Principles for Controlling Harmonics

Similar documents
POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

Harmonic control devices

Harmonic control devices. ECE 528 Understanding Power Quality

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

shunt (parallel series

Design and Simulation of Passive Filter

Do Capacitor Switching Transients Still Cause Problems?

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

Thyristorised Automatic Power Factor

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

HARMONICS CAUSES AND EFFECTS

Performance Analysis of Passive Filter for Harmonics Due to Non-Linear Load in Power System

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

Economical Solutions to Meet Harmonic Distortion Limits[4]

Power Quality and Power Factor Correction

Power Factor. Power Factor Correction.

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Low Pass Harmonic Filters

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with MTE Matrix AP Harmonic Filter vs. 18-Pulse Drive

Power Factor & Harmonics

NJWA - Harmonics and Drives Proper System Design

How adjustable speed drives affect power distribution

HVDC High Voltage Direct Current

Voltage and Current Waveforms Enhancement using Harmonic Filters

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 02 Issue: 04 July p-issn:

Comparison of Different Common Passive Filter Topologies for Harmonic Mitigation

OPTIMAL PASSIVE FILTER LOCATION BASED POWER LOSS MINIMIZING IN HARMONICS DISTORTED ENVIRONMENT

How Harmonics have led to 6 Power Factor Misconceptions

Transients under energizing multiple power filter circuits

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Application of SVCs to Satisfy Reactive Power Needs of Power Systems

International Journal of Advance Engineering and Research Development ANALYSIS AND MITIGATION OF HARMONICS IN MEDICAL FIELD

STUDY OF THE EFFECTS OF HARMONICS IN THE DESIGN OF TRANSMISSION NETWORK SHUNT COMPENSATORS: NETWORK SIMULATION AND ANALYSIS METHODS

TECHNICAL BULLETIN 004a Ferroresonance

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Analysis of Hybrid Power Conditioner in Three-Phase Four-Wire Distribution Power Systems for Suppressing Harmonics and Neutral-Line Current

Power Quality Improvement using Shunt Passive Filter

thepower to protect the power to protect i-gard LITERATURE Low and medium voltage

22.0 Harmonics in Industrial Power Systems

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Analysis of Harmonic Distortion in Non-linear Loads

2 Grounding of power supply system neutral

Harmonic Distortion Evaluations

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Power Quality enhancement of a distribution line with DSTATCOM

Effects of Harmonic Distortion I

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

McGill Power Sales & Engineering, INC.

Long lasting transients in power filter circuits

Harmonic Mitigation in Variable Frequency Drives: 6-Pulse Drive with Matrix AP Harmonic Filter vs. AFE Drive

Power electronic converters in power systems. SINTEF Energy Research

Outcomes of Harmonics & Its Reduction Techniques: A Comprehensive Review

New Pulse Multiplication Technique Based on Six-Pulse Thyristor Converters for High-Power Applications

Improving Passive Filter Compensation Performance With Active Techniques

Power Quality Analysis in Power System with Non Linear Load

BHARATHIDASAN ENGINEERING COLLEGE, NATTRAMPALLI DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING UNIT I

Welcome. Power Survey International

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Harmonic Analysis and Its Mitigation Using Different Passive Filters

Power Quality Notes 2-2 (AK)

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

A Novel Automatic Power Factor Regulator

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Harmonic Filters for Single Phase Equipment

RECENTLY, the harmonics current in a power grid can

Alternator winding pitch and power system design

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Harmonic Distortion Effects and Mitigation in Distribution Systems

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

POWER QUALITY ENHANCEMENT IN ARC FURNACE ENVIRONMENT Nupur Laxman Mali,

TUNED AMPLIFIERS 5.1 Introduction: Coil Losses:

Applications Note RF Transmitter and Antenna Design Hints

Understanding Input Harmonics and Techniques to Mitigate Them

Dr.Arkan A.Hussein Power Electronics Fourth Class. 3-Phase Voltage Source Inverter With Square Wave Output

ISSN Vol.03,Issue.07, August-2015, Pages:

LINEATOR. Advanced Universal Harmonic Filter

CHAPTER 1 INTRODUCTION

Filtering of harmonics and reactive power compensation

A Review on Simulation and Implementation of Thyristor controlled reactor and Shunt Hybrid Power Filter

Harmonic Filtering in Variable Speed Drives

Introduction to Rectifiers and their Performance Parameters

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI UNIT III TUNED AMPLIFIERS PART A (2 Marks)

HARMONIC distortion complicates the computation of. The Optimal Passive Filters to Minimize Voltage Harmonic Distortion at a Load Bus

v o v an i L v bn V d Load L v cn D 1 D 3 D 5 i a i b i c D 4 D 6 D 2 Lecture 7 - Uncontrolled Rectifier Circuits III

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Indirect Current Control of LCL Based Shunt Active Power Filter

Alternators Reactance for Nonlinear Loads

Unit.2-Voltage Sag. D.Maharajan Ph.D Assistant Professor Department of Electrical and Electronics Engg., SRM University, Chennai-203

A Thyristor Controlled Three Winding Transformer as a Static Var Compensator

Harmonic Distortion and Variable Frequency Drives

Characteristics of Crystal. Piezoelectric effect of Quartz Crystal

Examples Paper 3B3/4 DC-AC Inverters, Resonant Converter Circuits. dc to ac converters

Application of Tuned Passive Filter for Industrial Six-Pulse Rectifier with R-L Load Viralkumar A. Rana 1 Keyur Rana 2 Atul Talati 3

OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY

Transcription:

Principles for Controlling Harmonics Harmonic distortion is present to some degree on all power systems. Fundamentally, one needs to control harmonics only when they become a problem. There are three common causes of harmonic problems: The source of harmonic currents is too great. The path in which the currents flow is too long (electrically), resulting in either high voltage distortion or telephone interference. The response of the system magnifies one or more harmonics to a greater degree than can be tolerated. When a problem occurs, the basic options for controlling harmonics are: Reduce the harmonic currents produced by the load. Add filters to either siphon the harmonic currents off the system, block the currents from entering the system, or supply the harmonic currents locally. Modify the frequency response of the system by filters, inductors, or capacitors. These options are described in Secs. 6.2.1 through 6.2.3. Reducing harmonic currents in loads There is often little that can be done with existing load equipment to significantly reduce the amount of harmonic current it is producing unless it is being misoperated. While an overexcited transformer can be brought back into normal operation by lowering the applied voltage to the correct range, arcing devices and most electronic power converters are locked into their designed characteristics. PWM drives that charge the dc bus capacitor directly from the line without any intentional impedance are one exception to this. Adding a line reactor or transformer in series (as shown in Sec. 5.7.1) will significantly reduce harmonics, as well as provide transient protection benefits.

Transformer connections can be employed to reduce harmonic currents in three-phase systems. Phase-shifting half of the 6-pulse power converters in a plant load by 30 can approximate the benefits of 12-pulse loads by dramatically reducing the fifth and seventh harmonics. Delta-connected transformers can block the flow of zero-sequence harmonics (typically triplens) from the line. Zigzag and grounding transformers can shunt the triplens off the line. Purchasing specifications can go a long way toward preventing harmonic problems by penalizing bids from vendors with high harmonic content. This is particularly important for such loads as high-efficiency lighting. Passive Harmonic Filters Passive harmonic filters consisting of capacitors, inductors, and/or resistors can be classified into tuned filters and high-pass filters. They are connected in parallel with nonlinear loads such as diode/thyristor rectifiers, ac electric arc furnaces, and so on. Fig. 1. Passive tuned filters. (a) Single tuned. (b) Double tuned Fig. 2. Passive high-pass filters. (a) First order. (b) Second order. (c) Third order. Figs. 1 and 2 show circuit configurations of the passive filters on a per-phase base. Among them, the combination of four single-tuned filters to the fifth, seventh, 11 th, and 13 th harmonic frequencies and a second-order high-pass filter tuned around the 17 th harmonic frequency has been used in a high-power three-phase thyristor rectifier.

Installation of such a passive filter in the vicinity of a nonlinear load is to provide lowimpedance paths for specific harmonic frequencies, thus resulting in absorbing the dominant harmonic currents flowing out of the load. The actual value of the low-impedance path for each single-tuned filter is affected by the quality factor of the filter inductor, which determines the sharpness of tuning. Usually, a value of ranges between 20 and 100. Although a second-order high-pass filter provides good filtering performance in a wide frequency range, it produces higher fundamental-frequency loss than its corresponding single-tuned filter. Notch filters can provide power factor correction in addition to harmonic suppression. In fact, power factor correction capacitors may be used to make notch filters. Figure 6.13 shows one example of such a filter designed for medium voltage applications. The dry-type iron-core reactor is positioned atop the capacitors, which are connected in a wye, or star, configuration with the other phases (not shown). Each capacitor can is fused with a current limiting fuse to minimize damage in case of a can failure. In outdoor installations it is often more economical to use air-core reactors. Iron-core reactors may also be oil-insulated. Figure 6.13 One phase of a three-phase metal-enclosed filter. Figure 6.14 shows another design for industrial site applications. Here the reactors are placed on top of the cabinet housing the capacitors and switchgear.

Figure 6.14 Filter for industrial power system applications. An example of a common 480-V filter arrangement is illustrated in Fig. 6.15. The figure shows a delta-connected low-voltage capacitor bank converted into a filter by adding an inductance in series with the phases. In this case, the notch harmonic hnotch is related to the fundamental frequency reactances by

Figure 6.15 Creating a fifth-harmonic notch filter and its effect on system response One important side effect of this type of filter is that it creates a sharp parallel resonance point at a frequency below the notch frequency (Fig. 6.15c). This resonant frequency must be safely away from any significant harmonic or other frequency component that may be produced by the load. Filters are commonly tuned slightly lower than the harmonic to be filtered to provide a margin of safety in case there is some change in system parameters that would raise the notch frequency. If they were tuned exactly to the harmonic, changes in either capacitance or inductance with temperature or failure might shift the parallel resonance higher into the harmonic being filtered. This could present a situation worse than one without a filter because the resonance is generally very sharp. To avoid problems with this resonance, filters are added to the system starting with the lowest significant harmonic found in the system. For example, installing a seventh-harmonic filter usually requires that a fifth-harmonic filter also be installed. The new parallel resonance with a seventh-harmonic filter alone is often very near the fifth, which is generally disastrous.