Investigation the Performance of the Various Types of Harmonic Filters

Similar documents
ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

The unified power quality conditioner: the integration of series and shunt-active filters

ISSN Vol.03,Issue.07, August-2015, Pages:

SHUNT COMPENSATOR USED FOR POWER QUALITY IMPROVEMENT

Hybrid Active Power Filters for Reactive Power Compensation with Adaptive DC-Link Voltage Control

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

Simulation and Experimental Results of 7-Level Inverter System

Control Of Shunt Active Filter Based On Instantaneous Power Theory

A Time Domain Reference-Algorithm for Shunt Active Power Filters

Shunt Active Power Filter for Compensation of System Harmonics

Key-Words: - NARX Neural Network; Nonlinear Loads; Shunt Active Power Filter; Instantaneous Reactive Power Algorithm

HYSTERESIS CONTROL FOR CURRENT HARMONICS SUPPRESSION USING SHUNT ACTIVE FILTER. Rajesh Kr. Ahuja

Harmonic Reduction in Five Level Inverter Based Dynamic Voltage Restorer

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

A Simple Control Algorithm for Three-Phase Shunt Active Power Filter for Reactive Power and Current Harmonic Compensation

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Harmonics Reduction of 3 Phase Diode Bridge Rectifier by Implementing P-Q Theory with Active Filter

A New Control Method for Series Active Filter in Distribution System using Unit Vector Control

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

Harmonics Reduction using 4-Leg Shunt Active Power Filters

Review on Shunt Active Power Filter for Three Phase Four Wire System

29 Level H- Bridge VSC for HVDC Application

Comparison of Reference Current Extraction Methods for Shunt Active Power Filters

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

Power Quality improvement of a three phase four wire system using UPQC

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

A Novel FPGA based PWM Active Power Filter for Harmonics Elimination in Power System

HYBRID ACTIVE FILTER FOR REDUCTION OF CURRENT HARMONICS IN THREE PHASE SYSTEM USING SYNCHRONOUS REFERENCE FRAME THEORY

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

HYBRID ACTIVE FILTER WITH VARIABLE CONDUCTANCE FOR HARMONIC RESONANCE SUPPRESSION USING ANN

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives and Non- Linear Load System

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Cascaded Multilevel Inverter based Active Filter for Power Line Conditioners using Instantaneous mitigates

Literature Review for Shunt Active Power Filters

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

Analysis of Reference Current Generation for Shunt Active Power Filter Using SRF Algorithm to Compensate Harmonic Current

Multilevel Inverter Based Statcom For Power System Load Balancing System

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Improving Passive Filter Compensation Performance With Active Techniques

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

p. 1 p. 6 p. 22 p. 46 p. 58

ISSN Vol.03,Issue.42 November-2014, Pages:

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

A SPWM CONTROLLED THREE-PHASE UPS FOR NONLINEAR LOADS

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

HARMONIC ELIMINATION IN THREE PHASE SYSTEM BY MEANS OF A SHUNT ACTIVE FILTER

International Journal of Advance Research in Engineering, Science & Technology

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 3, May 2013

A COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES

CARRIER BASED PWM TECHNIQUE FOR HARMONIC REDUCTION IN CASCADED MULTILEVEL INVERTERS

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Implementation of SRF based Multilevel Shunt Active Filter for Harmonic Control

Simulation Study of PWM Techniques for Voltage Source Converters

ISSN: Page 20. International Journal of Engineering Trends and Technology- Volume2Issue3-2011

TRANSFORMER LESS H6-BRIDGE CASCADED STATCOM WITH STAR CONFIGURATION FOR REAL AND REACTIVE POWER COMPENSATION

2020 P a g e. Figure.2: Line diagram of series active power filter.

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Power Quality Improvement Using Hybrid Power Filter Based On Dual Instantaneous Reactive Power Theory With Hysteresis Current Controller

SERIES ACTIVE power filters have proved to be an interesting

Sinusoidal Current Control based Shunt Active Power Filter for Current Harmonics Reduction

Shunt Active Power Filter based on SRF theory and Hysteresis Band Current Controller under different Load conditions

CHAPTER 7 CONCLUSIONS AND FUTURE SCOPE

A Novel Control Method for Input Output Harmonic Elimination of the PWM Boost Type Rectifier Under Unbalanced Operating Conditions

Power Factor Correction of LED Drivers with Third Port Energy Storage

A Novel Automatic Power Factor Regulator

COMPENSATION OF POWER QUALITY PROBLEMS USING ACTIVE POWER FILTER

B.Tech Academic Projects EEE (Simulation)

Synchronous Reference Frame Control Algorithm Based Four -Leg Inverter DSTATCOM For Power Quality Improvement

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

POWER FACTOR CORRECTION AND HARMONIC CURRENT REDUCTION IN DUAL FEEDBACK PWM CONTROLLED AC/DC DRIVES.

MODIFIED CONTROL STRATEGY OF CASCADED H- BRIDGE MULTILEVEL CONVERTER IN GRID CONNECTED WIND ENERGY SYSTEM

Chapter 2 Shunt Active Power Filter

RECENTLY, the harmonics current in a power grid can

Modeling & Simulation of Micro Grid Distribution System to reduce Harmonics Using Active Power Filters and PI controllers

A MATLAB-SIMULINK APPROACH TO SHUNT ACTIVE POWER FILTERS

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

Exploration in Power Quality Furtherance on Shunt Active Power Filter

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Multi-Pulse Voltage Source Converter Statcom For Voltage Flicker Mitigation

HARMONIC contamination, due to the increment of nonlinear

A CONTROL TECHNIQUE FOR INSTANT MITIGATION OF VOLTAGE SAG/SWELL BY DYNAMIC VOLTAGE RESTORER

ADVANCES in NATURAL and APPLIED SCIENCES

Power Quality Improvement using Active shunt Power filter using PI Controller

A Comparative Study of Different Topologies of Multilevel Inverters

DESIGN OF A HYBRID ACTIVE FILTER FOR HARMONICS SUPPRESSION WITH VARIABLE CONDUCTANCE IN INDUSTRIAL POWER SYSTEMS USING FUZZY

DC-LINK VOLTAGE CONTROL ANALYSIS IN THREE PHASE FOUR WIRE HYBRID ACTIVE POWER FILTERS

Development of Multilevel Inverters for Control Applications

Transcription:

World Applied Sciences Journal 17 (5): 643-650, 2012 ISSN 1818-4952 IDOSI Publications, 2012 Investigation the Performance of the Various Types of Harmonic Filters R. Sriranjani and S. Jayalalitha EEE Department, School of EEE, SASTRA University Thirumalaisamudram, Thanjavur, Tamilnadu, India Abstract: The nonlinear load such as UPS, fan controller, mobile charger is distorting the supply current waveform. This current harmonics derates the power system equipment. To avoid this current harmonics, filters namely passive filter / active filter /hybrid filters are introduced in the supply line. In this paper the overall view of the performance of the various filters are studied and the performance of the transformerless single phase hybrid filter using artificial neural network(ann) is analysed using Matlab simulink and the results are presented. Key words: Nonlinear load Harmonics Passive filter Active filter Hybrid filter ANN INTRODUCTION have the disadvantages like the filtering characteristic depends of source impedance, blow the tuned frequency Harmonics have existed in power systems for many the impedance gets aggravated and fixed compensation years. The steep development of solid state electronics [2]. Then there was a demand for the use of Shunt active resulted in the introduction of delicate appliances which filters because it will provide harmonic compensation and affects the quality of the power. Some application of reactive power compensation [4]. The voltage source power converters are battery charger, UPS, Static VAR inverter/current source inverter is act as an active filter. compensator, electric drives and HVDC transmission This filter is designed to inject the harmonic current and line etc. because of the advantages of power fundamental reactive current. So supply is free from converters it is also used in medical field. The major harmonics and it is in-phase with the supply voltage. The problem of these electric utilities is the distortion of transformers are used to step down the voltage to the current and voltage waveforms. This current harmonics active filter and also it acts isolation between the filter and causes higher RMS current and voltage in the system the load [4]. But the active filter carries the dominant which results in misfiring of AC and DC drives, extra loss harmonic current and the fundamental reactive current in transformer winding this leads to increase in their hot then the cost of the device used in the filter is increased. spot temperature and reduction in insulation life, tripped In order to reduce the cost of the active filter, the passive circuit breakers, overheated conductors, voltage filter are connected so that the dominant harmonic current distortion, high neutral current and increased system are injected by the passive filter also the drawbacks of the losses [1-9]. Solutions are aimed to avoiding or passive filters are overcome by the active filter. This type overcoming harmonics include, phase cancellation, filters of filter is the hybrid filter. The transformerless hybrid and circuit detuning. filter will reduced the cost of the active filter [14]. In this Harmonics can be efficiently reduced through the use paper, the various types of filters such as passive, active of passive filters. The passive filters are series tuned filter, and hybrid filters for three phase nonlinear load and the double band pass filter and damped filter. The series control strategy for the filter are widely discussed. In the tuned filter is used to compensate a single tuned harmonic traction application the single phase active filters are used frequency and double band pass filter is used to [17]. Single phase hybrid filter with Artificial neural compensate two harmonic frequencies. These filters will network control is designed and the results are analysed compensate lower order harmonics. The damped filter is using Matlab simulink. The ANN control used for the used to compensate higher order harmonics so it will acts Shunt active filter is reducing the complexity of the as a high pass filter [3, 10-16]. But these types of filters conventional control design. Corresponding Author: R. Sriranjani, Department of EEE, School of EEE, SASTRA University, Thirumalaisamudram, Thanjavur, Tamilnadu, India. 643

Filters: The current harmonics are reduced by the Passive, Active and Hybrid filter. World Appl. Sci. J., 17 (5): 643-650, 2012 Passive Filter: Fig 1 shows the passive filters connected to the supply system and it is tuned to the dominant harmonic frequency. The cost of the passive filter is very low and it is easy to tune the particular frequency. This filter acts as zero impedance at the tuning frequency that absorbs the harmonics. There are many passive filter namely series tuned filters, double tuned band pass filters damped filters and anti resonant filters. Fig 1(b) shows the different configurations of passive filter. This filter has some drawbacks that the filtering characteristics dependent on the source impedance, not appropriate for variable load and there is a parallel resonance [2-8, 18,19] Fig 1(a): Passive filter Active Filter: Fig 2 shows the active filter which consists of the Voltage source inverter has been developed for reducing the total harmonic distortion of the supply current and also controls the reactive power. The classification of the active filters is the Series active filter and shunt active filter. The shunt active filter acts as a current source and it provides reactive power compensation where as the series active filter acts as a voltage source and it provides ac voltage regulation [2, 11, 13, 15,16, 20-22]. Due to some drawbacks of the active filter, the new (I) (ii) (iii) (iv) (v) filter was developed in 1988 [3]. Fig 3 shows the Shunt Fig 1(b): Different configuration of passive filters, (i) active filter which is used to compensate the reactive st series tuned (ii) double tuned (iii), (iv) and (v) 1, power and harmonic current generated by the three nd rd 2 and 3 - order damped phase diode rectifier [3]. The shunt active filter is connected to the supply mains through the transformer. The instantaneous reactive power theory is used to control the Shunt active filter. The supply current is sinusoidal and power factor reaches to unity. In this Shunt active filter, Passive filters are connected to the supply mains to compensate the voltage fluctuation and voltage distortion due to the DC drives.. This filter is the combination of Active and passive filter. The Shunt passive filter acts as low impedance at the harmonic frequency and the source impedance acts Fig 2: Active filter as low impedance at the fundamental frequency. This can be possible only by inserting the active filter in transient response of the supply current. So the series with the ac source. PWM converter is used as an PWM converter is controlled by the feedback loop of active filter. the supply current and its derivatives. This gives the Fig 4 shows the active filter which consists of a good dynamic response of the system. It has the Current source inverter. The active filter consists of a advantages of quick response, high reliability, easy current source PWM converter connected in parallel with protection and better current controlling capability. If the Controlled rectifier load [8]. The LC filters of the active Super conductor coils are used, it provides the lossless dc filter reduce the carrier harmonics but it affects the reactor [5, 23]. 644

Fig. 3: Shunt active filter and shunt passive filter for DC drive Fig 6: Active filter in series with Shunt passive filter Fig 4: Current source active filter Fig 7: Parallel hybrid filter Fig 5: Series active filter with tuned passive filter In practical case, the cost of the active filter is very high and constructing the active filter with large VA rating of low loss and rapid current response [4]. Hybrid filter: In 1988, the new filter was developed which is the combination of Active and Passive filter shown in Fig 5. The PWM converter acts as zero impedance at the dominant harmonic so it eliminates the limitations of the passive filters. The active filter are connected the supply mains through the current transformer and the LC filter. The LC filter is used to suppress the voltage spikes due the switching of the PWM converter. The low pass and high pass filters are connected to eliminate the dominant harmonics and high order harmonics. This filter eliminates the supply harmonics of the thyristor rectifier load. The PWM converter is protected against the over voltage and over current by turning off the upper leg switches and turning on the lower leg switches. The secondary are shorted with the dc capacitor so the converter is released from the secondary of current transformer. The instantaneous reactive power theory is used to control the active filter. The current flowing 645

impedance path so that the entire harmonic current is flow into the passive filter. This filter needs a small active filter but there is a large voltage drop at the fundamental frequency across the capacitor. This causes large current to flow in the inverter through the transformer. So the transformer is designed for high turns ratio which leads to high insulation voltage [10]. To reduce the VA rating of the active filter new structure of parallel hybrid filter was developed by S.Park in 1999 [10, 16]. The fundamental component of the supply current to the passive capacitor filter is controlled by the inductor L connected in parallel r with L. The active filter is controlled by the supply f Fig. 8: Parallel hybrid filter with two inductor parallel to a current detection method. The fundamental component of capacitor the active filter is extracted by synchronous reference frame and PI controller is used to regulate the DC bus voltage of the active filter. The KVA rating of the three phase active filter is obtained from the equation kva = 3. V inv. co+ Ch. Where V inv, I Co and ICh denotes the inverter output voltage, fundamental currents of the inverter and filter capacitor harmonic current. Further reduction in the cost of the active filter is achieved by removing the isolation transformer between the passive and active filter. This reduces the rating of the inverter to less than 10% compared to shunt active filter [14, 15]. The reactive current is flowing in the passive filter and a small size of active filter is used to reduce the current harmonics. Fig. 9: Single phase back to back connection of active Multilevel inverters are used as the active filter to filter reduce the supply current harmonics. Two or three single phase inverter are connected in series forms a multi level through the active filter is leading current of the passive inverter [24]. Fig 9 shows the a single phase back to back filter and the fundamental of the load current. This filter active filter for traction application. This filter provides the reducing the harmonics from the supply and the harmonic compensation and reactive power characteristics of the passive filters are also improved. For compensation. Measurement of Active power and high power application this filter is considerably suitable reactive power are done by Phase locked loop (PLL) in to compensate the harmonics. But it is difficult to protect phase A and phase B [17]. The control strategy needs against a short circuit fault. The Q factor of the passive many low pass filter, PLL, arthimetic and logical operators. filter decides the VA rating of the active filter [4]. The VA This forms the control circuit very complex. In order to rating of this active filter is reduced by the combination of reduce the complexity of the control circuit of active filter, active filter in series with the shunt passive filter ANN techniques are used which is shown in Fig 6. This filter eliminates the In this paper, a single phase hybrid filter using problem when passive filter alone used in the supply artificial neural network is designed to control the system. The current flowing through the active filter is harmonics without a transformer. The artificial neural harmonic current and the leading current of the passive network reduces the complexity of the control circuit and filter. It is easy to protect and isolate from the supply reduces the rating of the active filter control circuit. The system. This type of filters is series hybrid filter. modified Widrow - Hoff algorithm is used to calculate the Fig 7 shows the parallel hybrid filter where active weight matrix (W) [25]. filter connected with the tuned passive filter through the three phase transformer. The active filter provides the low The supply voltage V =V sinw t (1) s m 1 646

The supply current is given by () = sin( +Φ ) i t I k t L k 1 k k = 1 This current contains fundamental current and harmonic current. World Appl. Sci. J., 17 (5): 643-650, 2012 (2) () = sin( + ) + sin( +Φ ) i t I t I k t L 1 1 1 k 1 k k = 2 i () t = i () t + i () t L f h i () t = i () t i () t h L f i ( t) = I sin( t) f 1 1 (3) (4) (5) (6) Where I 1 is the amplitude of the fundamental component of the load current and 1 is the supply frequency (50Hz). From equation (1) Uing equation (7) in (6) sin () () 1 h = L s Vm V t = V 1 s m I i () 1 f t = V V So, I i t i t V (9) m s (7) (8) Fig. 10: Single phase Shunt hybrid Active filter Fig. 11: Reference current extraction using ANN In the ANN, the error is calculated by The output matrix is given by e = d - y (10) n n n L yn = x w n 1 ln l= 0 (11) Where d is the desired output, y is the actual output, x n n n is the input variable. The weight matrix w = w + X e (12) n n-1 n n Where w is the weight matrix, is the learning rate, x n is the input variable and e n error. Then from the above equation, the weight matrix for the system is w = w + Vi n n 1 sh I w = V 1 m (13) From equation (9),(10) and (11), the weight w is given by (14) Fig. 12: Reference current waveform Where I1and V m is the fundamental component of load current and the maximum supply voltage. The new control strategy was developed to extract the fundamental component of the supply current which is the reference current for the hysteresis controller shown in Fig 11. Fig 12 shows the fundamental component of the supply current extracted by modified widrow hoff algorithm and it is compared with the actual supply current using hysteresis current controller [26]. This control design is very simple and it reduces the complexity of the control circuit where the instantaneous 647

Fig. 13: Supply current waveform and Frequency Fig. 15: Supply current and frequency spectrum of supply spectrum of the supply current without filter for current with out filter = 36 =54 Fig. 14: Supply current and frequency spectrum of supply Fig. 16: Supply current and frequency spectrum of supply current with filter = 54 current with filter =36 648

reactive power theory is used to extract the reference 7. Hayashi, Y., N. Sato and K. Takahashi, 1988. current in the paper [27]. Fig 13 & Fig 15 shows the A novel control of a current source active filter for current waveform and frequency spectrum of the AC power system harmonic compensation, IEEE, supply current with out filter for the firing angle 54 and 8. Nakajima, T., M. Tamura and E. Masada, 1988. 36. The Total harmonic distortion of the supply current Compensation of non stationary harmonics using is 30.7% and 17%. When the Shunt active filter is active power filter with prony s spectral estimation, connected to the supply mains the THD is reduced to PESC. 13% and 9% respectively. Fig 14 & Fig 16 shows the 9. Yazdani-asrami, M., M. Mirzaie and A. Shayegani waveform of the supply current with filter. The supply Akmal, 2010. Calculation of transformer losses under current is nearly sinusoidal and power factor reaches near non sinusoidal currents using : two analytical method to unity. and finite element analysis World Applied Science J., 9(8): 889-897. CONCLUSIONS 10. Fujita, H. and H. Akagi, 1991. A Practical approach to harmonic compensation in power systems - series Various types of filters are studied in this paper. connection of passive and active filters, IEEE Trans. The active filter overcomes the drawbacks of the passive Ind Appli, Vol 27, No.6, Nov/Dec 1991. filter. But the cost of the active filter is high so the passive 11. Akagi, H., 1996. New Trends in Active Filters for and active filter are combined together, forms a hybrid Power Conditioning, IEEE Trans on Ind. Appl., filter. Different configuration of hybrid filter is also 32(6): 1312-1322. studied. In the parallel hybrid filter the cost of the active 12. Tai P.O. Cheng, S. Bhattacharya and Deepak D. filter is very much reduced. If the isolation transformer is Divan, 1999. Line harmonics reduction in high removed from the supply, the cost of the active filter is power systems using square wave inverters based reduced to 10%. In traction system, single phase back to dominant harmonic active filter, IEEE Trans. Power back shunt active filter is connected to reduce the current Electronics, 14: 2. harmonics. The control circuit is very complex so ANN 13. Akagi, H. and O. Okayama, 2000. Active and Hybrid based control of Shunt active filter is analyzed using filters for power conditioning, ISIE. Matlab simulink and waveforms shows that the supply 14. Rubén Inzunza and Hirofumi Akagi, 2005. A 6.6-kV current is near to sinusoidal. The control strategy used in Transformerless Shunt Hybrid Active Filter for this paper is very simple and it can be implemented for Installation on a Power Distribution System, IEEE any configuration of the active and hybrid filter. Transactions On Power Electronics, 20: 4. 15. Asiminoaei, L., W. Wiechowski and Frede blaabjerg, REFERENCES T. Krzeszowiak and B. Kedra, 2006. A new control structure for hybrid power filter to reduce the inverter 1. Robert, E. and P.E. Fuhr, 2001. Save Energy and power rating, IEEE. Improve Power Quality, Power Sytems Engineering, 16. Singh, B. and V. Verma, 2006. An indirect current P.S, control of hybrid power filter for varying loads, in 2. George J. Wakileh, 2001. Power system harmonics IEEE Trans. On Power Delivery, 21(1): 178-184. Fundamentals, analysis and filter design, Springer - 17. Shu, Z., S. Xie and Q. Li, 2011. Single phase back to verlag Berlin Heidelberg, New York, back converter for active power balancing, reactive 3. Nassif, A.B. and Wilsun Xu, 2007. Passive Harmonic power compensation and harmonic filtering in Filters for Medium-Voltage Industrial Systems: traction power system, IEEE Trans. Power Practical Considerations and Topology Analysis, Electronics, 26: 2. IEEE, pp: 301-307. 18. Compensation characteristics of combined system 4. Gyugyi, L. and E.C. Strycula, 1976. Active ac power of shunt passive and series active filter, 1989. filters, in proc. IEEE/IAS Ann Meet., pp: 529. IEEE/IAS Ann. Meeting conf. Rec., pp: 959-966. 5. Takeda, H., K. Ikeda, A. Teramoto and T. Aritsuka, 19. Fukuda, S. and M. Yamaji, 1990. Design and 1988. Harmonic current and reactive power characteristics of active power filter using current compensation with an active filter, PESC, source converter, IEEE Trans., 6. Peng, F.Z., H. Akagi and A. Nabae, 1988. A new 20. Prgitzer, R., J.G. Pinto, M. Joao and Joao L. Afonso, approach to harmonic compensation in power 2007. Parallel Association of Shunt active filters, system, IEEE Trans. Power Delivery, IEEE. 649

21. Chaoui, A., J. Paul Gaubert, F. Krim and L. Rambault, 25. Wenjin Dai, Taiyang Huang and Na Lin, 2007. 2008. On the design of Shunt active filter for Single-phase Shunt Hybrid Active Power Filter improving power quality, IEEE. Based on ANN, Fourth International Conference on 22. Abdusalam, M., P. Poure and S. Saadate, 2008. Fuzzy Systems and Knowledge Discovery (FSKD). Hardware implementation of a three phase active 26. Hani Vahedi, Abdelreza sheikholeslami and filter system with harmonic isolation based on self Mohammed Tavakoli bina, 2011. Reverse direction tuning filter, IEEE. of hysteresis bandwidth calculation to fix the 23. Alper Terciyanli, Muammer Ermis and Is k Cadirci, switching frequency employed in Active power 2009. A Selective Harmonic Amplification Method filter, World Applied Science J., 15(7):1007-1011. for Reduction of kva Rating of Current Source 27. Nayeripour, M. and T. Niknam, 2008. Nonlinear Converters in Shunt Active Power Filters, IEEE sliding mode control design for Shunt active power Transactions On Power Delivery, 24: 1. filter with the minimization of load current, World 24. Zhong Du, Leon M. Tolbert, Burak Ozpineci and Applied Science J., 4(1): 124-132. John N. Chiasson, 2009. 'Fundamental Frequency Switching Strategies of a Seven-Level Hybrid Cascaded H-Bridge Multilevel Inverter IEEE Transactions On Power Electronics, 24: 1. 650