O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS

Similar documents
INSTRUCTION MANUAL. March 11, 2003, Revision 3

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Model 7000 Low Noise Differential Preamplifier

V50D ELECTRIC GUITAR AMPLIFIER WITH DIGITAL DELAY AND CHORUS. User s Manual

INTRODUCTION. Please read this manual carefully for a through explanation of the THETA Head and its functions. PRECAUTIONS

SELECTIVE CALL INTERCOM SYSTEM MODEL: IM-5000 MASTER STATION

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Installation & Operation Manual

FLEXRISE2 VERSION. 2 LEG / 2 MOTOR ELECTRIC TABLE BASE (36 to 72 ) **PATENT PENDING**

TOA 500 SERIES MIXER POWER AMPLIFIER

TS-700/1000 INVERTER Instruction Manual

INTRODUCTION. Please read this manual carefully for a through explanation of the THETA Pre-Amplifier and its functions.

SMART TOILET CONTROL

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

BC145 SIGNAL ISOLATOR BOARD

This section is specifically about safety matters

GUITAR POWER AMPLIFIER U S E R ' S M A N U A L

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

Active UTP Transceiver Hub Installation Guide

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

Wilcoxon Research PA8HF power amplifier Operating guide

V160R ELECTRIC GUITAR AMPLIFIER WITH A TUBE PREAMP, REVERB AND BUILT-IN CHROMATIC TUNER. User s Manual

PA8HF power amplifier Operating guide

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

2011 / Circuit Tracer

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

Big Bang. B B O w n e r s M a n u a l. Power Amplifiers. SpeakerCraft BB2125 POWER ACTIVE PROTECTION L

RMD3000 DPO3000 Series Rackmount Kit

RMD2000 DPO2000 and MSO2000 Series Rackmount Kit Instructions

AD-8100 & AD-8200 Servo Amplifiers

QL55 Series Luminescence Sensor

Allegro Home Office Assembly Instructions. Tipping Restraint. Bun Foot W/ Leveler. 4 pcs.

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

SMART TOILET CONTROL

RMD5000 Rackmount Kit Instructions

INSTRUCTIONS PS2500 POWER SUPPLY

HTA125A/250A. Power Amplifiers. Installation & Use Manual

MODEL AT-10 ANALOG TRANSMITTER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Features COMPACT HIGH POWER MONO SUBWOOFER AMPLIFIER. Quick Start Guide

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA

AMP-12 OPERATOR S MANUAL

WELCOME TO ZUMA R300 ULTRA-LOW NOISE WORLD TOUR READY

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

SYSTEM OPERATING CONTROLS

User s Manual Current Probe. IM E 2nd Edition IM E

Conic Systems Inc. INSTRUCTION MANUAL FOR DATATRAN C2547 UNIVERSAL AMPLIFIER MODULE

User s Manual Current Probe IM E. 6th Edition

TABLE OF CONTENTS WARRANTY

DA216S DISTRIBUTION AMPLIFIER

RM4000 Tektronix 4000 Series Rackmount Kit

On-Line Cardio Theater Wireless Digital Transmitter Installation and Instruction Manual

f i r e - p a r t s. c o m

DCM w Power Amplifier

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS

PART #MSP-DCCPPWS Plasma Wall Swing-Out (PWS) Wall Mount

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

RM4000 DPO4000 Series Rackmount Kit

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Amplifier Series BASIC. Installation & Operations Manual

30XR-A Professional Digital Multimeter Users Manual

Important Safety Information

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

CANARY AUDIO. EL34 Stereo Power Amplifier. Handcrafted in California CA-770 OWNER S MANUAL MADE IN USA

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

Isolated Variable AC Line Supply Instruction Manual

QL50 Luminescence Sensor

This section is specifically about safety matters

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

MODEL W Power Amplifier

WMA 4300 Professional Series Installation Power Amplifer Owner s Manual

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

KeyPre KP6 - Electronic Instrument Preamplifier

2015 RIGOL TECHNOLOGIES, INC.

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

XIA3145 INSTALLATION/OWNER S MANUAL 2/1-Channel Mobile Power Amplifier

OPERATOR'S MANUAL ROUTER MOUNTING KIT

R50C Electric Guitar Amplifier (with AGX Technology)

INTELLIMETER REGISTER

MODEL KBWD-15 Pulse Width Modulated (PWM)

R PROFLAME Instruction Book Collection

Video Data Power. HubWayEXP. UL Listed Sxteen (16) Channel UTP Power Injector. Installation Guide Z1409. More than just power. TM. Rev.

INSTRUCTION MANUAL LKG

DAZZLE ACCENT LIGHTING SYSTEM

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Installation & User Guide. For Powering Distributed Audio Systems A45-X2 TWO CHANNEL AMPLIFIER

USER S MANUAL. 580 TV Line OSD Bullet Camera With 2 External Illuminators

USER'S MANUAL DMR-4350

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808

ABM International, Inc. Navigator Assembly Manual

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

QRS14 User s Guide. MEMS GYROSCOPE Model QRS14. Systron Donner Inertial Sales and Customer Service. Phone: Fax:

DD1-1300S. 500 Watts RMS Watts RMS Watts RMS- 1. Mono-Bloc Digital Power Amplifier

AC-TX Volt/100 Volt Transformer Panel for VR61 and VR62 Loudspeakers and the CLA37 Column Loudspeaker AC-TX128

Broadband Step-Up Transformer. User Manual

INSTALLATION GUIDE PREMIUM FRONT BUMPER. AEV30103AE Last Updated: 09/08/14 US PATENTS: D683281, D CHINESE PATENT: ZL

REGATTA PATH LIGHT (RGP)

Transcription:

O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS PAGE 1-3 OPERATING INSTRUCTIONS 4 DEMAG CYCLE STEPS 5 INSTALLATION INSTRUCTIONS 6 SPECIFICATIONS 7 & 8 DIMENSIONAL DIAGRAMS 9 SPARE PARTS LIST 10 RETURN AND REPAIR INSTRUCTIONS THIS MANUAL USES TWO SYMBOLS TO ATTRACT YOUR ATTENTION TO IMPORTANT INFORMATION: SAFETY WARNING Failure to heed a safety warning can result in injury to yourself or others. The purpose of the safety symbol is to attract your attention to possible hazards. The symbol and the explanation with it deserve your full attention and understanding. A safety warning alone does not eliminate a hazard, and the instruction or warning it gives is not a substitute for proper accident prevention measures. NOTE: This symbol highlights information useful to the proper operation of equipment. DD-9912 REV. G 12/28/99 O.S. WALKER Rockdale Street, Worcester, MA 01606 (508)-853-3232 FAX (508)-852-8649 3508 Glenridge Drive, Chino Hills, CA 91709 (909)-597-4785 FAX (909)-597-0581 901 Arvin Avenue, Stoney Creek, Ontario, L8E5N9 Canada (905)-643-3338 In Canada: 1-800-267-4678 FAX (905)-643-6111, In Europe: 31-497-383835 www.walkermagnet.com Email: info@walkermagnet.com

The O. S. Walker Microprocessor Chuck Control, Model MSB, has four functions: Full Holding; Variable Holding; Residual Holding; and Release. Each function has its own pushbutton switch and light. The controller comes equipped with 115 volt line cord and chuck cord attachments, a potentiometer that adjusts the Variable current from 0-100%, and adjustments for the length and number of pulses per Release cycle. Model MSB1 will power any chuck that requires 150 watts or less; MSB3 will power any chuck that requires 300 watts or less; MSB5 will power any chuck that requires 500 watts or less. When power is first applied to the control, or if AC power is interrupted while the control is running, the control returns to the mode of operation selected just prior to loss of power. This allows easy resumption of machining after an AC line dropout. See Page 7 for a diagram of the control panel. FULL HOLDING In the Full Holding position, full voltage is supplied from the control as soon as the operator selects this function on the front panel. The indicator light for the Full holding function is illuminated when the selection is made. NOTE: : Full holding has equivalent holding force to 100% on the Variable holding control knob. VARIABLE HOLDING When the operator presses the Variable holding button, the output voltage of the control can be adjusted from zero to full with the Variable control knob. When switching from Variable holding to Release, the number of release pulses decreases proportionately. A varying amount of Residual hold can be achieved by turning the Variable control knob to zero from its previous holding position without pressing the Residual button. RESIDUAL HOLDING The output of the control is reduced to zero when the operator puts the control in the Residual position. The chuck control turns the magnet fully ON for a short period of time, thus leaving recognizable residual holding power in the chuck; this is called True Residual. During this brief pulse, the indicator light will be OFF, but otherwise will be ON until the operator selects another function. O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 1

RELEASE Selecting the Release function initiates an automatic demagnetization cycle. During the demagnetization cycle, the output voltage produced by the control is reduced from full to zero in a pre-determined number of decreasing pulses (see page 4). The polarity of these pulses alternately reverses from negative to positive as the magnitude of the voltage decreases. The Walker Microprocessor Chuck Control can generate a maximum of 16 pulses per Release cycle, but is set at the factory for eight. The Release light will flash on and off to indicate that demagnetization is taking place, and will remain OFF when the cycle is complete. Because it takes almost as long for the magnetic field of a chuck to decay as it does to build up, the control delivers output voltage to the chuck for only a percentage of the duration of a pulse. The duration or period of each pulse is controlled by a potentiometer that is accessible without disassembling the unit, and can be adjusted by the operator with a small, straight blade, insulated screwdriver. Clockwise adjustment of this potentiometer,vr2, which is located next to the AC input cord (see Page 7), will result in more complete release of larger workpieces. Counter-clockwise adjustment will decrease the cycle time and will allow for the most efficient use of the magnetic chuck. The time between pulses is automatically adjusted by the control for the optimum Release cycle time (patent pending). O. S. Walker's Model MSB also has an internal adjustment for the number of pulses per Release cycle. This adjustment is provided so that the operator can determine the right amount of pulses it takes to get the fastest, most complete release of a part (in general, magnetically soft parts can be released with 3 to 5 pulses, while magnetically hard parts may require 6 to 12 pulses for a complete release). SAFETY WARNING: THIS ADJUSTMENT MUST BE MADE BY QUALIFIED SERVICE PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK, WHILE THE CONTROL IS OPEN THE OPERATOR SHOULD NEVER TOUCH ANY PART OF THE CIRCUITRY OTHER THAN THE POTENTIOMETER. To adjust the number of steps per Release cycle, first remove the four screws (size 8-32) from the bottom of the unit and pull the unit halfway apart, which exposes potentiometer VR1 on the left side of the control. Turn VR1 clockwise with a small, straight blade insulated screwdriver to increase the number of pulses, counter-clockwise to decrease the number of pulses. When the adjustment has been made to the operator's satisfaction, push the unit together and replace the four screws. O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 2

Electronic Protective Circuits: If the Chuck Control is overloaded by a short circuit or a chuck too large for this control's rating, the control will sense this condition and will attempt to protect itself. The DC output power will be turned off, all indicator lights will flash on and off, and the control will not respond to any function selection. This will continue until AC power is removed from the control and the problem is corrected. If the control is switched into sudden high power operation with too large a load, the AC fuse may blow before the electronic protective circuits can function. GROUNDING AND SHIELDING The base of the chuck is to be grounded through the ground wire of the DC chuck cable. All electrical chassis' must be safety grounded. On all units operating from 115VAC power, it is also assumed that one side of the 115V AC line will be connected to the safety ground at the AC source. This is normally done in the wiring of the building. If the 115VAC is provided through an isolation transformer in the machining equipment, then one side of this 115VAC should be tied to safety ground in the equipment. If not, the control may be subject to interference from electrical noise on the floating AC input. Grounding either side is satisfactory. The chuck control's DC power output leads may be routed with other 115V level power leads in the machine. They must not be routed in the same wire bundle with 400V or other high voltage leads. O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 3

T = ON TIME ADJ. 0.1 to 2 SECONDS t = OFF TIME ADJ. AUTOMATICALLY START OF DEMAG. CYCLE (RELEASE INDICATOR BEGINS FLASHING) T t END OF DEMAG CYCLE (RELEASE INDICATOR STAYS OFF) NOTE: FIRST PULSE IS ALWAYS NEGATIVE TOTAL DEMAG TIME NUMBER OF PULSES IS ADJUSTABLE FROM 1 16 DEMAG CYCLE STEPS MAX POS DC OUTPUT VOLTAGE TO CHUCK 0V NEG MAX 10% MAX O..S. WALKER MICROPROCESSOR CHUCK CONTROL Page 4

See Page 7 for a dimensional diagram of the control. 1. Remove the two 8-32 screws that hold the wall bracket to the control. 2. Mount the wall bracket to a vertical surface using the set of mounting holes. 3. Slide the control onto the wall bracket and fasten using the two 8-32 screws. 4. Connect the chuck cord to the chuck with the twist lock connector. 5. Connect the power cord to the 115V AC outlet. SAFETY WARNING: NEVER DISCONNECT THE CHUCK WHILE POWER IS APPLIED TO THE UNIT, SINCE SHOCK FROM INDUCTIVE VOLTAGE MAY OCCUR. NOTE: MSB Controls are not designed for use with a Remote Interface. O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 5

SPECIFICATIONS - MSB SERIES Input Voltage: 115V AC Nom. (100-130V AC) 50/60Hz (MSB1-200VA MSB3-400VA MSB5-600VA) Output Voltage: 115V DC MSB1-150W MSB3-300W MSB5-500W Ambient Temperature: 120 degrees Fahrenheit, maximum Size: MSB 1 & 3-7.25" W x 7.25" D x 10" H MSB 5-7.25" W x 9.25" D x 10" H Weight: MSB1-11 lbs. MSB 3-13 lbs. MSB 5-16 lbs. Mounting Holes:.31" dia.; 5.5" vertical spacing (2 holes) Release Cycle: Number of Release Steps: 1-16, factory set to 8. Release Pulse Time: 0.1-2 seconds, factory set to 1 sec. Time between pulses ("OFF" Time): Auto. adjusted MSB1 PART NUMBER: DXM-9459 MSB3 PART NUMBER: DXM-9460 MSB5 PART NUMBER: DXM-9455, DXM-9461, DXM-9525 O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 6

O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 7

5.00 5.50 8.40.22 DIA. (2) HOLES.31 DIA. HOLES FIGURE 2 STANDARD MOUNTING BRACKET FOR MSB SERIES CHUCK CONTROLS O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 8

SPARE PARTS LIST DECRIPTION MSB-1 MSB-3 MSB-5 Control PC Board 39-DD14401 39-DD14328 39-DD14328 Fuse 18-1124 18-1219 18-1219 Transformer (T2) ---------- 12-0267 12-0267 Ribbon Cable 10-5418 10-5418 10-5429 Switch Panel Membrane 56-DD14591 56-DD14591 56-DD14591 Assembly O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 9

RETURN AND REPAIR INSTRUCTIONS For warranty and non-warranty repairs on any part of your chuck system, contact O.S. Walker Company TOLL FREE at 1-800-W-MAGNET. A return authorization number will be issued along with any applicable packaging and shipping instructions. After receipt of the components to be repaired, O.S. Walker Company will perform an inspection and provide an estimate of the repairs costs at no charge to the customer. Authorization from the customer must be obtained by O.S.Walker Company before repairs are made. Transportation charges, both to and from the factory, are the sole responsibility of the customer. O. S. WALKER MICROPROCESSOR CHUCK CONTROL Page 10