New. High Performance Inverter. 24A1-E-0042b

Similar documents
New FUJI ELECTRIC INVERTERS

New. High Performance Inverter. 24A1-E-0042e4

New FUJI ELECTRIC INVERTERS

General Specifications FECA-TE /2010. Phone: Fax: Web:

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

FUJI Inverter. Standard Specifications

[ 4 ] Using pulse train input (F01 = 12)

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

IMO Jaguar VXG. Quick Start Guide. Refer to VXG Manual for full data. Available to download from IMO Precision Controls Ltd.

Caution. Three-phase 400V series FRN0.4C1S-4A FRN0.75C1S-4A FRN1.5C1S-4A FRN2.2C1S-4A FRN3.7C1S-4A

ADJUSTABLE SPEED DRIVES. AS1 Drive

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

VF-nC1 Adjustable Speed Drive Engineering Specification

USER'S MANUAL Fuji Electric FA Components & Systems Co., Ltd. MEH278a

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

General Specifications

Fan and Pump AC Inverter

S11 Adjustable Speed Drive Engineering Specification

Series Concepts. Ideal functions to meet various needs. New, compact design. Simple operation. Flexible through optionals

OPC-E1-PG3 Specifications

FRENIC-Ace Specifications for Global Model [GB]

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

(Supplement to Instruction Manual)

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Series Concepts. Ideal functions to meet various needs. New, compact design. Simple operation. Flexible through optionals

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

6.9 Jump frequency - Avoiding frequency resonance

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

FRN E1-4LM FRN E1-7LM

ehvac -ehvac Efficient for Ecology Low Voltage AC Drives for HVAC Applications 24A1-E-0097

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

The new Yaskawa Varispeed G7 Inverter

CHAPTER 8 PARAMETER SUMMARY

TOSVERT TM VF-nC3 Parameter List

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

SX (400 V) System configuration

General Specifications

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

SX (690 V) System configuration

QUICK GUIDE PUMP CONTROL. High performance Compact Inverter. Date Version 22/09/

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

E3 Adjustable Speed Drive Engineering Specification

GS1 Parameter Summary Detailed Parameter Listings...4 9

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

α α Retry count clear Alarm reset Active End of retry S-curve time during accelerati on H04: (Count) setting S curve time during decelerati on

Maximum Engineering for Global Advantage

HPVFP High Performance Full Function Vector Frequency Inverter

Series Concepts -'0+ ) 1!!!! $ ( $ $ # $ 2 ( $!! $ #!! $! $ ( $! # # $ $ 2 3 $! 45 (. ( ) / # 6 $( $ * &7 89 : $ ')8;" : - 2 -

SX (400V) System configuration

AF91 Adjustable Frequency Drives Series B

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Manual Overview...1 2

CTi Automation - Phone: Fax: Web: -

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

9. RS485 Communication

Solar Pumping. Instruction Manual. High Performance Inverter. Jde a

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

ADJUSTABLE SPEED DRIVES FS1

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

General Specifications

STARTING GUIDE FRENIC MEGA. High Performance Multifunction Inverter. 3 ph 400 V 0.4 to 75 kw 3 ph 200 V 0.4 to 55 kw SG_MEGA_GB_1.

9. RS485 Communication (Option)

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Operating Instructions

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

VFS11 Parameter List for up to CPU version 105

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ADTECH Solar inverter

Power Regenerative Converter, THYFREC CV240S

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

ACH550 HVAC Drive Submittal

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

NX series Constant and variable torque Variable Speed Drives for induction motors

Brake resistor can be connected. 150%/1Hz high starting torque by General -purpose magnetic flux vector control. Safety stop function

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

WJ200 series Pursuing the Ideal Compact Inverter

High Performance Compact Inverter User's Manual

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

ehvac Efficient for Ecology Low Voltage AC Drives for HVAC Applications -ehvac 24A1-E-0097

vacon nx all in one application manual ac drives Phone: Fax: Web: -

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup...

MD310 Quick Start Manual. General-Purpose AC Drive

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Inverter Drive /Vector Drive Motors & Controls

High Performance Multifunctional Inverters

CC-Link Compatible AC Servo Amplifier <MR-J3-T type> with Built-in Positioning Function

General Purpose Drives

Multi-function, Compact Inverters. 3G3MV Series

VFS9 Parameter List for Version110 or later

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

PLC-K506 Series FEATURES DESCRIPTION FEATURES

MR-J4-_B-RJ010 MR-J4-_B4-RJ010 MR-J3-T10 SERVO AMPLIFIER INSTRUCTION MANUAL. General-Purpose AC Servo

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

Transcription:

High Performance Inverter New F U J I E L E C T R I C I N V E RT E R S The FRENIC-Ace Inverters are full feature drives offering great value and maintain high performance through optimal design for a wide range of applications for various machines and devices. 24A1-E-0042b

The Next Generation Of Inverters Have Arrived IIntroducing t d i O Our N New St Standard d d IInverter! t! Enjoy A Full Range Of Applications The standard inverter for the next generation, the FRENIC-Ace, can be used in most types of applicationfrom fans and pumps to specialized machinery. 3-phase 400V series Nominal applied motor [kw] 0.4 0.75 1.5 2.2 3.7 5.5 7.5 18.5 22 30 37 45 55 75 90 0 132 160 200 220 0 280 3 Rating condition Application H rating rating Rated output current Model rating Rated output current Model rating Rated output current Model Model rating Rated output current Model Rated output current Coming Soon FRN0022E2 FRN0029E2 FRN0037E2 FRN0044E2 FRN0059E2 FRN0072E2 FRN0085E2 FRN05E2 FRN0139E2 FRN0168E2 FRN0203E2 FRN0240E2 FRN0290E2 FRN0361E2 FRN04E2 21.5A 28.5A 37A 44A 59A 72A 85A 5A 139A 168A 203A 240A 290A 361A 4A FRN0520E2 FRN0590E2 520A 590A Overload current rating Max. ambient temp. 120% -1min 40 C FRN0022E2 FRN0029E2 FRN0037E2 FRN0044E2 FRN0059E2 FRN0072E2 FRN0085E2 FRN05E2 FRN0139E2 FRN0168E2 FRN0203E2 FRN0240E2 FRN0290E2 FRN0361E2 FRN04E2 FRN0520E2 FRN0590E2 17.5A 23A 31A 38A 45A 60A 75A 91A 2A 0A 176A 2A 3A 304A 377A 4A 477A Overload current rating Max. ambient temp. 0% -1min 40 C FRN0022E2 FRN0029E2 FRN0037E2 FRN0044E2 FRN0059E2 FRN0072E2 FRN0085E2 FRN05E2 FRN0139E2 FRN0168E2 FRN0203E2 FRN0240E2 FRN0290E2 FRN0361E2 FRN04E2 FRN0520E2 17.5A 23A 31A 38A 45A 60A 75A 91A 2A 0A 176A 2A 3A 304A 377A 4A FRN0590E2 520A Overload current rating Max. ambient temp. 120% -1min 50 C FRN0022E2 FRN0029E2 FRN0037E2 FRN0044E2 FRN0059E2 FRN0072E2 FRN0085E2 FRN05E2 FRN0139E2 FRN0168E2 FRN0203E2 FRN0240E2 FRN0290E2 FRN0361E2 FRN04E2 FRN0520E2 FRN0590E2 13A 18A 24A 30A 39A 45A 60A 75A 91A 2A 0A 176A 2A 3A 304A 377A 4A Overload current rating Max. ambient temp. 0% -1min, 50 C 200% -0.5sec FRN0030E2S-2 FRN0040E2S-2 FRN0056E2S-2 FRN0069E2S-2 Overload current rating Max. ambient temp. 120% -1min 50 C Fans, pumps Fans, pumps Fans, pumps Wire drawing Wire drawing Vertical conveyance 30A 40A 56A 69A FRN0030E2S-2 FRN0040E2S-2 FRN0056E2S-2 FRN0069E2S-2 A 33A 47A 60A Coming Soon Coming Soon Wire drawing *3-phase 200V series supports only a product for Asia. 2 Rated output current Model 3-phase 200V series rating Overload current rating Max. ambient temp. 0% -1min, 50 C 200% -0.5sec Vertical conveyance Vertical conveyance Winding machines Winding machines Printing machines Printing machines

FUJI ELECTRIC INVERTERS Customizable Logic Customizable logic function is available as a standard feature. FRENIC-Ace has built-in customizable logic functions with a maximum of 200 steps including both digital and analog operation functions, giving customers the ability to customize their invertersfrom simple logic functions to full-scale programming. Fuji Electric also has plans to offer programming templates for wire drawing machines, hoists, spinning machines, and other applications so that the FRENIC-Ace can be used as a dedicated purpose inverter. Major Functions Example: Hoist crane application Programming the FRENIC-Ace main unit with the required logic for controlling a hoist (1) Set speed program (2) Reset the alarm by using the push-button switch (3) Mechanical limit switch function (4) etect load (5) Automatic speed drive when no load is detected (6) Overload stop function Superior Flexibility FRENIC-Ace has readily available interface cards and various types of fieldbus / network to maximize its flexibility. RS485 communications card PG interface (5V) card (Coming Soon) PG interface (12/V) card evicenet communication card CC-Link communication card PROFIBUS-P communication card (Coming Soon) EtherNet/IP communication card (Coming Soon) ProfiNet-RT communication card (Coming Soon) CANopen communication card (Coming Soon) igital input/output interface card Analog input/output interface card al control terminal block RJ5 connector al front face keypad mount edicated/specialized functions for hoist application implemented by using customizable logic Installation type Wide Variety Of Functions As A Standard Feature Sensorless dynamic torque vector control Motor vector control with PG (with optional card) Synchronous motor with sensorless vector control 2-channel on-board RS485 communications port Standard CANopen compatibility Removable keypad device Removable control terminal block board Front face panel Control terminal block 30kW(): option card is built-in s External imensions Terminal Functions Basic Wiring iagram Common Specifications Standard Model Specifications 3

Multi-Function Keypad (option) FRENIC-Ace has two different multi-function keypads available Multi-function keypad with LC display: Enhanced HMI functionality USB keypad: Connect to a computer for more efficient operation (set-up, troubleshooting, maintenance, etc) LAN cable USB USBminiB cable Multi-function keypad with LC screen USB keypad Functional Safety FRENIC-Ace is equipped with STO functional safety function as a standard. Therefore output circuit magnetic contactors are not required for safe stop implementation. Enhanced standard features position FRENIC-Ace ahead of its class (Safety input: 2CH, output: 1CH). Complies with (coming soon) EN ISO 13849-1: 2008, Cat.3 / PL=e IEC/EN 60204-1: 2005/2006 Stop category 0 IEC/EN 608-1 to -7: 20 SIL3 IEC/EN 61800-5-2: 2007 SIL3 (Safety feature: STO) IEC/EN 62061: 2005 SIL3 Years Lifetime esign FRENIC-Ace components have a design life of ten years. A longer maintenance cycle also helps to reduce running costs. esign life Main circuit capacitor Electrolytic capacitors on PCB Cooling fan Life conditions Ambient temperature Load rate * specifications have a rated current of two sizes higher than specifications, so the life is 7 years. years* years* years* +40 C 0% ( specifications) 80% (/H/ specifications) Standards RoHS irective Standard compliance with European regulations that limit the use of specific hazardous substances (RoHS) Global Compliance Standard compliance (cominng soon) <Six hazardous substances> Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), polybrominated biphenyl ether (PBE) EC irectives (CE Mark) UL Standard (cul Certified) <About RoHS> irective 2002/95/EC, issued by the European Parliament and European Council, limits the use of specific hazardous substances in electrical and electronic devices. 4

FUJI ELECTRIC INVERTERS Standard Model Specifications Three phase 400V class series Items Type (FRN E2 E) * (FRN E2SA) H Nominal applied motor *1 [kw] H Rated capacity [kva] *2 Rated voltage [V] *3 Output ratings H Rated current [A] *4, Overload capability H Main power supply Voltage/frequency variations Rated current H without CR *5 [A] Input ratings Rated current H with CR *5 [A] Required power H supply capacity *6 [kva] H Braking torque *7 [%] Braking C braking Braking chopper Braking resistor EMC filter *9 C reactor (CR), H Enclosure (IEC60529) Cooling method Specifications 0022 0029 0037 0044 0059 18.5 22 30 7.5 18.5 22 7.5 18.5 22 5.5 7.5 18.5 16 22 28 34 45 13 18 24 29 34 13 18 24 29 34 9.9 14 18 23 30 Three-phase 380 to 480V (With AVR) 21.5 28.5 37.0 44.0 59.0 17.5 23.0 31.0 38.0 45.0 17.5 23.0 31.0 38.0 45.0 13.0 18.0 24.0 30.0 39.0 120% of nominal current for 1min 0% of nominal current for 1min 0% of nominal current for 1min or 200% of nominal current for 0.5s Three-phase 380 to 480V (With AVR) Voltage: + to -% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%) 33.0 23.2 23.2 17.3 21.1 14.4 14.4.6 7.3 43.8 33.0 33.0 23.2 28.8 21.1 21.1 14.4 20 52.3 43.8 43.8 33.0 35.5 28.8 28.8 21.1 20 20 60.6 52.3 52.3 43.8 42.2 35.5 35.5 28.8 29 20 77.9 60.6 60.6 52.3 57.0 42.2 42.2 35.5 39 29 29 12% % % 20% Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% ( spec.), 0 to 80% (H/ spec.), 0 to 0% ( spec.) of nominal current Built-in Compliant with EMC irectives, Emission and Immunity: Category C3 (2nd Env.) (EN61800-3:2004) IP20, UL open type Fan cooling Mass (Basic Type (EMC Filter Built-in Type)) [kg] 5.0(TB) 5.0(TB) 8.0(TB) 9.0(TB) 9.5(.5) (.2) 0072 37 30 30 22 55 46 46 34 72.0 60.0 60.0 45.0 94.3 77.9 77.9 60.6 68.5 57.0 57.0 42.2 47 39 39 29 s External imensions Terminal Functions Basic Wiring iagram Common Specifications Standard Model Specifications Major Functions *1 Fuji 4-pole standard motor *2 Rated capacity is calculated by assuming the output rated voltage as 440 V. *3 Output voltage cannot exceed the power supply voltage. *4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. spec.---type 0022,0029,0037,0044,0059,0072,0085,05,0139,0168:kHz, 0203 or above type of capacity:6khz spec.---type 0022,0029,0037,0044,0059:kHz, 0072,0085,05,0139,0168:6kHz, 0203 or above type of capacity:4khz H, spec.---type 0022,0029,0037,0044,0059,0072,0085,05,0139,0168,0203 or above type of capacity:4khz The rated output current at H/ spec. is decreased 2% for every 1 C (1.8 F) when ambient temperature is +40 C (+4 F) or more. *5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kva (or times the inverter capacity if the inverter capacity exceeds 50 kva) and %X is 5%. Be sure to use the CR when applicable motor capacity is 75kW or above. *6 Obtained when a C reactor (CR) is used. *7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.) *8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) 67 (IEC 61800-3) If this value is 2 to 3%, use an optional AC reactor (ACR). *9 The EMC Filter Built-in Type supports only a product for EU. * : S: Standard (basic type), E: EMC filter built-in type 5

6 Standard Model Specifications Three phase 400V class series Nominal applied motor *1 [kw] Output ratings Input ratings Braking EMC filter * C reactor (CR) Items Type (FRN E2 E) * (FRN E2SA) Rated capacity [kva] *2 Rated voltage [V] *3 Rated current [A] *4 Overload capability Main power supply Rated current without CR *5 [A] Rated current with CR *5 [A] Required power supply capacity *6 [kva] Braking torque *7 [%] C braking Braking chopper Braking resistor H H Voltage/frequency variations H, H H H H H, H Enclosure (IEC60529) Cooling method Mass (Basic Type (EMC Filter Built-in Type)) [kg] 0085 IP00, UL open type Fan cooling 0139 30(31) 0168 33(33) 0203 40(40) Specifications 0240 45 55 75 90 0 132 160 200 220 280 3 37 45 55 75 90 0 132 160 200 220 0 37 45 55 75 90 0 132 160 200 220 280 30 37 45 55 75 90 0 132 160 200 220 65 80 6 128 5 183 221 275 316 396 450 57 69 85 4 134 160 193 232 287 316 364 57 69 85 4 134 160 193 232 287 316 396 46 57 69 85 4 134 160 193 232 287 316 Three-phase 380 to 480V (With AVR) 85.0 5 139 168 203 240 290 361 4 520 590 75.0 91.0 2 0 176 2 3 304 377 4 477 75.0 91.0 2 0 176 2 3 304 377 4 520 60.0 75.0 91.0 2 0 176 2 3 304 377 4 120% of nominal current for 1min 0% of nominal current for 1min 0% of nominal current for 1min or 200% of nominal current for 0.5s Three-phase 380 to Three-phase 380 to Three-phase 380 to 440V, 50Hz 480V (With AVR) 480V, 50/60Hz Three-phase 380 to 480V, 60Hz *9 Voltage: + to -% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%) 4 140 - - - - - - - - - 94.3 4 140 - - - - - - - - 94.3 4 140 - - - - - - - - 77.9 94.3 4 140 - - - - - - - 83.2 2 138 164 201 238 286 357 390 500 559 68.5 83.2 2 138 164 201 238 286 357 390 443 68.5 83.2 2 138 164 201 238 286 357 390 500 57.0 68.5 83.2 2 138 164 201 238 286 357 390 58 71 96 4 139 165 199 248 271 347 388 47 58 71 96 4 140 165 199 248 271 307 47 58 71 96 4 140 165 199 248 271 347 39 47 58 71 96 4 140 165 199 248 271 5 to 9% 7 to 12% 7 to 12% to % Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% ( spec.), 0 to 80% (H/ spec.), 0 to 0% ( spec.) of nominal current Compliant with EMC irectives, Emission and Immunity: Category C3 (2nd Env.) (EN61800-3:2004) Attached as standard Attached as standard Attached as standard (26) 05 26(27) 62(62) 0290 63(63) 0361 95(95) 04 96(96) 0520 0590 130(130) 140(140) *1 Fuji 4-pole standard motor *2 Rated capacity is calculated by assuming the output rated voltage as 440 V. *3 Output voltage cannot exceed the power supply voltage. *4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. spec.---type 0022,0029,0037,0044,0059,0072,0085,05,0139,0168:kHz, 0203 or above type of capacity:6khz spec.---type 0022,0029,0037,0044,0059:kHz, 0072,0085,05,0139,0168:6kHz, 0203 or above type of capacity:4khz H, spec.---type 0022,0029,0037,0044,0059,0072,0085,05,0139,0168,0203 or above type of capacity:4khz The rated output current at H/ spec. is decreased 2% for every 1 C (1.8 F) when ambient temperature is +40 C (+4 F) or more. *5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kva (or times the inverter capacity if the inverter capacity exceeds 50 kva) and %X is 5%. Be sure to use the CR when applicable motor capacity is 75kW or above. *6 Obtained when a C reactor (CR) is used. *7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.) *8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) 67 (IEC 61800-3) If this value is 2 to 3%, use an optional AC reactor (ACR). *9 The 400 V class series with type 0203 or above is equipped with a set of switching connectors (male) which should be configured according to the power source voltage and frequency. * The EMC Filter Built-in Type supports only a product for EU. * : S: Standard (basic type), E: EMC filter built-in type

FUJI ELECTRIC INVERTERS Standard Model Specifications Three phase 200V class series (Basic Type) Type (FRN E2S-2A) *9 Nominal applied motor *1 [kw] Output ratings Input ratings Braking C reactor (CR) Rated capacity [kva] *2 Rated voltage [V] *3 Overload capability Main power supply Rated current without CR *5 [A] Rated current with CR *5 [A] Required power supply capacity *6 [kva] Braking torque *7 [%] C braking Enclosure (IEC60529) Cooling method Mass [kg] Items Rated current [A] *4 Braking chopper Braking resistor Voltage/frequency variations Three-phase 200 to 240V (With AVR) 0040 7.5 13 40 33 Specifications 120% of nominal current for 1min 0% of nominal current for 1min or 200% of nominal current for 0.5s Three-phase 200 to 240V, 50/60Hz Voltage: + to -% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%) % 20% 0030 7.5 5.5 9.5 30 42.7 31.5 28.8 21.1 7.3 60.7 42.7 42.2 28.8 Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60% ( spec.), 0 to 80% (H/ spec.), 0 to 0% ( spec.) of nominal current Built-in IP20, UL open type Fan cooling *1 Fuji 4-pole standard motor *2 Rated capacity is calculated by assuming the output rated voltage as 220 V. *3 Output voltage cannot exceed the power supply voltage. *4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current. spec.---type 0030,0040,0056,0069:kHz, spec.---type 0030,0040,0056,0069:kHz *5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kva (or times the inverter capacity if the inverter capacity exceeds 50 kva) and %X is 5%. *6 Obtained when a C reactor (CR) is used. *7 Average braking torque for the motor running alone. (It varies with the efficiency of the motor.) *8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) 67 (IEC 61800-3) If this value is 2 to 3%, use an optional AC reactor (ACR). *9 Three phase 200V class series supports only a product for Asia 5.0 5.0 0056 21 18 56 47 80.0 60.7 57.6 42.2 20 8.0 0069 18.5 26 23 69 60 97.0 80.0 71.0 57.6 20 9.0 s External imensions Terminal Functions Basic Wiring iagram Common Specifications Standard Model Specifications Major Functions 7

Common Specifications Items Specifications Remarks Maximum frequency - //H spec.: to 500 Hz variable (V/f control mode, Magnetic pole position sensorless vector control mode) (Up to 200 Hz under vector control with speed sensor) - spec.: to 120 Hz variable (all control mode) IMPG-VC Output Base frequency Starting frequency Carrier frequency Output frequency accuracy (Stability) Frequency setting resolution Speed control range Speed control accuracy Control method Voltage/Frequency characteristic Torque boost to 500 Hz variable (in conjunction with the maximum frequency) 0.1 to 60.0 Hz variable IMPG-VC (0.0 Hz under vector control with speed sensor) Three phase 400V class - Type 0022,0029,0037,0044,0059: - 0.75 to 16kHz variable (//H spec.) - 0.75 to khz variable ( spec.) - Type 0072,0085,05,0139,0168: - 0.75 to 16kHz variable ( spec.) - 0.75 to khz variable (/H spec.) - 0.75 to 6kHz variable ( spec.) - Type 0203 or above type of capacity: - 0.75 to khz variable ( spec.) - 0.75 to 6kHz variable (/H/ spec.) Three phase 200V class - Type 0030,0040,0056,0069-0.75 to 16kHz variable (// spec.) Note: Carrier frequency drops automatically to protect the inverter depending on environmental temperature and output current. (This auto drop function can be canceled.) - Analog setting: ±0.2% of maximum frequency ± C - Keypad setting: ±0.01% of maximum frequency - to +50 C - Analog setting: 0.05% of maximum frequency - Keypad setting: 0.01 Hz (99.99 Hz or less), 0.1 Hz (0.0 to 500.0 Hz) - Link setting: 0.005% of maximum frequency or 0.01 Hz (fixed) - 1 : 00 (Minimum speed : Nominal speed, 4-pole, 1 to 00 rpm) - 1 : 0 (Minimum speed : Nominal speed, 4-pole, to 00 rpm) - 1 : (Minimum speed : Nominal speed, 6-pole, 180 to 1800 rpm) - Analog setting: ±0.2% of maximum frequency or below ± C - igital setting: ±0.01% of maximum frequency or below - to +50 C - Analog setting: ±0.5% of base frequency or below ± C - igital setting: ±0.5% of base frequency or below - to +50 C - V/f control - Speed sensor less vector control (ynamic torque vector control) - V/f control with slip compensation active - V/f control with speed sensor (The PG option card is required.) - V/f Control with speed sensor (+Auto Torque Boost) (The PG option card is required.) - Vector control with speed sensor (The PG option card is required.) - Vector control without magnetic pole position sensor - Possible to set output voltage at base frequency and at maximum output frequency (160 to 500 V). - Non-linear V/f setting (3 points): Free voltage (0 to 500 V) and frequency (0 to 500 Hz) can be set. - Auto torque boost (For constant torque load) - Manual torque boost: Torque boost value can be set between 0.0 and 20.0%. - Select application load with the function code. (Variable torque load or constant torque load) IMPG-VC IMPG-VF PM-SVC IMPG-VC PM-SVC VF IM-SVC(TV) VF with SC IMPG-VF IMPG-ATB IMPG-VC PM-SVC Control Starting torque Three phase 400V class - 200% or above ( spec.:type 0072 or below) / 0% or higher ( spec.:type 0085 or above) at reference frequency 0.5Hz - 120% or higher at reference frequency 0.5Hz, (/ spec.) - 0% or higher at reference frequency 0.5Hz, (H spec.) (Base frequency 50 Hz, with activating the slip compensation and the auto torque boost mode, applied motor is Fuji 4-pole standard motor.) Three phase 200V class - 200% or above ( spec.:type 0069 or below) at reference frequency 0.5Hz - 120% or higher at reference frequency 0.5Hz, ( spec.) (Base frequency 50 Hz, with activating the slip compensation and the auto torque boost mode, applied motor is Fuji 4-pole standard motor.) - Keypad: Start and stop with and keys (Standard keypad) Start/Stop operation - External signals (digital inputs): Forward (Reverse) rotation, stop command (capable of 3-wire operation), coast-to-stop command, external alarm, alarm reset, etc. - Link operation: Operation via built-in RS85 or field bus (option) communications - Switching operation command: Remote/local switching, link switching 8

FUJI ELECTRIC INVERTERS Common Specifications Control Items Specifications Remarks Frequency setting Acceleration/ eceleration time Frequency limiter (Upper limit and lower limit frequencies) Bias for frequency/ PI command Analog input Jump frequency Timer operation Jogging operation Auto-restart after momentary power failure - Keypad: Settable with and keys - External volume: Available to be set with external frequency command potentiometer. (1 to 5 kω 1/2 W) - Analog input: 0 to ± V C (±5 V C)/ 0 to ±0% (terminal [12]) 0 to + V C (+5 V C)/ 0 to +0% (terminal [12]) +4 to +20 ma C/ 0 to 0% (terminal [C1]) +4 to +20 ma C/ -0 to 0 to 0% (terminal [C1]) 0 to +20 ma C/ 0 to 0% (terminal [C1]) 0 to +20 ma C/ -0 to 0 to 0% (terminal [C1]) 0 to + V C (+5 V C)/ 0 to +0% (terminal [V2]) 0 to + V C (+5 V C)/ -0 to 0 to +0% (terminal [V2]) - UP/OWN operation: Frequency can be increased or decreased while the digital input signal is ON. - Multi-step frequency: Selectable from 16 different frequencies (step 0 to ) - Pattern Operation Mode: Automatically run in accordance with the previously configured running time,rotation direction, acceleration/deceleration and reference frequency. Maximum allowable settings are 7 stages. - Link operation: Can be specified via built-in RS85 or Can be specified via bus communicatons. () - Switching frequency setting source: Two of frequency settings source can be switched with an external signal(digital input). Remote/local switching, Link switching - Auxiliary frequency setting: Inputs at terminals [12], [C1] or [V2] can be added to the main setting as auxiliary frequency settings. - Operation at a specified ratio: The ratio can be set by analog input signal. Inverse operation : Switchable from "0 to + VC/0 to 0%" to "+ to 0 VC/0 to 0%" by external command. (terminals [12]/[V2]) : Switchable from "0 to - VC/0 to -0%" to "- to 0 VC/0 to -0%" by external command.(terminal [12]) : Switchable from "4 to +20 ma C/0 to 0%" to "+20 to 4 ma C/0 to 0%" by external command.(terminal [C1]) : Switchable from "0 to +20 ma C/0 to 0%" to "+20 to 4 ma C/0 to 0%" by external command.(terminal [C1]) - Pulse train input (standard): Pulse input = Terminal [X5], Rotational direction = Another input terminal except [X5]. Complementary output: Max. 0 khz, Open collector output: Max. 30 khz - Pulse train input (option):the PG option card is required. CW/CCW pulse, pulse + rotational direction Complementary output: Max. 0 khz, Open collector output: Max. 30 khz - Setting range: From 0.00 to 6000 s - Switching: The four types of acceleration/deceleration time can be set or selected individually (switchable during operation). - Acceleration/deceleration pattern: Linear acceleration/deceleration, S-shape acceleration/deceleration (weak, free (set by function codes)), curvilinear acceleration/deceleration - eceleration mode (coast-to-stop):shut-off of the run command makes the motor coast to a stop. - ACC./EC. time for "Jogging operation" can be set. (0.00 to 6000s) - eceleration time for forcible stop: eceleration stop by the forcible stop (STOP). S-curve will be canceled during "Force to Stop". - Specifies the upper and lower limits in Hz. - Selectable for the operation performed when the reference frequency drops below the lower limit specified by related function code. - Bias of set frequency and PI command can be independently set(setting range: 0 to ±0%). - Gain : Set in the range from 0 to 200% - Off-set : Set in the range from -5.0 to +5.0% - Filter : Set in the range from 0.00s to 5.00 s - Polarity : Select from ± or + - Three operation points and their common jump width (0.0 to 30.0 Hz) can be set. - Operate and stop by the time set with keypad. (1 cycle operation) - Operation with key (standard keypad), or key (multi-functional keypad), or digital contact input FW or REV.(Exclusive acceleration/deceleration time setting, exclusive frequency setting) Analog input between C+1 to +5V is available with analog bias/gain function for input. s External imensions Terminal Functions Basic Wiring iagram Common Specifications Standard Model Specifications Major Functions (Trip at power failure) (Trip at power recovery) (eceleration stop) (Continue to run) (Start at the frequency selected before momentary power failure) The inverter trips immediately after power failure. Coast-to-stop at power failure and trip at power recovery eceleration stop at power failure, and trip after stoppage Operation is continued using the load inertia energy. Coast-to-stop at power failure and start after power recovery at the frequency selected before momentary stop. 9

Control Common Specifications 1st to 2nd motor settings Universal I Universal O Universal AO Items Specifications Remarks (Start at starting frequency) (Start at the searched frequency) Hardware current limiter - Limits the current by hardware to prevent an overcurrent trip caused by fast load variation or momentary power failure, which cannot be covered by the software current limiter. This limiter can be canceled. Software current limiter - Automatically reduces the frequency so that the output current becomes lower than the preset operation level. Operation by commercial power supply - With commercial power selection command, the inverter outputs 50/60 Hz (SW50,SW60). Slip compensation roop control Torque limiter Torque current limiter Overload stopping PI Control Auto-reset Auto search for idling motor speed Automatic deceleration eceleration characteristic (improved braking capacity) Auto energy saving operation Overload prevention control Auto-tuning (off-line) Auto-tuning (on-line) Cooling fan ON/OFF control Speed control Line speed control Positioning control with pulse counter Coast-to-stop at power failure and start at the starting frequency after power recovery. Coast-to-stop at power failure and start at the serched frequency after power recovery. - Compensates the motor slip in order to keep their speed at the reference one regardless of their load torque. - Adjustable compensation time constant is possible. - In a machine driven with multi-motor system, this function adjusts the speed of each motor individually to balance their load torque. Control output torque or torque current so that output torque or torque current are preset limiting value or less. (The torque current limit is only available in IMPG-VC or PM-SVC mode.) - Switchable between 1st and 2nd torque limit values. - "Torque limit" and "Torque current limit" are selectable. - "Torque limit" or "Torque current limit" by analog input. - When detected torque or current exceed the preset value, inverter will decelerate and stop or will coast to stop a motor. - PI processor for process control/dancer control - Normal operation/inverse operation - PI command: Keypad, analog input (from terminals [12], [C1] and [V2]), Multi-step setting(selectable from 3 points), RS85 communication - PI feedback value (from terminals [12], [C1] and [V2]) - Alarm output (absolute value alarm, deviation alarm) - Low liquid level stop function - Anti-reset wind-up function - PI output limiter - Integration reset/hold - The auto-reset function that makes the inverter automatically attempt to reset the tripped state and restart without issuing an alarm output (for any alarm) even if any protective function subject to reset is activated. - The allowable maximum number of reset times for the inverter to automatically attempt to escape the tripped state is 20. - The inverter automatically searches for the idling motor speed to start to drive without stopping. (Motor constants must be needed tuning: Auto-tuning (offline)) - If the C link bus voltage or calculated torque exceeds the automatic deceleration level during deceleration, the inverter automatically prolongs the deceleration time to avoid overvoltage trip. (It is possible to select forcible deceleration actuated when the deceleration time becomes three times longer.) - If the calculated torque exceeds automatic deceleration level during constant speed operation, the inverter avoids overvoltage trip by increasing the frequency. - The motor loss is increased during deceleration to reduce the regenerative energy in the inverter to avoid overvoltage trip. - The output voltage is controlled to minimize the total power loss of the motor and the inverter at a constant speed. - If the ambient temperature or internal IGBT junction temperature is almost near the overheat level due to overload, the inverter drops its output frequency automatically in order to escape overload situation. - Measures the motor parameters while the motor is stopped or running, for setting up motor parameters. - Tuning mode to only identify %R1 and %X. - Tuning mode to identify the parameters for PM motor. - Automatically adjusts motor parameters while the motor is driving in order to prevent the motor speed fluctuation caused by the temperature rise of the motor. - etects inverter internal temperature and stops cooling fan when the temperature is low. - the fan control signal can be output to an external device. - Switchable among the two motors. It is possible to set the base frequency, rated current, torque boost, and electronic thermal slip compensation as the data for 1st to 2nd motors. The status of external digital signal connected with the universal digital input terminal is transferred to the host controller. igital command signal from the host controller is output to the universal digital output terminal. The analog command signal from the host controller is output to the analog output terminal. - Notch filter for vibration control (For IMPG-VC) - Selectable among the four set of the auto speed regulator (ASR) parameters. (The PG option card is required.) In a machine such as winder/unwinder, regulates the motor speed to keep the peripheral speed of the roll constant. (The PG option card is required.) The positioning control starts from the preset start point and counts the feedback pulses from PG inside the inverter. The motor can be automatically started decelerating to the cleep speed which can be detected the target position so that the motor can stop near the position.(the PG option card is required.) IMPG-VC PM-SVC IMPG-VC PM-SVC IMPG-VF Excluded IMPG-VC PM-SVC

FUJI ELECTRIC INVERTERS Common Specifications Control Indicate Operating environment Items Specifications Remarks Master-follower operation Pre-excitation Zero speed control Servo lock C braking Mechanical brake control Torque control Rotational direction control Customizable logic interface Applicable functions for - Wire drawing machine - Hoist - Spinning machine (Traverse) isplay Running/Stopping Maintenance monitor I/O checking Trip mode Light-alarm Running or trip mode Installation location Ambient Ambient humidity Atmosphere Enables synchronous operation of two motors equipped with a pulse generator(pg).(the PG option card is required.) Excitation is carried out to create the motor flux before starting the motor.(the PG option card is required.) The motor speed is held to zero by forcibly zeroing the speed command.(the PG option card is required.) Stops the motor and holds the motor in the stopped position.(the PG option card is required.) When the run command turns OFF and the motor speed fall below the preset C braking starting speed, the inverter starts to inject C current into the motor in order to stop the motor. When the run command turns ON,the inverter starts to inject C current into the motor in order to pre-excite. - The inverter can output the signal which ON/OFF timing adjusted so that the mechanical brake can be turned in conjunction with detected current, torque, frequency, and release/apply delay timers. - Mechanical brake interlock input - Analog torque/torque current command input - Speed limit function is provided to prevent the motor from becoming out of control. - Torque bias (analog setting, digital setting) - Select either of reverse or forward rotation prevention. The digital logic circuits and an analog arithmetic circuits can be chosen and connected with digital/analog input/output signals. The simple relay sequence which the customers demands can be constituted and made to calculate. - Logic circuit (igital) A, OR, XOR, flip-flops, rising/falling edge detection,counters, etc. (Analog) Addition, subtraction, multiplication, division, limitter, absolute value, sign inversion addition, comparison, highest selection, lowest selection, average value, measure conversion. - Multifunctional timer On-delay, off-delay, pulse train, etc. Setting range: 0.0 to 600 s - Input/output signal terminal input / output, inverter control function - Others The 200 steps are available. Each step has 2 inputs and 1 output. The specific functions which is suitable for each application field are realized by customizable logics. etachable with 7 segments LEs (4 digits), 7 keys(prg/reset,func/ata,up,own, RUN,STOP,SHIFT) and 6LE indicator (KEYPA CONTROL,Hz,A,kW,,RUN) Speed monitor (reference frequency, output frequency, motor speed, load shaft speed, line speed, and speed indication with percent), Output current in RMS[A], Output voltage in RMS[V], Calculated torque [%], Input power [kw], PI command value, PI feedback value, PI output, Timer (Timer operation)[s], Load factor [%], Motor output [kw] Torque current [%], Magnetic flux command [%], Analog input[%], Input watt hour [kwh] Constant feeding rate time (set value) (min), Constant feeding rate time (running) (s) - isplays C link bus voltage, Max. Output current in RMS, Input watt-hour, Input watt-hour data, Temperature (inside the inverter and heat sink, Maximum value of each one), Capacitance of the C link bus capacitor, Lifetime of C link bus capacitor (elapsed hours and remaining hours), Cumulative run time of power-on time counter of the inverter, electrolytic capacitors on the printed circuit boards, cooling fan and each motor, Remaining time before the next motor maintenance, Remaining startup times before the next maintenance, Number of startups (of each motor), Light alarm factors (Latest to 3rd last), Contents and numbers of RS85 communications errors, error factors, Number of option errors,rom version of Inverter, Keypad and port. Shows the status of the terminal igital input/output, Relay out, Analog input/output. isplays the cause of trip by codes. Shows the light-alarm display l-al. - Trip history: Saves and displays the cause of the last four trips (with a code). - Saves and displays the detailed operation status data of the last four trips. Indoors Standard (Open Type) - to +50 C (/ spec.) - to +40 C (H/ spec.) NEMA/UL Type 1 - to +40 C (/ spec.) - to +30 C (H/ spec.) 5 to 95%RH (without condensation) Shall be free from corrosive gases, flammable gases, oil mist, dusts, vapor, water drops and direct sunlight. (Pollution degree 2 (IEC60664-1)) The atmosphere must contain only a low level of salt. (0.01 mg/cm2 or less per year) IMPG-VC IMPG-VC IMPG-VC Excluded PM-SVC IMPG-VC s External imensions Terminal Functions Basic Wiring iagram Common Specifications Standard Model Specifications Major Functions

Operating environment Common Specifications Altitude Vibration Items Specifications Remarks 00m or lower If the inverter is used in an altitude above 00 m, you should apply an output current derating factor as listed in below table. Altitude 00m or lower 00 to 00m 00 to 2000m 2000 to 00m 00 to 3000m Three phase 400V class series TYPE:0203 or below 2 to less than 9Hz 3mm:(Max. amplitude) 9 to less than 20Hz 9.8m/s 2 20 to less than 55Hz 2m/s 2 55 to less than 200Hz 1m/s 2 Three phase 200V class series 2 to less than 9Hz 9 to less than 20Hz 20 to less than 55Hz 55 to less than 200Hz Output current derating factor 1.00 0.97 0.95 0.91 0.88 TYPE:0069 or below 3mm:(Max. amplitude) 9.8m/s 2 2m/s 2 1m/s 2 TYPE:0240 or above 3mm:(Max. amplitude) 2m/s 2 2m/s 2 1m/s 2 Storage environment Temperature Relative humidity Atmosphere Atmospheric pressure - to +70 C (in transport) - to +65 C (in storage) 5 to 95%RH The inverter must not be exposed to dust, direct sunlight, corrosive or flammable gases, oil mist, vapor, water drops or vibration. The atmosphere must contain only a low level of salt. (0.01 mg/cm2 or less per year) 86 to 6kPa (during storage) 70 to 6kPa (during transportation) Avoid such places where the inverter will be subjected to sudden changes in temperature that will cause condensation to form. *Note : The meaning of the described abbreviations are shown as follows. VF V/f control IM-SVC(TV) Speed sensorless vector control (ynamictorquevector control) VF with SC V/f control with slip compensation IMPG-VF V/f control with speed sensor (The PG option card is required.) IMPG-ATB V/f control with speed sensor (+Auto Torque Boost)(The PG option card is required.) IMPG-VC Vector control with speed sensor (The PG option card is required.) PM-SVC Magnetic pole position sensorless vector control 12

FUJI ELECTRIC INVERTERS Basic Wiring iagram Standard Terminal Block Board Model Major Functions MCCB or RC/ELCB Power supply 400V series 380V to 480V 200V series 200V to 240V 50/60Hz Auxiliary control power supply Auxiliary fan power supply Enable input Run forward command Run reverse command Select multi-frequency(0 to 1 step) MC igital input Select multi-frequency(0 to 3 step) Select multi-frequency(0 to 7 step) Coast to a stop Reset alarm Common terminal for digital inputs Analog input 3 Potentiometer power supply Voltage input for setting 2 0 to +VC (0 to ±VC) Common terminal for 1 analog inputs (+) Current/voltage input for setting +4(0) to 20mAC / 0 to +VC Ground terminal BR: ynamic Braking Resister CR: C reactor RC: Residual-current-operated protective device ELCB: Earth leakage circuit breaker MC: Magnetic contactor MCCB: Molded case circuit braker (-) In case of the motor with built-in cooling fan Transformer L1/R L2/S L3/T R0 T0 R1 T1 G (EN1) (EN2) (PLC) (PLC) (FW) (REV) (X1) (X2) (X3) (X4) (X5) (CM) [13] [12] SW1 Thermal relay CR (option) (*1) *2 SINK SOURCE Voltage input 12 (0 to + VC) (0 to ± VC) Voltage input V2 (0 to + VC) R FU FV FW P1 C/C Charge lamp +24VC 0V 0V FM Keypad (Standard) +VC BR () (G) 2 1 P B P(+) [] AI PTC SW4 Current input C1 (4 (0) to 20 mac) [C1] PTC thermistor input C SW3 F RJ45 connector V2 C1 0V B N(-) (CM) (THR) (G) (G) Communication port 1 (RS85) BR () P(+) Power voltage switching connector "CN UX" Fan power connector "CN R" / "CN W" U2 U1 FAN NC CN UX CN R CN W SW2 P P(+) R P(+) 30 B B Removable terminal block 2 1 (THR) N(-) Braking unit BU (option) N(-) G connector U V W 30C 30B 30A <Y2> <Y1> <CMY> Current output FMI (4 (0) to 20 mac) Voltage output (0 to + VC) Pulse output FMV FMP [FM] ( to 32 kp/s) SW5 SW6 SW6 X+ X- CAN+ CAN- [] 0V RJ45 connector 2 1 Thermal relay to [C1] to [] (CM) Ground terminal Alarm output (for any fault) Inverter running U V W Common terminal for transistor outputs (SINK/SOURCE) Output frequency 1 Analog output common Communication port2 (RS85) (CAN-BUS) Motor M 3~ PTC Thermistor TH1 THC E Contact outputs Motor overload early warnig Transistor output Analog / pulse output *1 When connecting an optional C reactor (CR), remove the jumper bar from the terminals P1 and P(+). The type 0139 ( spec), 0168 (H spec.) and higher types than 0203 are sure to connect the CR (400V only). Use a CR when the capacity of the power supply transformer exceeds 500 kva and is times or more the inverter rated capacity, or when there are thyristor-driven loads in the same power supply line. *2 The default setting is Source logic for EU model. s External imensions Terminal Functions Basic Wiring iagram Common Specifications Standard Model Specifications NOTE This wiring diagram is to be used as a reference only when using standard terminal block model. When wiring your inverter and/or before applying power, please always follow the connection diagrams and the relevant information written in the User's Manual. 13

Terminal Functions Analog inputs Main circuit Categoly Symbol L1/R, L2/S,L3/T R0, T0 R1, T1 [13] [12] [C1] [] (C1) (V2) (PTC) Name Main circuit power inputs Auxiliary power input for the control circuit Auxiliary power input for the cooling fans Power supply for the potentiometer Analog setting voltage input <Normal operation> <Inverse operation> (PI control) (Auxiliary frequency setting) Analog setting current input <Normal operation> <Inverse operation> (PI control) (Auxiliary frequency setting) Analog setting current input <Normal operation> <Inverse operation> (PI control) (Auxiliary frequency setting1,2) Analog common Analog common (PTC thermistor) Functions Connect the three-phase input power lines. For a backup of the control circuit power supply, connect AC power lines same as that of the main power input. Normally, no need to use these terminals.use these terminals for an auxiliary power input of the fans in a power system using a power regenerative PWM converter. Power supply (+ VC) for frequency command potentiometer (Variable resistor : 1 to 5 kω is applicable). The potentiometer of 1/2 W rating or more should be connected. - External input voltage to be used as a below command. 0 to + VC / 0 to 0% (0 to +5 VC / 0 to 0%) 0 to ± VC / 0 to ±0% (0 to ±5 VC / 0 to ±0%) + to 0 to -VC / -0% to 0 to 0% -V to 0 to +VC / +0% to 0 to -0% -Use as PI command value or PI feedback signal. -Use as additional auxiliary setting to various frequency setting. -External input voltage to be used as a below command. 4 to 20 mac / 0 to 0%/ -0% to 0 to 0% (*1) 0 to 20 mac / 0 to 0%/ -0% to 0 to 0% (*1) 20 to 4 mac / 0 to 0%/ -0% to 0 to 0% (*1) 20 to 0 mac / 0 to 0%/ -0% to 0 to 0% (*1) -Use as PI command value or PI feedback signal. -Use as additional auxiliary setting to various frequency setting. -External input voltage to be used as a below command. 0 to + VC/ 0 to 0% /-0 to 0 to 0% (0 to +5 VC/ 0 to0%) 0 to + VC/ 0 to ±0% /-0 to 0 to 0%(*1) (0 to +5 VC/ 0 to ±0%) + to 0VC/0 to 0%/-0% to 0 to 0% + to 0 VC / 0 to ±0% /-0 to 0 to 0%(*1) (+5 to 0 VC/ 0 to ±0%) -Use as PI command value or PI feedback signal. -Use as additional auxiliary setting to various frequency setting. -PTC thermistor connection to protect the motor overheat. Common terminals for analog input signals [12], [13], [C1], and analog output signals [FM]. The output can be either analog C voltage (0 to VC), analog C current (4(0) to 20 mac) or pulse train ( to 32000 p/s). Any one item can be selected from the following items. Remarks Type 0059 or above (400V only) Type 0203 or above (400V only) U, V, W P(+), P1 P(+), N(-) Inverter outputs For C REACTOR connection For BRAKING UNIT connection/for C bus Connect a three-phase motor. Connects a C REACTOR Connects a braking resistor via the braking unit. Used for a C bus connection system. P(+), B G Braking resistor Grounding for inverter Connect an external braking resistor (option). Grounding terminals for the inverter. Type 0072 or below (400V series) Type 0069 or below (200V series) Maximum supply rating : VC, mac. Input impedance : 22 kω Maximum input level : ± VC Input level is limited among - to VC regardless of excessive input of ± VC. Gain : 0 to 200% Offset : 0 to ±5% Bias : ±0% Filter : 0.00 to 5.00s Input impedance: 0Ω Maximum input 30 mac Input level is limited up to 20 mac regardless of excessive input of 20 mac. Gain: 0 to 200% Offset: 0 to ±5% Bias: ±0% Filter: 0.00 to 5.00s Input impedance: 22kΩ Maximum input ± VC Input level is limited among - to VC regardless of excessive input of ± VC. Gain: 0 to 200% Offset: 0 to ±5% Bias: ±0% Filter: 0.00 to 5.00s This terminal is electrically isolated from terminal [CM], [CMY]. <Voltage output>(*3) 0 to + VC / 0 to 0% (0 to +5 VC / 0 to 0%) Input impedance of the external device: Min. 5kΩ (at 0 to VC output) (While the terminal is outputting 0 to VC, it is capable of driving up to two analog voltmeters with kω impedance.) Analog outputs [FM] Pulse monitor(*3) <Current output>(*3) 4 to 20 mac / 0 to 0% 0 to 20 mac / 0 to 0% Input impedance of the external device: Max. 500Ω (at 4(0) to 20 ma C output) Output form Pulse output: to 32000 p/s at full scale, Pulse duty: approx. 50% Gain: 0 to 300% Monitor data Output frequency1 (Before slip compensation) Output frequency2 (After slip compensation) Output current Output voltage Output torque Load factor Input power PI feedback amount (PV) Actual speed / Estimated speed C link bus voltage Universal AO Motor output Analog output calibration PI command (SV) PI output (MV) Position deviation in synchronous operation(the PG option card is required.) Customizable logic output 1 to Inverter cooling fin temperature PG feedback value (The PG option card is required.) 14

FUJI ELECTRIC INVERTERS Terminal Functions igital inputs Categoly Symbol Name [CM] igital Common [X1] igital input 1 [X2] igital input 2 [X3] igital input 3 [X4] igital input 4 [X5] igital input 5 / Pulse train input [FW] Run forward command [REV] Run reverse command Functions Common terminals for the digital input signals. Select multi-frequency (0 to 1 steps) Select multi-frequency (0 to 3 steps) Select multi-frequency (0 to 7 steps) Select multi-frequency (0 to steps) Select ACC/EC time (2 steps) Select ACC/EC time (4 steps) Enable 3-wire operation Coast to a stop Reset alarm Enable external alarm trip Ready for jogging Select frequency command 2/1 Select motor 2 (M2) Enable C braking Select torque limiter level 2/1 Switch to commercial power (50 Hz) Switch to commercial power (60 Hz) UP (Increase output frequency) OWN (ecrease output frequency) Enable data change with keypad Cancel PI control Switch normal/inverse operation Interlock Cancel torque control Enable communications link via RS85 or fieldbus (option) Universal I Enable auto search for idling motor speed at starting Force to stop Pre-excitation (EXITE) Reset PI integral and differential components Hold PI integral component Select local (keypad) operation Activate the limit switch at start point Start/reset Switch to the serial pulse receiving mode Enter the return mode Enable overload stop Servo lock command Pulse train input Pulse train sign Select torque bias 1 Select torque bias 2 Hold torque bias Check brake control Line speed control Hold the linel speed control frequency in the memory Count the run time of commercial power-driven motor 1 Count the run time of commercial power-driven motor 2 Select droop control Select parameter 1 Select parameter 2 Cancel customizable logic Clear all customizable logic timers Cancel automatic deceleration Run forward command Run reverse command No function assigned PI multistep command 1 PI multistep command 2 Battery / UPS operation -SINK/SOURCE is switchable by using the internal slide switch. -These function codes may also switch the logic system between normal and negative to define how the inverter logic interprets either ON or OFF status of each terminal. -Terminal [X5] can be defined as a pulse train input terminal with the function codes. (Using the PG interface interface card makes the pulse train input function assigned to the inverter's terminal [X5] invalid.) Use exclusively with one digital input. 0 to 30kHz(Open Collector) / 0kHz(Push-pull) Remarks Operation current at ON Source current: 2.5 to 5 ma Source current: 9.7 to 16 ma (terminal [X5])---Pulse train input Voltage level: 2 V or below Operation current at OFF Allowable leakage current: 0.5 ma or less Voltage: 22 to 27 VC s External imensions Terminal Functions Basic Wiring iagram Common Specifications Standard Model Specifications Major Functions

Terminal Functions Categoly Symbol Name Functions Remarks Transistor outputs [PLC] PLC signal power [CM] igital input common [Y1] Transistor output 1 [Y2] Transistor output 2 [CMY] Transistor output common Connect to PLC output signal power supply. This terminal also serves as 24 V power supply. Common terminals for the digital input signals. Inverter running Inverter output on Frequency (speed) arrival signal Frequency (speed) arrival signal 2 Frequency (speed) arrival signal 3 Frequency (speed) detected Frequency (speed) detected 2 Frequency (speed) detected 3 Undervoltage detected (Inverter stopped) Torque polarity detected Inverter output limiting Auto-restarting after momentary power failure eceleration after momentary power failure detected Motor overload early warning Inverter output limiting with delay Keypad operation enabled Inverter ready to run Select AX terminal function (For MC on primary side) Stage transition signal for pattern operation Cycle completion signal for pattern operation Pattern operation stage 1 Pattern operation stage 2 Pattern operation stage 4 Cooling fan in operation Auto-resetting Universal O Heat sink overheat early warning Synchronization completed Lifetime alarm Reference loss detected Overload prevention control Current detected Current detected 2 Current detected 3 Low current detected PI alarm Under PI control Motor stopped due to slow flowrate under PI control Low output torque detected Torque detected 1 Torque detected 2 Motor 1 selected Motor 2 selected Running forward Running reverse In remote operation Motor overheat detected by thermistor Brake signal Terminal [C1] wire break Speed valid Speed agreement PG error detected Low Voltage detected Stop position override alarm Current position count overflowed Positioning completion signal Timer output Maintenance timer Frequency arrival signal Alarm indication 1 Alarm indication 2 Alarm indication 4 Alarm indication 8 Light alarm Alarm output (for any alarm) Enable circuit failure detected Enable input OFF Braking transistor broken Customizable logic output signal 1 Customizable logic output signal 2 Customizable logic output signal 3 Customizable logic output signal 4 Customizable logic output signal 5 Customizable logic output signal 6 Customizable logic output signal 7 Customizable logic output signal 8 Customizable logic output signal 9 Customizable logic output signal Common terminal for transistor output signal terminals. 24 VC (22 to 27 VC), Max. 0 ma This terminal is electrically isolated from terminal []s and [CMY]. allowable range: +22 to +27 VC, 50 ma max. Leakage current 0.1mA or less This terminal is electrically isolated from terminal []s and [CM]s. Relay output [30A], [30B],[30C] Alarm relay output (for any error) -This outputs a non-voltage(dry) contact signal (1c) when the inverter is stopped with the protective function. -As a general-purpose relay output, the same functions as terminal Y can be assigned. -The logic value is switchable between "[30A] and [30C] are excited" and "non-excited." Contact rating: 0 VAC, 0.3 A cosø=0.3 48 VC, 0.5A Contact life: 200000 times (Switching at intervals of one second) Functional safety [EN1], [EN2] [PLC] Enable Input 1 Enable Input 2 PLC signal power Compliance with EN ISO13849-1;2008 Cat.3 PL:e (Pending) -Turning off the circuit between terminals [EN1] and [PLC] or terminals [EN2] and [PLC] stops the inverter's output transistor. (Safe Torque Off: STO) -These terminals are exclusively used for the source mode input and cannot be switched to the sink mode. -If either one of these input terminals is kept OFF for 50 ms or more, the inverter interprets it as a discrepancy, causing an alarm ECF. This alarm state can be cleared only by turning the inverter off and on. Source current at Turn-on : 5-mA Threshold voltage between [PLC] - [EN] : 2V (Turn off) : 22 to 27V (Turn on) leakage current : 0.5mA or less 16