Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

Similar documents
Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

Mounting instruction and operating manual. Access Point (UK) HmIP-HAP-UK

Radio System Strobe Wizard Plus Freemask

APA3-1500R STARTER SET WIRELESS SWITCHING

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.

Radio receiver FS20 EAM

FO-TX 2-EC FO-TX 2-OPT FO-RX 2-EC

User Manual March 2008

1 Safety instructions. 2 Device components. Radio bus system. Radio socket outlet adapter for dimming Order No. : Operating instructions

Astra-R Kit Wireless Alarm System Operation Manual

Transmitter System USER S MANUAL. Light Series

AC 3. Active Antenna Combiner. Instruction manual

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Radio Control Installation and Operating Instructions System 4

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

2-/4-Channel flush-mounted transmitter FS20 S4U

Series 1. Remote. Multiple Mode Remote Controlled Electro Stimulation Control Unit. User Manual

B-Tronic EasyControl EC5401B

Antenna Splitter ASA 1. Instruction manual

Installation Instructions RF identification system Read/write head ANT430 ANT431

Eolis io. Notice Instructions Anleitung Handleiding Manuale. Brugsanvisning Käyttöopas Bruksanvisning Veiledning FR EN DE NL IT DA FI SV NO

Operating Instructions K-POWERgrip EWL Always on the safe site.

Awning control system GFM001. Installation and Operating Instructions

Safety. Legal. stageclix is a trade mark of QDES works BV. QDES Works BV shall in no case be liable for damages arising from use of this product.

Thank you for purchasing a qualiton A20i power amplifier!

CCR24T CCR24R. User s Guide WIRELESS TRANSMITTER SYSTEM WARRANTY SERVICE CARD WARRANTY CARD

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.


Product and Applications Description

w w w. p r o l i g h t. c o. u k


IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

Wireless Room Thermostat Installation and Operation Y6630D1007

Installation Instructions RF-identification system Read/write head ANT513

COD GB / 1.0 RBAND/UMS - RBAND/CSM

Operation. 1 of 14. Serial number label

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

Bedienungsanleitung Handsender HS 5 BiSecur

Installation and Operating Manual (p. 32)


Seite 2 Standard-Empfänger. EN Operation Instructions

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

TETRIS User's Guide. High Impedance Active Probe DO177-1

User manual BETSO TCX. 16 channel wireless TC transceiver. 1 Copyright BETSO ELECTRONICS Ltd.

User Manual. ProRF Encoder Transmitter & Receiver

Bedienungsanleitung Handsender HSP 4 BiSecur

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

E205 Long Range Wireless Modem V1.0 Data Sheet

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

AUTOMATE Interior Sun Sensor

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

OCTOPUS CONTROL STATION

Pair of PMR446 Two-Way Personal Radios Model: TP391

Thank you for purchasing a qualiton A50i power amplifier!

1 Safety instructions. 2 Device components. 3 Function. Radio Management Repeater. Operationsmanual

Instruction also available on

PHV RO High Voltage Passive Probe. Instruction Manual

VELA-RX MOTORE 220V 500W

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

HORNET Remote Control Systems

ECOS SRIF Operating Instructions

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Bedienungsanleitung. Instructions d utilisation Emetteur HS 1 BiSecur / HS 4 BiSecur. Bedieningshandleiding

Coin control unit. Operating instructions C 4065

THE COSMO L REMOTE CONTROL

P700-WLS ioprox Receiver

Table of Contents. Stabila LD 320 1

Safety. Operating instructions Communications module ACM WAVE SYSTEM RF for gas meters with Absolute ENCODER AE2 with and without smart valve DANGER

Radio to radio repeater. airrepeater INSTRUCTIONS MANUAL M A

Mist. now you know. Clock Radio with Weather Forecast. Quick Start Guide and User Manual

Rolling code radio system RS 868

Copyright Graupner/SJ GmbH. Manual. mz-4 2 channel HoTT 2,4 GHz transmitter No. S1031

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

RADIOBAND V3 Programming & Installation Manual

SMART TOILET CONTROL

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Operating Instructions

Important safety instructions

Operating Instructions

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

Precipitation Monitor ,

Evaluation Kits EVA 100 and EVA 105

1 Safety instructions. 2 Device components. 3 Function. Radio bus system. Radio socket-outlet adapter for switching Order No. :

Operating instructions Flat-Type Wall-Mounted Radio Control

Digital Electronic Thermostat With RF

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

IEM 200 R UHF receiver. user manual

TMP40. User Manual.

VueNet EasyLink. ver User`s manual External wireless video and audio transmission system for IP cameras HD and UHD in the band

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Transcription:

EN Wireless Receiver E28Q Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) Always read before initial operation! 28509900_E28Q_EN_2012-05-08.doc 1 / 12

1 Data summary and functions 1.1. Scope The E28Q is a 2-channel wireless receiver designed as an open printed circuit board for use in the motor control units of Feig Electronic (e.g. TRI CON and REL CON control units). A cube antenna can be connected to the receiver directly or an external antenna connected via coaxial cable. 1.2. Functions 2-channel design in 27, 40, 433 or 868 MHz Frequency conversion using replaceable radio modules Operating voltage: 10 to 35 V/DC. Standby current under 0.5 watts. Modes of operation: Pulse Open drain outputs (GND switch) QuickLearn (remote learning) 1.3. Data backup Through the use of the optional QuickLog25 plug-in card Save and restore already taught transmitters. 1.4. Symbols used WARNING! Indication of imminent hazard. Non-compliance can lead to severe or fatal injuries and property damage. WARNING! Indication of imminent hazard. Non-compliance can lead to failure, destruction and property damage. WARNING! Indication of imminent electric shock. Non-compliance can lead to severe or fatal injuries. Information / Instructions ESD Hazard Static electricity can lead to an immediate failure or later failure of the control unit. Please keep these instructions so that you have them available if you have any questions later. 2 / 12 28509900_E28Q_EN_2012-05-08.doc

2 Table of Contents: 1 Data summary and functions... 2 1.1. Scope... 2 1.2. Functions... 2 1.3. Data backup... 2 1.4. Symbols used... 2 2 Table of Contents:... 3 3 Safety Instructions... 4 3.1. Basic safety instructions... 4 3.2. Intended use... 4 4 Mounting instructions... 5 4.1. Antenna installation... 5 4.2. Storage and transport conditions... 5 5 Controls / Displays... 6 5.1. Functional description... 6 6 Connection... 7 6.1. Modes of operation... 7 6.2. Teaching the transmitter key... 7 6.3. Deleting codes... 7 6.4. Frequency change (replacing radio module)... 7 6.5. Technical data... 7 7 Remote learning/remote deleting... 8 7.1. QuickLearn-Standard... 9 7.2. QuickLearn-Group functions... 10 8 Data backup... 12 8.1. QuickLog Mounting... 12 8.2. Backing up the memory content... 12 8.3. Restoring the memory... 12 8.4. Environmental protection / Disposal... 12 8.5. Declaration of conformity... 12 28509900_E28Q_EN_2012-05-08.doc 3 / 12

3 Safety Instructions 3.1. Basic safety instructions Work on the control unit - Switch off the supply voltage! - Only switch the voltage on again after you have checked all the connections. Mounting, installation, commissioning and maintenance - Solely by specialists, e.g. by a qualified electrician, who can judge the work-safety conditions. - Based on the directives and accepted rules of engineering. Mounting and operation - The remote control of devices and systems which involve an increased risk of accident (e.g. crane systems) is prohibited! - Observe locally applicable regulations. - Heed accident prevention regulations, VDE and EVU regulations. - Information available from power stations, VDE and employers' liability insurance companies. - No technical modifications may be carried out. Any change will result in a loss of liability and warranty. - Reliable operation is only possible with careful mounting and installation according to these instructions. No guarantee or liability is assumed for damages which arise from noncompliance with these instructions. Disregarding these safety instructions can lead to personal and property damage! 3.2. Intended use Wireless remote control units are only approved for use with devices and systems where a functional problem in the transmitter or receiver does not result in a hazard for people, animals or property or if this risk is covered by other safety equipment. The user must be informed that the wireless remote control of systems with a risk of accidents is only permissible, if at all, with direct eye contact to the system and when the motion range is free of people, animals and objects. Store the hand-held transmitter so that unwanted activation, e.g. by children or animals, is impossible. The wireless remote control units in use work on generally-approved frequencies (ISM bands). The operator of such wireless remote control units is not protected from faults caused by other wireless systems or devices (e.g., wireless systems being operated in the same frequency range such as baby phones, intercoms, etc.). Any use other than the intended use shall be considered improper use for which the manufacturer is not liable. The fitter, electrician or operating organisation bears the risk and the liability here. 4 / 12 28509900_E28Q_EN_2012-05-08.doc

4 Mounting instructions Work on the control unit may only be carried out with the device voltage-free! Danger of death due to electric shock! Non-compliance can lead to severe or fatal injuries. Disregarding these mounting instructions can lead to personal and property damage! Increased inner temperature through direct sun radiation reduces the service life. Water or insects inside the control unit lead to failure or destruction of the control unit. To avoid damage to the control unit: - Protect the control unit from influences of the weather. - Only mount with housing. The radio module can be secured using a cable tie. 4.1. Antenna installation - Do not place the antenna alongside cables, metal bodies or lighting equipment! - Do not fasten the antenna end with or to metallic objects. - To achieve the best range, the antenna must be routed in its entire length. 4.2. Storage and transport conditions Disregard can lead to failure, even after initial operation! Store dry, dust-free and secure against impact and falling. Storage temperature -25 C to +80 C at 30 to 60 % rel. humidity. Transport only with sufficient and well-padded additional packaging. - The existing packaging is not designed as transport packaging. - Damage caused by disregard is not covered by the warranty! 28509900_E28Q_EN_2012-05-08.doc 5 / 12

5 Controls / Displays "SET" key For teaching and deleting transmitters, see page 7 LED s "OUT" - Blinking when learning. - During operation they indicate the channel status (on/off). - Flickers during deleting or if the radio signal of a previously taught transmitter is received. Radio module slot For description, see Frequency change, page 7. Radio module For description, see Frequency change, page 7. Antenna connection For connection of a cube or external antenna. Pay attention to ground ( ) / outer casing when connecting a coaxial cable. Connection Plug connection matching FEIG motor control units. Expansion slot For description, see page 12. 5.1. Functional description Care must be taken that earthing is in line with ESD requirements during all work on the control unit. Otherwise, the control unit could become damaged or destroyed. When a valid code is received, the taught Open Drain output switches to ground. The function triggered by this depends on the motor control unit used (observe the operating manual of the motor control unit). Maximum 100 transmitters can be taught. If 100 transmitters have already been taught in the receiver, no additional ones will be taught in addition; the previously learned codes are not lost. The first transmitter that is taught determines which coding scheme is valid. Either 12 bits, 18 bits or Keeloq transmitter can be taught. That means if the first detected coding was, e.g., 18 bits, only transmitters with 18-bit coding can be taught. After deleting all transmitters, another coding can be learned. 6 / 12 28509900_E28Q_EN_2012-05-08.doc

6 Connection Connect in accordance with the instructions for the motor control unit used and comply with the local regulations such as VDE, electricity generating company, etc. Never switch external voltage to the wireless receiver. If this is disregarded, the receiver will be destroyed immediately and the warranty loses its validity! Connect the cube antenna to Terminal 5 and direct it out of the housing. 6.1. Modes of operation Pulse: The output switches as long as the selected transmitter key is pressed. 6.2. Teaching the transmitter key Mode of operation Programming LED "OUT" indicator Pulse Press the "SET" key 1x briefly Press the transmitter key for 3 s blinks 1 x Pause - blinks 1 x,... flickers If the radio signal is detected, the LED "OUT" Pos. 2 flickers and the output switches. 6.3. Deleting codes Press a "SET" key until the "OUT" switches from "Blinking to "Off". All taught codes are deleted! Deleting individual codes is not possible. 6.4. Frequency change (replacing radio module) If problems occur in the frequency range being used, the receiver can be converted to a different frequency by replacing the radio module. The transmitter and radio module must have the same frequency and the same modulation, e.g. AM/FM. Note the change on the rating plate. - Switch off the supply voltage! - Carefully pull the radio module from the plug-in socket BL1 / "Pos. 3" (see page 6). - Insert a radio module "on the correct side" with the desired frequency. - Switch on the supply voltage. - Delete codes. - Program new transmitters. 6.5. Technical data Frequency: Coding: Operating voltage: Standby: Output: Operating temperature: Dimensions: Weight: - Radio module with 27MHz, 40MHz, 433MHz or 868MHz AM/FM - 12 bit, 18 bit or Keeloq, self-teaching, max. 100 codes (transmitter keys) can be taught - 10V to 35V DC - <0.5W - max. 80V DC 100mA. - -20 C - +50 C at 30 % - 80 % rel. humidity. - 100 mm x 45 mm x 17 mm - Approx. 60g incl. packaging 28509900_E28Q_EN_2012-05-08.doc 7 / 12

7 Remote learning/remote deleting In connection with the hand-held transmitters of the Q-series, this function permits teaching additional transmitters or transmitter keys and also allows removing previously learned codes without direct access to the receiver. During this process, a master transmitter takes care of the remote control. In addition, the S8Q group transmitter has five group functions which you can assign with various functions or terminal equipment at will. The sixth group function applies to all groups. That facilitates both individual as well as group control of various devices. QuickLearn - Standard Is a simple method for teaching additional transmitters (transmitter key) in the receiver. Teaching a button: This is to assign an additional transmitter (transmit button) with the same channel and the same function as the master transmitter (master button). QuickLearn - Group functions Furthermore, the S8Q-..15.. has an expanded QuickLearn function which enables additional functions. Teaching a button: This is to assign an additional transmitter (transmit button) with the same channel and the same function as the master transmitter (master button). Teaching a group: This is to assign an additional transmitter (group) with the same channels and the same functions as the master transmitter (master group). Deleting a button: One key code is deleted. Deleting a group: Delete one or all groups. Deleting all except the master All transmitters and groups except the current master are deleted. Undo the last learning process: The last learning process can be undone within 5 minutes. A delete process cannot be undone. A transmitter that is taught directly on the receiver through the SET keys is considered a master. One receiver can have several masters. If all transmitters except the master are deleted, all masters except the current one are also deleted. A deletion process using the SET keys deletes all codes; deleting individual codes is not possible. Transmitters that only have QuickLearn standard functions have as master only the learn function for one key. No delete function and no group function. 8 / 12 28509900_E28Q_EN_2012-05-08.doc

7.1. QuickLearn-Standard Transmit keys K1-K4 Transmit display Function keys Fig.: S8Q-..04.. (4-channel transmitter) A hand-transmitter from the Q-series is designated as master, which is taught via the SET key, as slave any hand transmitter and as master a compatible hand transmitter that must be retaught. These terms will also be used in the following. Operation Press the function key <3sec. Press the transmit button to be copied Slave Press the transmit key on the slave to be taught Teaching a key QuickLearn series transmitters e.g. S8Q-.04.. (4-channel transmitter) The transmit indicator flashes The transmit indicator flashes quickly Receiver E28Q LED OUT to be taught blinks, Learning mode The LED OUT to be taught flickers, the transmitter key is taught These instructions apply representatively to all transmitters of the Q series that have a QuickLearn standard function. 28509900_E28Q_EN_2012-05-08.doc 9 / 12

7.2. QuickLearn-Group functions Transmit keys K1-K4 Group key Group LED s 1 to 5 Function keys Fig.: S8Q-..15.. (Group transmitter) As master a hand-transmitter from the Q-series is designated, which is taught via the SET key, as slave any hand transmitter and as master a compatible hand transmitter, that must be retaught. These terms will also be used in the following. Teaching a key Operation S8Q-..15.. (Group transmitter) Receiver E28Q Press the function key <3sec. All group LED s are on, selected group blinks. Select the group, press the transmit key to be copied Slave Press the transmit key on the slave to be taught For K1, LED s 1 to 3 are illuminated For K2, LED s 2 to 4 are illuminated For K3, LED s 3 to 5 are illuminated Teaching a group The OUT LED to be taught blinks, Learning mode The LED OUT to be taught flickers, the transmitter key is taught Operation S8Q-..15.. (Group transmitter) Receiver E28Q Press the function key <3sec. All group LED s are on, selected group blinks. Select the group, press the group key (>2 sec.) Slave Select the group to be taught and push the desired transmit button All group LED s are on, selected group blinks 2x. OUT K1 and K2 LEDs blink in succession, learning mode OUT K1 and K2 LEDs flicker, the group has been taught 10 / 12 28509900_E28Q_EN_2012-05-08.doc

Undo the most recent learning process (only within 5 minutes) Operation S8Q-..15.. (Group transmitter) Receiver E28Q Press the function key All group LED s are on, selected group blinks. <3sec. Group LED s 1, 3, 5 are on Press the function key (>3sec). Keep group key pressed (>5 sec.) Group LED s 1 to 5 illuminate successively; after that the group LED s 1,5 and 2,4 flash alternately Deleting a button OUT K1 and K2 LEDs flicker, the last command is invalid Operation S8Q-..15.. (Group transmitter) Receiver E28Q LED s from 1 to 5 extinguish Press the successively; function key >10sec. after that they successively turn on from 5 to 1; then all LED's flicker LED s 2 and 4 flicker LED s OUT K1 and K2 flicker Press any transmit button Slave Press the key ; to be deleted LED s OUT K1 and K2 off Deleting a group Operation S8Q-..15.. (Group transmitter) Receiver E28Q LED s from 1 to 5 extinguish Press the successively; function key >10sec. after that they successively turn on from 5 to 1; then all LED's flicker LED 3 off, LED1,2,4 and 5 flicker LED s OUT K1 and K2 flicker Press the group button Slave Select the group to be deleted and push the desired transmit button LED s OUT K1 and K2 off Deleting all except the master Operation S8Q-..15.. (Group transmitter) Receiver E28Q LED s from 1 to 5 extinguish Press the successively; function key >10sec. after that they successively turn on from 5 to 1; then all LED's flicker LED s 1,3,5 flicker Press the function key again (>3 sec.) Press the group button (>5 sec.) LEDs illuminate consecutively from 1 to 5; then LED s 1, 5 and 2,4 flash alternately LED s OUT K1 and K2 flicker 28509900_E28Q_EN_2012-05-08.doc 11 / 12

8 Data backup Using the QuickLog25 plug in card, the taught codes can be secured on the plug-in card or already secured codes can be restored. applied. Select the desired function with the aid of the DIP1 to DIP3 coding switches on the add-on card. The fourth coding switch, DIP4, is used as write protection. The selected function is implemented when mains voltage is on. 8.1. QuickLog Mounting - Select function, set DIP switch. - Switch off the supply voltage! - Insert the additional plug-in card "the right way round" in the expansion slot "Pos. 7" (see page 6). - Switch on the supply voltage. 8.2. Backing up the memory content ( DIP1=ON, DIP2-DIP4=OFF ) The data will be transmitted to the QuickLog25 plug-in card when the mains voltage is switched on. After a successful backup, the LED OUT K2 is permanently illuminated while the LED OUT K1 blinks 5x. After that, the mains voltage can be switched off and the plug-in card can be removed for safe storage. Error display: If DIP4 is on ON (write protection), the LED OUT K2 and LED OUT K1 blink together 4x. Check the DIP4 setting, repeat the process. 8.3. Restoring the memory ( DIP1=OFF, DIP2=ON, DIP3=OFF, DIP4=ON ) The data are transmitted back from the QuickLog25 plug-in card to the wireless receiver when the mains voltage is switched on. After a successful backup, the LED OUT K1 is permanently illuminated while the LED OUT K2 blinks 5x. After that, the mains voltage can be switched off and the plug-in card can be removed for safe storage. If there is no E28Q data on the add-on card, LED OUT K2 and LED OUT K1 blink together 4x. Back transferring is only possible if the data from an E28Q wireless receiver is on this add-on card. 8.4. Environmental protection / Disposal The wireless receiver does not contain any integrated batteries. Solely RoHS-conforming components are used. Properly dispose of old and defective appliances and device parts in a collecting point! Do not put them in domestic waste! 8.5. Declaration of conformity Declaration of conformity Type E28Q: The manufacturer herewith declares that the receiver meets the requirements in Directive R&TTE 1999/5/EC when used as intended. For further information, please refer to the URL of the manufacturer stated on the unit. 12 / 12 28509900_E28Q_EN_2012-05-08.doc