DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

Similar documents
MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Magnetic Inductive Flowmeter

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

NGR. Guided Wave Radar Level Transmitter

Full Metal Variable Area Flowmeter and Counter Model BGF

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Electromagnetic flowmeter in all metal design Model MIM

Electro-Magnetic Flowmeters COPA-XE

DUK. Compact Ultrasonic Flowmeter

Ambient Conditions. Operating Conditions. Pressure

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

Coriolis Massflowmeter

Coriolis Mass Flow Meter Model TM

Flow Measurement SITRANS F M

Level Sensors Reed Contact Chain

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

FLOMID FX Electromagnetic Flowmeter

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

OPTIFLUX 1000 Technical Datasheet

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Advanced instrumentation solutions crafted with highest precision

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

JUMO flowtrans MAG S01

NBK-04. Level Indicator for Tank-Top Mounting

EN-2018 MAGNETIC FLOW METERS

RCM DIRECT READING FLOWMETER

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

The transducer component converts the measured signal and displays the actual value.

Flow Measurement SITRANS F M

Electromagnetic Flow Transmitter

Design and applications

WATERFLUX 3070 Technical Datasheet

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

DUK COMPACT ULTRASONIC FLOWMETER

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

INLINE flowmeter for continuous flow measurement

Magnetic-Inductive flow Meter fmi

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

ABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

INSERTION paddle wheel flowmeter for continuous flow measurement

Liquid Level Switches

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

INLINE flowmeter for continuous flow measurement

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

TIDALFLUX 2300 F Technical Datasheet

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Technical Information Proline Promag 10P

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

Magnetic Flowmeter Systems

OPTIFLUX 2000 Technical Datasheet

Coriolis Massflowmeter

Digital flow ELEMENT transmitter for continuous flow measurement

Frame through-beam sensors

INLINE flowmeter for continuous flow measurement

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

Through-beam ring sensors

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic Flow Measuring System promag 35

Digital flow ELEMENT transmitter for continuous flow measurement

BATCHFLUX 5500 C Technical Datasheet

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

Metal tube variable area flowmeters for gases, liquids and steam

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Digital conductivity transmitter

Abridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter

Coriolis Massflowmeter

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

ProcessMaster FEP300 Electromagnetic flowmeter. The process industry's first choice

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

Temperature Transmitters

Mass Flowmeter CoriolisMaster FCM2000

Electromagnetic Flow Measuring System promag 33

Electromagnetic Flowmeter Comet F

Magnetic Inductive Flow Sensors VMI Series

KFS. Flap-type flow meter. Design and range of application

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

FSM4000 Electromagnetic Flowmeter. Measurement made easy. The all-purpose flowmeter for conductive fluids

Magnetic Inductive Flow Sensors induq. Series VMI

Transcription:

Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max : 300 F Connection: Flange ASME ½"... 24" ining : Hard Rubber, Soft Rubber, or PTFE Output: Analog with HART, Pulse, and Status 01/05-2015 KOBOD companies worldwide: ARGENTINA, AUSTRAIA, AUSTRIA, BEGIUM, BUGARIA, CANADA, CHIE, CHINA, COOMBIA, CZECH REPUBIC, EGYPT, FRANCE, GERMANY, HUNGARY, INDIA, INDONESIA, ITAY, MAAYSIA, MEXICO, NETHERANDS, PERU, POAND, REPUBIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERAND, TAIWAN, THAIAND, TUNISIA, TURKEY, UNITED KINGDOM, USA, VIETNAM KOBOD Instruments, Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Main Office: 1.800.998.1020 1.412.788.4890 info@koboldusa.com

Description The KOBOD DMH flowmeter is designed to measure and monitor the volume flow rate of liquids, pulps, pastes, and other electrically conductive media without loss of pressure and can be used in rugged environments. When an electrically conductive media passes through a directional magnetic field, a voltage is induced in accordance with Faraday s aw of Induction. The measured voltage is proportional to the mean rate of flow and consequently also to the volumetric flow rate. The flowmeter consists of a sensor that picks up the measuring signal generated from the induced voltage, and a transducer that converts this signal into a standardized output signal (4-20mA or pulse). The measuring transducer can be connected to the sensor directly or mounted remotely. Pressure, temperature, density, and viscosity do not affect the volume measurement. arge solids and gas bubbles should be avoided. The DMH offers a variety of lining, electrode, and process connection options. The significant properties exhibited by DMH include Great choice of liners SS, Hastelloy, tantalum, titanium, or platinum electrodes Wide variety of process connections Can be used in rough ambient conditions Common Application Media Acids, Alkalis Pastes Drinking Water, Waste Water Technical Data Adj. Measuring Range Terminal Values: 0.5...10 m /s Minimum Conductivity: 5 µs /cm (for iquids in General) 20 µs/cm (Demineralized Water) Accuracy: ±0.3% of read. ± 0.01% x Q max Repeatability: ±0.15% of read. ± 0.005% x Q max (Reference Conditions: Water, Measured Media Temperature of 72 F ±4K, Ambient temperature 72 F ±2K, Inlet 10 x Pipe Diameter, Outlet 5 x Pipe Diameter, Q max at 10 m/s) Process Temperature: 32... +176 F (Hard Rubber, Soft Rubber) -4... 300 F (PTFE) Ambient Temperature: -4... 140 F, Depending on Process Temp. Rated Pressure: ASME 150 lb ½" 24" ASME 300 lb ½" 24" (Higher Pressures upon Request) Tri-Clamp (ISO) ½" 4" (Per Clamp Rating) Sensor s inings: Hard Rubber, Soft Rubber, or PTFE Reference/Grounding Electrodes: Stainless Steel, Hastelloy C4, Tantalum, Platinum, Titanium, (Other s upon Request) Housing: Enameled Steel (DMH-1 & DMH-2) Stainless Steel (DMH-6) Process Connection: Enameled Steel or Enameled 304 Stainless Steel Flange ASME B16.5, Tri-Clamp (ISO) (Other Connections upon Request) Nominal Sizes: ½" to 24" (Other Nominal Sizes upon Request) Protection Type: IP 67 or IP 68 Transmitter UMF2 Display: 2-line, Backlit Flow, Counter (Forward + Backward) Operation: 6 buttons Assembly Type: Compact or Remote Housing: Enameled Die-cast Aluminum, Rotatable in 90 Steps 2

Technical Data (Continued): Outputs Analog: Pulse Output: Status: Power Supply: Galvanically Isolated 1 x 4-20 ma, oad: <600 Ω (>250 Ω for HART ) Passive, using Optocoupler, Max. 30 V, 60 ma, 1.8 W Passive, using Optocoupler Max. 30 V, 60 ma, 1.8 W 115 V AC, 50 / 60 Hz, 10 VA 230 V AC, 50 / 60 Hz, 10 VA 24 V DC ±10%, 10 W / VA Electrical Connection: Cable Connection M 20 x 1.5 or Ambient Temperature: -4 140 F, (Depending on process Temp. for Compact Version) Protection Type: IP 67 or IP 68 Communication: HART Diagnosis Functions: Empty Pipe Recognition, Flushing Flow Monitoring Error Message in Plain Text Measuring Range ine Minimum Measuring Range Maximum Measuring Range Size (GPM) (PM) (GPM) (PM) ½" 1.40 5.30 27.7 105.0 ¾" 1.80 6.81 35.7 135.0 1" 3.90 14.73 77.5 293.3 1.25" 6.38 24.13 127.2 481.6 1.5" 8.53 32.26 170.3 645.0 2" 13.76 52.05 274.7 1040.0 2.5" 24.71 93.52 494.0 1870.0 3" 35.96 136.1 719.0 2722.0 4" 61.03 231.0 1269.0 4807.0 5" 100.5 380.1 2007.7 7600.0 6" 149.5 566.1 2952.1 11175.0 8" 264.2 999.9 5231.3 19803.0 10" 420.8 1592.8 8350.4 31610.0 12" 602.1 2279.0 11963.0 45285.0 14" 732.9 2739.9 14390.7 54475.0 16" 951.7 3602.2 18934.5 71675.0 18" 1206 4561.6 23991.3 90817.0 20" 1501 5680.4 29889.2 113143 24" 2175 8229.8 43333.9 164037 3

Order Details (Example: DMH-1 15 H 11 A 1 6) Model/ Flange Process Connection 1) (Flange acc. to ASME Form B1) iner Reference/ Grounding Electrode Version/ Cable ength Electronic Transmitter Power Supply/ Electrical Connection..15.. = ½", 150 lb DMH-1..= Enameled Steel..20.. = ¾", 150 lb..25.. = 1", 150 lb..32.. = 1.25", 150 lb..40.. = 1.5", 150 lb..50.. = 2", 150 lb..65.. = 2.5", 150 lb..80.. = 3", 150 lb..1h.. = 4", 150 lb..h.. = Hard Rubber..W.. = Soft Rubber..11.. = Stainless Steel..A.. = Compact, IP 67 B... H, IP 67..B.. = Remote Version/2.5 m..c.. = Remote Version/5 m..d.. = Remote Version/10 m..0 = 230 V AC DMH-2..= Enameled 304 SS DMH-6..= Tri-Clamp 304 SS (ISO)..1Z.. = 5", 150 lb..1f.. = 6", 150 lb..2h.. = 8", 150 lb..2f..= 10", 150 lb..3h.. = 12", 150 lb..3f.. = 14", 150 lb..4h.. = 16", 150 lb..4f.. = 18", 150 lb..5h.. = 20", 150 lb..6h.. = 24", 150 lb..t15.. = ½"..T20.. = ¾"..T25..= 1"..T32.. = 1.25"..T40.. = 1.5"..T50.. = 2"..T65.. = 2.5"..T80.. = 3"..T.. = PTFE..T.. = PTFE..33.. = Hastelloy C4..44.. = Titanium..55.. = Tantalum..77.. = Platinum..33.. = Hastelloy C4..44.. = Titanium..55.. = Tantalum..77.. = Platinum..E.. = Remote Version/15 m..f.. = Remote Version/ 20 m..g.. = Remote Version/ 30 m..h.. = Remote Version/ 50 m K... R, IP 68..K.. = Remote Version/2.5 m... = Remote Version/5 m..m.. = Remote Version/10 m..n.. = Remote Version/15 m..p.. = Remote Version/ 20 m..q.. = Remote Version/ 30 m..r.. = Remote Version/ 50 m..1.. = UMF2(B)- Electronics with Control Unit, without HART..2.. = UMF2(B)- Electronics with Control Unit, with HART..4 = 115 V AC..3 = 24 V DC..5 = 230 V AC..6 = 115 V AC..8 = 24 V DC..T1H.. = 4" 1) ASME-flange class 300 lb: code Mxx, other process connections on request Dimensions (mm) Transmitter UMF2(B) 115 205 Connection Box for Sensor, Remote Version 108 75 80 158 57 4

Dimensions (mm) Sensor, Flange Connection A d I D ine Size Flange ASME D d A I Weight* (lbs) ½" 150 95 62 164 200 66 7 ¾" 150 105 62 170 200 66 7 1" 150 115 72 180 200 96 7 1¼" 150 140 82 199 200 96 9 1½" 150 150 92 209 200 96 9 2" 150 165 107 223 200 96 13.5 2½" 150 185 127 244 200 96 20 3" 150 200 142 260 200 96 32 4" 150 220 162 280 250 96 36 5" 150 250 192 310 250 126 42 6" 150 285 218 340 300 126 25 8" 150 340 274 398 350 211 56 10" 150 395 370 480 450 211 120 12" 150 445 420 535 500 320 170 14" 150 505 480 584 550 320 203 16" 150 565 530 642 600 320 256 18" 150 c/f c/f c/f 600 320 340 20" 150 670 640 752 600 320 370 24" 150 780 760 870 600 320 695 Dimension of Tri-Clamp Connection (ISO) PN10 D A (ISO mm) (ISO Inch) [mm] [mm] ½" 74 144 145 137 A ¾" 74 144 145 137 D 1" 74 144 145 137 1½" 94 164 145 137 2" 104 174 145 137 2½" 129 199 200 192 3" 142 227 200-4" 162 247 200 - * Weights of the sensors are only approximate values, please also include the weight of the electronic assembly - approx. 5.6 lbs. 5