NeuroCheck Image Acquisition and Triggering Notes

Similar documents
FSI Machine Vision Training Programs

Applying Automated Optical Inspection Ben Dawson, DALSA Coreco Inc., ipd Group (987)

CircumSpect TM 360 Degree Label Verification and Inspection Technology

Figure 1 HDR image fusion example

Introduction to Machine Vision for New Users

INTRODUCTION TO VISION SENSORS The Case for Automation with Machine Vision. AUTOMATION a division of HTE Technologies

LadyBug LB5900 Programmatic Measurement Commands and Examples

Statistical Pulse Measurements using USB Power Sensors

The Practical use of LED Light Controllers within Machine Vision systems

Advances in Antenna Measurement Instrumentation and Systems

Optimizing System Throughput with the NI PXI ½-Digit FlexDMM

LV-Link 3.0 Software Interface for LabVIEW

Time Matters How Power Meters Measure Fast Signals

TEMPERATURE MAPPING SOFTWARE FOR SINGLE-CELL CAVITIES*

The Practical use of LED Light Controllers within Machine Vision systems

Using interlaced restart reset cameras. Documentation Addendum

Electronic Circuit Breaker ECONOMY REMOTE

VERSION Instead of siding with either group, we added new items to the Preferences page to allow enabling/disabling these messages.

TC 405/30 THERMOCOMPUTER TC 405/30. temp rate. time. rate. temp time. fix prog. memo. pers. Operating Instructions. event kw/h.

Figure 1 The Raith 150 TWO

Electronic Circuit Breaker BASIC FIX

Multiple Light Beam Safety Device. New MLD

Electronic Circuit Breaker ECONOMY SMART. - Number of available output channels: 2 / 4 / 8

Notes on DYNALYZER HVU Usage

Techniques for Extending Real-Time Oscilloscope Bandwidth

True 2 ½ D Solder Paste Inspection

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

USING POWER FASTENER DRIVING TOOLS SAFELY!

ADVANCED PLC PROGRAMMING. Q. Explain the ONE SHOT (ONS) function with an application.

Usability Evaluation of Multi- Touch-Displays for TMA Controller Working Positions

AN0503 Using swarm bee LE for Collision Avoidance Systems (CAS)

XTS: Significantly higher performance and simplified engineering with TwinCAT. products PC Control

Industrial image processing in the quality management of the plastics processing industry

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Special Notice. Rules. Weiss Schwarz Comprehensive Rules ver Last updated: September 3, Outline of the Game

Frequency Hopping Pattern Recognition Algorithms for Wireless Sensor Networks

Measuring Power Supply Switching Loss with an Oscilloscope

Techniques for Extending Real-Time Oscilloscope Bandwidth

VIDEOcheck VVC 120 Test Automation. VIDEOcheck VVC 120. Automatic testing and sorting machine for the 100 % control of mass-produced parts

Audio Analyzer R&S UPV. Up to the limits

A Solution to Contiguous and Overlapping Parts in Sensor Based Vibratory Bowl Feeders

MEASUREMENT OF ROUGHNESS USING IMAGE PROCESSING. J. Ondra Department of Mechanical Technology Military Academy Brno, Brno, Czech Republic

Development and Application of 500MSPS Digitizer for High Resolution Ultrasonic Measurements

MILITARY PRODUCTION MINISTRY Training Sector. Using and Interpreting Information. Lecture 6. Flow Charts.

INTERNATIONAL TELECOMMUNICATION UNION DATA COMMUNICATION NETWORK: INTERFACES

Golden Mask Deep Hunter LE

Mass Spectrometry and the Modern Digitizer

16-Channel Yearly Time Switch TR 648 S DCF

Rapid Array Scanning with the MS2000 Stage

Combinational logic: Breadboard adders

Allen Bradley MMI_sample_loop Sample Logic

ANLAN203. KSZ84xx GPIO Pin Output Functionality. Introduction. Overview of GPIO and TOU

Lens Impact Resistance Testing Plan Revised,

User Manual. Optical Character / Code Verification OCV 7.001

C-W1650S 16 Ga, 1 Wide Crown Stapler

Warlords - Crystals of Power Game Rules. Random Overlay Wild. Scatter

EE 314 Spring 2003 Microprocessor Systems

IVI STEP TYPES. Contents

MAKING TRANSIENT ANTENNA MEASUREMENTS

ToF-AMS DAQ. Joel Kimmel Univ. of Colorado at Boulder & Aerodyne Research, Inc AMS Users Meeting 2007

TABLE OF CONTENTS. References

EDB9300UE Manual. Oscilloscope function

PLK CJ PRODUCT INSTRUCTION PI002 REV Page 1

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles

Microprocessor-based Temperature Controller

C-1116LMA - Automatic Stapler w/ Long Mag

iq-led Software V2.1

WHEN A PLC IS TOO MUCH, AND SPACE FOR

Vision Sensors Inspector. The intelligent vision solution in an easy-to-use sensor package.

Vertical Shaft Plumbness Using a Laser Alignment System. By Daus Studenberg, Ludeca, Inc.

NOVA S12. Compact and versatile high performance camera system. 1-Megapixel CMOS Image Sensor: 1024 x 1024 pixels at 12,800fps

Industrial Engineering Prof. D. K. Dwivedi Department of Mechanical and Industrial Engineering Indian Institute of Technology, Roorkee

Relationship to theory: This activity involves the motion of bodies under constant velocity.

Measuring Distance Using Sound

C-1650P 16 Gauge, 1/2 Medium Crown Stapler

A Kinect-based 3D hand-gesture interface for 3D databases

Make Noise Wogglebug

A HIGH SPEED MICROWAVE MEASUREMENT RECEIVER

Drink Bottle Defect Detection Based on Machine Vision Large Data Analysis. Yuesheng Wang, Hua Li a

2D, 3D CT Intervention, and CT Fluoroscopy

CMOS Digital Integrated Circuits Lec 11 Sequential CMOS Logic Circuits

Projects Connector User Guide

Exercise questions for Machine vision

Study guide for Graduate Computer Vision

Basler. Line Scan Cameras

Keysight Technologies Using a Scope s Segmented Memory to Capture Signals More Efficiently. Application Note

IN-SIGHT 9902L LINE SCAN VISION SYSTEM

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

Page 1. Last time we looked at: latches. flip-flop

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

HP 16533A 1-GSa/s and HP 16534A 2-GSa/s Digitizing Oscilloscope

Project Multimodal FooBilliard

Perceived Image Quality and Acceptability of Photographic Prints Originating from Different Resolution Digital Capture Devices

Pulsed Measurement Capability of Copper Mountain Technologies VNAs

Data Acquisition & Computer Control

ISIS A beginner s guide

Multifunction AC/DC Voltage Tester

Instruction Manual for HyperScan Spectrometer

MASA. (Movement and Action Sequence Analysis) User Guide

Transcription:

NeuroCheck Image Acquisition and Triggering Notes Handout for FSI Machine Vision Training Course Overview of this document and currency of it s information One may divide this document as follows: The first ½ on the subject matter in general The second ½ on parallel processing. This paper was written when NeuroCheck 5.0 was the current version. At that time (compared to now) the terminology for the parallel processing tools was different and more confusing. Also, at that time, there was no explanatory section in the NeuroCheck software manual regarding parallel processing. NeuroCheck 5.1 included these changes (compared to NeuroCheck 5.0) to make parallel processing easier to understand and use: 1. The tool for capturing an image for parallel processing has been renamed from Capture Image Asynchronously to Capture Image in Parallel 2. The tool for initializing parallel processing is now a separate tool Control Image Acquisition rather than a variant of Capture Image Asynchronously. 3. An explanatory section on this has been added to the manual, making some of the explanations in this paper unnecessary. So, for users of 5.1 on, the need for certain portions of this document has been eliminated, and the terminology for paralell processing tools has been eliminated. To support 5.0 users, this document has been frozen. 5.1-on users are advised to: - Keep the above in mind - Translate tool names per #1 and #2 above - Read the paralell processing section of the NeuroCheck 5.1manuals and help files. Process Overview / Terminology An oversimplification of the first stages of a machine vision image is useful: 1. Take the Picture (Image Acquisition) 2. Make the image available to NeuroCheck 3. Transfer the image into the NeuroCheck program For applications requiring taking a picture of a moving part, proper equipment selection evaluates these factors: Interlaced cameras take the picture in two stages. If the item moved significantly during the imaging process, these two stages will occur at different item positions. The remedy is to specify progressive

scan type imaging. This is standard on the CVS-500 (Compact) and a low cost (generally always chosen) option on the CVS-700 (separate-camera machine vision system) Taking the picture can involve waiting for the camera to get ready, and also waiting for the computer/ software to process the trigger signal. This can induce a random delay (example: 0 -.04 seconds) before the image is acquired. If such a variable delay will cause a problem, the remedy is to use our direct hardware trigger. (details below) There are two ways to trigger the image acquisition: Driven by the NeuroCheck program Driven by directly triggering the imaging electronics. This enables extremely fast and repeatable control of the image acquisition process to provide consistent image position on moving processes. To obtain direct hardware triggering capability, select either a CVS-500 series unit (which has this standard as a user-selectable option) or specify the direct hardware trigger option in a CVS-700. In both cases, these options also include ability to force an immediate image acquisition rather than waiting for completion of the camera s current cycle. Terms used to refer to this process are Asynchronous Image Acquisition, Frame Reset and Vertical Reset. (This is a different meaning of asynchronous than that of the NeuroCheck tools with that name.) Then follow the unit specific instructions from the CVS-500 / CVS-700 manual. Sequence for program-driven image acquisition. The check routine is started by a (typically) oneshot triggering device such as an FSI # RET-002 and RET-003 one-shot retro-reflective photo-eye. (The one-shot feature is the most common way to avoid multiple program executions which can occur if the trigger signal is still high when the program is completed and ready to restart) A NeuroCheck capture image tool is inserted, and its execution causes an image acquisition. Program sequence for hardware-trigger driven image acquisition There are many various ways to do this, depending on the system configuration and the requirements of the application. A quick overview of NeuroCheck s tools in this area provides a useful starting point. NeuroCheck Capture Image type tools. NeuroCheck has two types of capture image type tools: Capture Image In a direct hardware trigger context, this tool causes the program to stop on the Capture Image tool and wait for the next image (which will be caused by a direct hardware trigger) Capture Image Asynchronously Used only with a direct hardware trigger, this is a capability / mode which allows a new image to be acquired even if the program has not completed processing the previous image. If an image has already been acquired, the program takes the existing image rather than waiting for the next one. Examples of Capture Image tool based programs for direct hardware trigger applications There are 2 common methods to do this. Here is a basic example of each. For each example, the unit is a single camera, progressive scan CVS-700 ordered with the direct hardware trigger option.

Pre-Trigger method A (typically one-shot ) pre-trigger starts the check routine. It comes to the Capture Image tool (typically the first tool) and waits for an image to be acquired. A short time later the direct hardware trigger triggers an image acquisition; the capture image tool receives it and the program progresses. This specific example is a conveyor belt production line running at 180 feet per minute inspecting parts which are approx 1 foot cubes spaced (center-to-center) 3 apart. So, the inspection rate is 60 parts per minute. For this example, the inspection program takes.1 second to complete after it receives the image. Two retro-reflective photo-eyes are placed successively on the line. The first one is an FSI # RET-002 or RET-003 retro-reflective photo-eye with the one-shot duration set for about 50 milliseconds. (long enough to be easily seen by the software, short enough to be off by the time that the program finishes executing.) 2 downstream from it is a second standard photo-eye (one shot not required). Automatic Restart Method The program is set to restart automatically with zero time delay. A single (non-one shot) photo-eye triggers an image acquisition through the direct hardware trigger input. The program always starts / restarts immediately, and it waits on the Capture Image tool until an image is received. Although this simplifies the required trigger inputs, it does create a need to deal with a few other issues. If programming type devices (mouse/keyboard etc.) are connected, a unit that is running a program that is waiting for the external trigger (particularly if the waiting / time-out time is set to infinity) will be less responsive to the mouse, and this condition is sometimes mistaken for a malfunction/ being locked. The remedy is familiarization, and either giving it a trigger (to allow switch out of automatic mode) or using a windows tool to close NeuroCheck. Also, the standard pre-defined global check routine level I/O are not usable/ used; and instead discrete I/O control is defined using Check or Check function level I/O control, or set/reset I/O tools. Capture Image Asynchronously tool based programs for direct hardware trigger applications. Again, this is a capability / mode which allows a new image to be acquired even if the program has not completed processing the previous image. If an image has already been acquired, the program takes the existing image rather than waiting for the next one. This capability and these tools are designed for use only with the direct hardware trigger option present and enabled. (otherwise the behavior of the system is confusing and not useful) The 2 most common reasons for using this method are: 1. High-speed direct hardware triggered simultaneous image acquisition is required for 4 or more cameras. 2. Very high-speed line, too fast for sequential processing. The next image may be acquired while the program is still being executed on the previous image. As a timing example, imagine an inspection routine which requires.100 sec to execute, broken down as follows:.033 second to acquire the image (and make it available to the program), and.067 seconds for the rest of the processing. With conventional processing methods, the production rate must be kept down to 1 part every.100 seconds, or 10 parts per second for proper operation of the machine vision unit. With this special mode, proper machine vision system operation is maintained down to approx.067 sec. between parts, or about 14.9 parts per second. Machines which are required to track part positions (for reject mechanism control etc.) and

which run in this realm generally require more sophisticated methods than zone-based methods which are common at lower speeds. At 14.9 parts per second, the total time to inspect a part is still.100 sec, but the time between parts is approximately.067 seconds. So, by definition, when this capability is utilized, a part will have traveled farther than the part-topart spacing during the inspection process. Example on use of Capture Image Asynchronously tools/ capabilities due to high speed Beer bottles are traveling down a conveyor at a rate of 20 bottles per second. The brewer is wishes to measure 3-4 dimensions and angles on the neck and cap of each bottle against a set of tolerances, and provide a daily report of the percentage of bottles that fell within those tolerances. He wishes to stick with a standard economical CVS-700 without exotic cameras, but with (economical) 1.4 GHz processing and the direct hardware trigger option. A program is written which (not counting image acquisition) takes.073 seconds to execute including image acquisition, and.04 seconds to execute not counting image acquisition. There is only.05 seconds between bottles, and so the parallel processing capabilities of NeuroCheck are required. The implementer chooses to have NeuroCheck automatically restart itself with no time delay. The program uses two entries of the Capture Image Asynchronously tool. In the first entry, the initialize box is checked, but not the always box. This converts this step to merely an initialization, I.E. it does not capture an image. When the system is switched to automatic, the first capture image asynchronously tool initializes the system and then does nothing else during that session. The next entry does not have any of these of these boxes checked, and this is the actual capture image tool. While the program is still executing, the next bottle arrives and triggers the image acquisition process. The image acquisition begins and occurs in parallel with the execution of the inspection program on the previous bottle. The inspection program completes execution about.01 sec. before the new image is available to it. So the program restarts itself, and waits.01 sec. on the second capture image asynchronously tool until the image is available for the next inspection. Example of use of Capture Image Asynchronously tool on a lower speed system. This application inspects parts which are traveling at high speed, but the inspection rate is only 2 parts per second. The inspection requires 6 views/ 6 cameras, all to be taken absolutely simultaneously. The entire inspection program (including image acquisition) takes.3 seconds. So, parallel processing is not required for speed considerations. However, due to the application requirements, the unit-specific instructions furnished with the CVS-700 said that capture image asynchronously tools must be utilized to assure that all images are absolutely simultaneously. They also included an example of those steps of the program which the implementer entered, and then proceeded to conventional inspection programming. Does use of Capture Image Asynchronously tools introduce one behind processing type complexities into machine design? The simple, direct answer is no. This question usually arises from one of the following 2 areas: 1. If a system is erroneously run using this tool without direct hardware triggering, one behind imaging may occur, raising this question. So, the key thing here is understanding that operation under erroneous setup is not indicative of actual operation.

2. The capability of acquiring one image while inspecting the previous image raises this question. A useful example related to #2 is a PLC-based machine control for removal of individual defective parts (using a reject mechanism) on a production line with regularly spaced parts. The simplest control strategies rely on execution of the entire inspection process (from taking the picture and inspection processing through PLC recognition of the vision system output) while the part is well within a single zone, are so the simplest strategies are valid only up to a certain speed limit.beyond that, a more different strategy is required. As line speeds increase, that speed limit is exceeded just prior to a speed which utilizes the #2 capability. So, a speed-driven requirement for the #2 capability is also a speed-driven requirement for a more complex control strategy. Both are results of high speed, and neither is a cause of or an exact indicator of the other.