User Manual Digital Clamp Multimeter. model no.: MSR-C600

Similar documents
Model UT201/202: OPERATING MANUAL. Table of Contents

UT207A/208A/209A Operating Manual. Table of Contents

Table of Contents Title Page

UT207/208. Digital Clamp Multimeter P/N:

Model : OPERATING MANUAL Table of Contents (1)

KMD-S04 Multímetro de bolsillo

Table of Contents GDM-356. Page

User Manual Digital Multimeter. model no.: MSR-U1000

Model UT10A: OPERATING MANUAL Table of Contents (1)

Internetowy sklep elektroniczny. Kontakt. Tel Tel. Kom Fax

Model UT20B: OPERATING MANUAL Table of Contents (1)

Digital Clamp Meter Model: &

Model UT50D: OPERATING MANUAL. Table of Contents

DIGITAL CLAMPMETER MODEL

Model UT39A/B/C: OPERATING MANUAL

Model UT233 OPERATING MANUAL

Title Page Overview Unpacking Inspection Safety Information

UT232. Operating Manual. Digital Power Clamp Meter

The Meter Structure The Figure 2-1 shows the Meter structure.

DIGITAL MULTIMETER AUTORANGING

Digital Clamp Meter. User Manual

AC/DC CLAMP METER USER S MANUAL

User Manual Digital Multimeter

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

AMM-1022 Digital Multimeter USER`S MANUAL

OS-81B TECPEL CO. LTD.

Model UT511 OPERATING MANUAL

MANUAL PCE-UT232

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

Sales: Technical: Fax:

DCM730. Digital Clamp Meter User s Manual

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

1.General instructions Specifications Description...7

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

True RMS Digital Multimeter Model:

Handheld Digital Multimeter

CONTENTS MS2033A. 1.Introduction Safety Information...01

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

400Amp True RMS AC Clamp Meter + NCV

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

User Manual. All rights reserved. Specifications are subject to change without notice.

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

UT231. Operating Manual. Digital Power Clamp Meter P/N:

312, 316, 318. Clamp Meter. Users Manual

Digital Multimeter, Pen Type

Model DIGITAL MULTIMETER

Multifunction Digital

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Analog Technologies. Multimeter 15B and17b

DVM1190 DIGITAL MULTIMETER

MS8223A. CAT.IIi 600 V

200Amp AC Clamp Meter + NCV Model MA250

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

Handheld Digital Multimeter

3B SCIENTIFIC PHYSICS

UT132 Series Manual. UT132 Series. Palm Size Digital Multimeter. Operating Manual -1-

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

400Amp True RMS AC/DC Clamp Meter Model EX613

Contents 1. General instructions. 1.1 Precautions safety measures Protection mechanisms. 2. Description. 2.1 Instrument Familiarization. 2.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

DIGITAL MULTIMETER INSTRUCTION MANUAL

User Manual. All rights reserved. Specifications are subject to change without notice.

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

15B & 17B. Users Manual. Multimeters

User Guide. Digital AC/DC Clamp Meter Model 38394

Model UT70C: OPERATING MANUAL. Table of Contents. Page

User s Guide. Digital AC/DC Clamp Meter Model 38394

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

OPERATOR S INSTRUCTION MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Model 77 Series IV. Digital Multimeter. Users Manual

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

ET-3888 True RMS Clamp Meter. User Manual

Not for Reproduction

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Pen-type DIGITAL MULTITESTER

OPERATOR S INSTRUCTION MANUAL

Mini Clamp Meter Model:

ProfiScale MULTI Multimeter

User s Guide. 400A AC/DC Clamp Meter. Model MA220

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

Dawson DDM190. Digital Multimeter User s Manual

Pocket Size Digital Multimeter Models: and

DMM8900 SERIES USERS MANUAL

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

Transcription:

User Manual Digital Clamp Multimeter model no.: MSR-C600

Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly. Warning To avoid electric shock or personal injury, read the Safety Information and carefully before using the Meter. MSR-C600 is 2000-count stable, safe and reliable digital clamp multimeter. It is designed with large-scale integrated circuits and A/D converter as the core as well as the overload protection and novel structure, which make it a superb tool for electricians. The Meter can measure AC/DC voltage, AC current, resistance, diode, continuity and so on. Unpacking Inspection Open the package case and take out the Meter. Check the following items carefully for any missing or damaged part: Item Description 1 Digital Clamp Multimeter 2 Carrying Pouch 3 User Manual Qty 1 pc 1 pc 1 pc Safety Information This Meter complies with the standard IEC61010: Pollution Degree 2, Overvoltage Category (CAT. II 600V, CAT. III 300V) and Double Insulation. CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient overvoltages than CAT. III. CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than CAT. IV Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired. In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test. A Note identifies the information that user should pay attention to. - 1 -

Warning range - 2 -

To avoid any damage to the meter or any accident, do not alter the internal circuit of the Meter randomly. used International Electrical Symbols AC (Alternating Current). DC (Direct Current). AC or DC. Grounding. Double Insulated. Deficiency of Built-In Battery Continuity Test. Diode. Fuse. Warning. Refer to the Operating Manual. Danger of High Voltage Conforms to Standards of European Union. - 3 -

The Meter Structure 1. Input Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Trigger: Push/release it to open/close the clamp jaw. 6. Hand Guards: to protect user s hand from touching the dangerous area. 7. Transformer Jaws: designed to pick up the AC current flowing through the conductor. It could transfer current to voltage. ( Figure 1) Rotary Switch Below table indicated for information about the rotary switch positions. Rotary switch positions OFF A A Ω 2/20A 200/400A Function Power is turned off. DC voltage measurement AC voltage measurement Resistance measurement Continuity/diode test AC current measurement from 0.001A to 400A Functional Buttons Below table indicated for information about the functional button operations. HOLD Press HOLD to enter and exit the Hold mode in any mode, the Meter beeps. MAX Press MAX to start recording and updating of maximum values. SELECT Press SELECT button to switch between and. - 4 -

Functional Buttons Not every functional buttons can be used on every rotary switch positions. Rotary Switch Positions Functional Buttons SELECT MAX HOLD V N/A V N/A Ω N/A N/A N/A A 2/20A N/A A 200/400A N/A Display Symbols (See Figure 2) Not every functional buttons can be used on every rotary switch positions. ( Figure 2) No. Symbol Description 1 AC Indicator for AC voltage or current 2 DC Indicator for DC voltage The battery is low. Warning: To avoid false readings, which could lead to 3 possible electric shock or personal injury, replace the battery as soon as the battery indicator appears. The Meter is in the auto range mode in which the Meter 4 5 automatically selects the range with the best resolution. Test of diode. 6 The continuity buzzer is on. 7 MAX Maximum reading displayed 8 Date hold is active. Ω: Ohm. The unit of resistance. 9 Ω,kΩ,MΩ kω: kilohm.1 x 10 3 or 1000 ohms. MΩ: Megaohm. 1 x 10 6 or 1,000,000 ohms. 10 A Amperes (amps). The unit of current. 11 mv, V Volts. The unit of voltage.mv: Millivolt. 1x10-3 or 0.001 volts 12 Indicates negative reading 13 OL The input value is too large for the selected range. - 5 -

Measurement Operation A. DC Voltage measurement Warning To avoid harms to you or damages to the Meter from eletric shock, do not attempt to measure voltages higher than 600V AC/DC, although readings may be obtained. red black ( Figure3) The DC Voltage ranges are: 200.0mV, 2.000V, 20.00V, 200.0V and 600V. To measure DC voltage, connect the Meter as follows: 1. Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal. 2. Set the rotary switch to V. 3. Connect the test leads across with the object being measured. The measured value shows on the display. Note B. Measuring AC Voltage (See Figure 4) red black Warning ( Figure 4) To avoid harms to you or damages to the Meter from eletric shock, do not attempt to measure voltages higher than 600V AC/DC, although readings may be obtained. The AC Voltage ranges are: 2.000V, 20.00V, 200.0V and 600V. - 6 -

To measure AC voltage, connect the Meter as follows: 1. Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal. 2. Set the rotary switch to V 3. Connect the test leads across with the object being measured. The measured value shows on the display. (See Figure 5) - 7 -

Measuring the tested object that is already removed from the in-line circuit can the in-line circuit can help to obtain a more accurate reading. D.Testing Diodes (See Figure 6) red black ( Figure 6) Warning To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before testing diodes. Use the diode test to check diodes, transistors, and other semiconductor devices. The diode test sends a current through the semicondutor junction, then measure the voltage drop across the junction. A good silicon junction drops between 0.5V and 0.8V. To test the diode out of a circuit, connect the Meter as follows: 1. Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal. 2. Set the rotary switch to 3. For forward voltage drop readings on any semiconductor component, place the red test lead on the component s anode and the black test lead on the component s cathode. - 8 -

Measuring the tested object that is already removed from the in-line circuit can help to obtain a more accurate reading. (See Figure 7) - 9 -

F. Measuring AC Current (See Figure 8) F 8 trigger 4. Sleep Mode To preserve battery life, the Meter automatically turns off if you do not turn the rotary switch or press any button for around 15 minutes. The Meter can be activated by turning the rotary switch or pressing any button with the following conditions: The Hold function will be cancelled if the Meter is activated by pressing the HOLD button. To disable the Sleep Mode function, press and hold HOLD button while turning on the Meter. - 10 -

Specifications 1. 6 Low Battery Indication : Display Tested Opening 2. H - 11 -

3. Display sinewave RMS( AVG response) - 12 -

sinewave RMS (AVG response) RMS value Maintenance This section provides basic maintenance information including battery replacement instruction. - 13 -

Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information. To avoid electrical shock or damage to the Meter, do not get water inside the case. A. General Service Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. To clean the terminals with cotton bar with detergent, as dirt or moisture in the terminals can affect readings. Turn the Meter power off when it is not in use. Take out the battery when it is not using for a long time. Do not use or store the Meter in a place of humidity, high temperature, explosive, inflammable and strong magnetic field. B. Replacing the Battery (See Figure 9 ) Screw ( Figure 9) Warning To avoid false readings, which could lead to possible electric shock or personal injur y, replace the battery as soon as the battery indicator appears. Make sure the transformer jaw and the tets leads are disconected from the circuit being tested before opening the case bottom. To replace the battery: 1. Turn the Meter off and remove all the connections from the input terminals 2. Turn the Meter s case top down. 3. Remove the screw from the battery compartment, and separate the battery compartment from the case bottom. 4. Remove the old battery from the battery compartment. 5. Replace the battery with 2pcs of new 1.5V (AAA) battery. 6. Rejoin the case bottom and the battery compartment, and reinstall the screw. - 14 -

Questions or Concerns? support@etekcity.com visit etekcity.com for more products