We a r i n g m ag n i f y i n g loupes is b e c o m i n g standard

Similar documents
Why sharpen dental hygiene instruments? When to sharpen dental hygiene instruments?

Lab: The Compound Microscope

Instructions. To run the slideshow:

INDIAN SCHOOL MUSCAT SENIOR SECTION DEPARTMENT OF PHYSICS CLASS X REFLECTION AND REFRACTION OF LIGHT QUESTION BANK

THE ONLY PORTABLE, AFFORDABLE INSTRUMENT OFFERING THREE-DIMENSIONAL VIEWING AND ILLUMINATION INTO A SMALL CAVITY.

GYN Scissors - Z-Type Hysterectomy & Parametrium

Lab 12. Optical Instruments

Extensive cable management on a footprint that fits on a 24-inch floor tile.

PHY 1160C Homework Chapter 26: Optical Instruments Ch 26: 2, 3, 5, 9, 13, 15, 20, 25, 27

LOUPES LIGHTS VIDEO CAMERA

Microscope Tutorial. How to use a compound microscope

anchor surgical needles and other OR related products

Lab 11: Lenses and Ray Tracing

Activity 6.1 Image Formation from Spherical Mirrors

2. The radius of curvature of a spherical mirror is 20 cm. What is its focal length?

Name: Lab Partner: Section:

INSIDE LAB 6: The Properties of Lenses and Telescopes

These 15U, 22U, 37U, 42U, and 51U racks provide exceptional stability.

Maximum Recommended Load (lbs.) Grounding Procedure. Short Regular Duty ALUMA-FORM Platforms (3 5-1/8 wide) PLATFORMS

Loupe and LED Illumination Systems. The Lightness of Seeing

Family of Stereo Microscopes Quality microscopes for industry and life sciences


Geometric Optics. Objective: To study the basics of geometric optics and to observe the function of some simple and compound optical devices.

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Basic Principles of the Surgical Microscope. by Charles L. Crain

Snell s Law, Lenses, and Optical Instruments

Century focus and test chart instructions

BLIPS perfectly aligned cleaned by any impurity Gently press the lens

Total Performance System THE ESSENCE OF POWER AND VERSATILITY IN A UNIVERSAL SURGICAL SYSTEM NEURO SPINE ENT SPORTS MED PLASTICS GEN.

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

SPECIFICATIONS. The WM-6XL Long Wm. Malcolm Telescopic Riflescope Instruction Manual WARNING:

Stereo Viewing Systems

Geometric Optics. This is a double-convex glass lens mounted in a wooden frame. We will use this as the eyepiece for our microscope.

Q5 VET. Compact, Affordable Color Doppler for VET

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

User Manual. Trinocular Infinity Compound LED Microscope. MicroscopeNet.com

PlaneWave CDK Telescope Instructions. Setting the spacing and collimation for the CDK14/17/20/24

(Shown on Short Riser) Power Button. Elevation. Eyepiece. Adjustment. Objective Lens. Windage. Adjustment. Battery Compartment

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life.

O W N E R ' S M A N U A L

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Introduction. Laboratory Equipment & Supplies. Model 1333PHi Shown (Phase Contrast) (2) Eyepieces (Eyecups installed) Diopter Adjustment Mechanism

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

Chapter 2 Alignment C. Robert Bagnell, Jr., Ph.D., 2012

Laboratory Introduction

NORTHERN ILLINOIS UNIVERSITY PHYSICS DEPARTMENT. Physics 211 E&M and Quantum Physics Spring Lab #8: Thin Lenses

WARNING Kia Spectra 5 Installation Instructions BX2713. Serial Number

PC-4000 Digital Panoramic Imaging System

Marine Invertebrate Zoology Microscope Introduction

Ceiling Mount - 32" to 60" - Single Installation Instructions

MrN Physics Tuition in A level and GCSE Physics AQA GCSE Physics Spec P3 Optics Questions

LENSES. A lens is any glass, plastic or transparent refractive medium with two opposite faces, and at least one of the faces must be curved.

AN INTRODUCTION TO THE MICROSCOPE

E Series *TD * Quick Start Guide. Input Configuration. E Series E110, E12, E15, E215 Block Diagram and Input Plate

Protist Microscope Lab

THE TELESCOPE. PART 1: The Eye and Visual Acuity

WARNING Kia Spectra Installation Instructions BX2711. Serial Number

ASSEMBLY INSTRUCTIONS. enook Pro

!"#$%&$'()(*'+,&-./,'(0' focal point! parallel rays! converging lens" image of an object in a converging lens" converging lens: 3 easy rays" !

Converging Lens. Goal: To measure the focal length of a converging lens using various methods and to study how a converging lens forms a real image.

Microscopes. A guide to use, general Maintenance, and repair tailored to the Olympus CX-21 microscope

Optics Review. 2. List the different types of Light/EM Radiation in order of increasing wavelength.


Copyright Black Box Corporation. All rights reserved.

Care and Use of the Compound Light Microscope

STILLE Micro Instruments. Solid Performance - Outstanding Precision

Ambient Weather EZ Stable Mounting Kit with Mast for AcuRite Weather Stations User Manual

Installing Brackets to Minimize Distortion in Your SMART Board 685ix Interactive Whiteboard System s Projected Image

Light - Reflection and Refraction

Complete the diagram to show what happens to the rays. ... (1) What word can be used to describe this type of lens? ... (1)

Version Number_1.8(English Version) Copyright 2011 by Aumed, All rights reserved. Aumed Group Corp.

pottery barn kids MADISON CABINET HUTCH

EYELINE OPTICAL STENERSEN FRAME GAUGE INSTRUCTIONS

Versa Lift AS24 - Auto-Shutter Installation Guide

WARNING Honda CR-V Honda Element Installation Instructions BX2232. Serial Number

Division C Optics KEY Captains Exchange

History of microscopy

AUG 15 Rev M

Plexidor Glass Conversion Pet Door Consumer Instructions

Binoculars Bonanza! Overview Students will explore the bird world through binoculars and learn basic bird identification strategies.

WARNING Acura TSX Installation Instructions. B as e plate s BX1012. Serial Number

EXTENDED CARE SEATING Comfort Versatility Durability

Physics 208 Spring 2008 Lab 2: Lenses and the eye

MMBZxxVAWT1G Series, SZMMBZxxVAWT1G Series. 40 Watt Peak Power Zener Transient Voltage Suppressors. SC 70 Dual Common Anode Zeners for ESD Protection

NEWTOM GO 2D GREAT.VISION

Integra. Capture Screw System SURGICAL TECHNIQUE

AGES 10+ INSTRUCTION MANUAL. 800x Power Advanced Microscope Biological Experiments Gear. x 2 NOT INCLUDED

LENSES. a. To study the nature of image formed by spherical lenses. b. To study the defects of spherical lenses.

Collection. For metal & acetate & injection frames. For metal & acetate & wood frames. For acetate & special material frames

Chapter 34. Images. Copyright 2014 John Wiley & Sons, Inc. All rights reserved.

Geometric Optics. Ray Model. assume light travels in straight line uses rays to understand and predict reflection & refraction

Lab 2 Geometrical Optics

Ambient Weather EZ Weather Station Tripod and Mast Assembly for AcuRite Weather Stations User Manual

mirrors and lenses PHY232 Remco Zegers Room W109 cyclotron building

788XL Dado Jig Owners Manual Please Read Carefully!

E Series *TD * Quick Start Guide. Input Configuration. E Series E10, E12, E15 Block Diagram and Input Plate

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

Reflex TM Surgical Technique. Anterior Cervical Plate

Microscope. & Measurements. Do Now

There is a range of distances over which objects will be in focus; this is called the depth of field of the lens. Objects closer or farther are

Transcription:

Lou p e s

loupes We a r i n g m ag n i f y i n g loupes is b e c o m i n g standard a m o n g clinicians. For additional information, to schedule an in-office demonstration, or to place an order, please contact your local Miltex authorized Distributor or Miltex Customer Service at 866.854.8300, e-mail: customerservice@miltex.com or visit us at www.miltex.com.

loupes Milt e x Lo u p e s for the Surgeon Animal Health Clinician Dentist Dental Hygienist Milt e x Op t i c s Feat u r e s a n d Be n e f i t s Miltex optics are quickly and easily locked into your personal setting utilizing Set and Forget technology. Our optics permit you to set your interpupillary distance, convergence and declination angle for perfect alignment. You get a custom fit even without individual measurement! Features Set and Forget Optics Dual Hinge Design Locking Interpupillary Knob Double locking convergence angle Benefits Optics are quickly and easily locked into place Allows for easy flip up of optics Allows for secure adjustments of your settings Provides stable alignment of optics

Choosing The Right Loupe follow these 2 steps for a perfect match. Step 1: Choose your magnification. If you are a new loupe user, start with the lowest power you need. Most professionals begin using loupes with a magnification power of 2.5X. Remember, as the magnification increases, the field of view, focal range and light transmission decreases. Step 2: Choose your working distance. All loupes are pre-set to focus at a certain distance and objects will remain in focus within a range of several inches. Miltex loupes are available in 4 working distances: Short (10-13"), Regular (12-16"), Long (14-18") and Extra Long (16-20"). The 250 Series (2.5X) is the ideal general purpose optic. The 250 series optic will provide a magnified view of approximately 2.5 times the object size. Most first time loupe users choose this magnification. The 300 Series (3.0X) is an ideal optic for those who have worked with a 2.5x magnification power optic and want an increase in power. The 300 series optic provides a view of the entire area of focus and has an excellent depth of focus. The 350 Series (3.5X) is the highest magnification optic available in a compound lens design. The 350 series optic is an excellent choice for dentists and surgeons requiring high magnification in a lightweight loupe. Suggested Loupe Guide Discipline Your Height under 5'7" 5'7" to 6'4" over 6'4" Cardiac 3.0x/3.5x - Long 3.0x/3.5x - Long 3.0x/3.5x - X-Long General Surgery 2.5x - Long 2.5x - X-Long 2.5x - X-Long Maxillofacial 3.0x - Regular 3.0x - Long 3.0x - Long Neuro Surgery 2.5x/3.5x - Long 2.5x/3.5x - X-Long 2.5x/3.5x - X-Long Ophthalmology 2.5x/3.0x - Regular 2.5x/3.0x Long 2.5x/3.0x - Long or X-Long Orthopedics (sitting) 2.5x- Regular 2.5x - Long 2.5x - X-Long Orthopedics (standing) 2.5x - Long 2.5x - X-Long 2.5x - X-Long Plastics (sitting) 3.0x - Regular 3.0x - Long 3.0x - Long Plastics (standing) 3.0x - Long 3.0x - Long 3.0x - X-Long Urology 2.5x - Long 2.5x - X-Long 2.5x - X-Long Vascular 3.5x - Regular 3.5x- Long 3.5x - X-Long Veterinary Dentistry 2.5x - Regular 2.5x - Long 2.5x - Long

loupes What Is The Field Of View? The Field of View is the size of the area seen through magnification loupes. Clinicians appreciate a wider field of view because it is easier to adjust when shifting from the naked eye to the loupe and it may reduce eye fatigue. Field width is linked to the magnifying power the higher the power, the smaller the field. Magnification Working Distance Field of View 2.5x 3.0x 3.5x Miltex Part Number Loupe Kit with RED FRAME Miltex Part Number Loupe Kit with BLACK FRAME 10"-13" (S) 3.5" (S) 1-5000 1-5011 12"-16" (R) 3.8" (R) 1-5001 1-5012 14"-18" (L) 4.3" (L) 1-5002 1-5013 16"-20" (XL) 4.6" (XL) 1-5003 1-5014 10"-13" (S) 2.8" (S) 1-5004 1-5015 13"-16" (R) 2.5" (R) 1-5005 1-5016 16"-21" (L) 3.5" (L) 1-5006 1-5017 18"-22" (XL) 4.0" (XL) 1-5007 1-5018 13"-16" (R) 2.3" (R) 1-5008 1-5019 16"-20" (L) 3.0" (L) 1-5009 1-5020 18"-22" (XL) 3.5" (XL) 1-5010 1-5021 Kit Co n t e n t s Head Strap Screwdriver Storage case Cleaning Cl o t h Cleaning Solution Magnification Lo u p e s a n d Fr a m e

www.miltex.com toll-free phone 866-854-8300 toll-free fax 866-854-8400 phone 717-840-9335 fax 717-840-9347 Please call Customer Service today for additional information, an in-office demonstration, to place an order, or to receive other Miltex catalogs. Miltex and Miltex Redefining Excellence are registered trademarks of Miltex, Inc., a subsidiary of Integra LifeSciences Corporation. The Integra wave logo is a trademark of Integra LifeSciences Corporation. Any other trademarks identified in this brochure are the property of their respective owners. Copyright 2009 Integra LifeSciences Corporation 0509/5/A/1 SURG-LOUPE-BROC MPM0282