SC-FI Series Frequency to Current Signal Conditioner

Similar documents
INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

K-FACTOR SCALER B & B

MODEL AT-10 ANALOG TRANSMITTER

INSTALLATION & OPERATION MANUAL

RM3-IV-LPI. 4-20mA Loop Powered Signal Isolators ma & DC Volts Inputs Operation and Instruction Manual

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Programmable K-Factor Scaler B and Programming Software Kit B

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

DRG-SC Series Signal Conditioners

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Precision Frequency To Voltage Converter Card

Installation, Operation and Maintenance Manual

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

GP-UF/A. Smith Meter Universal F/A Converter. Specifications. Features. Applications. Specifications

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Installation, Operation and Maintenance Manual

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

User s Guide FLSC-45/45B. Paddlewheel Signal Conditioner. Shop online at omega.com

Installation and Operating Manual

TMP-100 Turbine Meter Pulse Divider Circuit

DC Current Transducers

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

TECHNICAL DATASHEET #TDAX021901

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

Analog Servo Drive 20A20

Kotron Sentinel Model 804 RF Level Transmitter

INSTRUCTION MANUAL CLEVELAND-KIDDER TENSION INDICATOR SERIES AO REVISION

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

INSTALLATION & OPERATION MANUAL

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Operating Manual. Model Channel. DC Signal Conditioner Amplifier

Kotron Sentinel Model 804 RF Level Transmitter

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Copyright 2014 by Minarik Drives

LINCO MEASUREMENT MODEL CP-2B MASTER METER PROVER COUNTER INSTRUCTION MANUAL

REPLACING ACC7B WITH CAT2

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

OPERATING INSTRUCTIONS

DIN Thermocouple Conditioner MODEL 5M14(V)

Process Calibrator. TechChek 820

Anacon Power & Controls

DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT TEL: FAX:

MODEL SC170 TWO-WIRE SMART SIGNAL CONDITIONER INSTALLATION AND OPERATION MANUAL

Analog Servo Drive 30A8

Analog Servo Drive 30A8

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

AxCent Servo Drive A50A100

AxCent Servo Drive A25A100

Tel: (949) Fax: (949) IAA100 Product Manual

DM8010 tm. Hardware Reference Manual. Document Revision B3 May 16, 2018

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Nokeval. Operators manual. Signal converter 641. No P

MAE3. Absolute Magnetic Kit Encoder Page 1 of 8. Description. Mechanical Drawing. Features

SIGNAL INTERFACE MODULE

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

SRVODRV REV7 INSTALLATION NOTES

USER S MANUAL PROCESS CONTROL MODULE PCM3

Analog Servo Drive 100A40

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

Digital Lighting Systems, Inc.

DSB810A Digital DC Servo Driver Manual V1.0

User's Manual: Series 250T Model 250T Frequency Input Two-Wire Transmitters

Master Reference Unit

Two-Wire Programmable Transmitter for:

TECHNICAL DATASHEET #TDAX032100

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Signet 9950 Dual Channel Transmitter

Model 2400 Explosion-Proof M/P Converters -- LOCK IN LAST POSITION --

Signal Isolation Module. Instruction Manual SIM

TECHNICAL DATASHEET #TDAX022420

ISOLATED 4-20 ma TRANSMITTERS

Model 805 PWM Proportional Valve / Solenoid Driver with Peak and Hold Control Modes

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

Analog Servo Drive 25A20DD

AD596/AD597 SPECIFICATIONS +60 C and V S = 10 V, Type J (AD596), Type K (AD597) Thermocouple,

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

Non-Submersible Industrial Pressure Transducer

UNIVERSAL INPUT TO PULSE CONVERTER MODULE

Instruction Manual IUC-7X-RTX. X=1: Deg. F. X=2: Deg. F. X=3: Deg. F. X=7: X=1: 1-5 ma X=2: 4-20 ma X=3: 0-1 ma X=7:

C5000 & C5000NF PULSE INITIATOR. Introduction

Contents. USER MANUAL NI ISM-7400 Integrated Stepper

model 101 single channel microphone preamplifier owner s manual Rev C

Programmable Universal Frequency Transducer

TECHNICAL DATASHEET #TDAX Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen P/N: AX030121

MDC VAC Input Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Strain gauge amplifier

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

Transcription:

SC-FI Series Frequency to Current Signal Conditioner 99829 08/27/01

INDEX DESCRIPTION... 1 SPECIFICATIONS... 1 TYPICAL WIRING HOOKUP... 1 INPUT & OUTPUT SETTINGS... 2 "L" OPTION SPECIFICATIONS... 3 "L" OPTION TYPICAL WIRING... 3 "L" OPTION INPUT & OUTPUT SETTINGS... 4 DIMENSIONS... 5 WARRANTY... 5 DECODING PART NUMBER... 5

Description: The SC-FI is a two wire frequency to analog converter that converts a pulse rate input into a output signal proportional to frequency or rate. The input pulse rate is amplified and filtered by the input signal conditioning circuitry. Two forms of input signal conditioning are provided, one for magnetic pickups and the other being an isolated pulse input. The amplified frequency signal is then converted to an analog signal using a precision frequency to analog converter. The output stage derives it s power from the output current loop. The output stage converts the input signal into the desired output range. Multi-turn potentiometers provide for the necessary trimming of span and zero. SPECIFICATIONS: Operating Temperature 32 F (0 C) to 158 F (70 C) High Level Pulse Type: Opto-Isolated Logic 1: 4-30 V Logic 0: 0-1 V Frequency Range: 0-10 khz Fault Protection: Isolation Voltage: 500 V Fast Transient Immunity: 500 V Maximum Rise Time: No Limit Maximum Fall Time: No Limit Reverse Polarity Protection Over Voltage Protection Magnetic Pickup Differential Impedance: 10 kω Frequency Response: 0-3500 Hz Trigger Sensitivity: 30 mv p-p Over Voltage Protection: ± 30 V Frequency to Current Conversion Range Selection: DIP Switch Selectable Available Ranges: 150 Hz, 300 Hz, 600 Hz, 1200 Hz, 2500 Hz, 5000 Hz, 10,000 Hz Factory Default: 1000 Hz Simplified Block Diagram mv 3-30V 10kΩ 10kΩ 3.3kΩ F/V V ref Span Zero V/I Loop Powered 4-20mA Output SC-FI Signal Conditioner Analog Output Accuracy: ± 0.1% Span (@ 20 C) Output Type: Two Wire, Loop Powered Range: (10-50 ma optional) Compliance Voltage: 10 to 40 V Loop Burden: < 10 V (less than 500 Ω) Trim Controls: Zero & Span, non-interacting Span (20 ma) Trim Range: 50% to 100% of full scale Linearity: < ±0.1% Span Output Voltage Effect: < ± 0.002% Span/Volt Temperature Effect: < 200 PPM/C Reverse Polarity Protected Noise Content: < 0.2% Span Response Time: 0.1 second (1 sec. jumper selectable) Over-current Limiting: 35 ma Output Loop Indicator: LED illuminates when output loop is powered by proper polarity and blinks proportionally to the input frequency. Mounting Styles DIN Rail Mount: NEMA 4X: Explosion Proof: Typical Wiring Hookup Magnetic Pickup Hookup Turbine Meter with Mag Pickup Plastic enclosure with a snap fastener for fitting to DIN 46 277 and DIN EN 50 022 assembly rails. 4.92" x 4.92" NEMA 4X Enclosure for wall mounting. Aluminum enclosure for: Class I, Division 1, Groups B, C & D Class II, Division I, Groups E, F & G. ANALOG High Level Pulse Hookup REED SWITCH PULSER ANALOG 1 Magnetic pickup 2 Magnetic pickup 4 Opto-isolator In 5 Opto-isolator In 7 Output 8 Output 1 Magnetic pickup/not 2 Magnetic pickup/con 4 Opto-isolator In 5 Opto-isolator In 7 Output 8 Output 1

SC-FI Signal Conditioner INPUT & OUTPUT SETTINGS REMOVING THE CASE: The case must be removed to change switch settings. To remove the case procede as follows: Refer to FIGURE 1. Using finger tips, carefully pry the case away from the terminal blocks (as shown with dotted lines). Pry far enough to release the restraining clips on both sides of the case. Press up on terminal block with thumbs. The assembly will pop out allowing it to be removed from case. FIGURE 1: OUTPUT ADJUSTMENTS: The unit has two potentiometers for adjustment. The upper potentiometer controls the 20mA setpoint and the lower potentiometer controls the 4mA setpoint (see Figure 2). The 4mA output range can be adjusted from 3mA to 5mA. The 20mA output range can be trimmed from 50% to 100% of the selected range. To adjust the output, initially turn the 20ma adjust 20 turns CW for starting position. 0 frequency and adjust the 4 ma pot. Connect your maximum frequency and adjust the 20 ma pot. FIGURE 2: 20 ma Adjust (CCW-Up, CW-Down) 4 ma Adjust (CCW-Down, CW-Up) LED INDICATOR INPUT FREQUENCY RANGE SETTINGS: The appropriate range is selected by turning ON the corresponding switch. Range: Switch # ON 0-150Hz 1 0-300Hz 2 0-600Hz 3 0-1200Hz 4* 0-2500Hz 5 0-5000Hz 6 0-10000Hz 7 RESPONSE TIME SETTING: Switch #8 controls the output response time. Switch #8 ON Response Time 0.1 second 1 second Turn switch #8 ON to provide damping of the output resulting in a 1 second response time. LED INDICATOR: The SC-FI has a LED which indicates the status of the unit. The table below describes the 3 states for the LED. LED STATUS: ON (constant) MEANING: The unit is off. The unit is loop powered. * Factory Default. The unit is setup at the factory for the range 0-1000Hz. BLINKING The unit is receiving an input frequency. The LED will blink at a rate proportional to the input frequency. (The LED may appear to be constant at high input frequencies) 2

"L" Option SPECIFICATIONS SC-FI Signal Conditioner Description: The SC-FI with option "L" is a two wire frequency to analog converter that converts a pulse rate input into a output signal proportional to frequency or rate. The SC-FI with option "L" is intended for use with lower full scale input frequencies. Full scale frequencies of 15 Hz to 2000 Hz are possible. The unit includes both a contact closure input and an opto-isolated input. Output response time is selectable 1 or 10 seconds. The amplified frequency signal is then converted to an analog signal using a precision frequency to analog converter. The output stage derives it s power from the output current loop. The output stage converts the input signal into the desired output range. Multi-turn potentiometers provide for the necessary trimming of span and zero. Analog Output Accuracy: ± 0.1% Span (@ 20 C) Output Type: Two Wire, Loop Powered Range: (10-50 ma optional) Compliance Voltage: 10 to 40 V Loop Burden: < 10 V (less than 500 Ω) Trim Controls: Zero & Span, non-interacting Span (20 ma) Trim Range: 50% to 100% of full scale Linearity: < ±0.1% Span Output Voltage Effect: < ± 0.002% Span/Volt Temperature Effect: < 200 PPM/C Reverse Polarity Protected Noise Content: < 0.2% Span Response Time: 1 second (10 sec. jumper selectable) Over-current Limiting: 35 ma Output Loop Indicator: LED illuminates when output loop is powered by proper polarity and blinks proportionally to the input frequency. SPECIFICATIONS: Operating Temperature 32 F (0 C) to 158 F (70 C) Mounting Styles DIN Rail Mount: Plastic enclosure with a snap fastener for fitting to DIN 46 277 and DIN EN 50 022 assembly rails. High Level Pulse Type: Opto-Isolated Logic 1: 4-30 V Logic 0: 0-1 V Frequency Range: 0-10 khz Fault Protection: Isolation Voltage: 500 V Fast Transient Immunity: 500 V Maximum Rise Time: No Limit Maximum Fall Time: No Limit Reverse Polarity Protection Over Voltage Protection Contact Closure Sensor Compatibility- Requires an isolated, contact closure Maximum Contact Voltage- 5 V Maximum Contact Current- 0.12 ma Nominal Pullup Resistance - 47 Kohm to 5 Vdc Frequency Range - 0-100 Hz Frequency to Current Conversion Range Selection: DIP Switch Selectable Available Ranges: 30 Hz, 60 Hz, 120 Hz, 240 Hz, 480 Hz, 960 Hz, 1920 Hz Factory Default: 100 Hz NEMA 4X: Explosion Proof: Typical Wiring Hookup (option "L") Contact Closure Hookup Flowmeter with Switch Closure Output High Level Pulse Hookup 4.92" x 4.92" NEMA 4X Enclosure for wall mounting. Aluminum enclosure for: Class I, Division 1, Groups B, C & D Class II, Division I, Groups E, F & G. ANALOG 1 Not Used 2 Contact Closure In 4 Opto-isolator In 5 Opto-isolator In 7 Output 8 Output Simplified Block Diagram Contact Closure 3-30V 5V 47kΩ 3.3kΩ F/V V ref Span Zero V/I Loop Powered 4-20mA Output REED SWITCH PULSER ANALOG 1 Magnetic pickup/not 2 Magnetic pickup/con 4 Opto-isolator In 5 Opto-isolator In 7 Output 8 Output 3

SC-FI Signal Conditioner "L" Option INPUT & OUTPUT SETTINGS REMOVING THE CASE: The case must be removed to change switch settings. To remove the case procede as follows: Refer to FIGURE 1. Using finger tips, carefully pry the case away from the terminal blocks (as shown with dotted lines). Pry far enough to release the restraining clips on both sides of the case. Press up on terminal block with thumbs. The assembly will pop out allowing it to be removed from case. FIGURE 1: OUTPUT ADJUSTMENTS: The unit has two potentiometers for adjustment. The upper potentiometer controls the 20mA setpoint and the lower potentiometer controls the 4mA setpoint (see Figure 2). The 4mA output range can be adjusted from 3mA to 5mA. The 20mA output range can be trimmed from 50% to 100% of the selected range. To adjust the output, initially turn the 20ma adjust 20 turns CW for starting position. 0 frequency and adjust the 4 ma pot. Connect your maximum frequency and adjust the 20 ma pot. FIGURE 2: 20 ma Adjust (CCW-Up, CW-Down) 4 ma Adjust (CCW-Down, CW-Up) LED INDICATOR INPUT FREQUENCY RANGE SETTINGS: The appropriate range is selected by turning ON the corresponding switch. Range: Switch # ON 0-30Hz 1 0-60Hz 2 0-120Hz 3* 0-240Hz 4 0-480Hz 5 0-960Hz 6 0-1920Hz 7 RESPONSE TIME SETTING: Switch #8 controls the output response time. Switch #8 ON Response Time 1 second 10 second Turn switch #8 ON to provide damping of the output resulting in a 10 second response time. LED INDICATOR: The MS660 has a LED which indicates the status of the unit. The table below describes the 3 states for the LED. LED STATUS: ON (constant) MEANING: The unit is off. The unit is loop powered. * Factory Default. The unit is setup at the factory for the range 0-100Hz. 4 BLINKING The unit is receiving an input frequency. The LED will blink at a rate proportional to the input frequency. (The LED may appear to be constant at high input frequencies)

SC-FI Signal Conditioner Dimensions.89 (22.5) Mounting holes molded directly under cover screws. Max. screw head.29" (Typ. 4 places) 4.21 (107) DIN Rail Mount NEMA4X 1.40 (35.5) 2.95 (75) 3.88 (98.5) To access terminals, remove cover and 4 panel screws. WARRANTY This product is warranted against defects in materials and workmanship for a period of two (2) years from the date of shipment to Buyer. The Warranty is limited to repair or replacement of the defective unit at the option of the manufacturer. This warranty is void if the product has been altered, misused, dismantled, or otherwise abused. ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WAR- RANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PURPOSE. 4.21 (107) 4.92 (125) 2.95 (75) 4.92 (125) TOP VIEW PANEL INSTALLED.43 (11).18 (5) SIDE VIEW 1.93 (49) Explosion Proof Enclosure 3/4 NPT (2) HLS. (feed thru hubs) http://www.kep.com 5.06 (129) Decoding Part Number Example SC-FI D ET Series FI= Frequency to Current 7.125 (181) 5.44 (138) 4.06 (103.2) 2 MTG LUGS 0.31 DIA. 5 Mounting: B= Nema 4X C= Explosion Proof D= DIN Rail Options: ET= Extended Temp (-20 to 85 C) L = Low Count Speed for Contact Closure s 50 = 10-50 ma output Accessories: (add to end of part number) DR-4= 4" DIN Rail