AUTO-SCAN Pen R/C/D Meter for SMD AX-507B USER S MANUAL

Similar documents
HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

1.General instructions Specifications Description...7

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

AMM-1022 Digital Multimeter USER`S MANUAL

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

Sales: Technical: Fax:

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8223A. CAT.IIi 600 V

OPERATOR S INSTRUCTION MANUAL

DMM8900 SERIES USERS MANUAL

CONTENTS MS2033A. 1.Introduction Safety Information...01

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AC/DC CLAMP METER USER S MANUAL

MODEL: D03128 CLAMP METER

Model DIGITAL MULTIMETER

Digital Multimeter, Pen Type

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

R/C SMD Tweezers Multimeter Model RC200

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

KMD-S04 Multímetro de bolsillo

ProfiScale MULTI Multimeter

UT207A/208A/209A Operating Manual. Table of Contents

OPERATOR S INSTRUCTION MANUAL

DIGIT & POINTER MULTIMETER

DVM1190 DIGITAL MULTIMETER

User Manual. All rights reserved. Specifications are subject to change without notice.

Pen-type DIGITAL MULTITESTER

User Manual Digital Clamp Multimeter. model no.: MSR-C600

1. GENERAL INSTRUCTIONS Precaution safety measures Preliminary During use Symbols Instructions 4

True RMS Digital Multimeter Model:

DCM730. Digital Clamp Meter User s Manual

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

Digital Clamp Meter Model: &

Mini Clamp Meter Model:

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

DIGITAL MULTIMETER AUTORANGING

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

1. GENERAL INSTRUCTION Precaution safety measures Preliminary During use Symbols...

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MS2030 CAT III 600 V A V AUTO RS232

User Manual. All rights reserved. Specifications are subject to change without notice.

Model AX-176 INSTRUCTION MANUAL

Model UT10A: OPERATING MANUAL Table of Contents (1)

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

AUTO RANGING DIGITAL MULTIMETER

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Model UT201/202: OPERATING MANUAL. Table of Contents

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

DM-45 Digital Multimeter

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

User Manual Digital Multimeter. model no.: MSR-U1000

Handheld Digital Multimeter PRO-50A

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

Table of Contents GDM-356. Page

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

METRAVI. Table of Contents

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Model UT511 OPERATING MANUAL

IDM 98-III & IDM 99-III Digital Multimeters

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Multifunction Digital

ATK Clamp Meter

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Electrical Multimeter

MS2109A AC/DC Clamp Meter. User Manual. Contents

Model : OPERATING MANUAL Table of Contents (1)

Instruction Manual IDM 66RT Digital Multimeter

UT207/208. Digital Clamp Multimeter P/N:

DIGITAL MULTIMETER OPERATOR S MANUAL

Model: &

312, 316, 318. Clamp Meter. Users Manual

AX-160IP - TOUCH PAD DIGITAL MULTIMETER - USER S MANUAL

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

USER S MANUAL DMR-1500

Title Page Overview Unpacking Inspection Safety Information

Table of Contents Title Page

ET-3888 True RMS Clamp Meter. User Manual

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

DDM350 Pen-Type Digital Multimeter User s Manual

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

AC750 DIGITAL CLAMP METER

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

User Guide. Digital AC/DC Clamp Meter Model 38394

Transcription:

AUTO-SCAN Pen R/C/D Meter for SMD AX-507B USER S MANUAL

1. GENERAL INSTRUCTIONS This auto scan pen R/C/D meter fir SMD could fast precise measure small chip components. To get the best service from this meter, please read this user s manual carefully and observe the detailed safety precautions strictly. 1.1. Precautions safety measures When using this meter the user must observe all normal safety rules concerning 1.1.1. During use Use the meter before must warm-up 30 seconds If the meter is used near noise generating equipment, be aware that display may become unstable or indicate large errors. Do not use the meter if it looks damaged. Use the meter only as specified in this manual; otherwise the protection provided by the meter may be impaired. Do not operate the meter around explosive gas, vapor, or dust. To avoid damages to the instrument, do not exceed the maximum limits of the input values Caution: Avoid working with voltages above 50VDC or 36VAC rms. Such voltages pose a shock hazard and damage the meter When using this meter, keep your fingers away from the metal of the meter. Before changing functions, disconnect the test clip from the circuit under test. Replace the battery when the false display. symbol appears. With a low battery, the meter might produce 1.1.2. Symbols Symbols used in this manual and on thr meter: Caution: refer to the instruction manual. Incorrect use may result in damage to the device or its components. 1.1.3. Instructions Conforms to IEC1010 Before operating the meter, always disconnect from all sources of electric current and make sure you are not charged with static electricity, which may destroy internal components. Any adjustment, maintenance ot repair work carried out on the meter while it is live should be carried out only by appropriately qualified personnel, after having taken into account the instructions in this present manual. If any faults or abnormalities are observed, take the instrument out of service and ensure that it can not be used until it has been checked out. If the meter is not going to be used for a long time, take out the battery and do not store the meter in high temperature or high humidity environment. Never use the meter unless the back cover and battery cover are in place and fastened fully. 2

2. DESCRIPTION 2.1. Instrument Familiarization 1. Cathode 2. Anode 3. RANGE key 4. FUNC KEY 5. LCD DISPLAY 6. Battery cover 2.2. LCD Display 2.3. FUNC. Key-Function key Press this key longer than 1 second, the meter will turn on and enter auto scan mode. Press this key less than 1 second could select the target measurement function. Press the key longer than 2 seconds, the meter will enter sleep mode. 2.4. RANGE key-changes range When automatic mode pressing this key less than 1 second, the meter will enter manual mode. When manual mode pressing this key longer than 1 second the meter will enter automatic mode. While in manual mode, pressing thi key less then 1 second to changes the full-scale range. 3

2.5. Terminals + Terminal receiving the anode - Terminal receiving the cathode Only for measuring the diode and the polar capacitance. 3. TECHNICAL SPECIFICATIONS 3.1. General specifications Environment conditions Pollution degree: 2 Altitiude < 2000m Operating temperature: 0 ~40 C, (<80% C or >28 C) Storage temperature: -10~60 C, (<70%RH, battery removed) Temperature Coefficient: 0,1x(specified accuracy)/vc(<18 C or >28 C) MAX. Voltage between terminals and earth ground: 50V DC or 36V AC rms Sample Rate: 3 times/sec for digital data Display: 2 2/3 digits LCD display with max. reading 2999 5 5/6 digits LCD display with max. reading 5999 Over Range indication: LCD will display OL Low battery indication: The is displayed when the battery is under the proper operation range. Auto power off: If there key been operated for 10 minutes, the meter will auto power off to save battery energy. Power source: 3.0 V battery. Dimension: 181 (L)x35(W)x20(H)mm Weight: 65g. Approx.(battery included) 3.2. Measurement specifications Accuracy: ±(% of Reading + number of digits) at 18 C to 28 ( 64 F to 82 F) with relative humidity to 80% Caution when working with voltages above 50 V DC or 36V AC rms. 3.2.1. Resistance Range Resolution Accuracy 300Ω/600Ω 0.1Ω ±(1.2% of rdg + 2 digits) 3kΩ/6kΩ 1Ω 30kΩ/60kΩ 10Ω 300kΩ/600kΩ 100Ω 3MΩ/6MΩ 1kΩ 30MΩ/60MΩ 10kΩ ±(2.0% of rdg + 5 digits) 4

3.2.2. Capacitance Range Resolution Accuracy 3nF/6nF 1pF ±(5.0% of rdg + 5 digits) 30nF/60nF 10pF ±(3.0% of rdg + 3 digits) 300nF/600nF 100pF 3µF/6µF 1nF 30µF/60µF 10nF ±(5.0% of rdg + 3 digits) 300µF/600µF 100nF 3mF/6mF 1µF 30mF/60mF 10µF unspecified Keep two pins of the capacitance in short before maeasuring 3.2.3. Diode Test Range Desription Test Condition 2V Display read approx. Forward voltage of diode Forward DC Current: approx 1mA. Reversed DC Voltage: approx. 2.8V 3.2.4. Continuity check The buzzer generates 2 KHZ beep whenever the reading is less than 30 Ω. 4. OPERATING INSTRUCTION 4.1. Auto scan measurement mode Pressing this key longer than 1 second the metter will turn on and enter auto mode, now you can measurement: ohm, diode, capatitance, continuity check. Note: The range when auto scan mod: Ohm: 300.0 Ω ~3.000M Ω/600.0 Ω~6.000M Ω Cap: 3nF~300µF/6nF~600µF 5

4.2. Resistance measurement To avoid elecrical Shock or damages to the meter under test, disconnect circuit power and discharge all high-voltage capacitors before measuring resistance Connect the test clip to the object being measured and the measured value will show on the display. Note: When this mode the RANGE key is available. When the input is not connected, i.e. at open circuit, the figure OL will be displayed for the overrange condition. 4.3. Capacitance measurement To avoid electrical Srock or damages to the meter dunder test, disconnect circuit Power and discharge all high-voltage capacitors before measuring capacitance. Keep two pins of the capacitance in short before measuring Connect the test clip to the capacitor being measured and read the displayed value. Note: When this mode the RANGE key is available Discharge the capacitor before measuring 4.4. Diode measurement To avoid elecrical Srock or damages to the meter dunder test, disconnect circuit Power and discharge all high-voltage capacitors before testing diodes. Connect the + pin to the anode, the pin to the cathode of the diode under testing. The meter will show the approx. forward voitage of the diode. If the lead connection is reversed, only figure OL displayed. 6

4.5. Continuity check Connect the test clip to the resistance. If continity exists (i.e., resistance less than 30 Ω) built in buzzer will sound. 5. AUTO POWER OFF(APO) To extend the battery life, Auto Power Off function is provided. If no key operations of range changing happen about 10 minutes, the meter will be turned off automatically. When APO happens the state of the meter is saved. 6. MAINTENANCE 6.1. General Maintenance Periodically wipe the case with a damp cloth mild detergent. Do not use abrasives or solvents. 6.2. Battery replacement Before replacing the battery disconnect test leads from any circuit under test, turn the meter off and remove test Leeds from the input terminals. Use the following procedure: When the battery voltage drop below proper operation range the LCD display and the battery need to be replaced. symbol will appear on the Press the battery cover and towards arrowhead direction to open the battery cover. Replace the battery with two new 1,5 V batteries (AG 13). Replace the battery cover. 7