NS..S contactor relays - with spring terminals AC operated

Similar documents
TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Characteristics 5 TeSys k contactors and reversing contactors

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Type CP-S, CP-C & CP-A Switch mode

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Motor starters. TeSys E. Designed for the essential

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Three-phase monitoring relays CM-PFE and CM-PFE.2

CP-T range Benefits and advantages

Three-phase monitoring relay CM-PFS

3 - Protection components Circuit-breakers

Description Basic devices with positive operation contacts

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

CP-E range Benefits and advantages

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Three-phase monitoring relays CM-PVS.81

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

Type: DILEM 10 G(24VDC) Article No.:

Three-phase monitoring relays

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Output of three-phase motors at 50 Hz and 400 V

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Three-phase monitoring relay

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Contactors and Contactor Assemblies

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Electronic timer CT-SDS.22

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Control module CP-A CM

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

Electronic timer CT-SDD.22

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

CP-T range Product group picture

Interface relays and optocouplers Product group picture

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

48 Series - Relay interface modules A. Features

Page 13-2 Page Page 13-7

Type: DILM40(RDC24) Article No.:

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-SDE

Three-phase monitoring relay CM-PVE

Controls Contactors and Contactor Assemblies Special Applications

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Subject to changes 11/2003 Page 1/7

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

38 Series - Relay interface modules A. Features /

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Transcription:

NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed with: spring terminals 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol) control circuit: AC operated add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories. Ordering details Number of contacts Rated control circuit Type Order code Weight 1st stack 2nd stack voltage Uc (1) Pkg (1 pce) V 50 Hz V 60 Hz kg NSES0 1SBH101004R20 0.0 31-120 NSES6 1SBH101004R12 0.0 0 0 NSES6 1SBH101004R 0.0 32 400 400 NSES8 1SBH101004R 0.0 Note: for multiple packaging, please contact your ABB local sales organization. (1) Other control voltages see voltage code table. NS31ES0 1SBH101004R2031 0.0-120 NS31ES6 1SBH101004R11 0.0 0 0 NS31ES6 1SBH101004R21 0.0 400 400 NS31ES8 1SBH101004R 0.0 NS40ES0 1SBH101004R2040 0.0-120 NS40ES6 1SBH101004R10 0.0 0 0 NS40ES6 1SBH101004R20 0.0 400 400 NS40ES8 1SBH101004R20 0.0 NSES0 1SBH101004R20 0.260-120 NSES6 1SBH101004R16 0.260 0 0 NSES6 1SBH101004R26 0.260 400 400 NSES8 1SBH101004R28 0.260 NSES0 1SBH101004R20 0.260-120 NSES6 1SBH101004R16 0.260 0 0 NSES6 1SBH101004R26 0.260 400 400 NSES8 1SBH101004R28 0.260 NSES0 1SBH101004R20 0.260-120 NSES6 1SBH101004R16 0.260 0 0 NSES6 1SBH101004R26 0.260 400 400 NSES8 1SBH101004R28 0.260 NSES0 1SBH101004R20 0.260-120 NSES6 1SBH101004R16 0.260 0 0 NSES6 1SBH101004R26 0.260 400 400 NSES8 1SBH101004R28 0.260 NS80ES0 1SBH101004R2080 0.260-120 NS80ES6 1SBH101004R1680 0.260 0 0 NS80ES6 1SBH101004R2680 0.260 400 400 NS80ES8 1SBH101004R2880 0.260 Main dimensions mm, inches.5 2.85".5 2.85" 35 mm EN/IEC 605 NSES, NS31ES, NS40ES 35 mm EN/IEC 605 NSES, NSES, NSES, NSES, NS80ES 1SBC10S0201 20 ABB Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com

NSL..S contactor relays - with spring terminals DC operated NSLES 1SBC1010F00 Description NSL..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed with: spring terminals 4 poles or 8 poles. Contactor relays have mechanically linked auxiliary contact elements (side-marked symbol) control circuit: low coil consumption (3 W at pull-in and holding) DC operated with solid core magnet. Suitable for direct control by PLC outputs (the polarity on the coil terminals and - must be respected) add-on auxiliary contact blocks for front mounting and a comprehensive range of accessories. Ordering details Number of contacts Rated control circuit Type Order code Weight 1st stack 2nd stack voltage Uc (1) Pkg (1 pce) V DC kg NSLES- 1SBH103004R 0.280 31 48 NSLES- 1SBH103004R 0.280-110 NSLES-86 1SBH103004R 0.280 32 0 NSLES-88 1SBH103004R82 0.280 - - - - - - - Note: for multiple packaging, please contact your ABB local sales organization. (1) Other control voltages see voltage code table. NSL31ES- 1SBH103004R 0.280 48 NSL31ES- 1SBH103004R 0.280 110 NSL31ES-86 1SBH103004R81 0.280 0 NSL31ES-88 1SBH103004R 0.280 NSL40ES- 1SBH103004R80 0.280 48 NSL40ES- 1SBH103004R80 0.280 110 NSL40ES-86 1SBH103004R80 0.280 0 NSL40ES-88 1SBH103004R80 0.280 NSLES- 1SBH103004R 0.320 48 NSLES- 1SBH103004R 0.320 110 NSLES-86 1SBH103004R86 0.320 0 NSLES-88 1SBH103004R88 0.320 NSLES- 1SBH103004R 0.320 48 NSLES- 1SBH103004R 0.320 110 NSLES-86 1SBH103004R86 0.320 0 NSLES-88 1SBH103004R88 0.320 NSLES- 1SBH103004R 0.320 48 NSLES- 1SBH103004R 0.320 110 NSLES-86 1SBH103004R86 0.320 0 NSLES-88 1SBH103004R88 0.320 NSLES- 1SBH103004R 0.320 48 NSLES- 1SBH103004R 0.320 110 NSLES-86 1SBH103004R86 0.320 0 NSLES-88 1SBH103004R88 0.320 NSL80ES- 1SBH103004R80 0.320 48 NSL80ES- 1SBH103004R80 0.320 110 NSL80ES-86 1SBH103004R8680 0.320 0 NSL80ES-88 1SBH103004R8880 0.320 Main dimensions mm, inches.5 2.85".5 2.85" 35 mm EN/IEC 605 NSLES, NSL31ES, NSL40ES 35 mm EN/IEC 605 NSLES, NSLES, NSLES, NSLES, NSL80ES 1SBC10S0201 Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com ABB

NS..S and NSL..S contactor relays - with spring terminals Main accessories Contactor relays and main accessories 4-pole contactor relay RV5, RC1 or RT5 8-pole contactor relay NS..S NSL..S Contactor relays CA3..S RV5, RC1 or RT5 NS..S NSL..S Contactor relays Main accessory fitting details Contactor types Main poles Front-mounted accessories Auxiliary contact blocks Side-mounted accessories 1-pole CA3..S Surge suppressors NS..S 2 2 E 2 max. + RV5 or RC1 NS..S 3 1 E NS..S 4 0 E NS..S 4 4 E RV5 or RC1 NS..S 5 3 E NS..S 6 2 E NS..S 7 1 E NS..S 8 0 E NSL..S 2 2 E 2 max. + RV5 or RT5 NSL..S 3 1 E NSL..S 4 0 E NSL..S 4 4 E RV5 or RT5 NSL..S 5 3 E NSL..S 6 2 E NSL..S 7 1 E NSL..S 8 0 E Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com

NS..S and NSL..S contactor relays - with spring terminals Main accessories CA30S 1SBC101037F00 Front mounted instantaneous auxiliary contact blocks For contactor relays Auxiliary contacts Type Order code Pkg qty Weight (1 pce) kg NS..S, NSL..S 1 0 CA30S 1SBN011019T1010 10 0.011 0 1 CA3-01S 1SBN011019T1001 10 0.011 RV5 1SBC5001F0301 Surge suppressors For contactor relays NS..S, NSL..S Rated control circuit voltage - Uc Type Order code Pkg qty Weight (1 pce) V AC DC kg...50 RV5/50 1SBN050010R1000 2 0.015 50...3 RV5/3 1SBN050010R1001 2 0.015 110...250 RV5/250 1SBN050010R1002 2 0.015 250...0 RV5/0 1SBN050010R1003 2 0.015 NS..S...50 RC1/50 1SBN050100R1000 2 0.012 50...3 RC1/3 1SBN050100R1001 2 0.012 110...250 RC1/250 1SBN050100R1002 2 0.012 250...0 RC1/0 1SBN050100R1003 2 0.012 NSL..S 12...32 RT5/32 1SBN050020R1000 2 0.015 25...65 RT5/65 1SBN050020R1001 2 0.015 50...90 RT5/90 1SBN050020R1002 2 0.015 77...150 RT5/150 1SBN050020R1003 2 0.015 150...2 RT5/2 1SBN050020R1004 2 0.015 1SBC1015S0201 Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com ABB

NS..S and NSL..S contactor relays - with spring terminals Technical data Contact utilization characteristics according to IEC DC operated NSL..S Standards IEC 60947 and EN 60947 Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional free-air thermal current Ith θ 40 C 10 A Ie / Rated operational current AC5 acc. to IEC 60947 27 V 50/60 Hz 6 A 0-0 V 50/60 Hz 4 A 400-0 V 50/60 Hz 3 A 500 V 50/60 Hz 2 A 690 V 50/60 Hz 2 A Making capacity AC5 10 x Ie AC5 acc. to IEC 60947 Breaking capacity AC5 10 x Ie AC5 acc. to IEC 60947 Ie / Rated operational current DC- acc. to IEC 60947 V DC 6 A / 4 W 48 V DC 2.8 A / 4 W V DC 1 A / W 110 V DC 0.55 A / 60 W 125 V DC 0.55 A / 69 W 0 V DC 0.27 A / 60 W 250 V DC 0.27 A / 68 W Short-circuit protection device for contactors Ue 500 V AC - gg type fuse 10 A Rated short-time withstand current Icw for 1.0 s 100 A at 40 C ambient temperature,in free air from a cold state for 0.1 s 0 A Minimum switching capacity 12 V / 3 ma with failure rate acc. to IEC 60947-5 10-7 Non-overlapping time between N.O. and N.C. contacts 1.5 ms Power dissipation per pole at 6 A 0.1 W Max. electrical switching frequency AC5 1200 cycles/h DC- 900 cycles/h Mechanically linked contacts Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts (CA3..S aux. acc. to annex L of IEC 60947 contact blocks) are mechanically linked contacts. Contact utilization characteristics according to UL / CSA DC operated NSL..S Standards UL 508, CSA C.2 N Max. operational voltage 600 V AC, 250 V DC Pilot duty A600, Q300 AC thermal rated current 10 A AC maximum volt-ampere making 00 VA AC maximum volt-ampere breaking 0 VA DC thermal rated current 2.5 A DC maximum volt-ampere making-breaking 69 VA 1SBC101503S0201 ABB Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com

NS..S and NSL..S contactor relays - with spring terminals Technical data Magnet system characteristics for NS..S contactor relays Coil operating limits AC supply acc. to IEC 60947 0.85...1.1 x Uc (at θ 60 C); Uc (at θ 70 C) AC control voltage Rated control circuit voltage Uc at 50 Hz...415 V at 60 Hz...415 V Coil consumption Average pull-in value 50 Hz VA 60 Hz VA 50/60 Hz VA Average holding value 50 Hz 6.5 VA / 1.5 W 60 Hz 5 VA / 1.2 W 50/60 Hz 6.5 VA / 1.5 W Drop-out voltage Approx. 30...50 % of Uc Operating time Between coil energization and: N.O. contact closing 9... ms N.C. contact opening 6...18 ms Between coil de-energization and: N.O. contact opening (1) 5...19 ms N.C. contact closing (1) 7... ms (1) The use of RC1 surge suppressor increases opening time by a factor of 2 to 3. Magnet system characteristics for NSL..S contactor relays Contactor relay types DC operated NSL..S Coil operating limits DC supply acc. to IEC 60947 0.85...1.1 x Uc (at θ 60 C); Uc (at θ 70 C) DC control voltage Rated control circuit voltage Uc 12...0 V DC Coil consumption Average pull-in value 3 W Average holding value 3 W Drop-out voltage Approx. 10...40 % of Uc Coil time constant Open L/R 12 ms Closed L/R 40 ms Operating time Between coil energization and: N.O. contact closing 36...59 ms N.C. contact opening 31... ms Between coil de-energization and: N.O. contact opening (1)...17 ms N.C. contact closing (1) 15...20 ms (1) The use of RT5 surge suppressor increases opening time by a factor of 1.1 to 1.2. Mounting characteristics and conditions for use DC operated NSL..S Mounting positions Pos. 2 Pos. 4 Pos. 3 Pos. 1 Pos. 5 Mounting distances The contactor relays can be assembled side by side. Fixing On rail according to IEC 605, EN 605 35 x 7.5 mm or 35 x 15 mm By screws (not supplied) 2 x M4 screws placed diagonally 1SBC101503S0201 Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com ABB 25

NS..S and NSL..S contactor relays - with spring terminals Technical data General technical data DC operated NSL..S Rated insulation voltage Ui acc. to IEC 60947 690 V acc. to UL / CSA 600 V Rated impulse withstand voltage Uimp. 6 kv Ambient air temperature close to contactor relay Operation in free air 0...+70 C Storage -60...+80 C Climatic withstand Category B according to IEC 60947 Annex Q Maximum operating altitude (without derating) 3000 m Mechanical durability Number of operating cycles 20 millions operating cycles Max. switching frequency 3600 cycles/h Shock withstand 1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position acc. to IEC 600687 and EN 600687 Shock direction Mounting position 1 NS contactor relays - AC operated NSL contactor relays - DC operated C1 A 20 g 20 g closed position / 10 g open position B1 5 g 15 g closed position / 5 g open position A A B1 B2 B2 15 g 10 g C1 19 g closed position / 8 g open position 19 g closed position / 8 g open position C2 C2 16 g closed position / g open position g closed position / 8 g open position Vibration withstand 5...300 Hz acc. to IEC 60068-6 3 g closed position / 2 g open position Connecting characteristics DC operated NSL..S Main terminals Spring terminals Connection capacity (min.... max.) Pole and coil terminals Rigid solid 1 x 0.75...2.5 mm² 2 x 0.75...2.5 mm² Flexible with non insulated ferrule 1 x 0.75...2.5 mm² 2 x 0.75...2.5 mm² Flexible with insulated ferrule 1 x 0.75...1.5 mm² 2 x 0.75...1.5 mm² Connection capacity acc. to UL / CSA 1 or 2 x AWG 18... Stripping length 10 mm Degree of protection acc. to IEC 60947 / EN 60947 and IEC 609 / EN 609 All terminals IP20 Screwdriver type Flat Ø 3.5 1SBC101503S0201 26 ABB Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com

NS..S contactor relays - with spring terminals Terminal marking and positioning NS..S contactor relays - AC operated Standard devices without addition of auxiliary contact blocks 31 31 NSES 32 NS31ES 32 NSES NS31ES NS40ES NSES NS40ES NSES NSES NSES NSES NSES NSES NS80ES NSES NS80ES Other possible contact combinations with auxiliary contact blocks added by the user = + 6- = + + Combination 41E 6- Combination 41E = NS31ES + CA30S Combination 42E = NS40ES + CA3-01S + CA3-01S Combination 42E = + 6- = + + Combination 50E 6- Combination 50E = NS40ES + CA30S Combination 60E = NS40ES + CA30S + CA30S Combination 60E CA3..S 1-pole auxiliary contact blocks CA30S CA3-01S Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com

NSL..S contactor relays - with spring terminals Terminal marking and positioning NSL..S contactor relays - DC operated (the polarity, - must be respected) Standard devices without addition of auxiliary contact blocks 31 31 - NSLES 32 - NSL31ES 32 - - - - - - NSLES NSL31ES NSL40ES NSLES NSL40ES NSLES NSLES - - NSLES - - - - - - NSLES NSLES NSLES NSL80ES NSLES NSL80ES Other possible contact combinations with auxiliary contact blocks added by the user - = + 6- = + + Combination 41E 6- - - - - - Combination 41E = NSL31ES + CA30S Combination 42E = NS4L0ES + CA3-01S + CA3-01S Combination 42E = + 6- = + + - Combination 50E 6- - - - - - Combination 50E = NSL40ES + CA30S Combination 60E = NSL40ES + CA30S + CA30S Combination 60E CA3..S 1-pole auxiliary contact blocks CA30S CA3-01S Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com

NS..S contactor relays - with spring terminals Main dimensions mm, inches 4-pole contactor relays.5 2.85" 2 x M4 U 35 1.38" ø 4.2 0.17".5 2.85" 1SBC1017S0201 35 mm EN/IEC 605 60 2.36" 50 1.97" NSES, NS31ES, NS40ES.5 2.85" 35 mm EN/IEC 605 NSES, NS31ES, NS40ES + CA3..S front-mounted 1-pole auxiliary contact block 8-pole contactor relays 35 mm EN/IEC 605 NSES, NSES, NSES, NSES, NS80ES 30 ABB Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com

NSL..S contactor relays - with spring terminals Main dimensions mm, inches 4-pole contactor relays.5 2.85" 2 x M4 U 35 1.38" ø 4.2 0.17".5 2.85" 1SBC1017S0201 35 mm EN/IEC 605 60 2.36" NSLES, NSL31ES, NSL40ES.5 2.85" 35 mm EN/IEC 605 NSLES, NSL31ES, NSL40ES + CA3..S front-mounted 1-pole auxiliary contact block 8-pole contactor relays 35 mm EN/IEC 605 NSLES, NSLES, NSLES, NSLES, NSL80ES Phone: 800.894.0412 - Fax: 888.7.47 - Web: www.clrwtr.com - Email: info@clrwtr.com ABB 31