OPM 3000 Opacity/Dust Density Monitor

Similar documents
Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

SR Series Self-Contained Two-Color Infrared Thermometers

Ensure reliable and repeatable multi-component gas analysis.

500C Advanced Training Outline

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

General-Purpose Photoelectric Sensor

Submersion/Insertion Toroidal Sensor

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

Kotron Sentinel Model 804 RF Level Transmitter

GE Sensing. Introduction. Wiring Diagrams (Typical) Field Calibration. Installing the Sensor

Series 1000 and 2000 Transmitters with MVD TM Technology

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Kotron Sentinel Model 804 RF Level Transmitter

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

SENTRY Opacimeter. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain I-OPACIMETROSENTRY-v02

6.00 INFRARED ANALYZER

Ultrasonic Displacement Sensor E4DA

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Standard Practice for Opacity Monitor Manufacturers to Certify Conformance with Design and Performance Specifications 1

Installation and Instruction Manual DT Visible Emissions Monitor

Non-Submersible Industrial Pressure Transducer

Shaft Absolute Vibration Monitor Specifications

Universal Voltage Cabled Photoelectric E3JK

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Kotron Model 82 CE RF Level Transmitter

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

User Manual. PolyGard AT-2000 V3. Infrared Refrigerant Gas Transmitter Serial No. AT March, 2009

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Level Lance Model 5100

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Wireless Base Radio. Wireless Transmitters

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches

UTM10 Series Ultrasonic Transit-time Flowmeters

Specification DataFile

A6500-UM Universal Measurement Card

Solitel Vibrating Rod Level Switch

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

Built-in Amplifier Photoelectric Sensor

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Brunata Optuna H. Properties. Counter

Position Indicator model MFC-300/IP. Technical Manual. Licht

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

S11 Adjustable Speed Drive Engineering Specification

Sensor Portfolio for Machinery Health Applications

Load Cell Accessories and Services

DeltaV SIS Hardware Carriers

Electro-Magnetic Flowmeters COPA-XE

Model Q40CT. System Features. Toroidal Conductivity Monitor...

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

PowerFlex 400 AC Drive Guide Specification

Fisher 646 Electro-Pneumatic Transducers

DeltaV SIS Logic Solver

Digital conductivity transmitter

em4 local - Robust Specific characteristics Part number

Fuzzy Temperature Controllers E5AF

LST400 Ultrasonic level / open channel flow transmitter

Global Water Instrumentation, Inc.

Rosemount 3101, 3102, and 3105

Non-Spring Return DuraDrive Modulating Actuator

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Rosemount TM 498CL ph-independent Free Chlorine Sensor

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

CW Lamp Power Supply

Level Measurement Continuous level measurement Radar transmitters

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Solitel Vibrating Rod Level Switch

QPM Series Indoor Air Quality Duct Sensors

LED Displacement Sensor

Conductivity Analyzer

CSI 9330 Vibration Transmitter

9330 Vibration Transmitter

Long Range Metal Body Sensor

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Built-in Amplifier Photoelectric Sensor

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

Rosemount 225. Toroidal Conductivity Sensors. Product Data Sheet July Toroidal Conductivity Sensor LIQ-PDS-225

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

Magnetostrictive Level Transmitter

Model Sono-Trak Transit Time

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Ultrasonic Displacement Sensor E4DA

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Echotel Model 338 Non-Contact Ultrasonic Two-Wire Transmitter for Level, Volume, or Open Channel Flow

2-wire level transmitter

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

Signet 9950 Dual Channel Transmitter

Operation and Maintenance Manual

General Purpose Toroidal Conductivity Sensors

Features. Description. General Specifications. VS Series Inclinometer : Dual Axis, RS232 and Analogue Output

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Transcription:

CMB-PDS-OPM-3000 Product Data Sheet March 2016 Opacity/Dust Density Monitor The Opacity/Dust Density Monitor is a high-performance opacity monitoring system with double-pass transmissometer. Features Sensors Standard USEPA ASTM D 6216 and 40 CFR 60 PS-1 grade optics Alignment viewing port enables the operator to visually check system alignment at anytime during operation Double pass measurement Dual beam measurement assures high sensitivity, freedom from errors due to vibration or minor misalignment Insensitive to ambient light The solid-state light modulation system eliminates possible interference due to ambient light Automatic lamp aging compensation All measurements are made on a ratio basis and are independent of the absolute intensity of the light source Remote Control Unit Three user selectable displays Optional SD Card for program backup and changes Communications via MODBUS RS485 or 4 20mA output CE and (C)UL Listed Password protected settings

March 2016 Opacity/Dust Density Monitor Emerson s Rosemount Analytical stack- mounting transmissometer sensor system consists of an optical transceiver mounted on one side of the stack and a retro reflector mounted on the other. The main light source is electronically modulated and projects a collimated beam of light, which is split into a reference and measurement beam. Emerson s Opacity/Dust Density Monitor ratio measurement technique provides continuous automatic compensation for variations in light source intensity to ensure prolonged instrument accuracy and stability. Since the OPM 3000 is insensitive to the absolute intensity of the light source, it is not affected by light source aging. Specifications Control unit Enclosure Panel mounted IP65/NEMA4X Dimensions 96 x 96 x 64 mm (3.8''x3.8'x2.5''). Power 20.4 to 28.8 VDC < 10 % ripple, 400 ma. Approvals CE and UL Listed Digital Display Selectable pages, LCD backlight Ambient Temperature Range 0 to +50 C (+32 to 122 F) Power Requirements 24 VDC +/- 10 % Communications Modbus RS485 port Battery Backup 7 years typical Transceiver/Reflector Enclosure NEMA 4 watertight enclosure power 120/240 VAC, 50/60 Hz Path Length 3-50 feet (0.9 to 15.2 meters) Optical System Double pass Light Source Aging Compensation: Automatic Light Source Life: 45,000 hours (> 5 years) Ambient Temperature Limits -40 to +130 F (-40 to +54 C) Process Gas Up to 750 F (400 C) High temperature options available. Consult Factory. Stack/duct pressure +5 inch WC, with the proper installation of purge blowers Alignment Verification Built-in, through-the-lens system Standard Mounting Flanges 3 inch IPS, 150 lb. flange, standard Ambient Light Immunity Solid-state electronic light modulation Wiring 2 pair twisted shielded cable, 22 AWG Alarm Time Delay & set point 6 Relays for alarms Alarm Reset Manual or Automatic Analog Outputs Two 12-bit Analog outputs 4-20 ma, with user selectable ranges Maximum range Opacity 99.9 %, With dust option (99.9 % opacity, 2.0 O.D. and 2,000 mg/m 3 ) Calibration check options Manual zero and span calibrate with dedicated zero reflector or Zero with clear stack condition. 2

March 2016 Specifications (cont) Design and Performance Peak and Mean Spectral Response Photopic; 515 to 585 nm, less than 10 % of peak response outside the desired 400 to 700 nm region Angle of View < 4.0 from optical axis Angle of Projection < 4.0 from optical axis 125 mm (max) 4.92'' (max) Calibration Error < +2 % of full scale Response time < 10 second 114.1 mm 4.49'' 3.51 Zero Drift < 1 % (24 hours) 109 mm 4.29'' Calibration Drift < 1 % (24 hours) Standard Control Unit.24 2.52 146.6 mm 5.77'' 122.8 mm* 4.83'' 13mm 0.51 I/O MODULE 197 mm 7.75'' 180 mm 7.08'' 7.2 mm 0.28'' * Note that, including mounting brackets, this dimension is 151 mm (5.94''). 68.5mm 2.7'' 62.9 mm 2.47'' BASE UNIT 13.1mm 0.51'' 75.8 mm 2.98'' Enhanced Control Unit 3

March 2016 Electronic Display Options Standard Controller Dual beam measurement Clear Stack Zero User friendly microprocessor controller Easy to read numercial display Additional features with Enhanced Touch screen Intuitively designed 5.7'' color touch screen user interface with expanded diagnostics 3 numerical and 2 trend display screens Optional SD card for program and data backup Color coded fault display/acknowledgement screen Enhanced Touch Screen 4

March 2016 Electronic Display Comparsion Chart w/touch Screen Option Standard ASTM D 6216 and PS-1 compliant optics Communications via 4-20 ma and RS MODBUS Clear stack zero calibration Microprocessor controller 3 numercial display screens Intuitively designed icon driven navigation Standard 3 analog outputs Icon driven 5.7'' color touch screen user interface Standard program includes % opacity, mg/m3 and O.D. Optional 2GB SD card for program and data backup Real-time diagnostics for testing outputs and relays Two selectable trend screen displays Easy to read color coded fault screen User display customization available 5

March 2016 Dimensional Drawings Air purge/weather cover mechanical installation 12.250 in. R (311 mm) 6.125 in. (156 mm) 7.5 in. R (191 mm) 6.125 (156 mm) 6 to 8 in. (152 to 203 mm) 6 to 8 in. (152 to 203 mm) Vertical Axis Top View * Side View ** Leave 3 in. (76 mm) clearance from flange face for swinging Cover in Upright Position 21.00 in. (533 mm) (2) Covers Stack or Breeching Wall OD Retro Minimum Swing Clearance 34 in. (863.6 mm) From Flange Center Transceiver Gas Flow 30.5 (775 mm) (3) Covers Optional Weather Cover 60 in. (1524 mm) Optional Weather Cover Platform Platform *Note 1: The top view represents the transceiver and retro reflector assemblies with their swing clearances. Optional weather covers are not shown. **Note 2: The side view represents the installation and swing clearance dimensions for the optional weather covers. 6

March 2016 Flange to stack installation detail Vertical Axis 7,5 in. (191 mm) Dia. Stud Anchors Outside Wall Surface Field Weld Mounting Nipple to Pipe Flange and Metal Stack/ Duct Wall Outside Wall Surface 6 in. (191 mm) Bolt Circle Field Weld Pipe Flange to Mounting Nipple Pipe Flange 6 to 8 in. (152-203 mm) Clearance Masonry Stack Wall Installation 3 in. SCH 40 Mounting Nipple 6 to 8 in. (152-203 mm) Clearance Metal Wall Stack or Duct Installation 7

March 2016 Ordering Information Opacity/Dust Density Monitor - High performance opacity monitoring system with double-pass transmissometer. Model Product Description Opacity/Dust Density Monitor Non-compliant Intelligent Electronics 01 Basic Unit Digital Display, (2) 4 20 ma Outputs, (6) Alarm Relays, RS 232/485, Modbus 02 Enhanced Control Unit with 5.7'' LCD Color Touch Screen and SD Memory Storage Transceiver and Path Length 11 3 15' Path Length 12 >15 21' Path Length 13 >21 40' Path Length 14 >40 50' Path Length Weather Cover and Blower 00 None 01 Weather Covers 02 Weather Covers & Single Blower with Tee 03 Weather Covers & Dual Blowers Zero Jig Type 00 None 01 Zero Jig, 75 % Neutral Density Filter and carrying case Calculation 01 Opacity Calculation (%) for Standard Controller 02 Dust Density Calculation (mg/m 3 ) for Standard Controller 03 Opacity and Dust Density Calculation (for Enhanced Controller Only) 8

March 2016 Ordering Information Technical details required at time of order Customer Company Name: Location: Contact: NOTE: Please submit separate forms per monitor ordered. The Opacity Monitor you have purchased will be individually built according to the information requested below. While utilizing a basic design each unit is set up and adjusted to meet the requirements set forth by your parameters. The unit is then tested based on these strict requirements to be able to perform at these parameters. If the actual parameters are in fact not the same as those stated below, the unit may need to be returned, readjusted and retested at significant cost to the customers account. It is for this reason that we ask you to carefully fill out the information requested in this form. NOTE: This sheet MUST be completed and submitted with purchase order. Factory requires this sheet to build product. Failure to submit this sheet will result in delay. Toll Free: +1 855 724 2638, F: +1 949 474 7250, Email: Gas.CSC@Emerson.com Information Supplied by (name): NOTE: All fields in below chart are required. Measurements must be identified with units (in, ft, mm, cm, etc.) Description Unit identification (i.e., boiler 1, Unit 2B, etc.): Stack exit I.D. (A) on page 2: Flange - to - Flange distance (B) on page 2: I.D. at measuring point (C) page 2: Correlate opacity to dimension (A) or to (C)? Blower Supply Voltage: 120/220 VAC (50/60 Hz)? Accessory power such as air purge blower if ordered: 120 or 220 Vac (50/60 Hz) (A) Stack Exit ID Measurement: (B) Flange-to-Flange Measurement: Min/Max: 36 inches to 46 feet (91 cm to 12 meters,) over 15 feet (4.5m) requires optional reflectors. Selection (C) ID at Measuring Point: Ratio range of A/2 *C must fall between 0.3 and 1.5 Notes: 1. The stack or duct mounting flange should have a minimum O.D. of 6 inches for installation of flange bolts 2. Measurement tolerance A, B and C must be +/- 1 inch (254 mm) or 1 % of the total whichever is the smaller. In all cases the mounting flanges must be installed so that the flange-to-flange measurement (B) is greater than two (2) times the stack exit diameter (A) due to gas flow turbulence. Description Communication RS/485, Baud rate (default 9600) Modbus: Data Bits (default 8) Parity (default none) Flow Ctrl (default none) Time out (default 0.5 seconds) Field selectable Node I.D.# (default 1) Selection 9

March 2016 NOTE: If Modbus information is not filled in, our default values will be used. Only Modbus I.D. is field selectable. Other parameters are fixed at time of final test according to the values given above or default. If changes to the communications are required after the system is shipped changes to the program must be made. All labor and shipping costs to make changes will be charged to the customer. 10

March 2016 Ordering Information (con t) Choose the drawing below that best fits the installation. A B C Mounting Flange A Minimum of 2 stack diameters B C Mounting Flange 11

CMB-PDS-OPM-3000 Product Data Sheet March 2016 YouTube.com/user/RosemountAnalytical Twitter.com/Rosemount_News Analyticexpert.com Facebook.com/Rosemount 2016 Emerson Process Management. All rights reserved. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Toll Free +1 855 724 2638 F +1 949 474 7250 Gas.CSC@Emerson.com The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.