Why does the Output's TesysT not switch on?

Similar documents
Power connections, minimum and maximum wiring capabilities, tightening torque

Characteristics and functioning

1.0 Introduction. 2.0 Safety/Protection Features. 1.1 Scope. 1.2 Change Management. 2.1 Mismatch Protection. 2.2 Transient Protection

Design Characteristics. FlexDrive II. Series

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Curves TeSys Model U 0 Starter-controllers

Series 92/94 Local Remote Stations

TECHNICAL DATASHEET #TDAX032100

FREQUENCY INVERTER VFR-013 EXTERNAL BUTTONS PILOTAGE. Inoréa Automation & Industry 9 rue du Lugan BEGLES

DFDA5000 Reserve Manual Controller. With Servo Amplifier. Operation Instruction

RUDOLF Digital power analyzer. Advanced Version

2, 4, & 6 Button Application Tool

OVEN INDUSTRIES, INC. Model 5C7-362

SMS control unit for SRK transmitters

MFJ ENTERPRISES 300 INDUSTRIAL PARK STARKVILLE, MS USA

Modbus Communications System for Micrologic A, P, and H Trip Units Class 0613

KNC-SRV-FD423 Series Servo Driver

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

116 Willow Road Starkville, MS USA

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

Product End of Life Notice Rev 3/2017

INTRINSICALLY SAFE DUPLEXER

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

A Super trainer with advanced hardware and software features only found in very expensive equipment.

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

INSTALLATION AND OPERATION MANUAL

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

Inverter Drive /Vector Drive Motors & Controls

ELECTRICAL INSTALLATION OPERATION MANUAL

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

PROFIBUS HUB REPEATER

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

Obstruction Lighting Troubleshooting Manual

116 Willow Road Starkville, MS USA

Applications: Off-highway construction equipment Municipal vehicles Material handling equipment (forklifts, etc.) Ordering Part Numbers:

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

General Specifications FECA-TE /2010. Phone: Fax: Web:

MFJ ENTERPRISES, INC.

with Electronic Assistant

The wireless alternative to expensive cabling...

Multi-purpose Control Application II

IXIAN TM class V 1.5. EC Transmitter This is an evolving document. EC Transmitter IXIAN TM. Features

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

The wireless alternative to expensive cabling...

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

Guidelines to Using a Three Phase Voltage Monitor

TECHNICAL DATASHEET #TDAX INPUTS, 2 BIDIRECTIONAL

DPF-MAC Auto power factor controller

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

Global Water Instrumentation, Inc.

DeviceNet Gateway Unit RCM-GW-DV Operation Manual, Second Edition

with Electronic Assistant

Thruline RF Directional Wattmeters

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Quick Start. DTA Self-Install Guide

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers:

MFJ ENTERPRISES, INC.

KNC-PKS-FD332S-10-80S-AAK-AKH

Connection and Operation (Built-In Controller Package)

FREQUENCY INVERTER VFR-091/092 EXTERNAL BUTTONS PILOTAGE

5 Channel Multifunctional PWM Controller. HomLiCon LCH5T. Technical Specifications

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Sigma 5 - Axis Servo Motor and Cables - Troubleshooting Guide

FAST SAMPLING CONVERTER

POTENTIAL APPLICATIONS OF TEKON ELECTRONICS PRODUCTS

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

GPS Time Server Product Specifications and Installation Data

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

Optical laser distance sensors. Dimensioned drawing

Variable Speed Brushed DC Motor Drive

S11 Adjustable Speed Drive Engineering Specification

THMS WATT WATT PEAK Other Models

COM-POWER OPERATION MANUAL ACS W

TARGETuner Antenna Management System for Screwdriver Antennas

Product Data Sheet. Models 1022/1025/1029C/1032/3629B 3629B. Models 1022/1025/1032. Model 1029C. Model 3629B. Phase Angle Power Control

ServoPac-A TTA-PRO Positioner

VF-nC1 Adjustable Speed Drive Engineering Specification

User s instructions. Page 1 sur 20 AXD-C / AAD-C / DVX-C / DVS-C : User s instructions B

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

INSTRUCTION MANUAL Redox sensor M 1322 C

LPB OMNI Broadcast Transmitter Installation Procedure Checklist

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

DeviceNet Gateway Unit RCM-GW-DV Operation Manual, Fifth Edition

User manual CLIMATIC 60

BC145 SIGNAL ISOLATOR BOARD

D3000 Installation Guide

Foundation Fieldbus Redundant Junction Box

ACH550 HVAC Drive Submittal

Conductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1.

Transcription:

Why does the Output's TesysT not switch on? I- Type of publication Typical application Best know Method (BKM) Troubleshooting guide Level 2 use Internal use Customer II- Product - Product range : - Product family : TesysT LTMR III- Introduction This document describes how to make a diagnostic and understand why you cannot switch on the TesysT Output LO1. The Second page is a flow chart with different steps to solve your problem. The third page is an illustration for each step. Page 1/6

IV- Description START Led Power? OFF CHECK THE POWER CONTROL (1) ON Led Alarm? ON MAKE A DIAGSTIC WITH A HMI OR POWERSUITE (2) OFF 3 wires mode? YES Input 4 =? WIRED INPUT 4 (3) Local / Remote? REMOTE Input 6 =? WIRED INPUT 6 (3) LOCAL PRESS PUSH BUTTON (5) HMI Local mode? (4) Led Fallback? ON CHECK WIRING AND NETWORK PARAMETERS (6) TS* * : TS = Terminal Strip OFF WIRED INPUT 1 (3) Input 1 =? (3) Command Register value? RIGHT VALUE WRONG VALUE - MODBUS, CAPEN, DEVICENET : 704 = 1 - PROFIBUS : Output Command Register = 36 (7) CONTACT TECHNICAL SUPPORT Page 2/6

(1) Check the power control 0 VDC *BD : Power Supply in DC Current : 24Vdc nominal current.you can supply with a voltage between 20.4Vdc and 26.24 Vdc. N *FM : Power Supply in AC Current : 100-230Vac nominal current.you can supply with a voltage between 93.5Vac and 264 Vac. (2) Make a diagnostic with an HMI or PowerSuite You can use the windows of PowerSuite, XBTN410 or LTMCU. For Powersuite, you should be connected and go on the menu : Monitoring/Status : Page 3/6

(3) Wired Input 4 (Stop input) 3 wires : INPUT 1 = INPUT 4 = STOP INPUT 6 = LOCAL / REMOTE 2 wires : INPUT 1 = INPUT 6 = LOCAL / REMOTE Note : In «2 wires» you do not have «Stop button». In the case of using an external power supply to switch on/off a logic input check the current and voltage level put on it (see catalogue of TesysT). (4) Local mode Local mode : select Local mode by removing the wire on the Input 6 -see point (3)-. You control now the TesysT outputs in Local. You have two ways to control the TesysT in Local mode : - by HMI - by Terminal Strip (Logic Inputs) To choose between HMI or Terminal Strip select the mode as indicated below : PowerSuite View V2.5 Patch for FW1.8 HMI : XBTN410 Note : whatever your mode (Local mode by HMI, Terminal Strip or Remote mode) the Stop key on HMI can stop the motor in all modes. This is the same if you use an operating mode 3 wires : the Stop input (input 4) can stop the motor in all modes. Page 4/6

(5) Press push button FWD REV STOP RESET (6) Check wiring and Network parameters - TSXCANKCDFT180T (CanOpen connector) : - Modbus connector (port on Right side) : CABLE OUT ACTIVATE END OF LINE RESISTANCE IF YOU ARE ON THE LAST PRODUCT CABLE IN - LU9AD7 (Profibus connector) : CABLE OUT ACTIVATE END OF LINE RESISTANCE IF YOU ARE ON THE LAST PRODUCT CABLE IN - DeviceNet connector (Phoenix connector) : + 24 VDC 0 VDC CAN_H SHIELD CAN_L Page 5/6

(7) Command register In Modbus, CanOpen and DeviceNet the register 704 controls the Outputs LO1 and LO2. In Profibus, this is the First Output Word which manages the outputs. TesysT Profibus uses MMS profil (TesysU uses MMS and MS profil). Mapping 704 : Bit : 15 LOW SPEED (used in 2 speed mode) T USED 7 SELF TEST RESET FAULT 0 REVERSE (LO2 = 1) FORWARD (LO1 = 1) WORD FORMAT Mapping Command register in Profibus MMS (First Output Word) : Bit : 15 RESET FAULT 7 AUTO MODE RFS* SELF TEST FORWARD 0 REVERSE T USED WORD FORMAT STOP COMMAND LO1 = 1 : Auto Mode and Run Forward (Command register = 36) LO2 = 1 : Auto Mode and Run Reverse (Command register = 33) LO1 = LO2 = 0 : Auto Mode and Stop Command (Command register = 34) Note : The register 704 works on state and the command register works on rising edge. *RFS: Return to Factory Settings V- Limitation This technical resolution was written for the Output LO1. You can use this document for the output LO2. In this case (for output LO2), you should control : - The register 704 = 2 or First Output word = 33 for Profibus (see point -7-) - The terminal strip Input 2 (see point -3-) - Push button for HMI (see point -5-) Page 6/6