Proportional amplifier type EV1M3

Similar documents
Proportional amplifier type EV1M3

Electronic amplifier type EV1D

Proportional amplifier type EV22K5

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

Valve amplifier for proportional valves with electrical position feedback

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

ELECTRONIC REGULATOR FOR OPEN LOOP

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Technical Documentation

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Drive Electronics pq11

RT-5005/5006/5007/5008

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Drive electronics pq11

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

12 30 ripple included external fuse 3,0 A Current consumption A 1,0 2,6 depending from solenoid current. V ma. V ma. Output current A 1,0-1,6-2,6

Digital amplifier for proportional valves PEM XD

Installation and Operational Instructions for ROBA -switch Type 017._00.2

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Functional data Factory settings Variable Settings

Continental Hydraulics Installation Manual CEM-PA-A

Analog amplifier RA. RE Edition: Replaces:

RA / /6. Replaces: Table of contents RA /06.98

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Overview of types. Technical data

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

MINI-PS AC/24DC/1.3

Installation and Operational Instructions for ROBA -switch Type 017._00.2

QUINT-PS-24DC/24DC/10

Pulse Scaler for DIN Rail Attachment

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

QUINT-PS/ 3AC/24DC/10

MINI MCR-SL-UI-f(-SP)

Electric amplifier for flow control with proportional

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Continental Hydraulics Installation Manual CEM-RA-A

Accessories Power Amplifiers

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

QUINT-PS AC/24DC/40

Box chopper amplifier BOE

DENISON HYDRAULICS Proportional Pressure Control Valves

Smart Power Relay E I...

Check valve type RK and RB

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

Valve amplifier for proportional pressure valves

Valve amplifier for proportional pressure valves

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

QUINT-PS/ 3AC/24DC/40

Installation and Operating Instructions for Phase Demodulator Type _.2

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Operating Instructions

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

MINI-PS AC/2X15DC/1

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

P5201 Universal Programmable Transmitters with Galvanic Isolation

VariTrans P V. Safe and Sound.

QUINT-PS/ 1AC/24DC/20

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Direct Operated Proportional DC Valve Series D1FP

Hydraulic Valve Interface Products

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

Excitation Systems. Service Generators SIPOL. Transistorized Excitation Systems for Synchronous Generators. Power Generation

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Digital Function Generator

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Coils & Electronic Controls

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Proportional Directional Control Valves Nominal sizes 16 and 25

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Operating Manual Series Load Pins

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Preliminary Product Documentation EV2S-CAN Electronic Amplifier

Operating Instructions

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

For non-electrical quantities

Operating Instructions. for. Controller SMS 150 / 151

Transcription:

Proportional amplifier type EV1M3 Product documentation Modular construction Supply voltage UB: Output current IA: 9...32 V DC max. 2.4 A D 7831/2 11-2014-1.2

by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use and communication of its contents, are forbidden unless expressely permitted. Any breach or infringement will result in liability for damages. All rights reserved concerning patent or utility model application. 2 11-2014-1.2 - D 7831/2 - EV1M3 www.hawe.de 2016

Contents 1 Overview of proportional amplifier type EV1M3... 4 2 Available versions, main data... 5 3 Parameters... 6 3.1 General... 6 3.2 Electrical Data... 6 3.3 Electro-magnetic compatibility (EMC)...7 4 Dimensions... 8 4.1 Amplifier module... 8 4.2 Amplifier module assembled in the card holder...9 5 Installation, operation and maintenance information... 10 5.1 Information on setting... 10 5.2 Setting instructions...11 5.3 Fast adjustment of ramp times...12 5.4 Assembly of the amplifier module on the card holder...13 6 Typical circuits... 14 6.1 Actuation of hydraulic valves using a proportional solenoid... 14 6.2 Controlling hydraulic valves using one twin or two individual proportional solenoids for alternating operation... 15 www.hawe.de 2016 11-2014-1.2 - D 7831/2 - EV1M3 3

1 Overview of proportional amplifier type EV1M3 Proportional ampli ers actuate proportional solenoid valves by converting an input signal into a corresponding control current. The amplifier module EV1M3 can be assembled on a 32 mm or 35 mm DIN rail through the use of an additional card holder. Thanks to the excellent control accuracy and highly precise feedback measurement, even challenging hydraulic applications can easily be realised.a multi-turn potentiometer is used to con gure the valve parameters such as the minimum and maximum current, dither and ramps. A multi-turn potentiometer is used to con gure the valve parameters such as the minimum and maximum current, dither and ramps. Features and bene ts: Compact design Easy commissioning Functions tailored to HAWE-products Intended applications: For the actuation of proportional valves Switch cabinet installation in an industrial setting Figure 1: Proportional ampli er type EV1M3 4 11-2014-1.2 - D 7831/2 - EV1M3 www.hawe.de 2016

2 Available versions, main data Block diagram: 1 Ramp 2 Dither amplitude 3 Intern 4 Enable / Disable 5 Up 6 Down B4, TP3-TP6 are only in use when a coarse adjustment of the ramp times rise and/or fall on the multi-range-potentiometers is carried out by measuring the voltage (see Chapter 5.3, "Fast adjustment of ramp times"). TP1, TP2 test points for measuring the coil (inductive) current 100 mv & 0.5 A The amplifier is suitable for use with all HAWE proportional valves up to 24 V. For the electro-hydraulic remote control of PSL(V) directional spool valves according to D 7770, due to the twin proportional solenoids for the switching positions A and B, it must be ensured that, depending on the control direction, electric switching to the particular solenoid takes place automatically, e.g. by reverser (micro switch) in the remote control hand lever potentiometer, see Chapter 6.2, "Controlling hydraulic valves using one twin or two individual proportional solenoids for alternating operation". Amplifier module Order coding example: Assembly accessories Order coding example: EV 1 M 3 12/24 KM 7831 010 Supply voltage 12/24 V DC (nominal value) Design and development status Internal drawing number Module card holder Basic type Module with screw terminal connections Single-acting prop. solenoid www.hawe.de 2016 11-2014-1.2 - D 7831/2 - EV1M3 5

3 Parameters 3.1 General General data Nomenclature Design Proportional amplifier for 12 V DC to 24 V DC Board (module) with 8-pin screw terminal block Connection leads max. 1.5 mm 2 Fastening Installation position Only possible for 35-mm standard support rails or 32-mm support rails according to DIN EN 60715 in conjunction with a card holder (accessory) Any Weight Total: 80 g Printed circuit board: 40 g Card holder: 40 g Type of protect. DIN VDE 0470, EN 60529 or IEC 529 IP 00 Ambient temperature -20 C...+50 C (up to + 70 C at 75% of the max. output current I A) 3.2 Electrical Data Electrical data Supply voltage U B 9...32 V DC Max. permissible ripple factor w 10% ripple Required lter capacitor C B 2200 μf per 1 A of coil current Output voltage U A U B - 1.2 V DC, pulse-width modulated Output current I A max. 2.4 A short circuit proof protect 6 11-2014-1.2 - D 7831/2 - EV1M3 www.hawe.de 2016

Electrical parameters Setting range I min = 0...1.6 A I max = I min + (0...2.4) A Note I max must never exceed 2.4 A! Factory default setting I min = 0 A; I max = 800 ma No-load current I L max. 20 ma (own consumption) Voltage ranges U nom Can be optionally set as 0...5 V DC, 0...10 V DC or 0...15 V DC Factory default setting 0...5 V DC Reference voltage U St 5 V DC ±4% Input resistance R e >200 kω Recommended potentiometer P 2...10 kω Ramp time rise-fall t R 0.1...10 s Increase and decrease time can be separately adjusted, factory default setting 0.1 s for both Enable/disable input TTL compatible or can be triggered with a contact Dither frequency f 60 or 120 Hz switchable; factory pre-setting 60 Hz Dither amplitude l 0...750 ma (tip to tip), factory default setting 0 ma 3.3 Electro-magnetic compatibility (EMC) The EMC of the device was tested using an accredited testing laboratory (emitted interference according to EN 61000-6-3 and immunity to interference according to EN 61000-6-2 evaluation criterion "B"). The test set-ups only represent typical use. This EMC testing does not release the user from carrying out adequate prescribed EMC testing of their complete system (according to Directive 2004/108/EC). If the EMC of the complete system must be further ampli ed, the following measures can be tested and introduced: The required smoothing capacitor in accordance with Chapter 3.2, "Electrical Data" is not only needed to ensure the device functions correctly, but also to guarantee compliance with EMC guidelines (conducted emitted interference). The equipment should be installed in an metal cabinet (shielding) Supply lines, such as inputs and outputs to and from the device, should be as short as possible. If necessary they should be shielded and twisted in pairs (to reduce the antennae-like effect for increasing the immunity to interference). www.hawe.de 2016 11-2014-1.2 - D 7831/2 - EV1M3 7

4 Dimensions All dimensions in mm, subject to change. 4.1 Amplifier module Potentiometer P6 P7 P8 P9 P10 Potentiometer ramp down time t d (25-turns) Potentiometer ramp up time t u (25-turns) Potentiometer dither amplitude Potentiometer basic current I min (25-turns) Potentiometer maximum current I max (25-turns) Direction of potentiometer rotation Test points Bridges (Jumper) Jumper placed Jumper open TP1 TP2 TP3 TP4 Test point 1 (+) for current feedback measurement, 100 mv 0.5 A Test point 2 (-) for current feedback measurement, 100 mv 0.5 A Test point 3 to adjust ramp UP Test point 4 to adjust ramp DOWN TP5-6 Test points for adjusting the ramp time (see Chapter 5.3, "Fast adjustment of ramp times") Mounting the printed circuit boards B1, B2 and B3 see Chapter 6.1, "Actuation of hydraulic valves using a proportional solenoid" and Chapter 6.2, "Controlling hydraulic valves using one twin or two individual proportional solenoids for alternating operation". a max. 1.8 mm Area for printed circuit board guide and holder (see Chapter 5.4, " Assembly of the amplifier module on the card holder") Note Leave the bridge (jumper) B4 open. Only change B4 to adjust the ramp time (see Chapter 5.3, "Fast adjustment of ramp times"). Plan of terminal connections 1 Enable/disable inout 2 + solenoid 3 0 V earth for solenoid 4 0 V power earth 5 0 V signal earth 6 Reference input 7 U ST stabilized voltage (+5 V DC) 8 +U B supply voltage 8 11-2014-1.2 - D 7831/2 - EV1M3 www.hawe.de 2016

4.2 Amplifier module assembled in the card holder 1 Standardized support bars Description of the amplifier module see Chapter 4.1, "Amplifier module" Assembly see Chapter 5.4, " Assembly of the amplifier module on the card holder". www.hawe.de 2016 11-2014-1.2 - D 7831/2 - EV1M3 9

5 Installation, operation and maintenance information 5.1 Information on setting Note These instructions apply to the target voltage range of 5V using internal stabilized voltage USt = 5 V. Bridges (jumpers) in position as delivered (for other, conceivable bridge positions see Chapter 6.1, "Actuation of hydraulic valves using a proportional solenoid"). Assembly of the amplifier module on the card holder see Chapter 5.4, " Assembly of the amplifier module on the card holder". Note An external target value voltage feed must not be negative. Negative voltage can lead to malfunctions and the destruction of the proportional amplifier. If the maximum target value voltage of 5, 10 or 15 V DC depending on the bridge rectifier is exceeded, the set current I max or I max op. becomes ineffective, i.e., it increases beyond the set limit value. When connecting wires more than 3 metres in length use wires with leads twisted in pairs in order to minimise interference (and therefore to enhace resistance to interference). Maximum coil voltage I max set at the outlet may not in the long run exceed the I lim limit speci ed for the proportional solenoid, since otherwise the solenoid would be subjected to a thermal overload and might break down. It is also possible to introduce solenoids for 12 V in the case of supply voltage with nominal value of 24 V DC of the proportional amplifier. In this case, the supply voltage is converted through the timed output stage, automatically low-loss at a level of 12 V. Advantages: in the entire range of the supply voltage (e.g. from 12 to 32 V DC) the proportional valve operates and the reaction times of the solenoid become shorter; consequently the hydraulics become quicker. Note In the event of interference during the setting procedure or when commissioning, check mains supply. In the case of recti ed bridge configuration: Check whether anelectrolyte lter capacitor of at least 2200 mf/a coil voltage is switched parallel to the supply voltage. Is the supply voltage for the proportional amplifier suf cient? Under load it should be at least approx. 2V DC higher than would be required to generate the maximum current set of I max oper with a warm solenoid coil without a proportional amplifier. 10 11-2014-1.2 - D 7831/2 - EV1M3 www.hawe.de 2016

5.2 Setting instructions F1 V1 Fuse 2.5 A mt Control voltmeter for measuring the coil current, 100 mv 0.5 A 1 Potentiometer Ditheramplitude 2 Potentiometer Ramp up time t u 3 Potentiometer Ramp down time t d 4 Potentiometer max.current I max 5 Potentiometer min. current I min 6 Supply voltage (e.g.: MNG 2,5-230/24 according to D 7835) 7 Target value potentiometer P1; 2-10 kω (e.g. wire potentiometer 5 kω, 2 W) 8 Proportional solenoid 9 Enable / Disable Precondition: The bridges of the amplifier module are provided as part of the delivery. 1. Amplifier connection: Connect the proportional solenoid to terminals 2 and 3. Connect voltmeter V1 to test points TP1 and TP2 (to measure the coil (induction) current). Connect the target value potentiometer (7) to terminals 5, 6 and 7. Connect the supply voltage to terminals 4 and 8. 2. Set the target value potentiometer to minimum (0V). 3. Preset dither amplitude using potentiometer dither amplitude (1). 4. Set ramp times t up time and t down time to minimum using potentiometer ramp up/down time (2) + (3) (turn anticlockwise until it stops). 5. Turn on supply voltage. 6. I min to the minimum current I min op., to which, according to the Q-I or Δp-I characteristic curve of the proportional valve, the desired bottom functional end position corresponds in operation. Adjustable I min range, see Chapter 3.2, "Electrical Data". To read I min op. voltmeter V1 positioned between test points TP1 and TP2 (current value see above). 7. Set target value potentiometer to max. Read target value voltage on the voltmeter V2 (approx. 5V). 8. I max to the maximum current I max op., to which, according to the Q-I or Δp-I characteristic curve of the proportional valve, the desired top functional end position corresponds in operation. Adjustable I max range, see Chapter 3.2, "Electrical Data". 9. Dither frequency f is factory set to 60 Hz via the open bridge B3. In most circumstances this is suf cient. By closing bridge B3 this can be increased to 120 Hz, which can be more suitable for prop. valves of smaller construction. Set the target value potentiometer to approx. 0.5 x I max coil current. Set the dither amplitude (1) by turning the potentiometer dither amplitude clockwise to the right until vibration can just be felt on the proportional valve but does not interfere. 10. Set ramp times t up and t down to the desired time spans. The ramp times always extend beyond the overall range of the output current I A. For details of the shortened setting procedure, see Chapter 5.3, "Fast adjustment of ramp times". 11. Controlling the set functional parameters I min op. (Step 6) for U target = 0 V DC; I max op. (Step 8) for U target = 5 V DC; dither amplitude (Step 10) and ramp times (Step 9). If necessary, repeat setting procedure. www.hawe.de 2016 11-2014-1.2 - D 7831/2 - EV1M3 11

5.3 Fast adjustment of ramp times The ramp times are normally adjusted by trial-and-error. This is the simplest method of adjustment, but it is also very time consuming. The relationship between ramp times and the rotary motions of the trimming potentiometer (25-turn) is not linear. The ramp times can be adjusted accurately (*15%) using a digital voltmeter (minimum 100 kω/v input impedance) and in conjunct with the opposite diagram (refer also to Chapter 4.1, "Amplifier module" und Chapter 5.2, "Setting instructions"): Figure 2: U voltage check voltmeter V1 (V), t ramp time (s) 1. Amplifier: Set jumber B4 and connect supply voltage to terminals 4 and 8 2. Adjusting ramp rise time: Connect TP5 with 5 V (terminal 7), connect voltmeter between TP6. and TP3 read the required voltage for the ramp rise time from the diagram, set voltmeter to this value using the potentiometer. 3. Adjusting the ramp fall time: Connect TP5 with 0 V (terminal 5). Connect voltmeter between TP6 and TP4. Determine the voltage for the required ramp fall time from the diagram and then set on the voltmeter using the ramp fall time potentiometer. 4. Set ramp times t up time and t down time to minimum (potentiometer ramp fall time/rise time anticlockwise until it stops, for a multi-turn potentiometer this is 25 turns) 5. Remove jumper B4 Note The proportional amplifier does not operate if bridge B4 is set! 12 11-2014-1.2 - D 7831/2 - EV1M3 www.hawe.de 2016

5.4 Assembly of the amplifier module on the card holder 5 Centrepiece 6 Card holder, right side 7 Rear trapezoid guid groove for support bar clamp 8 All-round holding groove for module (printed circuit) 9 Support bar clamp 10 Card holder, left side Quick guide 1. Fit together centrepiece of card holder (5) and one of the two side pieces (6) + (10). 2. Insert support bar clamp (9) into trapezoid groove at the back (7). 3. Insert conductor plate into end of all-round holding grove (8). 4. Insert remaining card holder side piece (6) + (10). www.hawe.de 2016 11-2014-1.2 - D 7831/2 - EV1M3 13

6 Typical circuits 6.1 Actuation of hydraulic valves using a proportional solenoid Example A Operation with target value potentiometer F1 = medium-fast fuse; for nominal see Chapter 5.2, "Setting instructions" P1 = target value potentiometer 10 kω, min. 0.1 W Jumpers B1 and B2 tted max. min. Example B Operation with target value changeover switch for both con gured target values I min and I max F1 = as in example A Bridges B1 and B2 set Example C Operation with a priority-dependant target value switch for four target values (relay switch) Typical example of operation: Fast gear 1 - K 1 P1 Fast gear 2 - K 2 P2 Slow gear- K3 P3 Stop - K1 K2 K3 F1 = as in example A Jumper B1 and B2 closed Example D Operation with external target value power source from SPS, CNC or PC Note Pay attention to the maximum load of the power source. 1 Bridge setting for target value voltage ranges 2 Not used 3 Proportional solenoid 4 Supply 5 Enable/block 6 Dither frequency Example E F1 = as in example A Rx = 250 Ω/ 0.5 W Jumper B1 and B2 closed Operation with external target voltage from SPS, CNC or PC Note Whenever the maximum target value voltage of 10V DC (15V DC) is exceeded, the maximum current set will continue to increase! Accordingly, the coil might overheat under excesive power and break down! F1 = as in example A Jumper B2 for 10V DC, do not set jumper for 15V DC voltage 14 11-2014-1.2 - D 7831/2 - EV1M3 www.hawe.de 2016

6.2 Controlling hydraulic valves using one twin or two individual proportional solenoids for alternating operation This mode of operation requires a remote-control potentiometer for central alignment and side recognition of two positively connected direct switches SB 1 and SB 2 for solenoid coils 1 and 2. Example F: Controlling a proportional directional valve type PSL or PSV as speci ed in D 7700-ff. F1 As in example A P1 Potentiometer with xed central alignment, 2x5 kω R 31V varistor, such as Siemens SIOV S05K25 or SIOV S10K25 (against radio inteference or excess voltage) Jumpers B1 and B2 (ref. voltage 5V DC) are placed, B3 open S1B and S2B Directional switches are included in the control gear for one axle 1 Power supply 2 Proportional twin solenoid or pair of individual proportional solenoids 3 Enable / Disable www.hawe.de 2016 11-2014-1.2 - D 7831/2 - EV1M3 15

Further information Additional versions Electronic amplifier type EV1D: D 7831 D Proportional amplifier type EV22K2: D 7817/1 CAN node type CAN-IO: D 7845 IO Programmable logic valve control with Pro bus type PLVC 21: D 7845-21 Programmable logical valve control type PLVC 41: D 7845-41 Programmable logic valve control type PLVC 8: D 7845 M Application Proportional directional spool valve, type PSL and PSV size 2: D 7700-2 Proportional directional spool valve, type PSL, PSM and PSV size 3: D 7700-3 Proportional directional spool valve, type PSL, PSM and PSV size 5: D 7700-5 Directional spool valve type NSWP 2: D 7451 N Clamping module type NSMD: D 7787 Directional seated valve type EM and EMP: D 7490/1 11-2014-1.2 - D 7831/2 - EV1M3 HAWE Hydraulik SE Streitfeldstraße 25 81673 München Postfach 80 08 04 81608 München Germany Tel +49 89 379100-1000 Fax +49 89 379100-9100 info@hawe.de www.hawe.com