Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 285573 Date of issue...: 2015-09-15 Total number of pages... 57 pages Applicant s name...: TDK-Lambda Corp. Address...: 2704-1 Settaya-machi, Nagaoka-shi, Niigata-ken 940-1195, Japan Test specification: Standard...: IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 Test procedure...: Non-standard test method...: Test Report Form No...: Test Report Form(s) Originator...: CB Scheme N/A IEC60950_1F SGS Fimko Ltd Master TRF...: Dated 2014-02 Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report. This Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.
Page 2 of 57 Report No. 285573 Test item description... : DC/DC Converter Trade Mark... : Manufacturer... : Same as Applicant Model/Type reference... : CC10-05..-E, CC10-12..-E, CC10-24..-E, CC10-48..-E (. : see Details of Nomenclature in General Product Information) Ratings... : Refer to Rating(s) General Product Information or
Page 4 of 57 Report No. 285573 List of Attachments (including a total number of pages in each attachment): Photos (3 pages) European Group Differences and National Differences (19 pages) Canadian differences (5 pages) US differences (6 pages) Summary of testing: Tests performed (name of test and test clause): <Report No. 112968> Cl. 1.6.2 Cl. 1.7.11 Cl. 2.1.1.5 Cl. 2.2.2 Cl. 2.10.2 Cl. 4.5 Cl. 5.2 Cl. 5.3.1 General Equipment for building-in Connection to supply Power Interface Durability of Marking Energy Hazard Measurements (Operator Accessible Area) SELV Circuit Hazardous Voltage Working Voltage Measurements Thermal Requirements (Heating Test) Electric Strength Test Component Failure Test Cl. 2.10.3 / 2.10.4 Clearance and creepage distance Cl. 4.5 Thermal requirements Testing location: Nemko A/S P.O. Box 73 Blindern, N-0314 Oslo, Norway This is standard upgrade from IEC60950-1:2005, A1: 2009 /EN60950-1:2006, A11:2009, A1: 2010, A12: 2011 to IEC 60950-1:2005 + Am 1:2009 + Am 2:2013 (2nd Edition) /EN60950-1:2006, A11:2009, A1:2010, A12:2011, A2:2013 Tests are performed in report No. 112968. Tests are not performed in this report. This full revise is partly based on previous handling on report No. 112968, 132878,192369 and 224252. Compliance with requirements regarding buildingin, protection against electric shock and fire hazard must be checked in the end use. The models CC10-05...-E, CC10-12...-E, CC10-24...-E and CC10-48...-E are intended to be supplied from a secondary circuit (SELV) separated from primary circuit by reinforces or double insulation. The models CC10-48...-E is intended to be supplied from Secondary circuit which is separated from primary circuits with reinforced insulation in the equipment, the output was complied with SELV circuits, see Cl. 2.2. The insulation between input and output is functional insulation only. The limit of Transformer T1 is 150 C based on RTI.
Page 5 of 57 Report No. 285573 Summary of compliance with National Differences: List of countries addressed All CENELEC members as listed in EN 60950-1:2006, A11:2009, A1:2010, A12:2011, A2: 2013. The following CB member countries as listed in the IECEE Online Bulletin. The below national differences listed in the CB Bulletin are covered by the National Differences and Group Differences for Europe (Common Modifications, Special National Conditions). IEC 60950-1 ed.2 according to ONLINE CB BULLETIN (Last modification date, 2015-05 *)) - Canadian differences IEC 60950-1 ed.2 according to ONLINE CB BULLETIN (Last modification date, 2014-01-24 *)) - US differences *) The last modified date indicates the last time the standard reference / attachment for this standard was modified. The product fulfils the requirements of IEC 60950-1:2005 (2nd Edition) + Am 1:2009 + Am 2:2013 and/or EN 60950-1:2006, A11:2009, A1:2010, A12:2011, A2:2013. Copy of marking plate: CC10-0505SF-E CC10-0512DF-E CC10-2405SF-E CC10-2412DF-E
Page 6 of 57 Report No. 285573 Test item particulars...: Equipment mobility...: For building-in Connection to the mains...: Not directly connected to the mains Operating condition...: Continuous Loaded to rated output (or system specification) Access location...: Operator accessible Over voltage category (OVC)...: OVC II Mains supply tolerance (%) or absolute mains supply values...: N/A Tested for IT power systems...: No IT testing, phase-phase voltage (V)...: N/A Class of equipment...: Not classified Considered current rating of protective device as part of the building installation (A)...: 1A Pollution degree (PD)...: PD 2 IP protection class...: IPX0 Altitude during operation (m)...: < 2000m Altitude of test laboratory (m)...: < 2000m Mass of equipment (kg)...: <0.1 Possible test case verdicts: - test case does not apply to the test object...: N/A - test object does meet the requirement...: P (Pass) - test object does not meet the requirement...: F (Fail) Testing...: Date of receipt of test item...: (Report No. : 112968) 2008-09 (Report No. : 132878) No testing conducted. (Report No. : 192369) No testing conducted. (Report No. : 224252) No testing conducted. (Report No. : 285573) No testing conducted. Date (s) of performance of tests...: (Report No. : 112968) 2008-09 (Report No. : 132878) No testing conducted. (Report No. : 192369) No testing conducted. (Report No. : 224252) No testing conducted. (Report No. : 285573) No testing conducted.
Page 7 of 57 Report No. 285573 General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause 4.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided...: Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : TDK Yuri-Honjo Corporation, Head Office/Honjo Factory 16-57 Aza-Yamanokami, Ishiwaki, Yuri-Honjo-shi, Akita-ken 015-0014, Japan
Page 8 of 57 Report No. 285573 General product information: The equipment under tests are DC/DC Converter, Models CC10-05...-E, CC10-12...-E, CC10-24...-E and CC10-48...-E for building-in. Rating (s): Model Input Rated Voltage (Vdc) Input Current (ma) Output voltage (Vdc) Output Current (ma) Output Wattage (W) CC10-0503S..-E 4.5-9 2910 3.3-3.6 2500 8.25 CC10-0505S..-E 4.5-9 2910 5-6 2000 10 CC10-0512S..-E 4.5-9 2910 12-15 800 9.6 CC10-1203S..-E 9-18 1670 3.3-3.6 2500 8.25 CC10-1205S..-E 9-18 1670 5-6 2000 10 CC10-1212S..-E 9-18 1670 12-15 1000 12 CC10-2403S..-E 18-36 840 3.3-3.6 2500 8.25 CC10-2405S..-E 18-36 840 5-6 2000 10 CC10-2412S..-E 18-36 840 12-15 1000 12 CC10-4803S..-E 36-76 380 3.3-3.6 2500 8.25 CC10-4805S..-E 36-76 380 5-6 2000 10 CC10-4812S..-E 36-76 380 12-15 1000 12 CC10-0512D..-E 4.5-9 2910 12-15 400 9.6 CC10-1212D..-E 9-18 1670 12-15 450 10.8 CC10-2412D..-E 18-36 840 12-15 450 10.8 CC10-4812D..-E 36-76 380 12-15 450 10.8 Details of Nomenclature: CC10 05 03 S F A E _ I II III IV V VI VII I: Series Type CC10 Series II: Input Rated Voltage 05: 4.5-9V 12: 9-18V 24: 18-36V 48: 36-76V III: Output Voltage 03: 3.3-3.6V 05: 5-6V 12: 12-15V IV: Output Number S: 1 output D: 2 outputs
Page 9 of 57 Report No. 285573 General product information (continued): V: Terminal Construction F: Flow type (DIP) R: Reflow type (SMD) VI: Internal Control Number not affecting safety. Blank: Standard A-Z: Variation VII: Internal Control Number not affecting safety E: The fifth generation Model differences: Model differences in CC10 series are model designation, electrical rating, circuit diagram and some components. For models CC10-05...-E (supply voltage 4.5-9Vdc), the equipment is supplied from SELV. For models CC10-12...-E (supply voltage 9-18Vdc), the equipment is supplied from SELV. For models CC10-24...-E (supply voltage 18-36Vdc), the equipment is supplied from SELV. For models CC10-48...-E (supply voltage 36-60Vdc), the equipment is supplied from SELV. For models CC10-48...-E (supply voltage more than 60V-76Vdc), the equipment is supplied from secondary hazardous circuits (secondary high voltage). Secondary high voltage circuit. Maximum recommended ambient (Tma): 50 C (100% load), 70 C (40% load) for model CC10-...D.-E 35 C (100% load), 75 C (40% load) for model CC10-...S.-E Connection to the supply: Building-in equipment Not intended for direct connection to an a.c. and d.c. mains supply. Circuit characteristics: The equipment contains secondary (SELV) circuits for models CC10-05...-E (supply voltage 4.5-9Vdc). The equipment contains secondary (SELV) circuits for models CC10-12...-E (supply voltage 9-18Vdc). The equipment contains secondary (SELV) circuits for models CC10-24...-E (supply voltage 18-36Vdc). The equipment contains secondary (SELV) circuits for models CC10-48...-E (supply voltage 36-60Vdc). The equipment contains secondary hazard circuits (secondary high voltage) for models CC10-48...-E (supply voltage more than 60V-76Vdc). Secondary high voltage circuit. The models CC10-05...-E, CC10-12...-E, CC10-24...-E and CC10-48...-E are intended to be supplied from a secondary circuit (SELV) separated from primary circuit by reinforces or double insulation. The models CC10-48...-E is intended to be supplied from Secondary circuit which is separated from primary circuits with reinforced insulation in the equipment, the output was complied with SELV circuits, see Cl. 2.2.
Page 10 of 57 Report No. 285573 General product information (continued): The change concern 1) Standard Upgrade: From: To: IEC60950-1: 2005, A1: 2009 and EN 60950-1: 2006, A11: 2009, A1: 2010, A12: 2011 IEC60950-1: 2005, A1: 2009, A2: 2013 and EN 60950-1: 2006, A11: 2009, A1: 2010, A12: 2011, A2: 2013 After review of above described change concern, additional relevant tests and evaluation were considered with the following sub-clauses in this report. 1.1.2 - Additional requirements: Exposure to extreme temperatures, excessive dust, moisture or vibration; to flammable gases; to corrosive or explosive atmospheres: This equipment is intended to operate in a "normal" environment (Offices and homes). Electromedical equipment connected to the patient: This equipment is not an electromedical equipment intended to be physically connected to a patient. Equipment used in vehicles, ships or aircrafts, in tropical countries, or at elevations > 2000m: This equipment is intended to operate in a "normal" environment (Offices and homes). Abbreviations used in the report: - normal conditions N.C. - single fault conditions S.F.C - functional insulation OP - basic insulation BI - double insulation DI - supplementary insulation SI - between parts of opposite polarity BOP - reinforced insulation RI Indicate used abbreviations (if any)