage current circuit breaker in the event of a fault. The provisions of VDE 0160 should be observed as protective measures. Ground the frequency converter to the connection provided for it. To avoid injury and damage, do not touch any parts within the housing not with hands or any kind of object when mains voltage is present or the intermediate circuit capacitor is not loaded. Do not work on wiring or test signals when mains voltage is present. 30

Pay special attention when the automatic restart is activated. To avoid injury from possible uncontrolled restart of the frequency converter after a power outage, install a switch element on the grid side that de-energises in a power outage and can only be turned on after return of voltage by manual confirmation (e.g., contactor, etc.). Ensure that the input voltage corresponds with the voltage listed on the label. Environmental influences such as high temperature and high humidity are to be avoided as well as dust, dirt and aggressive gases. The install location should be a well-ventilated location away from direct sunlight. Install the device on a non-flammable, vertical wall that does not transmit vibrations. Do not connect mains voltage to the output terminals U/T1, V/T2, W/T3. Please contact the motor or machine manufacturer if standard motors with a frequency of > 60 Hz will be operated. All frequency converters are tested for dielectric strength and insulation resistance measurements. Insulation resistance measurements, for example, in the course of inspection, must not be conducted between the power terminals and earth. Do not carry out insulation resistance measurements on the control terminals. During operation it must be ensured that the mains voltage is constantly on. Control commands and operating signals (such as start/stop) must only be implemented via the control terminals or the control panel and not by switching the mains supply or a motor contactor. Do not install capacitors or overvoltage arrestors in the motor lead. Caution! In order to guarantee that your Klingenburg frequency converter operates securely and reliably, all respective safety regulations, such as accident prevention regulations, VDE regulations, etc,. must be observed. As these regulations could contain different details within the German speaking areas, the user must observe the requirements that are valid for their area. Klingenburg GmbH cannot exonerate the user from the obligation to follow the most current safety regulations. The technical data and descriptions in these operating instructions are compiled according to the best of our knowledge and belief. Product improvements are constantly performed. For this reason, Klingenburg GmbH reserves the right to make such changes without prior notice. Despite the careful creation of these instructions, Klingenburg GmbH cannot be held liable for errors or damage which arise from use of this manual. 31

E N E R G Y R E C O V E R Y Klingenburg GmbH Boystraße 115 45968 Gladbeck, Germany Phone: +49-20 43-96 36-0 Fax: +49-20 43-7 23 62 E-mail: klingenburg@klingenburg.de www.klingenburg.de CERTO standard sn 220114 englisch