Wind Transmitter - with frequency output xx.xxx

Similar documents
Wind Transmitter - with analogue output xxx

Wind Transmitter compact xx

Wind Transmitter - compact

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Direction Transmitter First Class analogue output x0.1xx

Combined Wind Transmitter - with analogue output xxx

Wind Transmitter First Class

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

Precipition Sensor with analogue Intensity Output ,

Wind Transmitter First Class / 141 / / 141 / 161

Precipitation Monitor ,

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Wind Direction Transmitter First Class analogue output x0.1xx

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Wind Direction Transmitter - compact - GMR, analogue output xxx

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

Wind Direction Transmitter - compact - with serial output x0.x00

Brightness Transmitter

Wind Direction Transmitter - compact

Wind Transmitter compact xx

Hygro-ThermoTransmitter-compact xxx

Baro Transmitter PTB x1.073

Brightness Transmitter - direction-independent xxx

Precipitation Transmitter / 008 / 009 / 010 / 011 / 107 / / 009

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

Precipitation transmitter

Digital Anemometer

Precipitation Transmitter xxx / xxx

WIND VANE THIES FIRST CLASS 2014 TMR

Sensor PAR xxx

Baro Transmitter xxx

WIND VANE THIES COMPACT TMR

WIND VANE THIES COMPACT

Top spin Nr /

THE WORLD OF WEATHER DATA Measurement and Documentation: Thies range of service for meteorology, environmental protection and industry

Operating Instructions K-POWERgrip EWL Always on the safe site.

HEXAGON Cultivator. Operating manual. Manufacturer: CLEMENS GmbH & Co. KG Maschinenfabrik Rudolf - Diesel - Straße Wittlich / Mosel Germany

- 4 - Fig. 3b. Fig. 1b. Fig. 2. Fig. 2b MT 300

Flow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications

Snow Scale SSG. Snow measurement system. Assembly instructions Sommer GmbH. All rights reserved.

LENORD. +BAUER... automates motion. GEL 2351 with current or voltage interface. Technical information Version General. Features.

OPERATING INSTRUCTIONS

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

XY-Stages series 5102

7. Operating instructions: EFL 300

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Instruction manual for STA 1 sectional door operator

...thoroughly tried and tested!

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Assembly instructions Pantograph shutters

T22. Torque transducer. Special features. Data sheet

T22. Data Sheet. Torque transducer. Special features. Installation example with two bellows couplings. B en

Instruction for Use /10/17

COFFEE LABORATORY WHITE STONE VA TEL

Instruction manual for STA 1 sectional door operator

Astra-R Kit Wireless Alarm System Operation Manual

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

DA 30 High Torque Technical Specification

XXXX e. X d.. X X X a

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

ADDUCO Hydraulic Clamping Nut

Magnetic Inductive Flow Sensor induq

ProGap Microwave barrier

Overview of types. Technical data

Instruction Manual MSC710 MSC710-U MSC710-I

Installation and Operational Instructions for ROBA -DS couplings Type 95. _ (disk pack HF) Sizes

Operating Instructions for Microwave Level Switch. Model: LNM

LENORD. +BAUER... automates motion. Magnetic incremental encoder GEL 293 for heavy duty applications. Technical Information Version 04.

Torque Sensor Series 3000 and Series 4000

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

MODEL D DIESEL PILE HAMMER

Assembly instructions for cable termination frame (2-5 bays)

XXXX e. X d.. X X X a

ASSEMBLY INSTRUCTIONS. Construction type approved Reg. no S819 F ENERGY AND SANITARY SYSTEMS

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Resistance Thermometers Model Series TR7X0, Sheathed Design

ProHead. User s Guide

GENERAL OPERATIONAL PRECAUTIONS PRECAUTIONS ON USING CUT-OFF MACHINE

Model:CB-MRC. Instruction Manual of Mini Recessed Motorized Screen

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Enhanced Sidelobe Suppression

User guide ProHead Plus

Selection BASIC LINE BASIC LINE PLUS VARIO LINE SERIES TUBE LINE STEEL LINE

ACCESSORIES CATALOG BORING AND FACING HEADS LIVE CENTERS

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

DTMA-1800-UMTS-12-AISG

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

OPERATING INSTRUCTIONS MODULGRAV. Tel. +49 (0) Fax +49 (0) homepage:

Single Band 125mm Profile Panel Antennas Installation and Operation Instructions Including APM-F-084-S4 & APM-T-085-S4 Mounting Kits

PUSH-PULL-PROPS. and accessories ROBUSTA-GAUKEL GMBH MOUNTING TECHNOLOGY &CO.KG

Instructions for Stone Cutting Machine

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

OPERATION AND MAINTENANCE MANUAL. mcr TLB ECO GATES

SEPARATOR P20G TYPE USER S MANUAL

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

LENORD. +BAUER... automates motion. GEL 2037 with heavy duty flange or tooth wheel adapter. Technical information Version General.

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021531/11/09 Wind Transmitter - with frequency output 4.3303.xx.xxx ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com

Safety Instructions Before operating with or at the device/product, read through the operating instructions. This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - Endangering of persons by electrical or mechanical effect - Damage to objects Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG. Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG should be used for repairs. Electrical devices/products must be mounted and wired only in voltage-free state. Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no modifications have been made to the mechanics, electronics or software, and that the following points are observed: All information, warnings and instructions for use included in these operating instructions must be taken into account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring system / device / product. The device / product is designed for a specific application as described in these operating instructions. The device / product should be operated with the accessories and consumables supplied and/or recommended by Adolf Thies GmbH & Co KG. Recommendation: As it is possible that each measuring system / device / product under certain conditions, and in rare cases, may also output erroneous s, it is recommended using redundant systems with plausibility checks with security-relevant applications. Environment As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the objectives of environmental protection and is therefore willing to take back all supplied products governed by the provisions of "ElektroG" (German Electrical and Electronic Equipment Act) and to perform environmentally compatible disposal and recycling. We are prepared to take back all Thies products concerned free of charge if returned to Thies by our customers carriage-paid. Make sure you retain packaging for storage or transport of products. Should packaging however no longer be required, arrange for recycling as the packaging materials are designed to be recycled. Documentation Copyright Adolf Thies GmbH & Co KG, Göttingen / Germany Although this operating instruction has been drawn up with due care, Adolf Thies GmbH & Co KG can accept no liability whatsoever for any technical and typographical errors or omissions in this document that might remain. We can accept no liability whatsoever for any losses arising from the information contained in this document. Subject to modification in terms of content. The device / product should not be passed on without the/these operating instructions. 2-16 021531/11/09

Contents 1 Models... 4 2 Application... 4 3 Construction and Mode of Operation... 5 4 Recommendation Site Selection / Standard Installation... 5 5 Installation... 5 5.1 Mounting of the cup star... 6 5.2 Electric Mounting... 6 5.3 Mechanical Mounting... 7 6 Maintenance... 7 7 Connecting Diagrams... 8 8 Technical Data... 9 9 Dimensional Drawing... 13 10 EC-Declaration of Conformity... 14 3-16 021531/11/09

1 Models Order-No. Measuring range Electrical Output 4.3303.10.000 0,3...50 m/s 3 1042 Hz (with Offset) 4.3303.10.007 0,3...50 m/s 3 1042 Hz (w/o Offset) 4.3303.22.000 0,3...50 m/s 3 1042 Hz (with Offset) 4.3303.22.001 0,5 50 m/s 3... 1042 Hz (with Offset) 4.3303.22.007 0,3...50 m/s 3 1042 Hz (w/o Offset) 4.3303.22.007D 0,3...50 m/s 3 1042 Hz (w/o Offset) 4.3303.22.008 0,5...75 m/s 0 754 Hz (with Offset) 4.3303.22.018 0,5...75 m/s 0 754 Hz (w/o Offset) 4.3303.22.101 0,5 50 m/s 3... 1042 Hz (with Offset) 4.3303.22.600 0,3...60 m/s 3 1251 Hz (with Offset) 4.3303.22.707 0,3...75 m/s 3 1490 Hz (w/o Offset) Heating Connection Model w/o 5 pole plug Standard w/o 7 pole plug Standard 24V / 20W 5 pole plug Standard 24V / 29W 5 pole plug with reinforced cup star 24V / 20W 7 pole plug Standard 24V / 20W 7 pole plug Cup star with tapered seam 24V / 20W 5 pole plug with reinforced cup star 24V / 20W 5 pole plug with reinforced cup star 24V / 20W 5 pole plug Ship model: - reinforced cup star, - special ball bearings 24V / 20W 5 pole plug Standard 24V / 20W 7 pole plug with reinforced cup star with offset = live zero / w/o Offset = no live zero 2 Application The wind transmitter is used for the registration of the horizontal component of the wind velocity. The will be placed at the output as digital signal (frequency). The signal can be given to display instruments, recording instruments, datalogger as well as process control systems. For winter operation, the instrument is equipped with an heating system in order to guarantee a smooth running of the ball bearings and to avoid ice-formation at the shaft and slot. Power supply unit, Order no. 9.3388.00.000 provides the transmitter and the heating system with current. It is advisable to attach Lightning rod, Order no. 4.3100.99.000 in areas with considerable lightning activity. 4-16 021531/11/09

3 Construction and Mode of Operation A low-inertia cup star ( in ball bearings) made of aluminium, is set into rotation by the wind. The rotation is scanned opto-electronically, is converted into a square wave signal and output. The frequency of this signal is proportional to the number of rotations. The output amplitude ranges between the maximum output voltage (15 V) and the ground (w/o offset resp. no live-zero) or a potential (with offset resp. life-zero), which is raised by approx. 1 V, see chapter 8 Technical Data. The supply of the electronics can be done by DC-voltage of 4 V up to 42 V at a very low current consumption. An AC- or DC-voltage of 24 V is intended for the separate supply of the optional heating.. The heating prevents the wind transmitter from blocking under meteorological icing conditions. The outer parts of the instrument are made of corrosion-resistant anodised aluminium. Labyrinth gaskets and O-rings protect the sensitive parts inside the instrument against humidity and dust. The instrument is mounted onto a mast tube; the electrical plug-connection is located in the transmitter shaft. The following parts are included in delivery: 1 Case 1 Cup star 1 Connection plug 4 Recommendation Site Selection / Standard Installation According to international regulations, the surface wind should be measured at a height of 10 m above flat, open terrain, in order to achieve comparable values. An open terrain is defined as terrain where the distance between the wind-measuring instrument and the next obstacle is at least ten times the height of this obstacle (see VDI 3786, Part 2). If the regulation cannot be adhered to, the measuring instrument should be installed at a height at which the measurement values are not influenced by any local obstacles. In any case, the measuring instruments are to be installed at a height of 6 to 10 m above the mean height of the buildings or trees in the vicinity. If it is necessary to install the instrument on a roof, it should be installed in the centre of the roof in order to avoid any preferential directions. 5 Installation Attention: Storing, mounting and operation under weather conditions is permissible only in vertical position, as otherwise water can get into the instrument.. 5-16 021531/11/09

Remark: When using fastening adapters (angle, traverses, etc.) please take a possible effect by turbulences into consideration. 5.1 Mounting of the cup star Unscrew the cap nut (SW 8) from the wind velocity sensor case and remove the disk. Keep the rubber sealing washer in the protection cap. Set the cup star into position in such a way that the dowel pin in the cup star catches in the nut of the protective cap. Replace the disk and re-screw the cap nut. Hold the transmitter on the protective cap not on the cup. 5.2 Electric Mounting A shielded cable with a diameter of 5..8 mm and a core section of 0,5 0,75 mm² must be soldered on to the enclosed plug. The number of required cores, and the PIN assignment is stated in the connection diagram (chapter 8).. Cable recommendation Type/ No. of cores /Diameter LIYCY 3 x 0,5 mm² LIYCY 5 x 0,5 mm² Cable diameter ca. 5 mm ca. 7 mm 6-16 021531/11/09

Coupling socket 201061 (7pole), type Binder, series 691 1. Removing Coupling socket 2. Stringing coupling socket on cable 3. Cutting cable sheath and shield 20 mm 4. Putting uncovered shield backwards onto the cable sheath 5. Stripping uncovered cable cores 5 mm 6. Pushing shrink hose over cable cores 7. Soldering stripped cable cores onto the solder flag, pushing shrink hose over the soldering afterwards, and shrinking it. 8. Fastening cable in the carrier sleeve by means of the clamp. 9. Mount coupling socket 5.3 Mechanical Mounting Mount the transmitter to a short piece of pipe of R 1½ (Ø 48 mm) and a length of 50 mm. The short piece of pipe must have an internal diameter of at least 36 mm as the wind transmitter must be connected electrically with a plug from below. Once the electrical connection has been carried out, set the wind transmitter onto the short piece and fasten it to the shaft with the two hexagonal screws. 6 Maintenance If properly installed, the instrument requires no maintenance. Heavy pollution can lead to blockage of the slot between the rotating and the stable parts of the transmitter. Thus it is advisable to remove the accumulated dirt from the instrument. 7-16 021531/11/09

Remark: Please use only original packing for transporting the instrument. 7 Connecting Diagrams Order-no. output signal 4.3303.10.000* 3... 1042 Hz = 0,3... 50 m/s 4.3303.22.000 3... 1042 Hz = 0,3... 50 m/s 4.3303.22.600 3... 1251 Hz = 0,3... 60 m/s 4.3303.22.001 5... 1251 Hz = 0,5... 75 m/s 4.3303.22.101 5... 1251 Hz = 0,5... 75 m/s 4.3303.22.008 3. 754 Hz = 0,5... 75 m/s 4.3303.22.018 3. 754 Hz = 0,5... 75 m/s 5 pol. Binder Steckverb. / Plug 1 2 3 4 5 Versorgung DC Power DC G N D Ausgangssignal Output Signal Heizung Heating 20 W Hz Versorgung / Power Heizung / Heating Hz 24V AC / DC 20W Schirm Shield Erde Earth * Instrument without heating, pins 4 + 5 are not connected Order-no. PIN Name Function View on the soldered side of the coupling socket 4.3303.10.000* 4.3303.22.000 4.3303.22.600 4.3303.22.001** 4.3303.22.101 4.3303.22.008 4.3303.22.018 1 +U B supply 4... 42 V DC 2 GND ground 3 SIG output signal (frequency) 4 5 HZ heating supply: voltage: 24 V AC/DC power: 20 (29**)W * Instrument without heating, pins 4 + 5 are not connected ** Heating power: 29 W 4 5 3 2 1 8-16 021531/11/09

Order-no. Output signal 4.3303.10.007* 3... 1042 Hz = 0,3... 50 m/s 4.3303.22.007 3... 1042 Hz = 0,3... 50 m/s 4.3303.22.007D 3... 1042 Hz = 0,3... 50 m/s 4.3303.22.707 5... 1490 Hz = 0,3... 75 m/s 7 pol. Binder Steckverb. / Plug 1 2 3 Heizung Heating 20 W 4 5 6 7 Hz Hz Schirm Shield Versorgung DC Power DC G N D Ausgangssignal Output Signal Versorgung / Power Heizung / Heating 24 V AC / DC 20 W Erde Earth * Instrument without heating, pins 4 + 5 are not connected Order-no. PIN Name Function View on the soldered side of the coupling socket 4.3303.10.007* 1 +U B supply 4... 42 V DC 4.3303.22.007 2 GND ground 4.3303.22.007D 3 SIG Output signal (frequency) 3 4 4.3303.22.707 4 HZ Heating supply: voltage: 24 V AC/DC 2 7 5 5 power: 20 W 1 6 6 NC Not connected 7 NC Not connected * Instrument without heating, pins 4 + 5 are not connected 8 Technical Data Remark: For wind transmitters without heating the stated ambient temperature is possible only under ice-free conditions. 9-16 021531/11/09

Order-no. 4.3303.10.000 4.3303.10.007 4.3303.22.000 4.3303.22.001 Measuring range 0,3... 50 m/s 0,3... 50 m/s 0,3... 50 m/s 0,5... 50 m/s Starting velocity 0,3 m/s 0,3 m/s 0,3 m/s 0,5 m/s Max. load 60 m/s 60 m/s 60 m/s 60 m/s Accuracy Electrical output Frequency Form Amplitude Output signal (U L, U H ) unloaded ± 0,3 m/s resp. 2 % of 3... 1042 Hz (= 0,3... 50m/s) with offset ± 0,3 m/s resp. 2 % of 3... 1042 Hz (= 0,3... 50m/s) w/o offset U L 0 V ± 0,3 m/s resp. 2 % of 3...1042 Hz (= 0,3... 50m/s) with offset U L 1 V ± 0,5 m/s resp. 2 % of 5... 1042 Hz (= 0,5... 50m/s) with offset U L 1 V U L 1 V Output signal, loaded < 5 ma < 5 ma < 5 ma < 5 ma Resolution 0,05 m wind run 0,05 m wind run 0,05 m wind run 0,05 m wind run Wind load at 35 m/s ca. 10N ca. 10N ca. 10N ca. 10N Distance constant 5 m 5 m 5 m 5 m Ambient temperature -40... +80 C * -40... +80 C -40... +80 C -40...+80 C Supply (U B ) Electronics 4... 42V DC, 4... 42V DC, 4... 42V DC, 4... 42V DC, current consumption, < 0,5mA @ 5V < 0,5mA @ 5V < 0,5mA @ 5V < 0,5mA @ 5V (unloaded) Heating Not applicable Not applicable 24 V AC/DC, 20 W; 24 V AC/DC, 29 W; Connection 5 pole plug connection 7 pole plug connection 5 pole plug connection 5 pole plug connection Mounting onto mast tube 1 ½", e.g. DIN onto mast tube1 ½", e.g.. DIN onto mast tube1 ½", e.g. DIN onto mast tube1 ½", e.g. DIN Protection IP 55 IP 55 IP 55 IP 55 Weight 1 kg 1 kg 1 kg 1 kg Model Standard Standard Standard with reinforced cup star 10-16 021531/11/09

Order-no. 4.3303.22.007 4.3303.22.007D 4.3303.22.008 4.3303.22.018 Measuring range 0,3... 50 m/s 0,3... 50 m/s 0,5... 75 m/s 0,5... 75 m/s Starting velocity 0,3 m/s 0,3 m/s 0,5 m/s 0,5 m/s Max. load 60 m/s 60 m/s 75 m/s, temporary 75 m/s, temporary Accuracy Electrical output Frequency Form Amplitude Output signal (U L, U H ) unloaded ± 0,3 m/s resp. 2 % of 3... 1042 Hz (= 0,3... 50m/s) w/o offset ± 0,3 m/s resp. 2 % of 3... 1042 Hz (= 0,3... 50m/s) w/o offset U L 0 V ± 0,5 m/s resp. 2 % of 3... 754 Hz (= 0,5... 75 m/s) with offset U L 1 V ± 0,5 m/s resp. 2 % of 3... 754 Hz (= 0,5... 75m/s) w/o offset U L 0 V U L 0 V Output signal, loaded < 5 ma < 5 ma < 5 ma < 5 ma Resolution 0,05 m wind run 0,05 m wind run 0,1 m wind run 0,1 m wind run Wind load at 35 m/s ca. 10N ca. 10N ca. 10N ca. 10N Distance constant 5 m 5 m 5 m 5 m Ambient temperature -40... +80 C -40... +80 C -40... +80 C -40... +80 C Supply (U B ) Electronics 4... 42V DC, 4... 42V DC, 4... 42V DC, 4... 42V DC, current consumption, < 0,5mA @ 5V < 0,5mA @ 5V < 0,5mA @ 5V < 0,5mA @ 5V (unloaded) Heating 24 V AC/DC, 20 W; 24 V AC/DC, 20 W; 24 V AC/DC, 20 W; 24 V AC/DC, 20 W; Connection 7 pole plug connection 7 pole plug connection 5 pole plug connection 5 pole plug connection Mounting onto mast tube 1 ½", e.g. DIN onto mast tube 1 ½", e.g. DIN onto mast tube 1 ½", e.g. DIN onto mast tube 1 ½", e.g. DIN Protection IP 55 IP 55 IP 55 IP 55 Weight 1 kg 1 kg 1 kg 1 kg Model Standard Cup star with tapered seam With reinforced cup star With reinforced cup star 11-16 021531/11/09

Order-no. 4.3303.22.101 4.3303.22.600 4.3303.22.707 Measuring range 0,5... 50 m/s 0,3... 60 m/s 0,5... 75 m/s Starting velocity >0,5 m/s 0,3 m/s 0,5 m/s Max. load 60 m/s 60 m/s 75 m/s, temporary Accuracy Electrical output Frequency Form Amplitude Output signal (U L, U H ) unloaded ± 0,5 m/s resp. 2 % of 5... 1042 Hz (= 0,5... 50m/s) with offset U L 1 V ± 0,3 m/s resp. 2 % of 3... 1251 Hz (= 0,3... 60m/s) with offset U L 1 V ± 0,5 m/s resp. 2 % of 12-16 021531/11/09 5... 1490 Hz (= 0,5... 75m/s) w/o offset U L 0 V Output signal, loaded < 5 ma < 5 ma < 5 ma Resolution 0,05 m wind run 0,05 m wind run 0,05 m wind run Wind load at 35 m/s ca. 10N ca. 10N ca. 10N Distance constant 5 m 5 m 5 m Ambient temperature -40... +80 C -40... +80 C -40... +80 C Supply (U B ) Electronics 4... 42V DC, 4... 42V DC, 4... 42V DC, current consumption, < 0,5mA @ 5V (unloaded) < 0,5mA @ 5V < 0,5mA @ 5V Heating 24 V AC/DC, 20 W; 24 V AC/DC, 20 W; 24 V AC/DC, 20 W; Connection 5 pole plug connection 5 pole plug connection 7 pole plug connection Mounting onto mast tube 1 ½", e.g. DIN onto mast tube 1 ½", e.g. DIN onto mast tube 1 ½", e.g. DIN Protection IP 55 IP 55 IP 55 Weight 1 kg 1 kg 1 kg Model ship model with: - reinforced cup star - special ball bearings Standard With reinforced cup star

9 Dimensional Drawing

10 EC-Declaration of Conformity Document-No.: 000433 Month: 06 Year: 08 Manufacturer: A D O L F T H I E S G m b H & C o. K G Hauptstr. 76 D-37083 Göttingen Tel.: (0551) 79001-0 Fax: (0551) 79001-65 email: Info@ThiesClima.com Description of Product: Wind Transmitter Article No. 4.3303.10.000 4.3303.10.007 4.3303.22.000 4.3303.22.001 4.3303.22.007 4.3303.22.007D 4.3303.22.008 4.3303.22.018 4.3303.22.101 4.3303.22.600 4.3303.22.707 specified technical data in the document: 021530/03/07 The indicated products correspond to the essential requirement of the following European Directives and Regulations: 2004/108/EC 2006/95/EC DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 552/2004/EC Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004 on the interoperability of the European Air Traffic Management network (the interoperability Regulation) The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards: Reference number IEC 61000-6-2: 2005 IEC 61000-6-3: 2006 IEC 61010-1: 2001 Specification Electromagnetic compatibility Immunity for industrial environment Electromagnetic compatibility Emission standard for residential, commercial and light industrial environments Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements Place: Göttingen Date: 30.06.2008 This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. Please pay attention to the security advises of the provided instructions for use. 14-16 021531/11/09

15-16 021531/11/09

ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany P.O. Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com - Alterations reserved- 16-16 021531/11/09