TESTING & SORTING Automatic Capacitor Testing System Model AE 1000RD Features Designed to perform DC short clearing by applying upto 5000V DC gradually under different stations, followed by measuring the capacitance & tan d value of the core type sprayed capacitor elements and sort them into Good or Retest bins with respect to multiple test results. Element size - length - From 30 to 150mm, Diameter - From 20 to 86mm Automatic feeding of elements through vibrator bowl feeder & motorized conveyor. Adjustable vibrator feed rate with respect to element dimension 20 numbers of stations built for pre DC short clearing, high voltage DC short clearing, capacitance and tan d Value measurement and sorting Standard clamping jaws to handle entire range of capacitors from length 30 to 150mm & diameter from 20 to 86mm Rotary indexing table arranged with clamping jaws is driven by high torque AC motor & drive with inline gearbox. CAM mechanism with sensors for convenient adjustment of indexing time and accurate positioning at each testing stations. 4 terminal kelvin type contacts for accurate measurement of capacitance & tan d value. Precision measuring equipment for capacitance and tan-d measurement ensuring high standard of testing for every test parameter Automatic sorting of elements as Good and Retest. Soft ejection of elements onto the motorized conveyor to maintain quality of elements. Very less power consumption with the incorporation of regenerative charge discharge voltage method for testing of element. Custom built machine with optional usage - Either can be used as stand alone machine or can be used as integrated machine with Automatic core reaming & surface cleaning machine in production line. User friendly colour touch panel along with program memory(100 programs storing facility) and with bin status, graphical representation of capacitance & tan d deviation and test report of last 800 components.
AE 1000 Technical Specification Element Length Element Diameter Element Loading Element Type 30 mm to 150 mm Ø 20 mm to Ø 86 mm Automatic through Vibrator bowl and motorized conveyor. (Only Round type) Sprayed round type and flat type capacitor elements Station 1 Station 2 Element Loading Charging With Clearing Voltage Power Supply Through 5k/500w Resistor. Station 11 Station 12 Station 13 Discharging Through 5K/1000W Resistor Discharging Through 2K/250W Resistors Connected In Parallel Combination Discharging Through 5E/1000W Resistor Station 3 Charging With Clearing Voltage Power Supply Through 5k/500w Resistor. Station 14 Capacitance And Tan D Measurement Through A Four Terminal Kelvin Contact. Station 4 Charging With Operating Voltage Power Supply Through 5k/500w Resistor. Station 15 Station 16 Good C1 Ejection Good C2 Ejection Station 5 Charging With Operating Voltage Power Supply Through Selective Resistor Combination According To Micron. Station 17 Station 18 Good C3 Ejection NG Ejection Station 6 Charging Through Power Supply (Full Voltage Through Power Supply) Station 7 Station 8 No Operation Station 9 Station 10 Self Healing Voltage and Current Station 19 Station 20 Future Expansion Future Expansion 0-5000V DC & Max 200mA Capacitance Range 0.1µF to 1800µF LCR Range LCR Measurement Measurement Frequency Safety Measurement Element Loading Capacitance Meter CR 2012 with basic accuracy of 0.1%, LCD display for measurement results and test conditions with Rs232 communication 4 terminal kelvin arrangement for accurate measurement. 100Hz, 120Hz & 1KHz Safety enclosures to testing area for Operator Safety. Automatic through vibrator bowl & motorized conveyor General Specification Power supply : 415 V AC, 50 Hz, 3 phase, 7.5 KW (Nominal). Air supply : Pressure - 6 Bar, Consumption - 8cfm. Floor space : 2350mm x 1700mm x 1800mm (W x L x H) Machine weight : 1700 Kgs (Approx.). Note: We reserve the right to modify above specifications at any time. Please confirm your specification before ordering.
TESTING & SORTING Automatic Capacitor Testing System Model AE 1000 Features The machine facilitates automatic loading, testing and sorting of the elements. Consists of 14 station specially Built for Pre AC short Clearing, DC Short Clearing, AC high Voltage Test, Capacitance and Tan D Value Measurement and Sorting. Pneumatically operated linear indexing unit ensures wide range of components being handled with minimum change parts. Automatic Feeding of elements from hopper through vibrator conveyor and pick place unit. Automatic sorting of elements into good and reject bins. Operating control panel situated at front side of the machine for easy settings and visualization. All operations are automatically controlled By Programmable Logic Controller (PLC). User friendly touch screen operator controls along with program memory(100 programs storing facility). Precision measuring equipment for Capacitance and Tan-d Measurement ensuring high standard of testing for every test parameter
AE 1000 Technical Specification Element Length Element Diameter 30 mm to 130 mm Ø 18 mm to Ø 60 mm Station 1 Loading / AC short clearing 20V Station 8 Self healing and Measurement at 100% DC Station 2 AC short clearing @ 50V/100V Station 9 Discharge through resistor bank Station 3 Discharge through resistor bank Station 10 Direct Discharge Station 4 0-25% of the set DC volts Station 11 AC high Voltage test 250V to 1200V AC Selectable @ 50V steps Station 5 0-50% of the set DC volts Station 12 Discharge through resistor bank Station 6 0-75% of the set DC volts Station 13 Direct Discharge Station 7 0-100% of the set DC volts Station 14 C & Tan D Measurement through 4 terminal kelvin arrangement up to jigs. Good component ejection & rejection of Bad components Self Healing Voltage and Current AC Voltage 0-2000V DC & Max 100mA 0-1200V AC in steps of 50V /Load Current 10A Max. Under resonance with parallel reactance LCR Range Capacitance Meter CR 2012 with basic accuracy of 0.1%, Test Frequency of 1kHz, LCD display for measurement results and test conditions with Rs232 communication Capacitance Range 2mfd to 100mfd Measurement Frequency Safety Measurement 1KHz Safety enclosures to testing area for Operator Safety. General Specification Power supply : 415 V AC, 50 Hz, 3 phase, 7.5 KW (Nominal). Air supply : Pressure - 6 Bar, Consumption - 8cfm. Floor space : 2350mm x 1700mm x 1800mm (W x L x H) Machine weight : 1700 Kgs (Approx.). Note: We reserve the right to modify above specifications at any time. Please confirm your specification before ordering.
TESTING & SORTING Automatic Capacitor Testing System Model AE1000RN Features Rotary Cam Type Indexing for 8 station testing positioning. Pneumatically open/close, spring loaded clamping contacts & jaws ensures perfect gripping of the capacitors for testing. Quick change over parts in contacts & jaws for the capacitor length range from 30 to 50mm & 50 to 110mm. Automatic control of the operations by programmable Logic Controller with user friendly color Touch Panel. Facility to handle capacitors with dimensional range of length 30mm to 110mm & diameter 20mm to 80mm. Accurate & Reliable measuring equipment used for measurement of Capacitance & Tan D value ensuring high standard of testing. Fast Measurement resulting in high Productivity. The AC high voltage range upto 1000V, 2.15 times the operating voltage can be applied and cleared without any harm to components or equipment. 250V rated components can be applied a voltage of 540V and 440V rated components can be applied with AC voltage of 950V. Pre measuring stations between loading & High Voltage AC for the safety. MCCB along with Power locking for Electrical Safety Automatic ejection of the capacitor on to the collection bin. User friendly colour Touch Panel along with program memory(100 programs storing facility) and with Bin status, graphical representation of Capacitance & Tan D deviation and Test Report of last 800 components. Element Sorting as good and re - test Components.
AE1000RN Technical Specification Capacitor Type Capacitor Dimension Zinc sprayed capacitor elements Length 30mm to 110mm, Diameter 20mm to 80mm Station 1 Automatic Loading Station 5 Discharge through Resistor Station 2 Empty Station 6 Capacitance & tan D measurement Station 3 AC Pre Voltage Test @ 20V AC,30A Station 7 Good Component Ejection Station 4 AC High Voltage test upto 1000V AC Station 8 Re-Test Component ejection. Test Voltage Discharge Contact Pins Component Clamping AC Testing Equipment 1000V AC continuously adjustable through switch & monitored on Digital voltmeter. Rapid Discharge through Resistors within 0.1s. Spring Loaded Pins / 4 terminal Kelvin. Pneumatically open/close spring loaded Brass contact arrangement. Voltage and Current feedback control at AC Power Source. LCR Measuring Equipment Capacitance Meter CR 2012 with basic accuracy of 0.1%, Test Frequency of 1kHz, LCD display for measurement results and test conditions with Rs232 communication Capacitance Range Measurement Frequency Safety Measurement 2mfd to 100mfd 1KHz. Safety enclosures to testing area for Operator Safety. General Specification Power supply Air supply Floor space Machine weight : 415 V AC, 50 Hz, 3 phase, 6 KW (Nominal). : Pressure - 6 Bar, Consumption - 8cfm. : 1800mm x 1220mm x 1970mm (W x L x H). : 800 Kgs (Approx.). Note: We reserve the right to modify above specifications at any time. Please confirm your specification before ordering.
TESTING & SORTING Automatic Clearing, Testing & Sorting System Model DE 1000 (30, 37.5 & 50) Features The machine facilitates automatic loading of elements upto 25 mm diameter and Manual Loading upto 40 mm diameter. Consists of 104 stations specially built for Initial AC Short Clearing, DC Short Clearing, DC Test, AC High Voltage Test, Discharge through resistor, Direct Short, Capacitance Value and Tan D measurement, Sorting into 4 bins. Motorized Chain indexing unit ensures wide range of components being handled with minimum change parts. Automatic Feeding of elements from vibrator conveyor and element placing unit. Designed to test the capacitor elements of three different values simultaneously and continuously along with sorting into Good Cap-1, Good Cap-2, Good Cap-3 and Retest to the respected bins. Operating control panel with Capacitance & Tan D measuring instrument, digital Panel meters for AC High/ Low voltage are situated at front side convenient position from ground level for easy settings and visualization. All operations are automatically controlled By Programmable Logic Controller (PLC). User friendly touch screen operator controls along with program memory(100 programs storing facility). Precision measuring equipment for Capacitance and Tan D Measurement ensuring high standard of testing for every test parameter
DE 1000 Technical Specification Element Length Element Diameter Element Loading 30 mm 37.5 mm Ø 16 mm to Ø 25 mm (Automatic Loading) & Above Ø 25 mm to Ø 40 mm (Manual Loading) Automatic / Manual 50 mm AC short clearing @ 20V AC, 10A Max. AC High Voltage Test upto 1000V AC @ 10A Max. AC short clearing @ 50V/100V, 5a Max. Discharge through resistor bank DC Short Clearing from 600V to 1600V Direct Discharge DC Pass / Fail Cap & Tan D Measurement Discharge Through resistors Capacitor Ejection in to 3 Good Bins. Direct Discharge Retest Ejection Self Healing Voltage and Current AC Voltage Capacitance Range Total No. Of Capacitor clamping Jigs Binning 600-1000V DC & Max 100mA 0-1000V AC @ 20 mfd / Load Current 10A Max. 2mfd to 20mfd 104 jigs. 3 Good Bins and 1 Retest bin. LCR Measuring Equipment Measurement Frequency Capacitance Meter CR 2012 with basic accuracy of 0.1%, Test Frequency of 1kHz, LCD display for measurement results and test conditions with Rs232 communication 1KHz General Specification Power supply : 230 V AC ± 10%, 50 Hz, 1 phase, 3 KW (Nominal). Air supply Floor space Machine weight : Pressure - 6 Bar, Consumption - 5cfm. : 2570mm x 1950mm x 1600mm (W x L x H). : 1500 Kgs (Approx.). Note: We reserve the right to modify above specifications at any time. Please confirm your specification before ordering.
TESTING & SORTING Clearing, Testing & Sorting System Model DE 1000 (50 & 75) Features The machine facilitates manual loading of elements upto 80 mm diameter. Consists of 52 stations specially built for Initial AC Short Clearing, DC Short Clearing, DC Test, Discharge through resistor, Direct Short, Capacitance Value and Tan D measurement, Sorting into 2 bins. Motorized Chain indexing unit ensures wide range of components being handled with minimum change parts. Automatic Feeding of elements from vibrator conveyor and element placing unit. Automatic sorting of elements into 2 bins (Good Cap & Reject). Operating control panel with Capacitance & Tan D measuring instrument, digital Panel meters for AC High/ Low voltage are situated at front side convenient position from ground level for easy settings and visualization. All operations are automatically controlled By Programmable Logic Controller (PLC). User friendly touch screen operator controls along with program memory(100 programs storing facility). Precision measuring equipment for Capacitance and Tand Measurement ensuring high standard of testing for every test parameter
DE 1000 Technical Specification Element Length Element Diameter Element Loading 50 mm Ø 20 mm to Ø 80 mm Manual 75 mm Manual AC short clearing @ 20V AC, 10A Max. 1000V AC continuously adjustable through switch & monitored on Digital voltmeter AC short clearing @ 50V/100V, 5a Max. Discharge through resistor bank DC Short Clearing from 600V to 1600V Direct Discharge DC Pass / Fail Cap & Tan D Measurement Discharge Through resistors Capacitor Ejection in to 2 Separate Good/Reject Bins. Direct Discharge Retest Ejection Self Healing Voltage and Current 600-1000V DC & Max 100mA Capacitance Range Total No. Of Capacitor clamping Jigs 10 mfd to 100mfd 52 jigs. Binning 1 Good Bin and 1 Retest bin. LCR Measuring Equipment Capacitance Meter CR 2012 with basic accuracy of 0.1%, Test Frequency of 1kHz, LCD display for measurement results and test conditions with Rs232 communication Measurement Frequency 1KHz General Specification Power supply : 230 V AC ± 10%, 50 Hz, 1 phase, 3 kw (Nominal). Air supply : Pressure - 6 Bar, Consumption - 5cfm. Floor space : 2570mm x 1900mm x 1600mm (W x L x H) Machine weight : 1500 Kg (Approx.). Note: We reserve the right to modify above specifications at any time. Please confirm your specification before ordering.